• Title/Summary/Keyword: Late complication

Search Result 250, Processing Time 0.029 seconds

A Case of Acute Eosinophilic Pneumonia after Hematopoietic Stem Cell Transplantation (혈연간 동종 조혈모세포 이식 후 이식편대숙주질환과 함께 발생한 급성 호산구성 폐렴 1예)

  • Park, Hwan-Sung;Ok, Tae-Jin;Kim, You-Jae;Kim, Guang-Un;Park, So-Eun;An, Ji-Hyun;Kim, Yun-Ku;Jeong, Jae-Ho;Kim, Su-Jeong;Lee, Yu-Mi;Lee, Ho-Su;Kang, Bo-Hyoung;Kim, Ga-Hee;Kim, Dae-Young;Kim, Woo-Sung;Kim, Dong-Soon;Song, Jin-Woo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.71 no.6
    • /
    • pp.459-463
    • /
    • 2011
  • Pulmonary complications occur in 40~60% of patients who receive hematopoietic stem cell transplantation (HSCT) and are a source of substantial morbidity and mortality. Acute eosinophilic pneumonia (AEP) is an uncommon, non-infectious pulmonary complication occurring in HSCT recipients. We now report the case of a 52-year-old man with AEP who was treated with allogenic HSCT due to acute myeloid leukemia. He complained of fever, cough and dyspnea 390 days after allogenic HSCT. He also had skin and hepatic graft versus host disease (GVHD). Hypoxemia, diffuse pulmonary infiltrates on a chest x-ray and eosinophilia in bronchoalveolar lavage fluid were also noted in several tests. His symptoms, pulmonary infiltrates, hepatic dysfunction and skin lesions rapidly improved after treatment with corticosteroid therapy. Our case supports the idea that AEP is a late phase non-infectious pulmonary complication and one of the manifestations of chronic GVHD.

Clinical Result of Aortic Valve Replacement (대동맥판막 치환술의 임상성적)

  • 최순호;양현웅;김은규;최종범
    • Journal of Chest Surgery
    • /
    • v.31 no.6
    • /
    • pp.591-597
    • /
    • 1998
  • Background: The aim of the current study was to analyze the early and intermediate-term performance of aortic valve replacement. Material and Method: Between January 1986 and January 1996, records of 61 consecutive patients who had received aortic valve replacement were reviewed. 38 were male and 23 were female patients, ranging from 10 to 71 years of age(mean: 40.5${\pm}$11.2). Results: The early death rate was 4.9%(3/61). A thorough follow-up rate of 93.1% was accomplished in these 58 patients who left the hospital(mean: 51.5${\pm}$32.0 patient-months) under the assistance of the same operator. Three of these patients who left the hospital died. The late death rate was 5.2%(3/58). Five patients experienced anticoagulant-related hemorrhage(all were minor). Three patients had thromboembolic episodes. There was no clinical evidence of hemolysis and structural failure of valves used. Of those patients who survived, the NYHA functional class improved significantly. Linearized rate were 1.58%/patient-year and 2.0%/patient-year respectively for thromboembolism and anticoagulant-related hemorrhage. The 10 year actuarial survival rate was 83.6%. Conclusion: This early and intermediate-term follow-up suggests that the mechanical valve is a reliable and durable prosthesis with good hemodynamic function and low rate of prosthesis-related complication.

  • PDF

Long-term clinical results of the xenograft cardiac valves (이종조직판막의 장기임상성적)

