• Title/Summary/Keyword: Lateral Plane

Search Result 645, Processing Time 0.036 seconds

2D Pattern Development of Body Surface from 3D Human Scan Data Using Standing and Cycling Postures (3D 스캔을 이용한 사이클 동작 전후 체표 변화 고찰 및 2D 전개 패턴의 비교)

  • Jeong, Yeonhee;Lee, Yejin
    • Korean Journal of Human Ecology
    • /
    • v.21 no.5
    • /
    • pp.975-988
    • /
    • 2012
  • Although the pattern development for tight-fitting clothing has been carried out using 3D data on humans, the pattern development using 3D scan data obtained for various postures still remains an interesting subject. In this study, we have developed the 2D pattern using the 3D human body reflecting standing and cycling postures. The 3D scan data of a subject was obtained using Cyberware. 2C-AN program(Triangle simplification and the Runge-Kutta method) was used in the system to reduce the 3D scan data points and to make segmented triangular patches in a plane from 3D data. As results, surface distance and area of each body part of standing and cycling postures were also provided for the future application of the functional clothing construction. The area of center piece on the front (c.front) decreased by $106.45cm^2$(-13.08%) and that of lateral piece(s.back) on the back increased by $144.96cm^2$(18.69%) in the patterns of cycling posture. The girth of neck and waist for the cycling posture increased by 0.88cm (3.92%) and 1.56cm(4.40%) respectively, and the that of thigh decreased by 1.01cm(-2.24%). The differences between the area in the 2D pattern obtained from the 3D scan data and that in the 3D scan surface data for standing and cycling postures were very small($-10.34cm^2$(-0.32%) and $-44.33cm^2$(-1.32%)).

Performance evaluation of a seismic retrofitted R.C. precast industrial building

  • Nastri, Elide;Vergato, Mariacristina;Latour, Massimo
    • Earthquakes and Structures
    • /
    • v.12 no.1
    • /
    • pp.13-21
    • /
    • 2017
  • Recent seismic events occurred in Italy (Emilia-Romagna 2012, Abruzzo 2009) and worldwide (New Zealand 2010 and 2011) highlighted some of the weaknesses of precast concrete industrial buildings, especially those related to the connecting systems traditionally employed to fasten the cladding panels to the internal framing. In fact, one of the most commons fails it is possible to observe in such structural typologies is related to the out-of-plane collapse of the external walls due to the unsatisfactory behaviour of the connectors used to join the panels to the perimeter beams. In this work, the strengthening of a traditional industrial building, assumed as a case study, made by precast reinforced concrete is proposed by the adoption of a dual system allowing the reinforcement of the structure by acting both internally; by pendular columns and, externally, on the walls. In particular, traditional connections at the top of the walls are substituted by devices able to work as a slider with vertical axis while, the bottom of the walls is equipped with two or more hysteretic dampers working on the uplift of the cladding panels occurring under seismic actions. By means of this approach, the structure is stiffened; obtaining a reduction of the lateral drifts under serviceability limit states. In addition, its seismic behaviour is improved due to the additional source of energy dissipation represented by the dampers located at the base of the walls. The effectiveness of the suggested retrofitting approach has been checked by comparing the performance of the retrofitted structure with those of the structure unreinforced by means of both pushover and Incremental Dynamic Analyses (IDA) in terms of behaviour factor, assumed as a measure of the ductility capacity of the structure.

A Response to Postural Response to Sine Curve Vestibular Electric Stimulation during Standing (기립자세동안 전정기관에 인가된 정현파 전류자극에 대한 자세균형 응답)

  • Lee, Ah-Reum;Yu, Mi;Kim, Jin-Ho;Kim, Dong-Wook;Kim, Jung-Ja
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.3
    • /
    • pp.210-216
    • /
    • 2010
  • This study is vestibular electric stimulation applied between the mastoids during quiet standing elicits postural sway. The aim of this study was to characterize the postural sway response to continuous sinusoidal vestibular electric stimulation across various stimulus frequencies and amplitudes. Binaural bipolar sinusoidal vestibular electric stimulation was applied to the skin overlying the mastoid processes of 10 subjects while they stood on a force plate. The position of the center of pressure(COP) and signals at the feet are obtained on an force plate, while the head and whole body center of mass(COM) was measured with motion analysis system. The stimulus conditions included eight frequencies (1/64, 1/32, 1/16, 1/8, 1/4, 1/2, 1, and 2Hz) and six peak amplitudes (0.1, 0.25, 0.5, 0.7, 1 and 2mA). Each subject experienced one trial at each amplitude-frequency pair. The stimuli elicited sway in lateral plane in all subjects, as evidenced by changes in the stimulus frequency. Our results demonstrate that the vestibular system is sensitive to vestibular electric stimulation intensity changes and responds by altering the magnitude of the response accordingly.

