• 제목/요약/키워드: Lateral Resolution

검색결과 168건 처리시간 0.032초

Stereotactic Mesencephalotomy for Cancer - Related Facial Pain

  • Kim, Deok-Ryeong;Lee, Sang-Won;Son, Byung-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • 제56권1호
    • /
    • pp.71-74
    • /
    • 2014
  • Cancer-related facial pain refractory to pharmacologic management or nondestructive means is a major indication for destructive pain surgery. Stereotactic mesencephalotomy can be a valuable procedure in the management of cancer pain involving the upper extremities or the face, with the assistance of magnetic resonance imaging (MRI) and electrophysiologic mapping. A 72-year-old man presented with a 3-year history of intractable left-sided facial pain. When pharmacologic and nondestructive measures failed to provide pain alleviation, he was reexamined and diagnosed with inoperable hard palate cancer with intracranial extension. During the concurrent chemoradiation treatment, his cancer-related facial pain was aggravated and became medically intractable. After careful consideration, MRI-based stereotactic mesencephalotomy was performed at a point 5 mm behind the posterior commissure, 6 mm lateral to and 5 mm below the intercommissural plane using a 2-mm electrode, with the temperature of the electrode raised to $80^{\circ}C$ for 60 seconds. Up until now, the pain has been relatively well-controlled by intermittent intraventricular morphine injection and oral opioids, with the pain level remaining at visual analogue scale 4 or 5. Stereotactic mesencephalotomy with the use of high-resolution MRI and electrophysiologic localization is a valuable procedure in patients with cancer-related facial pain.

Single Shot Epidural Injection for Cervical and Lumbosaccral Radiculopathies: A Preliminary Study

  • Nawani, Digambar Prasad;Agrawal, Sanjay;Asthana, Veena
    • The Korean Journal of Pain
    • /
    • 제23권4호
    • /
    • pp.254-257
    • /
    • 2010
  • Background: Epidural steroid injection is an established treatment modality for intervertebral disc prolapse to radiculopathy. In cases where two levels of radiculopathy are present, two separate injections are warranted. Herein, we present our experience of management of such cases with a single epidural injection of local anaesthetic, tramadol and methylprednisolone, and table tilt for management of both radiculopathies. Methods: 50 patients of either sex aged between 35-65 years presenting with features of cervical and lumbar radiculopathic pain were included and were subjected to single lumbar epidural injection of local anaesthetic, tramadol and methylprednisolone, in the lateral position. The table was then tilted in the trendelberg position with a tilt of 25 degrees, and patients were maintained for 10 minuted before being turned supine. All patients were administered 3 such injections with an interval of 2 weeks between subsequent injections, and pain relief was assessed with a visual analogue scale. Immediate complications after the block were assessed. Results: Immediate and post procedural complications observed were nausea and vomiting (20%), painful injection site (4%), hypotension (10%) and high block (4%). Pain relief was assessed after the three injections by three grades: 37 (74%) had complete resolution of symptoms; 18% had partial relief and 8% did not benefit from the procedure. Conclusions: This technique may be used as an alternative technique for pain relief in patients with unilateral cervical and lumbar radiculopathies.

Structure of Ni and NiO Nanoparticles Observed by X-ray Coherent Diffraction Imaging

  • Kim, Chan;Kim, Yoon-Hee;Hamh, Sun-Young;Son, Jun-Gon;Khakurel, Krishna Prasad;Iqbal, Mazhar;Noh, Do-Young
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.542-543
    • /
    • 2012
  • Coherent diffraction imaging (CDI) method using hard x-ray at 5.46 keV was applied to study assembly of Ni and Ni oxide nano structures formed on a Si3N4 membrane. Density distribution of Ni nano-particles was obtained quantitatively with about 15 nm lateral resolution by reconstructing images from the speckle diffraction pattern. In addition, reconstructed images of nickel oxide particles indicated that Ni atoms diffuse out during the oxidation process leaving pores inside the nickel oxide crust. Furthermore, we recognize that really weak phase object, less than 5 nm thickness of Ni residues, can be reconstructed due to the reference particles. We achieved quantitative information of nanometer sized materials and demonstrate the effect of reference particles by using hard x-ray coherent diffractive imaging method.