  • 김종환
    • Journal of Chest Surgery
    • /
    • v.20 no.2
    • /
    • pp.289-299
    • /
    • 1987
  • A total of 1,239 patients had cardiac valve replacement using 1,514 substitute valves at Seoul National University Hospital from 1968 to 1986. Of the total substitute vales, 84.9% were the glutaraldehyde-treated xenograft valves. Six hundred ninety-four patients who had 820 bioprosthetic tissue valves were studied for their clinical characteristics. They were a total and consecutive cases to the end of the study. Four hundred sixty-four patients had the lonescu-Shiley pericardial valves: MVR 291, AVR 66 and MVR+AVR 107; 163 had the Hancock porcine valves; 46 had the Angell-Shiley porcine valves; and 21 had the Carpentier-Edwards porcine valves. Five hundred forty patients underwent single valve replacement: MVR 460, AVR 76 and TVR 4; 154 had multiple valve replacement: MVR+AVR 141, MVR+TVR 12 and one triple valve replacement. Additional surgery was necessary in 22.3% of the cases. Operative mortality rate within 30 days of surgery was 6.77% for the total patients: 5.2% and 4.2% with MVR, 13.6% and 12.5% with AVR, and 7.5% and 7.4% with MVR+AVR using the lonescu and the Hancock valves respectively. A linealized annual late mortality rate was 2.56%/patient-year. Six hundred forty-three operative survivors were followed up for a total of 1482.7 patient-years [a mean 27.7 months], and the follow-up rate was 67.7%. The Idealized complication rates were: 2.02% emboli/patient-year, 0.94% bleeding/patient-year, 1.21% endocarditis/patient-year, and 3.84% overall valve failure/patient-year. A linealized rate of primary tissue failure was 0.87%/patient-year. Actuarial survival rates including the operative mortality were: 87.8*2.6%, 82.3*4.9% and 82.2*4.7% with MVR, AVR and MVR+AVR using the lonescu valves at 4 years after surgery respectively; and they were 88.0*4.1% with MVR at 8 years, 82.3*4.9% with AVR at 4 years and 84.9*7.0% with MVR+AVR at 6 years after surgery using the Hancock valves respectively. Probabilities of freedom from thromboembolism were 89.8*6.3% with MVR using the lonescu valves at postoperative 5 years and 89.2*3.8% with MVR using the Hancock valves at postoperative 7 years, and 93.3*3.9% with AVR using the lonescu valves at postoperative 5 years. None had embolic complication after AVR using the Hancock valves. Probabilities of freedom from valve failure [according to the Stanford criteria] were 81.0*7.1% with MVR using the lonescu valves at postoperative 4 years and 57.4*12.5% with MVR using the Hancock valves at postoperative 9 years. These clinical results prove the excellent antithrombogenicity of the glutaraldehyde-treated xenograft substitute valves and confirm the previously speculated rate of tissue failure. At the present situation, it may be concluded that there is a room for the further development of more durable bioprosthetic valves.

  • PDF

Management of Post-Pneumonectomy Empyema (전폐절제술후 생긴 농흉의 치료)

  • Song, Jong-Phil;Chung, Sung-Hyock;Hur, Yong;Kim, Byung-Yul;Lee, Jeong-Ho;Ahn, Wook-Su
    • Journal of Chest Surgery
    • /
    • v.32 no.3
    • /
    • pp.276-280
    • /
    • 1999
  • Background: Post-pneumonectomy empyema(PPE) is an uncommon but a serious complication. The management remains as challenge for general thoracic surgeons. Material and Method: During the period of January 1990 to December 1996, we evaluated the results of 20 patients with post-pneumonectomy empyema. Result: Sex ratio were 15 male and 5 female patients with mean age of 41.5${\pm}$21.5 yrs. The occurrence ratio of left to right side was 8:12. The most common disease for prior pneumonectomy was pulmonary tuberculosis. The duration between pneumonectomy and PPE was variable in 1 month to 6yrs. Fever was the most frequent symptom and S. aureus was the most frequent pathogen. In 13 cases, there were combined with BPF. Four patients underwent trans-sternal closure, and Clagett procedure was performed. There was one recurrence that later underwent muscle plombage and omentopexy later. Nine patients underwent omentopexy, muscle plombage and thoracoplasty. There were 7 cases that were not combined with BPF. All 7 patients underwent thoracoplasty, and two of them were combined with muscle plombage. Mean follow-up duration is 40${\pm}$32.3 months. There were no late deaths nor recurrences of PPE. Conclusion: We conclude that early diagnosis and proper drainage in PPE patients are important in its initial stage of management, and also management is completely achieved in thoracoplasty with muscle plombage or omentopexy.

  • PDF

Durability of Xenograft Cardiac Valves (이종조직 판막의 내구성)

