• 제목/요약/키워드: Laser vibrometer

검색결과 163건 처리시간 0.021초

전전형 평판 공진자의 동특성 (The Dynamic Characteristics of an Electrostatic Plate Resonator)

  • 정옥찬;양상식
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.1084-1088
    • /
    • 1995
  • In this paper, an electrostatic plate resonator with four corrugated bridges and another with four flat ones have been fabricated and tested by the electrostatic actuation. The resonators consist of one rigid plate and four bridges. Boron diffusion process and anisotropic etch process with EPW are mainly used to fabricate the resonators. The dynamic characteristics of the fabricated resonators are obtained by measuring the velocity of the center of the rigid plate using a laser vibrometer. The results show that the deflection of the resonator with the corrugated bridges is larger than the resonator with the flat ones. It has been confirmed that the corrugated structure releases the residual tensile stress in the bridges resulted from the diffusion process.

  • PDF

회의실 유리창 진동음의 음성 명료도 분석 (Speech Intelligibility Analysis on the Vibration Sound of the Glass Window of a Conference Room)

  • 김희동;김윤호;김석현
    • 한국소음진동공학회논문집
    • /
    • 제17권4호
    • /
    • pp.363-369
    • /
    • 2007
  • The purpose of the study is to obtain acoustical information to prevent eavesdropping of the glass window. Speech intelligibility was investigated on the vibration sound detected from the glass window of a conference room. Objective test using speech transmission index(STI) was performed to estimate quantitatively the speech intelligibility. STI was determined based on tile modulation transfer function(MTF) of the room-glass window system. Using Maximum Length Sequency(MLS) signal as a sound source, impulse responses of the glass window and MTF were determined by signals from accelerometers and laser doppler vibrometer. Finally, speech intelligibility of the interior sound and window vibration were compared under different sound pressure levels and amplifier gains to confirm the effect of measurement condition on the speech intelligibility.

피에조 잉크젯의 셀프 센싱 검출 및 응용 (Self-sensing measurement of piezo inkjet and its Applications)

  • 권계시;김우식;김상일;신승주;김성진
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.366-372
    • /
    • 2007
  • Self-sensing measurement of piezo inkjet and its application are discussed. The pressure wave inside the inkjet dispenser was measured by current measurement due to self-sensing capability of PZT. The pressure wave measured from current was verified by commercially available laser vibrometer. Here, two applications using self-sensing signal were discussed: waveform design for high speed jetting and condition monitoring. For waveform design, two pulse waveform was designed based on self-sensing signal such that the pressure wave after droplet formation can be minimized. For condition monitoring, self-sensing signal was shown to be effective in detecting air bubble trapped in inkjet printhead.

  • PDF

유리창 도청방지 장치의 성능평가 (Performance Estimation of a Window Shaker)

  • 김석현;김희동;허욱
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.649-654
    • /
    • 2007
  • Eavesdropping prevention performance is evaluated on a commercial window shaker, which is used to prevent a glass window from eavesdropping. Speech transmission index (STI) is introduced in order to estimate quantitatively the speech intelligibility of the sound detected on the glass window. Objective test by IEC standard using modulation transfer function (MTF) is performed to determine STI. Using Maximum Length Sequency (MLS) signal as a sound source, MTF is measured by accelerometers and laser doppler vibrometer. STI under different level of disturbing wave are compared to confirm the disturbing effect on the speech intelligibility.

  • PDF

심벌 액츄에이터의 변위특성에 대한 인가전압 의존성 (Applied Voltage Dependence of the Displacement Characteristics on The Cymbal Actuator)

  • 최성영;김진수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 추계학술대회 논문집
    • /
    • pp.235-238
    • /
    • 1998
  • In this study, the cymbal actuators with brass and bronze endcap at various endcap thickness were fabricated, and then the displacement vs applied voltage relation and position from the center of endcap relation were investigated The displacement values of all cymbal actuator were measured using laser vibrometer. The displacement of the cymbal actuator was increased linearly with increasing applied voltage. The cymbal actuator with 0.15mm thick brass endcap show approximately 1.3$\mu\textrm{m}$ displacement more than cymbal actuator with uniformly thick bronze endcap. The displacement about 3mm in diameter at the center of the endcap was uniform and rapidly decreased away from 3mm in diameter at the center of the endcap.