  • PDF

가중된 직교 선형 FM신호를 이용한 송신 동시 다중 빔집속 기반의 초음파 영상 기법 (Simultaneous Multiple Transmit Focusing Using Orthogonal Weighted Linear FM Chirp)

  • 정영관;송태경
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(4)
    • /
    • pp.155-158
    • /
    • 2001
  • A new method for simultaneous multiple transmit focusing using orthogonal weighted FM chirp is proposed. Weighted chirp signals focused at different depths are transmitted at the same time. These chirp signals are mutually orthogonal in the approximate sense that the autocorrelation function of each signal has a narrow mainlobe width and low sidelobe levels, and the crosscorrellation function of any pair of the signals has smaller values than the sidelobe levels of each autocorrelation function. This means that each weighted chirp signal can be separately compressed into a short pulse, focused individually and combined with other focused beams to form a frame of image. Theoretically, any two chirp signals defined in two nonoverlapped frequency bands are mutually orthogonal. In the present work, however, a fractional overlap of adjacent frequency bands, by up to 25%, were permitted to design more chirp signals within a given transducer bandwidth. The crosscorrelation values due to the frequency overlap could be reduced by alternating the direction of frequency sweep of the adjacent chirp signals. The simulation results show that this method can improve the lateral resolution of image without sacrifice in the frame rate compared with the conventional pulse system.

  • PDF

3-D Reconstruction of Human Face Using the Derivative Moiré Topography

  • Bae, Yoon Jae;Ha, Byeong Wan;Park, Ji An;Cho, Choon Sik
    • Journal of the Optical Society of Korea
    • /
    • 제18권5호
    • /
    • pp.500-506
    • /
    • 2014
  • A new 3-D reconstruction algorithm for the human face is proposed using the derivative Moir$\acute{e}$ topography which ensures fast and robust reconstruction even for rough surfaces. The Moir$\acute{e}$ interference fringe pattern is initially obtained through the projection Moir$\acute{e}$ topography based on phase shifting, and then differentiated to provide a full unwrapped phase map for a human face. $2{\pi}$ ambiguity, which has been a chronically unsolved problem with Moir$\acute{e}$ topography, is successfully surmounted by differentiating the Moir$\acute{e}$ fringe patterns both in x- and y-directions when the object is located in the x-y plane. A real human face is used for verifying the proposed derivative Moir$\acute{e}$ topography. A human face of 4 different phase-shifted images taken in the fixed plane is almost fully reconstructed in 3-D format in 0.1 mm lateral resolution.

질감 제시 장치를 이용한 촉감인지 특성 연구 (Study of Human Tactile Sensing Characteristics Using Tactile Display System)

  • 손승우;경기욱;양기훈;권동수
    • 제어로봇시스템학회논문지
    • /
    • 제11권5호
    • /
    • pp.451-456
    • /
    • 2005
  • This paper describes three kinds of experiments and analysis of their results related to human tactile sensitivity using an integrated tactile display system. The device can provide vibration, normal pressure and lateral slip/stretch which are important physical quantities to sense texture. We have tried to find out the efficient method of stimulating, limitation of surface discrimination by kinesthetic farce feedback and the effectiveness of the combination of kinesthetic force and tactile feedback. Seven kinds of different stimulating methods were carried out and they are single or combination of the kinesthetic force, normal static pressure, vibration, active/passive shear and moving wave. Both prototype specimen and stimulus using tactile display were provided to all examinees and they were allowed to answer the most similar sample. The experimental results show that static pressure is proper stimulus for the display of micro shape of the surface and vibrating stimulus is more effective for the display of fine surface. And the sensitivities of active touch and passive touch are compared. Since kinesthetic force feedback is appropriate to display shape and stiffness of an object, but roughness display has a limitation of resolution, the concurrent providing methods of kinesthetic and tactile feedback are applied to simulate physical properties during touching an object.

