• Title/Summary/Keyword: Laser system

Search Result 3,643, Processing Time 0.026 seconds

Satisfaction with the Effect of Local Dynamical Micro-massage Therapy on the Pain and Discomfort after Breast Reconstruction Surgery

  • Ahn, Kwang Hyeon;Lee, Sun Jae;Park, Eun Soo;Park, Yu Gil
    • Medical Lasers
    • /
    • v.9 no.1
    • /
    • pp.39-43
    • /
    • 2020
  • Background and Objectives Breast reconstruction has the advantage of reducing the loss of the body image of patients after mastectomy surgery, and also improving the quality of the social and sexual life of breast cancer patients. However, in surprising and unfortunate number of patients, acute postoperative pain persists beyond the normal course of postsurgical recovery. We set out to investigate the effect of local dynamical micro-massage (LDM) treatment for achieving pain relief and reducing other postoperative complications. Materials and Methods We performed a retrospective analysis on 58 patients who underwent LDM treatment for postoperative pain management at Soonchunhyang University Bucheon Hospital between February 2017 and June 2019. Those patients who complained of persistent postoperative pain, which was uncontrollable with medication, were treated with LDM. The degree of pain and discomfort with contracture were recorded using numerical rating scale (NRS) scoring system with numbers from 0 to 10 ('none' to 'worst'). Results The median NRS score of pain was reduced by 62.3% from the start to the end of LDM treatment (p<0.001). Further, the NRS score of discomfort with contracture was reduced 66.0% (p<0.001). There was no complication related to the LDM treatment. Conclusion Dual-frequency ultrasound LDM can be an effective therapeutic option for persisting pain after breast reconstruction surgery. It was also effective in improvement of discomfort with contracture and erythema of the surgical wound.

A Study on Improvement of Submarine Attack Periscope Operation Performance using Installing Protector on Sail (잠수함 공격잠망경 함교 보호구조물 설치를 통한 장비 운용성능 향상에 관한 연구)

  • Choi, Woo-Seok;Chang, Ho-Seong;Lee, Young-Suk;Kim, Sang-Il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.5
    • /
    • pp.199-206
    • /
    • 2021
  • This paper describes the feasibility and reliability verification of installing a protective structure to protect attack periscopes. The attack periscope is the critical equipment of a submarine to enable the user to monitor surface and air activity, collect navigational data, and detect and identify targets. The attack periscope provides target information acquired through TV, IR camera, and laser range finder to the combat system. In the product improvement program, the upper part of the masts was exposed to the outside of the sail because the existing attack periscope was replaced with a new one. On the other hand, the head sensor can be damaged by floating objects, such as fishing nets, during sea navigation. Therefore, the installation of a protective structure for an attack periscope improved the equipment operation performance. The feasibility and reliability of the installation of the protective structure were verified by examining the influence of URN.

Deletion of adipose triglyceride lipase abolishes blood flow increase after β3-adrenergic stimulation in visceral adipose tissue of mice

  • Lee, Hye-Jin;Jin, Bo-Yeong;Park, Mi-Rae;Seo, Kwan Sik;Jeong, Yong Taek;Choi, Sang-Hyun;Kim, Dong-Hoon
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.25 no.4
    • /
    • pp.355-363
    • /
    • 2021
  • Dynamic changes in adipose tissue blood flow (ATBF) with nutritional status play a role in the regulation of metabolic and endocrine functions. Activation of the sympathetic nervous system via β-adrenergic receptors (β-AR) contributes to the control of postprandial enhancement of ATBF. Herein, we sought to identify the role of each β-AR subtype in the regulation of ATBF in mice. We monitored the changes in visceral epididymal ATBF (VAT BF), induced by local infusion of dobutamine, salbutamol, and CL316,243 (a selective β1-, β2-, and β3-AR agonist, respectively) into VAT of lean CD-1 mice and global adipose triglyceride lipase (ATGL) knockout (KO) mice, using laser Doppler flowmetry. Administration of CL316,243, known to promote lipolysis in adipocytes, significantly increased VAT BF of CD-1 mice to a greater extent compared to that of the vehicle, whereas administration of dobutamine or salbutamol did not produce significant differences in VAT BF. The increase in VAT BF induced by β3-AR stimulation disappeared in ATGL KO mice as opposed to their wild-type (WT) littermates, implying a role of ATGL-mediated lipolysis in the regulation of VAT BF. Different vascular reactivities occurred despite no significant differences in vessel density and adiposity between the groups. Additionally, the expression levels of the angiogenesis-related genes were significantly higher in VAT of ATGL KO mice than in that of WT, implicating an association of ATBF responsiveness with angiogenic activity in VAT. Our findings suggest a potential role of β3-AR signaling in the regulation of VAT BF via ATGL-mediated lipolysis in mice.

