• 제목/요약/키워드: Laser induced fluorescence

검색결과 249건 처리시간 0.022초

기체구 분사 모델을 이용한 CNG 직접분사식 인젝터 분사 수치해석 기법 (Modeling of CNG Direct Injection using Gaseous Sphere Injection Model)

  • 최민기;박성욱
    • 한국분무공학회지
    • /
    • 제21권1호
    • /
    • pp.47-52
    • /
    • 2016
  • This paper describes the modeling of CNG direct injection using gaseous sphere injection model. Simulation of CNG direct injection does not need break up and evaporation model compared to that of liquid fuel injection. And very fine mesh is needed near the injector nozzle to resolve the inflow boundary. Therefore it takes long computation time for gaseous fuel injection simulation. However, simulation of CNG direct injection could be performed with the coarse mesh using gaseous sphere injection model. This model was integrated in KIVA-3V code and RNG $k-{\varepsilon}$ turbulence model needs to be modified because this model tends to over-predict gas jet diffusion. Furthermore, we preformed experiments of gaseous fuel injection using PLIF (planar laser induced fluorescence)method. Gaseous fuel injection model was validated against experiment data. The simulation results agreed well with the experiment results. Therefore gaseous sphere injection model has the reliability about gaseous fuel direct injection. And this model was predicted well a general tendency of gaseous fuel injection.

Quantitative observation of co-current stratified two-phase flow in a horizontal rectangular channel

  • Lee, Seungtae;Euh, Dong-Jin;Kim, Seok;Song, Chul-Hwa
    • Nuclear Engineering and Technology
    • /
    • 제47권3호
    • /
    • pp.267-283
    • /
    • 2015
  • The main objective of this study is to investigate experimentally the two-phase flow characteristics in terms of the direct contact condensation of a steam-water stratified flow in a horizontal rectangular channel. Experiments were performed for both air-water and steam-water flows with a cocurrent flow configuration. This work presents the local temperature and velocity distributions in a water layer as well as the interfacial characteristics of both condensing and noncondensing fluid flows. The gas superficial velocity varied from 1.2 m/s to 2.0 m/s for air and from 1.2 m/s to 2.8 m/s for steam under a fixed inlet water superficial velocity of 0.025 m/s. Some advanced measurement methods have been applied to measure the local characteristics of the water layer thickness, temperature, and velocity fields in a horizontal stratified flow. The instantaneous velocity and temperature fields inside the water layer were measured using laser-induced fluorescence and particle image velocimetry, respectively. In addition, the water layer thickness was measured through an ultrasonic method.

PLIF 기법을 이용한 액체로켓용 충돌분사 인젝터의 분무분포 특성 해석 (Analysis of the Spray Distribution Characterization of Impinging Jet Injectors for Liquid Rockets Using PLIF Technique)

  • 정기훈;윤영빈;황상순
    • 한국추진공학회지
    • /
    • 제4권1호
    • /
    • pp.36-45
    • /
    • 2000
  • 지금까지의 충돌분무에 대한 연구는 제트의 충돌시 형성되는 액막의 분열 과정을 이해하고 이를 모델링하는데 초점을 두어왔기 때문에 실질적으로 연소 효율에 가장 큰 영향을 미치는 연료의 공간분포 특성에 대한 연구가 부족하였다. 따라서 본 연구에서는 like-doublet 충돌분사 노즐을 사용하여 연료 유량 플럭스의 단면분포 특성을 연구하였다. PDPA(Phase Doppler Particle Analyzer)를 통해 액적의 크기를 측정한 기존의 방법은 연료의 평면적인 분포특성을 이해하는데 상당히 제한적이었기 때문에 평면 레이저 유도형광기법(PLE : Planar Laser Induced Fluorescence)을 이용하여 분무의 단면 분포를 측정하였고, 직접사진을 통하여 액적의 크기도 측정하여 PLIF의 결과와 비교하였다.

  • PDF

An Experimental Study on Angled Injection and Droplet Size Characteristics of Liquid Jets in Subsonic Crossflow

  • Kim, Min-Ki;Song, Jin-Kwan;Hwang, Jeong-Jae;Yoon, Young-Bin
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.486-491
    • /
    • 2008
  • The spray characteristics and drop size measurements have been experimentally studied in liquid jets injected into subsonic crossflow. With water as fuel injection velocity, injection angle and atomizer internal flows were varied to provide of jet operation conditions. The injector internal flow was classified as three modes such as a non-cavitation flow, cavitation, and hydraulic flip flows. Pulsed Shadowgraph Photography measurement was used to determine the spatial distribution of the spray droplet diameter in a subsonic crossflow of air. And this study also obtains the SMD(Sauter Mean Diameters) distribution by using PLLIF(Planar Liquid Laser Induced Fluorescence) technique. The objectives of this research are getting a droplet distribution and drop size measurement of each condition and compare with the other flows effect. As the result, This research have been showed the droplet size were spatially dependent on air-stream velocity, fuel injection velocity, injection angle effects and normalized distance from the injector exit length.(x/d, y/d)There are also different droplet size characteristics between cavitation, hydraulic flip and the non-cavitation flows.

