• 제목/요약/키워드: Laser Vibration Measurement

검색결과 130건 처리시간 0.025초

가속도계 정밀 위상 교정 시스템 (Precision Phase Calibration System of Accelerometers)

  • 이용봉;정성수;진종한
    • 한국정밀공학회지
    • /
    • 제28권5호
    • /
    • pp.585-590
    • /
    • 2011
  • Accelerometers have been exploited widely in various fields from monitoring vibration of precision machines to detecting an earthquake wave. The precision calibration of the accelerometers is required to maintain the measurement reliability when measuring the vibration of objects with accelerometers for modal analysis. Among evaluation factors for determining sensitivity of accelerometers, phase delay term should be also considered for accurate calibration. In this paper, a new calibration system of accelerometers capable of measuring phase delay as well as magnitude of its sensitivity was proposed and realized in the frequency range of 20 Hz to 5 kHz.

폭발볼트와 착화기의 파이로충격 계측 및 특성 분석 (Pyroshock Measurement and Characteristic Analysis of Explosive Bolt and Pyrotechnic Initiator)

  • 이주호;황대현;장재경;이응조;김동진;이정률;한재흥
    • 한국소음진동공학회논문집
    • /
    • 제27권2호
    • /
    • pp.213-220
    • /
    • 2017
  • Pyroshock produced by the pyrotechnic devices can induce failures in nearby electronic devices. To handle and mitigate pyroshock inducing problems, appropriate measurement of pyroshock is essential. In this study, pyroshock measurement technique is established using laser Dopper vibrometers (LDVs) and shock accelerometers. Pyroshock produced by the explosive bolts and the pyrotechnic initiators under various environments is measured. The characteristics of pyroshock including the effects of supporting structures, propagation form on thin plate, sensor (contact and non-contact) types are discussed.

광학적 면내 진동 측정기어 의한 불균일 도파관의 비틀림 진동 측정 (Measurement of the Torsional Vibrations in Nonuniform Waveguides by Using an In-plane Laser Vibrometer)

  • 정형곤;김진오
    • 비파괴검사학회지
    • /
    • 제24권3호
    • /
    • pp.240-245
    • /
    • 2004
  • 불균일한 원형 도파관에서 비틀림 진동을 광학적 면내 진동 측정기에 의해 측정하였다. 봉의 한쪽 끝에서 가진되는 비틀림 진동의 응답으로서 봉의 축을 따라 원주 방향 변위가 측정되었다. 2단 원형 봉과 원추형 테이퍼 봉에 대한 실험 결과들이 이론적 예측과 비교되었다. 본 논문의 결과들은 비틀림 진동 측정에 광학적 면내 진동 측정기를 사용하는 것이 가능함을 보여준다.

모델 기반 외란 관측기와 Waterfall 해석을 이용한 광 디스크 외란 분석 (Disturbance Analysis in an Optical Disk Drive Using Model Based Disturbance Observer and Waterfall Technique)

  • 최진영;이광현;전홍걸;이문노;양현석;박노철;박영필
    • 한국소음진동공학회논문집
    • /
    • 제16권1호
    • /
    • pp.40-49
    • /
    • 2006
  • A novel disturbance measurement method, model based disturbance observer (MBDO) for optical disk drives (ODDs), is proposed and the disturbance analysis using the proposed method is performed under various conditions. In ODDs, the quantitative and qualitative analysis for the generated disturbance during normal operation is very important to successful servo loop design. However, the disturbance measurement is difficult, and high precision measurement is necessary. Furthermore, the conventional disturbance measurement method using a LDV (laser Doppler vibrometer) has many difficulties in eccentricity direction due to the vertical movement of an optical disk. To solve this problem, the MBDO is proposed. First, the relationship between the servo loop for ODDs and the generated disturbance are briefly reviewed. Second, the principle of the MBDO is introduced, and the disturbance measurement results, which are measured by the MBDO and a LDV, are compared. In these experiments, test DVD-ROM disks are used to generate quantitative/qualitative disturbance. Then, the disturbance analysis under various conditions is performed using waterfall technique. This technique clearly shows the disturbance trend from the inner part of an optical disk to the outer part of it. Finally, the various disturbances measurement results are summarized and some remarks for it are commented.

