• 제목/요약/키워드: Laser induced fluorescence

검색결과 248건 처리시간 0.026초

A Study on the Development of Measurement Techniques for Thermal Flows in MEMS

  • Ko Han-Seo;Yang Sang-Sik;Yoo Jai-Suk;Kim Hyun-Jung
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권3호
    • /
    • pp.387-395
    • /
    • 2006
  • A review on advanced flow visualization techniques is presented particularly for applications to micro scale heat and mass transport measurements. Challenges, development and applications of micro scale visualization techniques are discussed for the study of heating/evaporating thin films, a heated micro channel, and a thermopneumatic micro pump. The developed methods are (1) Molecular Tagging Fluorescence Velocimetry (MTFV) using 10-nm caged seeding molecules (2) Micro Particle Velocimetry (MPIV) and (3) Ratiometric Laser Induced Fluorescence (LIF) for micro-resolution thermometry. These three methods are totally non-intrusive techniques and would be useful to investigate the temperature and flow characteristics in MEMS. Each of these techniques is discussed in three-fold: (1) its operating principle and operation, (2) its application and measurement results, and (3) its future challenges.

PLIF를 이용한 ATR 연소기 축소모형의 연료분포 측정연구 (Measurement of the fuel distribution in a scaled ATR combustor using PLIF)

  • 진유인;양인영;최영환;양수석
    • 한국추진공학회지
    • /
    • 제9권4호
    • /
    • pp.55-65
    • /
    • 2005
  • 에어 터보 램제트 엔진 연소기에서 연료와 공기의 혼합성능은 연소 효율과 안정성에 중요한 요인이 된다. 에어 터보 램제트 축소모형의 연소기에서 혼합기에 따른 혼합성능을 파악하기 위하여 두개의 꽃잎형 혼합기를 제작하였고, 각각에 대하여 연료 분포를 측정하였다. 2차원 연료 분포 측정에는 평면 레이저 유도 형광 기법을 사용하였다. 획득한 아세톤 형광 이미지는 이미지 처리 기법을 사용하여 정량적 연료 분포로 나타내었다. 이러한 연료 분포 이미지를 바탕으로 연료와 공기의 혼합성능이 좋은 혼합기를 알아내었다.

LIF 공초점 현미경을 이용한 Y-채널 마이크로믹서의 혼합 효율 평가 (Mixing Efficiency Evaluation in Y-channel Micromixer Using LIF Confocal Microscope)

  • 김경목;신용수;안유민;이도형
    • 대한기계학회논문집B
    • /
    • 제31권2호
    • /
    • pp.159-166
    • /
    • 2007
  • Mixing between two or more reagents is one of important processes in biochemical microfluidics. In efficient micromixer design, it is essential to analyze flow pattern and evaluate mixing efficiency with good precision. In this work, mixing efficiency for Y-channel micromixer is measured by fluorescence intensity using LIF(Laser Induced Fluorescence) Confocal Microscope. The Y-channel micromixers are fabricated with polydimethylsiloxane(PDMS) and those are bonded to glass plate through Plasma bonding. Nile Blue A is injected into the micromixer as a fluorescence dye for measuring of fluorescence intensity by He/Ne laser. For visualization of the flow pattern, dynamic image capturing is carried out using CAM scope. For the comparison with computer simulation, modified SIMPLE algorithm for incompressible flow equation is solved for the same geometry as in the experiment. Throughout the experiments and computer simulation, accurate mixing efficiency evaluation process for a PDMS Y-channel micromixer is established.

파장 가변형 KrF 에시머 레이저를 이용한 층류 비예혼합 수소 화염에서의 2차원적 온도 및 농도 계측 (Planar Imaging of Temperature and Concentration of a Laminar Nonpremixed $H_2$/$N_2$flame Using a Tunable KrF Excimer Laser)

  • 김군홍;진성호;김용모;박경석;김세원;김경수
    • 대한기계학회논문집B
    • /
    • 제24권12호
    • /
    • pp.1580-1587
    • /
    • 2000
  • Rayleigh scattering and laser induced predissociative fluorescence are employed for capturing two-dimensional images of temperature and species concentration in a laminar nonpremixed flame of a diluted hydrogen jet. Rayleigh scattering cross-sections are experimentally obtained ar 248nm. Dispersed LIPF spectra of OH and O$_2$ are also measured in a flame in order to confirm the excitation of single vibronic state of OH and O$_2$ .OH and O$_2$ are excited on the P$_1$(8) line of the A $^2\Sigma ^+(v^`=3) - X^2\pi (V^"=0)$ band and R(17) line of the Schumann-Runge band B $^3\Sigma _u^-(v^`=0) - X ^3\Sigma _g^-(v^"=6)$, respectively. Fluorescence spectra of OH and Hot O$_2$ are captured and two-dimensional images of the hydrogen flame field are successfully visualized.

혼탁 매질에서 광산란에 의한 광학적 파라미터들의 측정에 관한 연구 (Studies on the Measurements of Optical Parameters in Turbid Material by Light Scattering)

  • 김기준;성기천
    • 한국응용과학기술학회지
    • /
    • 제12권2호
    • /
    • pp.151-156
    • /
    • 1995
  • The influences of fluorophor, scatterer, absorber in turbid material by light scattering were interpreted for the scattered fluorescence intensity and wavelength, it has been studied the molecular properties by laser induced fluorescence spectroscopy. It has been found that the effects of optical properties in scattering media by the optical parameters(${\mu}_{s}$, ${\mu}_{a}$, ${\mu}_{t}$). The value of scattering coefficient ${\mu}_{s}$ is large by means of the increasing particles of scatterer, it has been found that the slope decays exponentially as a function of distance from laser source to detector. It may also aid in designing the best model for oil chemistry, laser medicine and application of medical engineering.