  • PDF

레이저 유도 선해리 형광법(LIPE)을 이용한 화염내 OH 및 $O_{2}$ 분자의 2차원 농도 분포 측정 (Planar measurements of OH and $O_{2}$ number density in premixed $C_{3}$H$_{8}$O$_{2}$ flame using laser induced pre-dissociative fluorescence)

  • 진성호;남기중;김회산;장래각;박승환;김웅;박경석;심경훈;김경수
    • 대한기계학회논문집B
    • /
    • 제20권12호
    • /
    • pp.4044-4052
    • /
    • 1996
  • Planar images of OH and $O_{2}$ with tunable KrF excimer laser which has a) 0.5 $cm^{-1}$ / linewidth, b) 0.5 nm tuning range, c) 150 mJ pulse energy, and d) 20 ns pulse width are obtained to determine spatial distributions of OH and $O_{2}$ in premixed $C_{3}$H$_{8}$ /O$_{2}$ flame. The technique is based on planar laser induced pre-dissociative fluorescence(PLIPF) in which collisional quenching is almost avoided because of the fast pre-dissociation. Dispersed LIPF spectra of OH and $O_{2}$ are also measured in a flame in order to confirm the excitation of single vibronic state of OH and $O_{2}$, OH and $O_{2}$ are excited on the P$_{2}$(8) line of the $A^{2}$.SIGMA.$^{+}$(v'= 3)-X$^{2}$.PI.(v'||'||'&'||'||'quot;= 0) band and R(17) line of the Schumann-Runge band B$^{3}$.SIGMA.$_{u}$ $^{[-10]}$ (v'= 0)- X$^{3}$.SIGMA.$_{g}$ $^{[-10]}$ (v'||'||'&'||'||'quot;= 6), respectively. Dispersed OH and $O_{2}$ spectra show an excellent agreement with simulated spectrum and previous works done by other group respectively. It is confirmed that OH widely distributed around flame front area than $O_{2}$.

Digital Imaging Fiber-Optic Trans-Illumination과 Laser Fluorescence를 이용한 법랑질 우식증의 조기 진단에 관한 비교 연구 (COMPARATIVE STUDY ON THE EARLY DETECTION OF ENAMEL LESIONS USING DIFOTI AND LASER FLUORESCENCE)

  • 맹명호;김승오;김종수
    • 대한소아치과학회지
    • /
    • 제33권2호
    • /
    • pp.207-220
    • /
    • 2006
  • 새로 개발된 조기 진단 장비들로는 laser fluorescence device(LFD), 초음파 진단 시스템, confocal laser scanning microscopy(CLSM), quantitative light-induced fluorescence(QLF) 시스템 그리고 digital imaging fiber-optic trans-illumination(DIFOTI) 시스템 등이 있다. 본 연구는 임상에서 사용되고 있는 DIFOTI시스템과 LFD를 이용하여 유치 교환 시기에 있는 환아 21명, 25개의 유치를 대상으로 각 치아당 $1{\sim}3$점을 선정하여 구강내에서 초기 우식법랑질에 대한 DIFOTI 이미지 촬영 결과와 LFD 계측값을 3회 측정하고 그 평균을 대표값으로 한 결과를 CLSM과 비교하여 진단 능력을 평가하였다. 실험실 연구에서는 인공우식 용액을 이용하여 수거된 40개의 유치를 협설면에 $2{\times}3mm$ 크기의 창을 형성하고 4, 8, 12, 16일간 탈회시키면서 그 변화를 DIFOTI 시스템과 LFD를 이용하여 측정하고 이를 CLSM과 비교 분석하여 다음과 같은 결론을 얻었다. 1. 구강내에서 촬영된 DIFOTI의 민감도는 88.2%이었고, 특이도는 76.9%이었다. 2. 구강내에서 측정된 LDD의 민감도는 76.5%이었고, 특이도는 69.2%이었다. 3. 실험실 연구에서 유치 법랑질의 탈회 기간에 따른 DIFOTI 광투과율의 회귀 분석한 결과, 탈회 시간에 따라 광투과율은 감소하였다(r=-0.96, p<0.05). 4. 실험실에서 탈회 기간에 따른 LFD의 측정값의 회귀 분석 결과 통계적 유의성을 보이지 않았다(p>0.05). 5. DIFOTI 이미지의 광투과율과 CLMS의 병소 깊이에 대한 상관 계수는 -0.688이었으나(p<0.05), LFD의 측정값은 유의성을 보이지 않았다.

