• 제목/요약/키워드: Laser beam cutting

검색결과 77건 처리시간 0.022초

워터젯 노즐의 길이와 내부 나선 구조 유무에 따른 유체거동에 관한 전산해석 (A Study on the Simulation Analysis of Nozzle Length and Inner Spiral Structure of a Waterjet)

  • 곽청렬;신보성;고정상;김문정;유찬주;윤단희
    • 한국기계가공학회지
    • /
    • 제16권1호
    • /
    • pp.118-123
    • /
    • 2017
  • It is well known that water jetting is now widely used in the advanced cutting processes of polymers, metals, glass, ceramics, and composite materials because of some advantages, such as heatless and non-contacting cutting different from the laser beam machining. In this paper, we proposed the simulation model of waterjet by lengths and the inner spiral structure of the nozzle. The simulation results show that the outlet velocity of the nozzle is faster than the inlet. Furthermore, we found rapid velocity reduction after passing through the outlet. The nozzle of diameter ${\phi}500$ and length 70mm, shows the optimal fluid width and velocity distribution. Also, the nozzle with inner spiral structure shows a Gaussian distribution of velocity and this model is almost twice as fast as the model without spiral structure, within the effective standoff distance (2.5 mm). In the future, when inserting abrasive material into the waterjet, we plan to analyze the fluid flow and the particle behavior through a simulation model.

A Development of STL-Interfaced Constant-Speed Path Controller

  • Kim, Seungwoo;Minkook Ko;Jaechul Bang
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -3
    • /
    • pp.2027-2030
    • /
    • 2002
  • SFFS(Solid Freeform Fabrication System) is commercializing to rapid prototyping concept in world- wide some corporations including the U.S.A, have much technological problems yet and need new mode for agile solid freeform fabrication as well as prototyping. In this paper, we design an algorithm that the cutting path of laser beam, on the SFFS, is controlled with constant speed. The designed algorithm fer constant-speed path control is implemented and experimented in the CAFL$\^$VM/ (Computer Aided Fabrication of Lamination for Various Material) system, the new SffS which is developed in this paper. Finally, the ceramic, new material developed in this paper, cut and fabricated. The dimensional accuracy and mechanical stability of the 3D object is confirmed through the experiment, also.

  • PDF

Feasibility Study of a Custom-made Film for End-to-End Quality Assurance Test of Robotic Intensity Modulated Radiation Therapy System

  • Kim, Juhye;Park, Kwangwoo;Yoon, Jeongmin;Lee, Eungman;Cho, Samju;Ahn, Sohyun;Park, Jeongeun;Choi, Wonhoon;Lee, Ho
    • 한국의학물리학회지:의학물리
    • /
    • 제27권4호
    • /
    • pp.189-195
    • /
    • 2016
  • This paper aims to verify the clinical feasibility of a custom-made film created by a laser cutting tool for End-to-End (E2E) quality assurance in robotic intensity modulated radiation therapy system. The custom-made film was fabricated from the Gafchromic EBT3 film with the size of $8^{{\prime}{\prime}}{\times}10^{{\prime}{\prime}}$ using a drawing that is identical to the shape and scale of the original E2E film. The drawing was created by using a computer aided design program with the image file, which is obtained by scanning original E2E film. Beam delivery and evaluations were respectively performed with the original film and the custom-made film using fixed-cone collimator on three tracking modes: 6D skull (6DS), Xsight spine (XS), and Xsight lung (XL). The differences between total targeting errors of the original and custom-made films were recorded as 0.17 mm, 0.3 mm, and 0.17 mm at 6DS, XS, and XL tracking modes, respectively. This indicates that the custom-made film could yield nearly equivalent results to those of the original E2E film, given the uncertainties caused by distortions during film scanning and vibrations associated with film cutting. By confirming the clinical feasibility of a custom-made film for E2E testing, it can be expected that economic efficiency of the testing will increase accordingly.

칼코게나이드 As-Ge-Se-S 박막에서 홀로그래픽 격자의 에칭 특성 (Etching characteristics of holographic grating on chalcogenide As-Ge-Se-S thin films)

  • 박종화;박정일;나선웅;손철호;신경;이영종;정홍배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.644-647
    • /
    • 2001
  • Amorphous As-Ge-Se-S thin films have been studied with the aim of identifying optimum etching condition which can be used to produce holographic grating structure for use as diffractive optical elements. In this study, holographic gratings have been formed using He-Ne laser(632.8nm), and fabricated by the method of wet etching using NaOH etchant with various concentration(0.26N, 0.33N, 0.40N). The diffraction efficiency was obtained by +1st order intensity of the diffracted beam. The formed grating profiles were observed by atomic force microscope and showed that the expected grating profile could be achieved by controlling the etching time. Over-etching resulted in under-cutting of the grating lines. The highest 1st order diffraction efficiency for these gratings was about 5.05%.