Laser Diagnostic in a Plasma Display Panel Discharge Cell

  • Choi, Young-Wook
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2000년도 제1회 학술대회 논문집
    • /
    • pp.21-22
    • /
    • 2000
  • Laser diagnostic method in a plasma display discharge cell was introduced. The information of electric field, potential and electron temperature et al. in the surface of plasma display panel can be measured using laser induced fluorescence spectroscopy. However, because of the very small discharge dimension of ${\sim}$ 100 ${\mu}m$, the measurement attempt has almost not been performed. In this paper, the direct measurement possibility of the parameters and the recent work of electric field measurement are demonstrated in the plasma display panel.

  • PDF

집적화된 Lab-On-a Chip을 위한 광센서의 제작 및 특성 평가 (Development of Photo-sensor for Integrated Lab-On-a-Chip)

  • 김주환;신경식;김용국;김태송;김상식;주병권
    • 한국전기전자재료학회논문지
    • /
    • 제17권4호
    • /
    • pp.404-409
    • /
    • 2004
  • We fabricated photo-sensor for fluorescence detection in LOC. LOC is high throughput screening system. Our LOC screens biochemical reaction of protein using the immunoassay, and converts biochemical reaction into electrical signal using LIF(Laser Induced Fluorescence) detection method. Protein is labeled with rhodamine intercalating dye and finger PIN photodiode is used as photo-sensor We measured fluorescence emission of rhodamine dye and analyzed tendency of fluorescence detection, according to photo-sensor size, light intensity, and rhodamine concentration. Detection current was almost linearly proportional to two parameters, intensity and concentration, and was inversely proportional to photo-sensor size. Integrated LOC consists of optical-filter deposited photo-sensor and PDMS microchannel detected 50 (pg/${mu}ell$) rhodamine. For integrated LOC including light source, we used green LED as the light source and measured emitted fluorescence.

초기 우식 병소에서 광원에 따른 형광효과 비교 (A COMPARISON OF FLUORESCENCE EFFECT OF VARIOUS LIGHT SOURCES IN EARLY ENAMEL CARIES)

  • 전정훈;이난영;이창섭;이상호
    • 대한소아치과학회지
    • /
    • 제32권4호
    • /
    • pp.611-619
    • /
    • 2005
  • 본 연구의 목적은 초기 우식 병소에서 광원에 따른 형광효과를 비교하는 것으로 정량 분석형 laser/light 형광법(Quantitative laser/light-induced fluorescence, QLF)을 이용하여 아르곤 레이저광, 할로겐광, 발광다이오드광(LED), 플라즈마광의 형광효과를 비교하였다. 발거된 60개의 치아를 선정한 후, 인공우식용액에 노출되지 않을 부분에 nail varnish를 도포하였고 치아는 24, 48, 72시간 동안 인공우식용액에 보관되었다. 건조 후 QLF영상으로 초기 우식 부위의 광밀도 차이에 의한 탈회정도가 기록되었다. 또한 조영제를 이용하여 동일한 방법으로 실험하였고 다음과 같은 결과를 얻었다 염료를 이용하여 같은 방법으로 실험하여 또 다른 결과를 얻었다. 1. 각 군의 평균 광밀도를 볼 때, 플라즈마광이 세 군 모두에서 다른 광원들 보다 높았다(p<0.05). 2. 세 군 사이에서 평균 광밀도를 비교해 볼 때, 플라즈마광과 할로겐광이 차이를 보였다(p<0.05). 3. 조영제를 사용하였을 경우 평균 광밀도를 비교해 볼 때, 플라즈마광이 세 군 모두에서 다른 광원들보다 높았고 (p<0.05), 발광다이오드광(LED)와 아르곤 레이저광을 제외한 모든 광원이 차이를 보였다(p<0.05). 4. 조영제를 사용하지 않은 경우와 사용한 경우 평균 광밀도를 비교해 볼 때, 사용한 경우에 모든 광원의 평균 광밀도 차이가 컸다.

  • PDF

Kinetic Study on the Low-lying Excited States of Ga Atoms in Ar

  • Kuntack Lee;Ju Seon Goo;Ja Kang Ku
    • Bulletin of the Korean Chemical Society
    • /
    • 제15권8호
    • /
    • pp.663-669
    • /
    • 1994
  • Decay kinetics of Ga(5s), Ga(5p) and Ga(4d) atoms in Ar were studied by laser induced fluorescence technique. Theground state gallium atoms in the gas phase were generated by pulsed dc discharge of trimethyl gallium and argon mixtures. Both pulsed discharge and YAG-DYE laser system were controlled by a dual channel pulse generator and the delay time between the end of discharge and laser pulses was set 3.0-6.0 ms. The Ga(5s) and Ga(4d) atoms were generated by single photon excitation from the ground state Ga atoms and radiative lifetimes as well as the total quenching rate constants in Ar were obtained from the pressure dependence of the fluorescence decay rates. The Ga(5p) atoms were populated by a two-photon excitation method and the cascade fluorescence from Ga(5s) atoms were analyzed to extract quenching rate constant of Ga(5p) atoms by Ar in addition to radiative lifetimes of Ga(5p) state. The magnitudes of the quenching rate constants by Ar for the low-lying excited states of Ga atoms are 1.6-3$ {\times}10^{-11}cm^3$ molecul$e^{-1}s^{-1}$, which are much larger than those for alkali, alkaline earth and Group 12 metals. Based on the measured rate constants, kinetic simulations were done to assign state-to-state rate constants.