  • PDF

Like-Doublet 인젝터의 분무 질량분포 측정을 위한 PLLIF기법의 신뢰성 평가 (Assessment of PLLIF Measurement for Spray Mass Distribution of Like-Doublet Injector)

  • 정기훈;고현석;윤영빈
    • 한국가시화정보학회지
    • /
    • 제1권1호
    • /
    • pp.98-106
    • /
    • 2003
  • A PLLIF (Planar Liquid Laser Induced Fluorescence) technique has been known to be a useful tool for the measurement of the spray patterns for various spray injectors because it can obtain two-dimensional images with high spatial resolutions without any intrusion on the spray field. In case of dense spray, however, the secondary emission as well as the extinction of an incident laser beam or a fluorescence signal can cause errors in quantifying a mass distribution. Unfortunately, a like-doublet injector which has a dense spray zone at the center may not be a good example or the application of the PLLIF technique. Therefore, we took PLLIF data for the like-doublet injector with a 12 bit color CCD camera by varying laser power, and then assessed their accuracy by comparing with the data obtained with a mechanical patternator and a PDPA (Phase Doppler Particle Analyzer). The experimental results showed that the gray level of fluorescence signal increases nonlinearly due to a secondary emission at the dense spray zone but this nonlinearity can be avoided by reducing the incident laser beam power. In addition, the mass flux distribution of the spray could be obtained by using the mass concentration data from PLLIF technique and the velocity profiles of liquid drops, and this distribution showed good agreement with that of mechanical pattemator. Therefore, it is possible that the PLLIF technique can be successfully applied to finding the mass distributions of like-doublet injectors.

  • PDF

고정밀 전하결합장치를 이용한 레이저유도 형광분광기의 설계 및 제작 (The design and Manufacture of Laser Induced Fluorescence Spectroscope Using the High Resolution Charge Coupled Device)

  • 김기준;이후설
    • 한국산학기술학회논문지
    • /
    • 제6권2호
    • /
    • pp.129-133
    • /
    • 2005
  • 분자 에너지 준위, 분자구조, 흡수, 방출, 상호분자 반응, 또는 약하게 결합된 분자에너지, 광화학, 형광, PDT치료에 관한 연구를 수행하는데 분광계에서 CCD는 매우 중요하다. CCD는 현대 물리화학 분야에서 레이저 분광학에 의한 의공학 및 분자 구조의 연구에 필수적이다. 그리하여 CCD를 이용한 전자기 분광계의 설계 및 제작을 연구하였으며 프린트된 전자회로 및 포르폴린을 분석하였다. 예전에 CCD는 방송장비에만 사용한다고 생각했지만 현대에는 산업발전에 의한 응용으로 로봇공학, 기기분석 및 관측에 대한 산업적 요구에 더욱 많이 활용된다.

  • PDF

Noncontact strain sensing in cement-based material using laser-induced fluorescence from nanotube-based skin

  • Meng, Wei;Bachilo, Sergei M.;Parol, Jafarali;Weisman, R. Bruce;Nagarajaiah, Satish
    • Structural Monitoring and Maintenance
    • /
    • 제9권3호
    • /
    • pp.259-270
    • /
    • 2022
  • This study explores the use of the recently developed "strain-sensing smart skin" (S4) method for noncontact strain measurements on cement-based samples. S4 sensors are single-wall carbon nanotubes dilutely embedded in thin polymer films. Strains transmitted to the nanotubes cause systematic shifts in their near-infrared fluorescence spectra, which are analyzed to deduce local strain values. It is found that with cement-based materials, this method is hampered by spectral interference from structured near-infrared cement luminescence. However, application of an opaque blocking layer between the specimen surface and the nanotube sensing film enables interference-free strain measurements. Tests were performed on cement, mortar, and concrete specimens with such modified S4 coatings. When specimens were subjected to uniaxial compressive stress, the spectral peak separations varied linearly and predictably with induced strain. These results demonstrate that S4 is a promising emerging technology for measuring strains down to ca. 30 𝜇𝜀 in concrete structures.

레이저 유도형광분광기에서 고정밀 전하장치를 이용한 304 스테인레스 스틸의 코팅과 특성 (The Characterization and Coatings on 304 Stainless Steel by Laser Induced Fluorescence Spectroscopy using the High Resolution Charge Coupled Device)

  • 김기준;이주엽;성완모
    • 한국응용과학기술학회지
    • /
    • 제33권2호
    • /
    • pp.385-390
    • /
    • 2016
  • 연구에서 나노 알루미나와 마그네지아의 첨가에 의한 304 스테인레스 스틸에 $170^{\circ}C$ 2시간 열 경화시켰다. 레이저유도 분광학에 의한 코팅된 시료를 전하결합 장치와 SEM을 활용한 장치를 설계하여 시험 측정하였다. 이 결과 나노 알루미나와 마그네지아가 함유된 세라믹 코팅이 나노 무기화합물이 함유되지 않은 시료보다 부착성, 내스크래치성이 우수하였으며, 또한 산용액속에서 시료의 질량감소의 변화가 매우 작았다. 그리하여 본 연구는 304 스테인레스 스틸의 내부식성을 개선하기 위해 시료가 코팅되었으며, 분석공정이 설계되어 고분해능 CCD와 함께 분석되었다. 요즈음, 스테인레스 스틸의 코팅은 산업에 특이응용이 발전됨에 따라 위생학, 우주항공, 기기장치, 관측 등의 분야 등에 산업적 요구가 증가되고 있다.