전기기기의 진동측정을 위한 레이저 진동계의 개발 (The development of Laser Vibrometer for the measurement of vibration of electric machinery)

  • 김성훈;김호성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1867-1870
    • /
    • 1997
  • A Laser Doppler Vibrometer (LDV) based on the heterodyne method was developed using He-Ne laser as a light source. The heterodyne method was employed to eliminate the ambiguity in the direction of the motion. The frequency shifted object beam (40 MHz) by a Bragg cell was focused on the surface of the moving target and the Doppler shifted reflected beam was combined at the fast photodetector to produce frequency modulated signal centered at 40 MHz. The signal from the detector was amplified, filtered and downconverted to intermediate frequency centered at 5 MHz. The voltage output that was proportional to the velocity of the moving surface was obtained using PLL. This LDV can be used to measure the resonant frequency of the electric equipments such as circuit breakers and bushings, of which resonant frequencies are changed when they are damaged.

  • PDF

진동 감시용 위치 결정 센서의 위상오차에 대한 실험적 고찰과 비교평가 (The Experimental Study and Comparison on Usage of Vibration Monitoring Sensors for Positioning of Balancing on Rotating Machinery)

  • 오승태;유무상;봉석근
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.314-320
    • /
    • 2014
  • Field balancing is required in any kind of phase information for the determination location balancing mass toward a rotor unbalance mass. Phase or phase angle is a measurement of the relationship of how one vibration signal which relates to another vibration signal and is commonly used to calculate the placement of balance weight. In this paper, A right guideline shows the photo optical speed sensor as the external keyphasor is a very useful when diagnosing machinery vibration problems on considering a phase lag comparing to the laser optical speed sensor. Some experimental results generate the interesting phase errors when appling to a wrong conditions. So, Usage of photo optical speed sensor which is used primarily to measure the shaft rotating speed serves as a reference for measuring vibration phase information has effect on the placement of phase angle how it was misunderstood. This paper will help a right method to search for the position of balancing weight and serves as baseline for further measurements using low cost and much easier user convenience. It is concluded that the propose baseline is likely to be applicable to apply to the practical field balancing weight.

  • PDF

진동 감시용 위치 결정 센서의 위상오차에 대한 실험적 고찰과 비교 평가 (The Experimental Study and Comparison on Usage of Vibration Monitoring Sensors for Positioning of Balancing on Rotating Machinery)

  • 오승태;유무상;봉석근
    • 한국소음진동공학회논문집
    • /
    • 제25권2호
    • /
    • pp.101-107
    • /
    • 2015
  • Field balancing is required in any kind of phase information for the determination location balancing mass toward a rotor unbalance mass. Phase or phase angle is a measurement of the relationship of how one vibration signal which relates to another vibration signal and is commonly used to calculate the placement of balance weight. In this paper, A right guideline shows the photo optical speed sensor as the external KeyPhasor is a very useful when diagnosing machinery vibration problems on considering a phase lag comparing to the laser optical speed sensor. Some experimental results generate the interesting phase errors when appling to a wrong conditions. So, Usage of photo optical speed sensor which is used primarily to measure the shaft rotating speed serves as a reference for measuring vibration phase information has effect on the placement of phase angle how it was misunderstood. This paper will help a right method to search for the position of balancing weight and serves as baseline for further measurements using low cost and much easier user convenience. It is concluded that the propose baseline is likely to be applicable to apply to the practical field balancing weight.

