• Title/Summary/Keyword: Latent Area

Search Result 168, Processing Time 0.03 seconds

Development of Technology for Network Construction using Wide Area Energy (광역에너지이용 네트워크 구축 기술개발)

  • Kim, Lae-Hyun;Chang, Won-Seok;Hong, Jae-Jun
    • Journal of Energy Engineering
    • /
    • v.17 no.3
    • /
    • pp.125-138
    • /
    • 2008
  • In order to diversify energy source and to utilize it effectively, it requires to construct an integrated energy management system in a wide area. This research paper explores the core technology of network construction using wide area energy and applies the technology to the field. In specific, it examines the business model by developing l) construction technology of optimum integrated system for thermal supply on wide area network related IT technology, 2) technology of unutilized energy as heat pump using exhaust gas latent heat, and 3) thermal transportation and storage technology using various sources, and by evaluating the applicability and marketability of the model in the field.

Experimental Study on the Characteristics of Heat and Mass Transfer on the Teflon Coated Tubes (테프론 코팅 전열관 표면으로의 열 및 물질 전달 특성에 관한 실험적 연구)

  • Lee, Jang-Ho;Kim, Hyeong-Dae;Kim, Jung-Bae;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.8
    • /
    • pp.1051-1060
    • /
    • 2003
  • The heat and mass transfer on two kinds of tube surfaces (bare stainless steel tube and Teflon coated tube) in steam-air mixture flow are experimentally studied to obtain design data for the heat exchanger of the latent heat recovery from flue gas. In the test section, 3-tubes are horizontally installed, and steam-air mixture is vertically flowed from the top to the bottom. The pitch between tubes is 67mm, the out-diameter of tube is 25.4mm, and the thickness is 1.2mm ; blockage factor (cross sectional tube area over the cross sectional area of the test section) is about 0.38. All of sensors and measurement systems (RTD, pressure sensor, flow-meter, relative humidity sensor, etc.) are calibrated with certificated standard sensors and the uncertainty for the heat transfer measurement is surveyed to have the uncertainty within 7%. As experimental results, overall heat transfer coefficient of the Teflon (FEP) coated tube is degraded about 20% compared to bare stainless tube. The degradation of overall heat transfer coefficient of Teflon coated tube comes from the additional heat transfer resistance due to Teflon coating. Its magnitude of heat transfer resistance is comparable to the in-tube heat transfer resistance. Nusselt and Sherwood numbers on Teflon (FEP) coated surface and bare stainless steel surface are discussed in detail with the contact angles of the condensate.

Online anomaly detection algorithm based on deep support vector data description using incremental centroid update (점진적 중심 갱신을 이용한 deep support vector data description 기반의 온라인 비정상 탐지 알고리즘)

  • Lee, Kibae;Ko, Guhn Hyeok;Lee, Chong Hyun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.2
    • /
    • pp.199-209
    • /
    • 2022
  • Typical anomaly detection algorithms are trained by using prior data. Thus the batch learning based algorithms cause inevitable performance degradation when characteristics of newly incoming normal data change over time. We propose an online anomaly detection algorithm which can consider the gradual characteristic changes of incoming normal data. The proposed algorithm based on one-class classification model includes both offline and online learning procedures. In offline learning procedure, the algorithm learns the prior data to be close to centroid of the latent space and then updates the centroid of the latent space incrementally by new incoming data. In the online learning, the algorithm continues learning by using the updated centroid. Through experiments using public underwater acoustic data, the proposed online anomaly detection algorithm takes only approximately 2 % additional learning time for the incremental centroid update and learning. Nevertheless, the proposed algorithm shows 19.10 % improvement in Area Under the receiver operating characteristic Curve (AUC) performance compared to the offline learning model when new incoming normal data comes.

Experimental Research for Prevention of Stone Hazarding Guizhou, China (중국 귀주성 석막화 방지를 위한 실험적 연구)