  • 김종환
    • Journal of Chest Surgery
    • /
    • v.25 no.5
    • /
    • pp.494-503
    • /
    • 1992
  • The durability of the xenograft cardiac substitute valves is of a great concern on the clinical grounds. Four groups of tc tal and consecutive patients to the end of study operated on between 1976 and 1984 were Group ISM, 291 patients of MVR, ISA, 65 patients of AVR, and ISMA, 107 patients of MVR+AVR with the standard Ionescu-Shiley bovine pericardial valve, and H, 163 patients of valve replacement with the Hancock porcine aortic vlave. Operative mortality was 5.2%[ISM], 10.8%[ISA], 7.5%[ISMA] and 6.1%[H]. Early survivors were followed up for a total of 1148.3 patient-years[pt-yrs] [ISM], 271.2 pt-yrs [ISA], 488.1 pt-yrs[ISMA] and 822.9 pt-yrs[H]. Linearized late mortality was 2.1% /pt-yr [ISM], 1.l%/pt-yr[ISA], 1.8%/pt-yr[ISMA] and 1.8% /pt-yr[H]. Thromboembolic complication was experienced at the linearized rate of 1.045% /pt-yr [ISM], 1.475%/pt-yr[ISA], 0.615%/pt-yr[ISMA] and 1.822%/pt-yr[H], and bleeding complication at the rate of 0.871% /pt-yr[ISM], 0.63% /pt-yr[ISA], 0.205% /pt-yr [ISMA] and 0.729%a /pt-yr[H], respectively. Prosthetic valve endocarditis occurred at the rate of 0.610% /pt-yr[ISM], 1.475% /pt-yr[ISA], 1.639% /pt-yr[ISMA] and 0.972% /pt-yr[H]. The linearized annual incidence of primary tissue failure was 1.655%/pt-yr[ISM], l. 475%/pt-yr[ISA], 1.639% /pt-yr[ISMA], 2.187% /pt-yr[H] and 1.785% /pt-yr[Group HM : MVR with Hancock valve]. The incidence of tissue failure was significantly high in the patients younger than 30 years of age compared with the older patients. The actuarial survival was 87.7$\pm$2.5% at 10 years[ISM], 94.3$\pm$3.2% at 11 years[ISA], 89.6$\pm$3.4% at 10 years[ISMA] and 81.3$\pm$6.6% at 12 years[HM], The freedom from thromboembolism was 93.2$\pm$2.0% at 10 years[ISM], 90.6$\pm$4.6% at 11 years[ISA], 95.8$\pm$2.6% at 10 years[ISMA] and 80.9$\pm$11.1% at 12 years[HM], And, the freedom from primary tissue failure was 84.2$\pm$3.8% and 28.1$\pm$23.0% at 9 and 10 years[ISM], 60.4$\pm$16.9% at 11 years[ISA], 62.3$\pm$12.7 at 10 years[ISMA] and 65.6$\pm$9.8% at 12 years[HM]. In conclusion, the standard Ionescu-Shiley and the Hancock bioprosthetic valves are excellent in their antithrombogenicity and long-term survival. However, the features of the structural failure with the prolonged follow-up beyond 10 years appear to be guarding, and the clinical indications of these bioprostheses seem to be quite limited.

  • PDF

A 6 Year Experience with the St. Jude Medical Cardiac Valve Prosthesis (St. Jude Medical 판을 이용한 심판막 치환술의 성적)

  • 조광현
    • Journal of Chest Surgery
    • /
    • v.25 no.3
    • /
    • pp.296-306
    • /
    • 1992
  • A 6 year experience with the bileaflet St. Jude Medical valve is reported. Between Feb. 1986 and Dec. 1992, 68 patients received 87 such valves[36 mitral, 13 aortic, and 19 double mitral-aortic valve replacements]. The results are summarized as follows 1. There were 35 male and 33 female patients ranging in age from 17 to 55 years the mean age of 35.3 $\pm$ 9.7 years. 2. The mean aortic clamp time[ACT] of the MVR, AVR and DVR groups were 91.5$\pm$16.4, 117.2$\pm$28.7 and 165.5$\pm$24.1 minutes. The mean total bypass time [TBT] of the MVR, AVR and DVR groups were 112.8$\pm$19.5, 134.7$\pm$31.4 and 192.2$\pm$28.5 minutes. 3. Eighty seven valves were used [55 mitral site, 32 aortic site]. 31mm[20], 33mm[15], 29mm[15], 27mm[2], 25mm[2] and 35mm[1] were used in mitral site and 23mm[13], 21mm[8], 19mm[7] and 25mm[4] were used in the aortic site. In the DVR, there were valve combinations such as 4 cases of M[29mm]-A[19mm], 4 of M[31mm]-A[23mm], 3 of M[33mm]-A[23mm] and others. 4. Preoperative NYHA functional classes were II [3 cases], III [46 cases], IV[19 cases] and improved to I [52 cases] and Il [13 cases] postoperatively. 5 Early postoperative complications were occurred in 15 cases[2Z.l%] and there were LOS in 5 cases[7.4%], arrythmia [3 cases], wound infection [2 cases], hepatitis [2 cases], sudden cardiac arrest [2 cases] and postoperative bleeding [1 case]. The early hospital death was occurred in 3 cases[4.4%] with LOS [1 case] and sudden cardiac arrest [2 cases]. 6. Mean follow-up time of survival cases[65 cases] was 31.3$\pm$21.9 months and the total follow-up time was 169.8 patient-years. Late postoperative complications were occurred in 4 cases[2 thromboembolism, 1 paravalvular leak, 1 thromboembolism br paravalvular leak, 1 valve endocarditis] with the occurrence rate as 2.35% per patient-years. Reoperation was performed in 2 cases [1 paravalvular leak, 1 left atrial thrombus] and there was one [1.5%] late valve related death. Therefore the 6 year complication free rate was 90.6% and 6 year actuarial survival rate was 98.3$\pm$1.7%. On the basis of this experience and the results, SJMvalve appears to be one of the best performing mechanical prosthesis currently available, in terms of both hemodynamics and lower complications with warfarin antioagulation.