  • PDF

Breakage Detection of Small-Diameter Tap Using Vision System in High-Speed Tapping Machine with Open Architecture Controller

  • Lee, Don-Jin;Kim, Sun-Ho;Ahn, Jung-Hwan
    • Journal of Mechanical Science and Technology
    • /
    • 제18권7호
    • /
    • pp.1055-1061
    • /
    • 2004
  • In this research, a vision system for detecting breakages of small-diameter taps, which are rarely detected by the indirect in-process monitoring methods such as acoustic emission, cutting torque and motor current, was developed. Two HMI (Human Machine Interface) programs to embed the developed vision system into a Siemens open architecture controller, 840D, were developed. They are placed in sub-windows of the main window of the 840D and can be activated or deactivated either by a softkey on the operating panel or the M code in the NC part program. In the event that any type of tool breakage is detected, the HMI program issues a command for an automatic tool change or sends an alarm signal to the NC kernel. An evaluation test in a high-speed tapping machine showed that the developed vision system was successful in detecting breakages of small-diameter taps up to M1.

Effects of HA and TiN Coating on the Electrochemical Characteristics of Ti-6Al-4 V Alloys for Bone Plates

  • Oh, Jae-Wook;Choe, Han-Cheol;Ko, Yeong-Mu
    • 한국표면공학회지
    • /
    • 제37권5호
    • /
    • pp.249-252
    • /
    • 2004
  • Effects of HA and TiN coating on the electrochemical characteristics of Ti-6AI-4V alloys for bone plates were investigated using various test methods. Ti-6AI-4V alloys were fabricated by using a vacuum induction furnace and bone plates were made by laser cutting and polishing. HA was made of extracted tooth sintered and then tooth ash was used as HA coating target. The TiN and HA film coating on the surface were carried on using electron-beam physical vapor deposition (EB-PVD) method. The corrosion behaviors of the samples were examined through potentiodynamic method in 0.9% NaCI solutions at $36.5\pm$$1^{\circ}C$ and corrosion surface was observed using SEM and XPS. The surface roughness of TiN coated bone plates was lower than that of tooth ash coated plates. The structure of TiN coated layer showed the columnar structure and tooth ash coated layer showed equiaxed and anisotrophic structure. The corrosion potential of the TiN coated specimen is comparatively high. The active current density of TiN and tooth ash coated alloy showed the range of about $1.0xl0^{-5}$ $A\textrm{cm}^2$, whereas that of the non-coated alloy was$ 1.0xl0^{-4}$ $A\textrm{cm}^2$. The active current densities of HA and TiN coated bone plates were smaller than that of non-coated bone plates in 0.9% NaCl solution. The pitting potential of TiN and HA coated alloy is more drastically increased than that of the non-coated alloy. The pit number and pit size of TiN and HA coated alloy decreased in compared with those of non-coated alloy. For the coated samples, corrosion resistance increased in the order of TiN coated, tooth ash coated, and non-coated alloy.

조직투명화 기술을 통한 3차원적 접근 (Three-Dimensional Approaches in Histopathological Tissue Clearing System)

  • 이태복;이재왕;전진현
    • 대한임상검사과학회지
    • /
    • 제52권1호
    • /
    • pp.1-17
    • /
    • 2020
  • 조직병리학에서 현미경을 이용한 삼차원적 접근법은, 이차원 단면의 조직 슬라이드에서 박절 과정 중 부차적으로 발생하는 공간정보의 손실로 인하여 확인하기 어려웠던, 조직 내부 분자들의 공간적 배열, 상호결합, 구조적인 형태와 이들의 통합적인 공간적 정보체로서, 조직 내에 복잡하게 얽혀진 다양한 정보를 풀어내는데 있어서 복합적인 데이터를 제시하여 준다. 이광자 현미경(two-photon microscope)과 자동화된 보정환(correction collar)이 탑재된 고성능 대물렌즈의 개발과 같은 광학장비 영역의 발전은 조직투명화 과정을 거치지 않은 두꺼운 시료의 이미징에 있어서 광학적인 이론과 실체 사이에 존재하는 격차를 줄이는데 기여하였다고 할 수 있다. 하지만, 대물렌즈의 길어진 작동범위(working distance)와 최적화된 고강도 레이저의 사용으로 얻게 되는 이점들은 세포 내 각 구성요소의 굴절률(refractive index) 차이로 인하여 증가되는 빛의 분산(light scattering) 현상으로 인해 자연스럽게 감소하게 된다. 조직투명화 기술이 처음 등장하였던 초창기 시도되던 간단한 굴절률 일치화(RI matching) 기법에서부터 현대의 최첨단 통합 조직 투명화 기술에 이르기 까지를 관찰하여 볼 때, 형태학적인 변화없이 조직의 투명도를 높이는 것과, 내재적으로 또는 고정과정 중에 유래되어 혼합된 자가형광 노이즈를 효과적으로 제거하는것이 선명한 이미지를 얻기 위한 주요한 고려대상이라고 할 수 있다. CLARITY는 장비에 기반한 조직투명화 기법으로서 임상 조직병리 실험실에서 처리되는 동결절편과 포르말린에 고정된 검체 모두의 투명화를 위한 실험실 작업흐름(workflow) 통합 및 일상적인 실험절차와 호환이 가능할 것으로 보여진다.