A study on the Cochlear View in Multichannel Cochlear Implantees (인공와우 이식술 환자의 Cochlear View 촬영에 관한 연구)

  • Kweon, Dae-Cheol;Kim, Jeong-Hee;Kim, Seong-Lyong;Kim, Hae-Seong;Lee, Yong-Woo
    • Journal of radiological science and technology
    • /
    • v.22 no.2
    • /
    • pp.27-32
    • /
    • 1999
  • Cochlear implant poses a contraindication to the magnetic resonance imaging(MRI) process, because MRI generates artifacts, inducing an electrical current and causing device magnetization. CT is relatively expensive and the metal electrodes scatter the image. Post-implantation radiological studies using anterior-posterior transorbital, submental-vertex and lateral views, the intracochlear electrodes are not well displayed. Therefore, the authors developed a special view, which we call the cochlear view. The patient is sitting in front of a vertical device. Then the midsagittal plane is adjusted to form an angle of $15^{\circ},\;30^{\circ}$, and $45^{\circ}$ with the film. The flexion of the neck is adjusted to make the infraorbitomeatal line(IOML) is parallel with the transverse axis of the film. The central ray is directed to exit from the skull at point which is 3.0 cm anterior and 2.0 cm superior to the EAM(external auditory meatus). Results have shown that single radiography of the cochlear view provides sufficient information to demonstrate the position of the electrodes array and the depth of insertion in cochlear. Radiography of the cochlear view in angle of $45^{\circ}$ is an excellent image. The cochlear view gives the greatest amount of medical information with the least radiation and lowest medical cost. It can be widely used in all cochlear implant clinics.

  • PDF

Sound Source Localization using HRTF database

  • Hwang, Sung-Mok;Park, Young-Jin;Park, Youn-Sik
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.751-755
    • /
    • 2005
  • We propose a sound source localization method using the Head-Related-Transfer-Function (HRTF) to be implemented in a robot platform. In conventional localization methods, the location of a sound source is estimated from the time delays of wave fronts arriving in each microphone standing in an array formation in free-field. In case of a human head this corresponds to Interaural-Time-Delay (ITD) which is simply the time delay of incoming sound waves between the two ears. Although ITD is an excellent sound cue in stimulating a lateral perception on the horizontal plane, confusion is often raised when tracking the sound location from ITD alone because each sound source and its mirror image about the interaural axis share the same ITD. On the other hand, HRTFs associated with a dummy head microphone system or a robot platform with several microphones contain not only the information regarding proper time delays but also phase and magnitude distortions due to diffraction and scattering by the shading object such as the head and body of the platform. As a result, a set of HRTFs for any given platform provides a substantial amount of information as to the whereabouts of the source once proper analysis can be performed. In this study, we introduce new phase and magnitude criteria to be satisfied by a set of output signals from the microphones in order to find the sound source location in accordance with the HRTF database empirically obtained in an anechoic chamber with the given platform. The suggested method is verified through an experiment in a household environment and compared against the conventional method in performance.

  • PDF

Gender-specific cephalometric features related to obesity in sleep apnea patients: trilogy of soft palate-mandible-hyoid bone

  • Cho, Seok Hyun;Jeon, Jae-Yun;Jang, Kun-Soo;Kim, Sang Yoon;Kim, Kyung Rae;Ryu, Seungho;Hwang, Kyung-Gyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.58.1-58.8
    • /
    • 2019
  • Background: The aim of this study is to investigate the relationship between gender-specific and obesity-related airway anatomy in patients with obstructive sleep apnea (OSA) by using cephalometric analyses. Methods: We retrospectively evaluated 206 patients with suspected OSA undergoing polysomnography and anthropometric measurements such as body mass index, neck circumference, and waist-hip ratio. We checked lateral cephalometry to measure tissue landmarks including angle from A point to nasion to B point (ANB), soft palate length (SPL), soft palate thickness (SPT), retropalatal space (RPS), retrolingual space (RLS), and mandibular plane to hyoid (MPH). Results: Male with OSA showed significantly increased SPL (P = .006) compared with controls. SPL and MPH had significant correlation with apnea-hypopnea index (AHI) and central obesity. Female with OSA showed significantly increased ANB (P = .013) and SPT (P = .004) compared with controls. The receiver operating characteristic curves revealed that SPT in male and ANB and SPT in female were significant in model 1 (AHI ≥ 5) and model 2 (AHI ≥ 15). MPH was also significant for male in model 2. Conclusion: Male and female with OSA had distinct anatomic features of the upper airway and different interactions among soft palate, mandible, and hyoid bone.