  • PDF

Patterns of Failure According to Radiation Treatment Technique in the Parotid Gland Cancer (이하선암의 술후 방사선치료시 방사선치료 방법에 따른 치료 실패 양상 분석)

  • Lee Sang-Wook;Lee Chang-Geol;Keum Ki-Chang;Park Cheong-Soo;Choi Eun-Chang;Shin Hyun-Soo;Chu Sung-Sil;Lee Suk;Cho Kwang-Hwan;Suh Chang-Ok;Kim Gwi-Eon
    • Korean Journal of Head & Neck Oncology
    • /
    • v.16 no.2
    • /
    • pp.167-171
    • /
    • 2000
  • Objectives: To compare the outcomes of treatment with a focus on the effectiveness of the two primary techniques of radiation used for treating parotid gland malignancies. Materials and Methods: A retrospective analysis of 70 patients with parotid gland cancer treated between 1981-1997. Radiation was delivered through an ipsilateral field of high energy electron and photon in 37 patients(52.9%). Two wedge paired photon was used to treat in 33 patients(47.1%). The median dose was 60 Gy, typically delivered at 1.8-2.0Gy per fraction. The median follow-up times for surviving patients was 60 months. Results: The overall and disease free 5 year survival rates were 71.6% and 69.5%, respectively. Wedge paired photon and photon-electron treatment disease tree 5 year survival rates were 61.1% and 80.5%, respectively. Overall local failure rate was 18.6%. Local failure rate of wedge paired photon technique was higher than that of mixed beam technique. Late complication rate was 37.1%, but most of them were mild grade. Conclusion: Techniques of radiation were associated with local control. The technique of using an ipsilateral field encompassing the parotid bed and treated with high energy electrons often mixed photons was effective with minimal severe late toxicity. To irradiate deep sited tumors, we consider 3-D conformal treatment plan for well encompassing the target volume.

  • PDF

Four Year Experience with Valve Replacement of Valvular Heart Diseases (심장판막 치환술후 단기 추적성적)

  • 류한영
    • Journal of Chest Surgery
    • /
    • v.23 no.6
    • /
    • pp.1180-1190
    • /
    • 1990
  • 96 patients underwent cardiac valve replacement for valvular heart diseases consecutively between February 1986 to February 1990 in the Department of Thoracic and Cardiovascular Surgery of Yeungnam University Hospital. The follow up period was between 6 months and 4.5 years postoperatively[mean 23.4$\pm$13.1 months]. 75 cases got mitral valve replacement, 6 cases, aortic valve replacement, 15 cases, double valve replacement. 30[31.2%] patients were male and 66[68.8%] were female and the age ranged from 14 to 66 years old. Early hospital death within 30 days postoperation were 5 patients[5.2%], consisting of by low cardiac output in 2, infective endocarditis in 1, multiple organ failure with sepsis in 1 patient. There was no late postoperative death. Most common early postoperative complication was wound disruption [8.7%] and then low cardiac output, pneumothorax, pleural effusion in order. Most common late postoperative complications were minor bleeding episodes[8.7%] related to anticoagulant therapy which were consisted of frequent epistaxis in 3, gum bleeding in 2, hemorrhagic gastritis in 1, hypermenorrhea in 1, hematoma in right arm in 1 patient. Valve-related complications included valve thrombosis [1.6%/ patient-year], valve failure due to pannus formation[1.1% /patient-year], prosthetic valve endocarditis[1, 1%o/patient-year] and minor anticoagulant hemorrhage[4.4% /patient-year]. 5 cases of reoperations were performed in 4 patients due to valve failure and all of them were in the mitral positions[2.7% /patient-year]. Cardiothoracic ratios in the chest X-ray decreased at the 6th month and 1st year postoperation in all patients. But in New York Heart Association[NYHA] functional class IV, no change in cardiothoracic ratio was found between 6 months and 1 year postoperation. In the echocardiogram, the size of the cardiac chambers decreased, but ejection fraction increased postoperatively in each functional class. In the electrocardiogram, decreases were found in the incidence of atrial fibrillation, left atrial enlargement, left ventricular hypertrophy with right bundle branch block increasing postoperatively in each functional class. The actuarial survival rate was 98.4% for all patients, 98.7% for mitral valve replacement, 83.8% for aortic valve replacement, and 80% for double valve replacement at the end of a 4.5 year follow up period. Meanwhile the actuarial freedom rate was 91.5% for prosthetic valve endocarditis, 91.6% for thromboembolism, 89.0% for prosthetic valve failure and 83.7% for minor anticoagulant hemorrhage. Preoperative NYHA class III and IV were 75% of all patients, but 95% of all patients were up graded to NYHA class I and II postoperatively.

