• 제목/요약/키워드: Laser diode

검색결과 1,017건 처리시간 0.031초

레이저 다이오드를 이용한 이진 신호누적 방식의 거리측정기 기술 (A DLRF(Diode Laser Range Finder) Using the Cumulative Binary Detection Algorithm)

  • 양동원
    • 한국군사과학기술학회지
    • /
    • 제10권4호
    • /
    • pp.152-159
    • /
    • 2007
  • In this paper, a new design technique on the LRF which is useful for low power laser and a CBDA(Cummulative Binary Detection Algorithm) is proposed. The LD(Laser Diode) and Si-APD(Silicon Avalanche Photo Diode) are used for saving a power. In order to prove the detection range, the Si-APD binary data are accumulated before the range computation and the range finding algorithm. A prototype of the proposed DLRF(Diode Laser Range Finder) system was made and tested. An experimental result shows that the DLRF system have the same detection range using a less power(almost 1/32) than an usual military LRF. The proposed DLRF can be applied to the Unmanned Vehicles, Robot and Future Combat System of a tiny size and a low power LRF.

연소배기 가스의 계측을 위한 다이오드 레이저 센서 (Diode-Laser Absorption Sensors for measurement of combustion Gas)

  • 신명철;김세원;김동혁
    • 한국연소학회지
    • /
    • 제11권3호
    • /
    • pp.26-35
    • /
    • 2006
  • This work forcus on the development of gas sensor that measure the concentrations of exhaust gas using diode laser, Each diode laser for exhaust gas measurement is set to work at near-IR using both DA and WMS methods. Also use of fiber-coupled optical elements makes such a sensor rugged and easy to align. The results showed that gas concentrations of $O_2$, CO, $CO_2$, NO are accurately measured within ${\pm}2%$ error. The application of WMS method increased the beam intensity 2-3 times higher than DA method. It were experimentally compared WMS (Wavelength Modulation Spectroscopy) with DA (Direct Absorption) for the accuracy.

  • PDF

다이오드 레이저를 이용한 배기가스 $O_2$ 농도 및 온도 동시 측정에 관한 실험적 연구 (The Experimental Study on Simultaneous Measurements of $O_2$ Concentration and Temperature of Flue Gas Using a Single Diode Laser)

  • 김세원;신명철;이창엽;윤성운;김영일
    • 한국연소학회지
    • /
    • 제17권1호
    • /
    • pp.12-21
    • /
    • 2012
  • Simultaneous measurements of oxygen concentration and temperature using diode laser in the combustion environment are successfully accomplished. A single DFB type diode laser of 760 nm line centre frequency is used and the scanned-wavelength direct absorption spectroscopy method and wavelength modulation spectroscopy method are applied to measure absorption signals below 793 K temperature region. The experimental results show that oxygen concentration are measured within 1% accuracy and temperature are measured within 5% accuracy. This new method of simultaneous measurements of concentration and temperature with a single diode laser shows a great promise.

비젼 피드백 제어를 이용한 광통신 Laser Diode Test Device 개발 (Development of Laser Diode Test Device using Feedback Control with Machine Vision)

  • 유철우;송문상;김재희;박상민;유범상
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1663-1667
    • /
    • 2003
  • This thesis is on tile development of LD(Laser Diode) chip tester and the control system based on graphical programming language(LabVIEW) to control the equipment. The LD chip tester is used to test the optic power and the optic spectrum of the LD Chip. The emitter size of LD chip and the diameter of the receiver(optic fiber) are very small. Therefore, in order to test each chip precisely, this tester needs high accuracy. However each motion part of the tester could not accomplish hish accuracy due to the limit of the mechanical performance. Hence. an image processing with machine vision was carried out in order to compensate for the error. and also a load test was carried out so as to reduce tile impact of load on chip while the probing motion device is working. The obtained results were within ${\pm}$5$\mu\textrm{m}$ error.

  • PDF

Bypass Heat Sink Analysis for a Laser Diode Bar with a Top Canopy

  • Ji, Byeong-Gwan;Lee, Seung-Gol;Park, Se-Geun;O, Beom-Hoan
    • Current Optics and Photonics
    • /
    • 제1권2호
    • /
    • pp.113-117
    • /
    • 2017
  • With the increasing use of high-power laser diode bars (LDBs) and stacked LDBs, the issue of thermal control has become critical, as temperature is related to device efficiency and lifetime, as well as to beam quality. To improve the thermal resistance of an LDB set, we propose and analyze a bypass heat sink with a top canopy structure for an LDB set, instead of adopting a thick submount. The thermal bypassing in the top-canopy structure is efficient, as it avoids the cross-sectional thermal saturation that may exist in a thick submount. The efficient thickness range of the submount in a typical LDB set is guided by the thermal resistance as a function of thickness, and the simulated bypassing efficiency of a canopy is higher than a simple analytical prediction, especially for thinner canopies.

2.5kW급 레이져 다이오드 구동 드라이버 개발 (A Study on the 2.5kW Laser Diode Driver)

  • 안준선;박동현;한유일;한경석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.59-60
    • /
    • 2014
  • In this paper, development of laser diode driver with 2.5kW rating is presented. The driver is configured with interleaved PFC converter, high frequency full bridge DC-DC converter, two laser diode drivers and ${\mu}$-processor based controller. The system has two laser diode drivers for providing high current and low current. High current driver delivers normal output power of diode; low current driver is for providing critical current of diode for long lifetime. Computer simulation and experiment was performed for verification, as the results, developed driver performs well.