Study of the Variation of Optical Amplification Characteristics with Incident Beam Size and Temperature of a Cesium-vapor-based Optical Amplifier (세슘 원자 증기 기반 광 증폭기의 온도와 빔 크기에 따른 광 증폭 특성 연구)

  • Ryu, Siheon;Jeong, Yujae;Yeom, Dong-Il
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.6
    • /
    • pp.306-313
    • /
    • 2021
  • We study the amplification properties of an optical amplifier based on a cesium-vapor cell. An optical amplification system including cesium vapor mixed with a buffer gas is built, and its amplification feature is investigated as a function of the size of the incident beam and the temperature of the cesium-vapor cell. We observe that the optical amplification properties, such as amplification factor and extraction efficiency, change significantly depending on the temperature and beam diameter of the pump and seed light. A maximum extraction efficiency of 56% is obtained when the temperature of the cesium cell is 90 ℃, with a 200-㎛ diameter of the pump (500 mW) and seed light (10 mW). The numerical simulation of the amplification properties agrees reasonably with the results obtained from the experiment.

Measurement of Bangudae Rock Joint Using Non-adhesive, Non-contact Inclinometer Slope Laser Measuring System (비부착, 비접촉 방식의 계측기를 이용한 반구대암각화 암반 절리면의 계측)

  • Kim, Jae Hyun;Lee, Sang Ok;Chung, Kwang Yong;Han, Min Su
    • Journal of Conservation Science
    • /
    • v.37 no.6
    • /
    • pp.617-625
    • /
    • 2021
  • Daegokcheon Stream in Daegok-ri, Ulju-gun, is an area with a developed valley and bedrock from Gajisan Provincial Park to the confluence of the Taehwa River across the Yangsan Fault. To measure the rock of Bangudae petroglyphs, the mineralogical weathering, joints, and scours or cavities at the bottom were confirmed. The measurement was carried out for a short period of time on the joint of the bedrock on which the Bangudae petroglyphs were engraved. Compared to the measured value obtained using existing optical fiber (Ch4 150 ㎛), a displacement value of 300 ㎛ was obtained using the non-attached, non-contact type of measuring instrument. In the future, it is inferred that this instrument could be used for various cultural properties if the HSV-value suitable for illuminance and various measurement experiences are stored.

Effects of hairline treatment on surface blackening and thermal diffusion of Zn-Al-Mg alloy-coated steel sheet (Zn-Al-Mg 합금도금강판의 헤어라인 처리가 표면흑색화 및 열확산도에 미치는 영향)

  • Jin Sung Park;Duck Bin Yun;Sang Heon Kim;Tae Yeob Kim;Sung Jin Kim
    • Journal of the Korean institute of surface engineering
    • /
    • v.56 no.1
    • /
    • pp.69-76
    • /
    • 2023
  • The effects of hairline treatment on surface blackening and thermal diffusion behaviors of Zn-Al-Mg alloy coated steel sheet were evaluated by the three-dimensional surface profiler and laser-flash technique. The metallographic observation of coating damages by hairline treatments showed that several cracks were initiated and propagated along the interface between primary Zn/eutectic phases. As the hairline processing became more severe, the crack occurrence frequency in eutectic phase of coating layer and the surface roughness increased, which had a proportional relationship with the level of blackening on the coating surface. In addition, the higher interfacial areas of the blackened coating surface, caused by the hairline process, led to an increase in thermal diffusivity and conductivity of the coated steel sheet. On the other hand, when the coating damage by hairline treatment was excessive and the steel substrate was exposed, there was little difference between the thermal diffusivity/conductivity of the untreated sample though the blackening degree was higher than that of untreated sample. This work suggests that the increase in the surface areas of the coating layer without exposure to steel substrate through hairline treatment can be one of the effective technical strategies for the development of Zn-Al-Mg alloy coated steel sheets with higher blackening level and thermal diffusivity.

Effects of Magnetic Therapy to Improve on Pain Threshold, Blood Flow, and Balance in Patient with Knee Osteoarthritis (자기장 치료법이 무릎 뼈관절염 환자의 통증 역치, 혈류량 및 균형능력에 미치는 영향)

  • Kyong-Hun Kim;Dong-Hoon Kim
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.11 no.3
    • /
    • pp.127-135
    • /
    • 2023
  • Purpose : This study was performed to evaluate the effects of magnetic therapy (MT) on pain threshold, blood flow, and balance in patients with knee osteoarthritis. Methods : A single-blind, randomized controlled trial (RCT) was conducted with 30 patient with knee osteoarthritis. They were randomly allocated 2 groups; magnetic therapy group (MTG; n=15) and placebo magnetic therapy group (PG; n=15). The MTG group received 30 minutes magnetic therapy and 20 minute conservative physical therapy (Hotpack, ICT), magnetic therapy was conducted in magnetic therapy device (OM-100, NUGA, Korea). In the placebo magnetic group received 30 minutes placebo magnetic therapy and 20 minute conservative physical therapy. Each group performed 50 minutes a day 3 times a week for 8 weeks. The primary outcome pressure pain threshold test, blood flow, balance ability were measured by a pressure threshold meter (Commander algometer, JTECH medical, USA), laser dofler image (Moor LDI2-IR, Moor instruments, USA), balance measurement system (BioRescue, Marseille, France). The measurement were performed before and after the 8 weeks intervention period. Results : Both groups demonstrated significant improvement of outcome in pain threshold, blood flow, and balance ability during intervention period. magnetic therapy group revealed significant differences in pain threshold, blood flow, and balance as compared to the placebo magnetic therapy group groups (p<.05). Our results showed that magnetic therapy was more effective than placebo therapy on pain threshold, blood flow, and balance in patients with knee osteoarthritis. Conclusion : Our findings indicate that magnetic therapy can improve pain threshold, blood flow, and Balance, highlight the benefits of magnetic therapy. This study will be able to be used as an intervention data for recovering pain threshold, blood flow, and balance in patients with knee osteoarthritis.