레이저진동계를 사용한 동조액체댐퍼의 액체 진동 측정 (Measurement of Liquid Oscillation in Tuned Liquid Dampers using a Laser Doppler Vibrometer)

  • 신윤수;민경원;김준희
    • 한국전산구조공학회논문집
    • /
    • 제29권6호
    • /
    • pp.513-519
    • /
    • 2016
  • 본 논문에서는 기존 파고 측정 센서의 한계를 극복하기 위하여 레이저 장비 중 LDV를 이용하여 동조액체기둥감쇠기 안의 액체의 파고를 측정하는 방법을 제안하고 검증하였다. 비접촉 센서의 장점과 LDV가 속도와 변위를 측정하는 원리를 기술하였고 대상 물체가 액체인 경우에 요구되는 사항들에 대하여 실험적으로 파악하였다. 투명한 액체는 레이저 광선을 대부분 투과시켜 LDV에 되돌아오는 광량이 부족해 측정이 불가능함을 확인하였고 이를 증가시키기 위해 염료를 혼합하였다. 이때, 염료의 색에 따라 광량에 차이가 발생함을 확인하여 LDV에 사용된 레이저 광선의 파장과 연관된 결과를 도출하였다. 염료를 혼합한 후 광량이 충분한 경우에도 발생하는 데이터의 오차를 제거하기 위해 염료의 농도를 변화시키며 그에 따른 데이터의 정확도를 파악하였다. 결과적으로 모든 가시광선의 빛을 반사시키는 흰색의 염료를 충분한 농도로 혼합하였을 때 LDV를 이용한 TLCD의 파고 측정의 실험적인 결과가 용량식 파고계와 일치함을 확인하였다.

고감도 레이저 간섭계를 이용한 미소 진동 진폭의 정밀측정 (Ultrasensitive laser interferometer for precision measurement of small vibration displacement)

  • 서상준
    • 대한기계학회논문집
    • /
    • 제12권3호
    • /
    • pp.440-449
    • /
    • 1988
  • 본 연구에서는 미소한 진동진폭의 정밀한 측정을 위해 비교적 광선정렬(opti- cal alignment)이 쉽고 광손실이 적으며 국소부위의 진동측정이 가능한 다중반사계를 Michelson간섭계에 도입하였다.미소 진동진폭의 정밀한 값을 결정하기 위해서는 간 섭신호를 측정하여 간섭무늬 보간법과 곡선 맞춤법을 이용하는 방법이 있다. 전자는 간단한 계산과 시간을 절약할 수 있는 반면 후자는 복잡한 계산으로 인해 많은 시간이 소요된다. 그러나 정밀계측장비의 교정에서와 같이 경우에 따라서는 많은 시간과 노 력이 소요되더라도 정밀한 측정결과를 얻어야할 필요가 있기 때문에 이들 두가지 방법 의 정밀도를 확인하기 위해 컴퓨터에 의한 모의실험을 수행하였다.

강체의 6자유도 미소 변위 측정 (Measurement Method for Fine 6-DOF Displacement of Rigid Bodies)

  • 박원식;조형석
    • 제어로봇시스템학회논문지
    • /
    • 제8권3호
    • /
    • pp.208-219
    • /
    • 2002
  • A novel measurement method to obtain the 6-DOF motions of arbitrary rigid bodies is proposed in this paper. The method adopts a specially fabricated mirror called 3-facet mirror, which looks like a triangular pyramid haying an equilateral cross-sectional shape. The mirror is mounted on the objects to be measured, illuminated by a laser beam having circular profile, and reflects the laser beam in three different directions. Three PSDs(position sensitive detector) detect the three beams reflected by the mirror, respectively. From the signals of the PSDs, we can calculate the 3-dimensional position and orientation of the 3-facet mirror, and thus enabling us to determine the 3-dimensional position and orientation of the objects. In this paper, we model the relationship between the 3-dimensional position and orientation of an object in motion and the outputs of three PSDs. A series of experiments are performed to demonstrate the effectiveness and accuracy of the proposed method. The experimental results show that the proposed sensing system can be an effective means of obtaining 3-dimensional position and orientation of arbitrary objects and provide resonable measurement accuracy.