  • Park, Jae Hyeon;Jun, Jaehong
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.11 no.2
    • /
    • pp.28-39
    • /
    • 2008
  • This study was conducted to evaluate the rehabilitation measures and select appropriate tree species and rehabilitation methods for rehabilitating the rock desert areas in Guizhou, China. The study was carried out during the periods from 2003 to 2006 and results are as follows. Afforestation site is classified as a dolomite sandstone hilly country, a halfstony hilly country, a karst physiognomy, a rock desertification farmland and an latent rock desertification farmland by soil type and rock desertification status. Total afforestation area of Xuiwen is 1,300ha and afforestation area of a dolomite sandstone hilly country, a halfstony hilly country, a karst physiognomy, a rock desertification farmland and an latent rock desertification farmland are respectively 104.0ha (8.0%), 146.6ha (11.3%), 200.5ha (15.4%), 705.7ha (54.3%) and 143.2ha (11.0%). Planted tree species were selected by five site types. Robinia pseudoacacia, Chamaecyparis obtusa, Thuja orientalis, Cupressus duclouxiana and Juniperus chinensis L. var. chinensis were planted in a dolomite sandstone hilly country and Choerospondias axillaris and Robinia pseudoacacia were planted in a halfstony hilly country. Cupressus duclouxiana, Zanthoxylum bungeanum, Lonicera fulvotomentosa, Ilex kudincila, Quercus aliena, Quercus variabilis, Choerospondias axillaris, Koelreuteria bipinnata, Cryptomeria japonica, Cinnamomum camphora and Cinnamomum bodinieri were planted in a karst physiognomy. Cupressus duclouxiana, Toona sinensis, Robinia pseudoacacia, Lonicera fulvotomentosa, Eucommia ulmoides, Ilex kudincha. Zanthoxylum bungeanum and Magnolia officinalis were planted in a rock desertification farmland. Lonicera fulvotomentosa, Juglans sinensis, Pyrus pyrifolia, Choerospondias axillaris, Prunus salicina and Diospyros Kaki was planted in an latent rock desertification farm land. Robinia pseudoacacia showed high survival rate in 2004 and 2005, but Zanthoxylum bungeanum and Cinnamomum camphora showed slightly low survival rate in 2004. Survival rate of planting species in 2005 was over 80% because some species which showed low survival in 2004 were changed with other species and a proper afforestation method was applied. Growth rate of tree species was evaluated by height and diameter growth rate. Cupressus duclouxiana showed a highest height growth rate in 2004. Toona sil1ensis, Choerospondias axillaris, Koelreuteria bipinnata, and Cinnamomum camphora showed almost 100% height growth rate in 2005, although they showed a negative height growth rate in 2004. Robinia pseudoacacia showed a good growth rate in the rock desertification farmland and the halfstony hilly country so it could give a commercial benefit like honey as well as an afforestation effect.

Determination of Service Areas and Operating Numbers for Free-floating Personal Mobility Sharing Services (First-mile과 Last-mile을 고려한 자유 주차방식(Free-floating) 개인형 이동장치 공유 서비스 권역 및 운영대수 결정)

  • Sang-Wook Han;Dong-Kyu Kim;Sedong Moon
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.23 no.2
    • /
    • pp.106-118
    • /
    • 2024
  • Interest in personal mobility has increased with the growing significance of first-mile and last-mile connectivity in smart mobility services. This study aims to propose a methodology for setting the service area of free-floating personal mobility sharing services and determining the optimal fleet size for the selected shared service area to address first-mile and last-mile challenges. We utilize population data, smart card data, and building data. Additionally, we estimate latent demand by incorporating age-specific and distance-specific utilization rates based on personal mobility device data. Along with the latent demand, we determine the service area based on locations of transit stops and buildings. We apply the proposed methodology to Yeongjong Island, Incheon. As a result, dense residential areas and popular beachside locations are designated as personal mobility sharing service areas. The fleet size for personal mobility in the dense residential service area is determined to be 1,022 units, while the fleet size for the beachside service area is set at 269 units.

An Observational Study on the Differences in Thermal Characteristics of the Upo Wetland and Converted Areas from Wetland to Paddy Field

  • Koo, Hyun-Suk;Jeon, Dae-Youn;Kim, Hae-Dong
    • Journal of the Korean earth science society
    • /
    • v.30 no.5
    • /
    • pp.622-629
    • /
    • 2009
  • This study intended to collect data for evaluating the meteorological value of Upo Wetland which is the largest wetland in the downstream of Nakdong River. The observations were conducted in summer at the Upo Wetland and its surrounding paddy field that is the converted areas from a wetland to a paddy field. The following results are obtained: 1) The temperature of Upo Wetland area was $1^{\circ}C$ lower than the surrounding area during the day while it was a little higher during the night.; 2) The maximum wind speed in the Upo Wetland area was 3.5 m/s which is stronger than 1.6 m/s of its surrounding area. The south wind was observed in the farmland for most of the day while north winds and south winds alternated between day and night in Upo Wetland.; 3) In heat budget analysis, Upo Wetland was wasted in the form of latent heat rather than sensible heat in daytime.

Analysis of Office Building HVAC System Drawings (사무용 건축물 공조설비 설계도서 분석)

  • Park, Jong-Il;Kim, Se-Hwan;Kim, Dong-Kyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.11
    • /
    • pp.776-781
    • /
    • 2007
  • Optimized capacity of equipments are essential for energy saving and low cost construction and operation. So we must use proper design data for HVAC system design. We investigated for architectural data, equipment capacity, cooling and heating load design criteria of 52 office buildings. Following research results were obtained by carrying out each task. Office building effective area rate is 63%. The average building cooling load of South Korea is $140W/m^2$ and average heating loads in Seoul and Pusan area are $120{\sim}130W/m^2$ and $70{\sim}80W/m^2$. We also analysised HVAC design criteria. Person ratio in effective building area is $0.2person/m^2$, sensitive and latent heat loads of a person are 60W and 65W, light and equipment loads of office buildings are $25W/m^2$ and $20W/m^2$.