A Study on Relationship Between TMD and Skeletodental Form in Long Face Patterns (장안모군에서 악관절 장애와 악안면 골격형태에 대한 연구)

  • Tae, Ki-Chul;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.29 no.1 s.72
    • /
    • pp.37-49
    • /
    • 1999
  • Forty-four females with normal temporomandibular joint were compared with fifty-one females with abnormal temporomandibular joint. An orthodontic study model and lateral cephalometric radiographic were used to investigate the relationship between TMD group and non-TMD group in long face patterns. The result were followed that ; 1. There were no significant in overbite and overjet amount. 2. A mandibular 1'st molar inclination and height to the mandibualr plane were more mesial inclined in TMD groups. 3. The functional factors, which were craniocervical posture , tongue posture and hyoid bone position, were no significant.

  • PDF

A STUDY OF POSITION AND SIZE OF CRANIAL BASE, MAXILLA, AND MANDIBLE IN TRUE SKELETAL CLASS III PATIENTS (진성 골격성 III급 부정교합에서 두개저, 상악, 하악의 위치 및 크기에 관한 연구)

  • Woo, Soon-Seop;Choi, Yong-Soo;Park, Won-Hee;Yoo, Im-Hag;Lee, Young-Soo;Shim, Kwang-Sup
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.28 no.1
    • /
    • pp.24-30
    • /
    • 2002
  • The facial patterns were expressed by the interrelation of variable factors such as heredity, function and environment. Such variable factors have an effect on the growth and development of maxillofacial bones. The malocclusions with skeletal discrepancies are caused by abnormal forms, sizes and positions of cranial base, maxilla and mandible. For the proper diagnosis and treatment planning, the analysis of such structures is necessary. Lateral cephalograms of 54 adults with class III malocclusion patients (test group) and 61 adults with normal occlusion (control group) were analyzed. Anteroposterior relations and sizes of cranial base, maxilla, mandible were estimated to compare with those of normal ones. In test group, the anterior cranial base length was within normal range, but posterior cranial base, maxilla and mandibular body were longer than those in control group, significantly. Based on the cranial base, the location of maxilla in test group was normal, but the location of mandible was more anterior than that in control. Based on the maxilla, the location of mandible was more anterior in test group than that in control. Both mandibular body and ramus anteroposterior lengths in test group were larger than those in control. Both mandibular plane angle and upper gonial angle were within normal range, but lower gonial angle was significantly high in test group.

MAXILLOFACIAL ESTHETICS BY THREE DIMENSIONAL FACIAL MORPHOMETRICS (삼차원적 안모형태의 미적분석)

  • Lee, Sang-Han;Kwon, Tae-Geon;Baek, Sang-Heum
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.6
    • /
    • pp.606-612
    • /
    • 2000
  • This study was performed to investigate the average anthropometric value of normal Korean men and women and to compare the preceding literatures. Additionally, average Korean profilogram was made to serve as a template for diagnosis of facial form. Eighty five Korean subjects(41 men, 44 women) aged between 21 to 26 were selected by members of the author's department on the basis of intact dentition and Class I occlusion without facial asymmetry. Frontal and lateral photographs were taken under standardized condition with digital camera. The image was magnified and adjusted according to the FH plane of cephalometric radiographs and digitized using personal computer. To compare the Western beauty, 25 esthetically pleasing female was selected to measure various angle and distance of the face. 1. It was possible to calculate the mean coordinate value of Korean normal samples which enables the direct visualization and comparison with the use of template. The method in this study was easy to applicate under the Microsoft $Windows^{(R)}$ bases. 2. Maxillary vertical hypoplasia, upper and lower lip protrusion was characteristics of Korean norms and relatively narrow alar base distance, less conspicuous nasal projection was observed. As the vermilion exposure and upper lip length was more than western norm, chin looks shorter than western. To compare the Korean and Western esthetically pleasing profile, facial convexity and nose was less conspicuous in Korean women.

  • PDF

Partial Layerwise-to-ESL Coupling Elements for Multiple Model Analysis (다중모델 해석을 위한 부분층별-등가단층 결합요소)

  • Shin, Young-Sik;Woo, Kwang-Sung;Ahn, Jae-Seok
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.22 no.3
    • /
    • pp.267-275
    • /
    • 2009
  • This paper presents the p-convergent coupling element on the basis of the ESSE(equivalent single layer shell element) and the PLLE(partial-linear layerwise element) to analyze laminated composite plates. The ESSE is formulated by the degenerated shell theory, on the other hand, the assumption of the PLLE is piecewise linear variation of the in-plane displacement and a constant value of lateral displacement across the thickness. The proposed finite element model is based on p-convergence approach. The integrals of Legendre polynomials and Gauss-Lobatto technique are chosen to interpolate displacement fields and to implement numerical quadrature, respectively. This study has been focused on the verification of p-convergent element. For this purpose, various finite element multiple models associated with the combination of ESSE and PLLE elements are tested to show numerical stability. The simple examples such as a cantilever beam subjected vertical load and a plate with tension are adopted to evaluate the performance of proposed element.