뉴질랜드 크라이스트처어치 지진에 의해 발생된 영구지반변형과 매설된 상수도관 성능평가 (Permanent Ground Deformation induced by Christchurch Earthquake and Estimation of Underground Water Pipeline Performance in New Zealand)

  • 전상수
    • 한국산학기술학회논문지
    • /
    • 제16권6호
    • /
    • pp.4201-4207
    • /
    • 2015
  • 본 연구에서는 최근 뉴질랜드의 Christchurch 지역의 2011년 2월 22일의 지진규모(Mw) 6.2 지진발생 후 얻어진 데이터를 이용하여 지진에 의한 지하 상수도관 시스템의 성능에 주안점을 두고 연구를 수행하였다. 이 논문은 액상화로 인하여 발생된 영구지반변형지역과 서로 다른 재질의 상수도관에 따라 1 km 당 손상갯수로 산정되는 손상율을 액상화 지역에서의 지진발생 전후에 얻어진 높은 해상도의 라이다데이터로부터 계산된 부등침하와 횡방향 지반변형률의 관계를 통하여 산정하였다. 본 연구에서는 영구지반변형에 따른 매설된 상수도관의 지진성능을 요약하여 설명하였으며 연구결과 연성이 매우 큰 폴리에틸렌 상수도관이 매우 우수한 지진성능을 가지고 있음을 알 수 있다.

Anatomical study of divergences in facial artery endings

  • Yasser Ayish Alharbi
    • Anatomy and Cell Biology
    • /
    • 제56권2호
    • /
    • pp.211-218
    • /
    • 2023
  • Despite several studies focusing on the facial arteries variable courses, the findings have significantly differed. The divergent findings have made it increasingly challenging to establish consistent correlations. Thus, as a vital artery, the facial artery is prone to numerous variations, which makes the identification of the variations vital to clinical practice, particularly for the orofacial and rhinoplastic surgery, and the increasingly selective chemotherapy procedures. The present research uses angiography images for analysis in studying the bilateral facial artery variations noted in patients undergoing carotid angiography for the evaluation of congenital anomalies, cerebral vascular malformations, and intra-arterial procedures. Conventional angiography was used, as it is a vital assessment tool that helps in the assessment of variations in the facial arteries and is suitable in evaluating smaller vascular anatomy, due to the perfect spatial resolution and portrayal of vascular anatomy. Thus, rather than normal ending of the facial artery as an angular artery, the study disclosed that in certain instances, the artery termination took the form of a superior labial artery with a small lateral nasal artery branch located closer to the midline compared to the normal cases. Also, the study has disclosed a conspicuous pre-masseteric branch with small branches originating from the infraorbital artery and providing potential compensation for the facial artery's shortness. Regardless of the infrequency of such variations, it is vital that they are considered during the performance of any facial surgical procedure.

유리선량계를 이용한 요추검사의 장기선량 및 영상의 평가 (Evaluation on Organ Dose and Image Quality of Lumbar Spine Radiography Using Glass Dosimeter)

  • 김재겸;김정구
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권1호
    • /
    • pp.1-11
    • /
    • 2016
  • 본 연구는 디지털 방사선촬영 시스템에서 요추검사 시 조사야 크기에 따른 주변 장기선량과 요추 영상의 화질 변화를 정량화하여 의료피폭 저감화를 위한 자료를 제공하고자 하였다. 요추검사 시 조사야 크기는 $8^{\prime\prime}{\times}17^{\prime\prime}$에서 $14^{\prime\prime}{\times}17^{\prime\prime}$ 크기까지 변화하였으며, RANDO 팬텀을 대상으로 요추 전-후방향, 측방향 검사를 실행하였다. 장기선량은 간, 위, 췌장, 신장, 생식선을 선택하여 유리선량계로 측정하였으며, Image J로 영상 분해능을 비교 분석하였다. 전-후방향 촬영에서 요추의 주변 장기선량은 조사야 크기가 작아짐에 따라 감소하였으나, 생식선에서는 조사야의 가로축 길이가 1" 작아질 때마다 3.83%로 감소율의 변화가 없었다. 측방향 촬영에서 간, 신장과 같이 표면과 가까운 장기에서 장기선량은 높은 선량이 나타났으나, 조사야의 가로축 길이가 1" 작아질 때마다 감소율이 5% 이내로 나타났다. 그러나 생식선에서는 조사야의 가로축 길이가 1" 작아질 때마다 감소율이 24.34%로 나타났다. 조사야 내, 외부에 대한 선량 차이는 간에서 $549.8{\mu}Gy$, 위에서 $264.6{\mu}Gy$로 감소하였으나, 생식선에서는 평균 $1,135.1{\mu}Gy$로 큰 변화가 없었다. 조사야 크기에 따른 영상은 전-후방향 촬영에서 $9^{\prime\prime}{\times}17^{\prime\prime}$, 측방향 촬영에서 $10^{\prime\prime}{\times}17^{\prime\prime}$ 이하의 크기에서 30 dB 이상으로 영상의 질적 차이를 구분할 수 없었다. 따라서 요추검사는 다른 검사 부위보다 주변장기들이 많이 포함하고 있기 때문에 불필요한 환자의 피폭선량을 줄이고 양질의 영상을 얻기 위하여 조사야 크기 설정에 관한 권고기준안이 제시되어야 할 것으로 사료된다.