Profiling of differentially expressed proteins between fresh and frozen-thawed Duroc boar semen using ProteinChip CM10

  • Yong-Min Kim;Sung-Woo Park;Mi-Jin Lee;Da-Yeon Jeon;Su-Jin Sa;Yong-Dae Jeong;Ha-Seung Seong;Jung-Woo Choi;Shinichi, Hochi;Eun-Seok Cho;Hak-Jae Chung
    • Journal of Animal Science and Technology
    • /
    • v.65 no.2
    • /
    • pp.401-411
    • /
    • 2023
  • Many studies have been conducted to improve technology for semen cryopreservation in pigs. However, computer-assisted analysis of sperm motility and morphology is insufficient to predict the molecular function of frozen-thawed semen. More accurate expression patterns of boar sperm proteins may be derived using the isobaric tags for relative and absolute quantification (iTRAQ) technique. In this study, the iTRAQ-labeling system was coupled with liquid chromatography tandem-mass spectrometry (LC-MS/MS) analysis to identify differentially expressed CM10-fractionated proteins between fresh and frozen-thawed boar semen. A total of 76 protein types were identified to be differentially expressed, among which 9 and 67 proteins showed higher and lower expression in frozen-thawed than in fresh sperm samples, respectively. The classified functions of these proteins included oxidative phosphorylation, mitochondrial inner membrane and matrix, and pyruvate metabolic processes, which are involved in adenosine triphosphate (ATP) synthesis; and sperm flagellum and motile cilium, which are involved in sperm tail structure. These results suggest a possible network of biomarkers associated with survival after the cryopreservation of Duroc boar semen.

Admittance Model-Based Nanodynamic Control of Diamond Turning Machine (어드미턴스 모델을 이용한 다이아몬드 터닝머시인의 초정밀진동제어)

  • Jeong, Sanghwa;Kim, Sangsuk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.10
    • /
    • pp.154-160
    • /
    • 1996
  • The control of diamond turning is usually achieved through a laser-interferometer feedback of slide position. The limitation of this control scheme is that the feedback signal does not account for additional dynamics of the tool post and the material removal process. If the tool post is rigid and the material removal process is relatively static, then such a non-collocated position feedback control scheme may surfice. However, as the accuracy requirement gets tighter and desired surface cnotours become more complex, the need for a direct tool-tip sensing becomes inevitable. The physical constraints of the machining process prohibit any reasonable implementation of a tool-tip motion measurement. It is proposed that the measured force normal to the face of the workpiece can be filtered through an appropriate admittance transfer function to result in the estimated dapth of cut. This can be compared to the desired depth of cut to generate the adjustment control action in additn to position feedback control. In this work, the design methodology on the admittance model-based control with a conventional controller is presented. The recursive least-squares algorithm with forgetting factor is proposed to identify the parameters and update the cutting process in real time. The normal cutting forces are measured to identify the cutting dynamics in the real diamond turning process using the precision dynamoneter. Based on the parameter estimation of cutting dynamics and the admitance model-based nanodynamic control scheme, simulation results are shown.

  • PDF

Spectral Analyses of Ultrashort Pulses Using Recursive Partial-Response Signaling System Model (순환적 PRS 시스템 모델을 이용한 극초단펄스의 스펙트럼 분석)

  • Oh, Yong S.
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.1 no.1
    • /
    • pp.85-93
    • /
    • 1997
  • In this paper, a novel method for obtaining spectra of short pulses is proposed. This method will be well-applied to perform spectral analyses of ultrashort laser pulses which are known to be difficult to evaluate their exact forms in frequency domain because of their narrow-width characteristics in time domain. It must be noted that the method can be represented by a recursive formula derived from the PRS(partial-response signaling) model, and thus more easily available for numerical solutions than the conventional methods such as consecutive differentiations and convolutions. The pulses whose fundamental frames can be exactly determined or approximately represented by truncated Fourier series have well-behaving conditions for applications of this new method. Moreover, the transversal 9-type PRS model can offer various approximations for spectral analyses of ultrashort pulses currently used in transmission systems.

  • PDF