  • PDF

자기변형 박막을 이용한 마이크로 펌프의 제작과 시험 (Fabrication and Test of a Micro Pump with a Magnetostrictive diaphragm)

  • 서지훈;정옥찬;양상식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1017-1019
    • /
    • 1998
  • In this paper, the fabrication of a micropump with two giant magnetostrictive films of Sm-Fe and Tb-Fe is presented. The pump consist of one silicon wafer and one cover glass. The micropump consists of an actuator diaphragm, a paired nozzle and diffuser, and two through holes. The Structure of the micropump is fabricated by the chemical vapor deposition, the etching and the sputtering of the magnetostrictive films. The deflection of the actuator measured diaphragm is measured by using the laser vibrometer and the flow rate of the micro pump is observed by using a video microscope.

  • PDF

정전형 미소 평판 공진자의 설계 및 제작 (Design and Fabrication of an Electrostatic Microplate Resonator)

  • 정옥찬;양상식
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권6호
    • /
    • pp.494-502
    • /
    • 1999
  • This paper represents an electrostatic micro plate resonator which consists of a rigid plate suspended with four bridges and a counter electrode. The bridges of the resonator are designed corrugated so that the residual stress are released. The FEM simulation results confirmed that the deflection characteristic of the corrugated bridge is hardly affected by the initial residual tensile stress. One resonator with the corrugated bridges and the other with the flat bridges were fabricated by the boron diffusion process and the anisotropic etch process. The vertical deflection of the fabricated electrostatic resonator was measured with a laser vibrometer, and the data were compared with the calculation results. The deflection of the resonator with the flat bridges is smaller than the deflection of that with the corrugated ones because of the residual stress. The residual stress release effect was confirmed by the fact that the measured deflection of the resonator with the corrugated bridges in close to the calculated deflection of the resonator with the flat ones with the initial stress neglected.

  • PDF

PMN-PZ-PT 세라믹스를 이용한 적층형 액츄에이터의 변위특성 (Electric-Field-Induced Strain Properties of Multi Layer Ceramic Actuator Using PMN-PZ-PT Ceramics)

  • 하문수;정순종;고중혁;송재성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.620-623
    • /
    • 2003
  • Non-linear behaviors of multilayer piezoelectric ceramic actuator (MCA) were investigated under electrical and mechanical stress. DC 100 V bias was applied to the MCA to obtain displacement. Laser vibrometer, which using Doppler effect, was employed to characterize displacement caused by $d_{33}$ mode of MCA. To understand this non-linear behavior of MCA, displacement was measured and compared under different load states. By increasing load, electric field-induced strain and piezoelectric constant($d_{33}$) of MCA was decreased. We attribute this phenomenon to the domain wall motion and depoling of MCA under heavy load.

  • PDF

양단이 고정된 빔형 다결정 3C-SiC 마이크로 공진기의 제작과 그 특성 (Fabrication of Polycrystalline SiC Doubly Clamped Beam Micro Resonators and Their Characteristics)

  • 정귀상;이태원
    • 한국전기전자재료학회논문지
    • /
    • 제22권4호
    • /
    • pp.303-306
    • /
    • 2009
  • This paper describes the characteristics of polycrystalline 3C-SiC doubly clamped beam micro resonators. The polycrystalline 3C-SiC doubly clamped beam resonators with $60{\sim}100{\mu}m$ lengths, $10{\mu}m$ width, and $0.4{\mu}m$ thickness were fabricated using a surface micromachining technique. Polycrystalline 3C-SiC micro resonators were actuated by piezoelectric element and their fundamental resonant frequency was measured by a laser vibrometer in vacuum at room temperature. For the $60{\sim}100{\mu}m$ long cantilevers, the fundamental frequency appeared at $373.4{\sim}908.1\;kHz$. The resonant frequencies of doubly clamped beam with lengths were higher than simulated results because of tensile stress. Therefore, polycrystalline 3C-SiC doubly clamped beam micro resonators are suitable for RF MEMS devices and bio/chemical sensor applications.

다결정 3C-SiC 마이크로 공진기 제작과 그 특성 (Fabrication and characterization of polycrystalline 3C-SiC mocro-resonators)

  • 이태원;정귀상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.250-250
    • /
    • 2008
  • This paper describes the resonant characteristics of polycrystalline SiC micro resonators. The $1{\mu}m$ thick polycrystalline 3C-SiC cantilevers with different lengths were fabricated using a surface micromachining technique. Polycrystalline 3C-SiC micro resonators were actuated by piezoelectric element and their fundamental resonance was measured by a laser vibrometer in vacuum at room temperature. For the 100 ~ $40{\mu}m$ long cantilevers, the fundamental frequency appeared at 147.2 kHz - 856.3 kHz. The $100{\mu}m$ and $80{\mu}m$ long cantilevers have second mode resonant frequency at 857.5 kHz and 1.14 MHz. Therefore, polycrystalline 3C-SiC micro resonators are suitable for RF MEMS devices and bio/chemical sensor applications.

  • PDF