초음파 영상 장치에서 직교 쳐프 신호를 이용한 동시 다중 송신집속 기법 (Simultaneous Multiple Transmit Focusing Method with Orthogonal Chirp Signal for Ultrasound Imaging System)

  • 정영관;송태경
    • 대한의용생체공학회:의공학회지
    • /
    • 제23권1호
    • /
    • pp.49-60
    • /
    • 2002
  • 본 논문에서는 프레임율의 저하없이 개선된 해상도를 얻을 수 있는 동시 다중 송신집속 기법을 제안한다. 제안한 기법은 짧은 펄스를 사용하여 한 영역에 고정 송신 집속하는 기존의 방법과는 달리 여러 송신 집속점에 서로 독립적으로 집속된 쳐프 신호들을 동시에 송신한다. 수신된 신호는 정합 과정을 통하여 송신 집속 위치에 따라 각 쳐프 신호로 분리되고 짧은 펄스로 압축된다. 이렇게 압축되고 분리된 신호들은 각각 수신 동적 집속된 후 거리에 따라 집속 위치별로 선택되고 하나의 신호로 결합되어 개선된 측방향 해상도의 영상을 구성한다. 송신시 동시에 여러 위치에 초음파를 집속하고 수신시 이를 분리하기 위해서 사용된 터프 신호들은 주파수 대역에서 분할되어 서로 직교 특성을 갖도록 설계되었는데 변환자의 제한된 대역폭내에 많은 수의 의미있는 쳐프 신호를 설계하기 위해서 인접한 두 쳐프 신호의 주파수 대역 겹침을 허용하였다. 이때 대역 겹침으로 발생한 상호상관값의 상승을 억제하기 위해 인접한 두 쳐프 신호의 주파수 변화 방향을 엇갈리게 하는 밥법을 제안하였다. 특히 대역분할로 설계된 쳐프 신호중 낮은 주파수 성분의 신호를 변환자로부터 가까운 지역에 집속하고 높은 주파수 성분의 쳐프 신호를 먼 지역에 집속함으로써 깊이에 따라 영상의 해상도의 질을 일정하게 유지시켰다 더욱이 상관기를 이용한 정합 과정에서 신호가 압축되기 때문에 펄스 압축 기법에서 얻는 SNR를 증가시키는 이점이 있다 이때 상관기를 통한 압축 과정에서 쳐프 신호의 첨두값이 쳐프 신호의 길이에 따라 증가하기 때문에 깊이에 따를 높은 주파수 성분의 감쇄에도 불구하고 이렇게 높은 주파수 성분의 터프 신호를 깊은 지역에 사용할 수 있었다. 제안한 동시 다중 송신집속 기반의 시스템을 상관기의 위치에 따라 이상적인 구조와 현실적인 구조로 나타냈으며, 모사 실험을 통하여 기존의 펄스 집속 기법과 비교하여 그 성능을 검증하였다.hrough the medium. By digitizing the analog receiver outputs, and recording the signals for spectral analysis, surface wave velocities can be identified. Modifications to the SASW method includes the reduction of boundary reflections as adopted on the surface waves before the point where the reflected compression waves reach the receivers. In this study, the correlation between the surface wave velocity and the compressive strength of cement mortar is developed using one 36"x36"x4"(91.44$\times$91.44$\times$91.44 cm) cement mortar slab of 2,000 psi (140 kgf/$\textrm{cm}^2$) and two 36"x36"x4"(91.44$\times$91.44$\times$91.44 cm) cement mortar slabs of 3,000 psi (210 kgf/$\textrm{cm}^2$). public transportation, and availability of locally grown food were the important factors for deciding the place compared to those who had higher education. The price was the factor which