  • PDF

TDLAS 시스템을 이용한 유해 배기가스의 농도 계측 (The Concentration Measurements of Toxic Exhaust Gas by Tunable Diode Laser Absorption Spectroscopy System)

  • 차학주;김민수;신명철;김세원;전광민
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.222-227
    • /
    • 2003
  • Recent advances in room-temperature, visible and near-IR diode laser sources for telecommunication, optical data storage applications are enabling combustion diagnostics system based on diode laser absorption spectroscopy. In contrast to some traditional sampling-based gas-sensing instruments, tunable diode laser absorption spectroscopy system is advantageous because of their non-invasive nature, high sensitivity, fast response time and real-time measurement capability. So, combined with fiber-optics and high sensitive detection strategies, compact and portable sensor system arc now appearing for a variety of applications. The objective of this research is to take advantage of distributed feed-back diode laser and measure the $CO_{2}$ concentration (by using direct absorption and wavelength modulation spectroscopy methods). In addition to survey spectra of $CO_{2}$ bands and spectroscopic parameters between 1565 and 1579 run were computed at temperatures between 296 and 1200 K (by using HITRAN 2000 database). It experimentally found out that the features of direct absorption and wavelength modulation spectroscopy methods.

  • PDF

렌즈형 광섬유를 이용하여 펄스형 반도체 레이저 Beam Shaping 및 증폭 기술 연구 (Simulation of Luminance and Uniformity of LGP According to the Laser Scattering Pattern)

  • 권오장;김륜경;심영보;한영근
    • 한국광학회지
    • /
    • 제21권6호
    • /
    • pp.254-258
    • /
    • 2010
  • 타원형 모양의 모드 형태를 갖는 펄스형 레이저 다이오드 (laser diode)의 펄스 형태를 유지하면서 단일 모드 및 Gaussian 형태로 광 모드 변환을 유도하고 광출력을 증폭할 수 있는 기술에 대해서 연구하였다. 실험에서 사용한 펼스형 레이저 다이오드의 구경이 가로는 $300{\mu}m$이며, 세로는 $2{\mu}m$이고 출력은 $1.1mW/cm^2$이다. 렌즈형 광섬유를 사용하여 광결합을 유도하여 단일 모드 및 Gaussian 형태의 출력으로 변환시켰다. 그러나, 다중모드의 펄스형 레이저 다이오드의 출력을 단일모드 렌즈형 광섬유에 결합시키면 출력이 급격하게 감소한다. 따라서 master oscillator power amplifier (MOPA) 기반의 광증폭 기술을 이용하여 레이저 다이오드의 광출력을 증폭시켰다. 증폭 후에도 펄스 성질은 그대로 유지되었고, MOPA구조를 지나 증폭된 광 출력은 $29mW/cm^2$로 측정되었다.

단일양자우물 Laser Diode에서 Stripe 폭이 문턱치에 미치는 영향 (Effect of Stripe Width on Threshold in Single Quantum Well Laser Diodes)

  • 이성재
    • 한국통신학회논문지
    • /
    • 제19권3호
    • /
    • pp.591-596
    • /
    • 1994
  • Gain-guided 구조를 갖는 단일양자우물 laser diode에서, stripe 폭에 따른 threshold의 변화를 복소수영역 유효굴적률방법을 이용하여 분석하였다. 분석결과 stripe 폭이 좁은 영역에서는, 측방향광집속률을 나타내기위하여 세롭게 도입된 변수 가 수직방향광집속률 가 감소함에따라 급격하게 감소하는 경향을 알아내었다. 따라서 일반적으로 매우작은 수직방향광집속률을 갖는 단일양자우물 laser diode에서는, stripe 폭의 크기에 따라서는 광집속률이 측방향은 물론 수직방향으로도 매우 나빠지게 됨으로 이득포와현상을 더욱 심하게시키게되며 경우에 따라서는 문턱전류가 비정상적으로 증가하는 현상으로 이어지게된다. 이와같은 문턱치의 stripe 폭에 대한 약간의 비정상적인 의존성을 이해하는 것은 양자우물 laser diode의 구조최적화에 있어서 매우 중요한 일이라고 판단된다.

  • PDF

반도체레이저 여기 세라믹 Nd:YAG 레이저에서 Q-스위칭 동작 최적화 (Optimization of Q-switched Operation at a Laser-Diode Pumped Nd:YAG Ceramic Laser)

  • 신동준;김병태;김덕래
    • 한국광학회지
    • /
    • 제19권4호
    • /
    • pp.320-326
    • /
    • 2008
  • 광섬유 연결 반도체레이저 여기 세라믹 Nd:YAG 레이저의 전기광학 Q-스위칭 출력 특성에 대해 연구하였다. 세라믹 Nd:YAG 레이저의 Q-스위칭은 여기원의 펄스폭 $1,000\;{\mu}s$, 출력 거울의 반사율 77% 및 지연시간 $985\;{\mu}s$에서 최적화되었다. 여기 에너지 17.9 mJ에서 0.35 mJ의 Q-스위칭된 출력 에너지와 약 4 ns의 펄스폭이 측정되어 1.9%의 출력 효율과 87.5 kW의 첨두 출력을 나타내었다.