Difference in Happiness Level of Workers Depending on the Leadership Type (상사의 리더십 유형에 따른 근로자의 행복 수준 차이)

  • Cho, Hyun-Jung;Lee, Hyunmin;Lee, Yujin
    • Knowledge Management Research
    • /
    • v.23 no.3
    • /
    • pp.111-128
    • /
    • 2022
  • The purpose of this study is to identify the difference in happiness of workers depending on the perceived leadership types in a big company in Korea. The research objectives were 1) to identify the managers' leadership types which their workers perceive in a big corporate organization, and 2) to analyze the difference in a degree of workers' happiness according to the types of manager's leadership. To this end, a latent profile analysis was conducted. The research results are as follows. There were four types of leadership: 1) the Elite type which shows perfect ability in each area of self-management, task management, people management, and organization management, 2) the Competent type which has excellent self-management skills, good levels of task management and organizational management skills, but relatively poor people management skills, 3) the Self-centered type with the average levels of self-management, task management and organization management but with the poor level of people management skills, and lastly 4) the Passive type with the average level of self-management, somewhat low levels of task management and organization management skills and the poor level of people management skills. In addition, there was a statistically significant difference in the degree of happiness of workers according to the manager's leadership type. This study is meaningful in that it presented the leadership types of managers in a big company through the latent profile analysis and provided its implications on the workers' happiness.

A Simple Model for Dispersion in the Stable Boundary Layer

  • Kang Sung-Dae;Kimura Fujio;Lee Hwa-Woon;Kim Yoo-Keun
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.1 no.1
    • /
    • pp.35-43
    • /
    • 1997
  • Handling the emergency problems such as Chemobyl accident require real time prediction of pollutants dispersion. One-point real time sounding at pollutant source and simple model including turbulent-radiation process are very important to predict dispersion at real time. The stability categories obtained by one-dimensional numerical model (including PBL dynamics and radiative process) are good agreement with observational data (Golder, 1972). Therefore, the meteorological parameters (thermal, moisture and momentum fluxes; sensible and latent heat; Monin-Obukhov length and bulk Richardson number; vertical diffusion coefficient and TKE; mixing height) calculated by this model will be useful to understand the structure of stable boundary layer and to handling the emergency problems such as dangerous gasses accident. Especially, this simple model has strong merit for practical dispersion models which require turbulence process but does not takes long time to real predictions. According to the results of this model, the urban area has stronger vertical dispersion and weaker horizontal dispersion than rural area during daytime in summer season. The maximum stability class of urban area and rural area are 'A' and 'B' at 14 LST, respectively. After 20 LST, both urban and rural area have weak vertical dispersion, but they have strong horizontal dispersion. Generally, the urban area have larger radius of horizontal dispersion than rural area. Considering the resolution and time consuming problems of three dimensional grid model, one-dimensional model with one-point real sounding have strong merit for practical dispersion model.

  • PDF

Comparison of Surface Fluxes Based on Landuse Characteristics Near Gangjeong-Goryeong Weir of the Nakdong River (낙동강 강정고령보에서 관측된 플럭스의 지표면에 따른 특성 비교)

  • Kahng, Keumah;Koo, Hae-Jung;Byon, Jae-Young;Park, Young-San;Jung, Hyun-Sook
    • Journal of the Korean earth science society
    • /
    • v.34 no.6
    • /
    • pp.561-574
    • /
    • 2013
  • This study investigates energy fluxes measured near Gangjeong-Goryeong Weir of the Nakdong River of South Korea for more than a year, from July 2011 to September 2012, in order to analyze the applicability of the data for future impact analyses. Each of the two study sites is located in a rural area, surrounded by agricultural fields, and an urban industrial area. Sensible and latent heat fluxes are analyzed according to the wind direction. In the summertime, when the wind blows from the river, sensible heat tends to decrease and latent heat tends to increase at both sites. This result is considered to be caused by moisture transfer from the river. Bowen ratio, energy balance closure, momentum flux, and stability are analyzed as well. The Bowen ratio of the rural agricultural site turns out higher than that of the urban site regardless of the season. The energy balance closure is higher at the agricultural site compared to the urban area, which is mainly due to exclusion of the storage term calculation at the urban site. The momentum flux is greater at the urban site both in winter and summer. The instability lasts longer during daytime and in the summertime, when there is a strong turbulence. The data from these sites are appropriate to be used in analyzing the impact of river in surrounding areas for future studies.