  • PDF

Clinical Review of Totally Implantable Venous Catheter (완전 거치형 정맥도관의 임상분석)

  • Kim, Jung-Tae;Oh, Tae-Yoon
    • Journal of Chest Surgery
    • /
    • v.40 no.10
    • /
    • pp.691-695
    • /
    • 2007
  • Background: The introduction of central venous catheters in 1979 has aided the administration of chemotherapy to oncologic patients. We analyzed the clinical reviews and complications of totally implantable venous catheters in an effort to achieve optimal management. Material and Method: We retrospectively studied 100 cases with totally implantable venous catheter at our hospital and we report the results. Result: 100 totally implantable venous catheters were placed in the right subclavian vein in 74 cases (74%), the left subclavian vein in 21 cases, the right jugular vein in 3 cases, the left jugular vein in 1 case and the right femoral vein in 1 case. The immediate complications were 5 cases in malposition of the catheter and 5 cases of arterial puncture. The late complications were 1 case of subclavian vein thrombosis, which was treated with anticoagulation, and 2 cases of pinch-of syndrome. There were no other early or late complications. Conclusion: The low rate of complications in this study confirms the safety and convenience of using totally implantable venous catheter in patients undergoing prolonged chemotherapy. Yet because Infection, thrombosis, and catheter fracture are the most common long term complications of totally implantable venous catheters, early diagnosis and management of these problems can prevent severe complications.

The Clinical Results of Open Heart Surgery with Coronary Artery Bypass Grafting (관상동맥 우회로 조성수술을 병행한 개심수술의 임상성적)

  • 유경종;강면식
    • Journal of Chest Surgery
    • /
    • v.29 no.2
    • /
    • pp.171-176
    • /
    • 1996
  • From March, 1983 to June, 1994, twenty-two patients underwent coronary artery and combined operations. The ages of the patients ranged from 42 years to 72 years (mean 60.4$\pm$8.2 years). There were 17 male and 5 female patients. The left ventricular (LV) ejection fraction ranged from 25% to 65% (mean 46.9$\pm$14.2%). Nine patients had mechanical complication of myocardial infarction (MI), of which 5 were LV aneurysm, 3 ventricular septal defect and 1 mitral regurgitation. Nine patients had rheumatic valvular heart disease of whom 7 with aortic valve disease and 2 with mitral valve disease. Two other patients had left atrial thrombi, only one with atrial septal defect a d another with aneurysm of ascending aorta. An average of 2.1$\pm$1.0 bypasses was done, ranging from one to four. There were 3 postoperative complications; 2 perioperative MI and 1 leg wound infection. Among complicated patients, mortality was 1 patient (4.5%) due to low cardiac output syndrome after perioperative MI. With 3 to 136 months follow-up (mean 41.1$\pm$40.2 months), late mortality was 1 patient due to cerebral vascular accident. Among long-term survivors, all patients are in New York Heart Association functional class I or II. Although the number of patients was small, our surgical results were favorable. Therefore we think that coronary revascularization combined with heart operation does not increase the operative risk when associated coronary artery disease is present, and it reduces the occurrence of late death.

  • PDF