• 제목/요약/키워드: Laser Vibration Measurement

검색결과 130건 처리시간 0.021초

레이저 계측기를 이용한 축의 비틀림 진동에 관한 실험적 기초 연구 (The Experimental and Basic Study on Torsional Vibration of Horizontal Rotating Shaft using a Laser Measuring Equipment)

  • 박일수
    • 동력기계공학회지
    • /
    • 제13권1호
    • /
    • pp.33-38
    • /
    • 2009
  • In this study, the nose of cam in the automobile engine was modelled into circular disk to analyze the torsional vibration of the cam shaft. The distance between disks was fixed, but the diameter of disks was changed. The torsional vibration of the cam shaft was studied experimentally by the motion of the modelled disk with changing the disk diameter. And the sizes of the modelled disk were selected not to show the natural frequencies over all the experimental ranges. The torsional vibration meter used in this study has a laser system with non-contact measurement method, which can measure both torsional angular vibration velocity and torsional angular vibration displacement simultaneously. The Experimental analysis shows that the characteristics of the torsional vibration in the horizontal rotating shaft can be considerably affected by the arrangement of the modelled disks.

  • PDF

$CO_2$ Laser Absorption Measurement of $CH_3CH_2Br$ using Photoacoustic Method

  • Jang Soo Shin;Kyung Hoon Jung;Cheol Jung Kim
    • Bulletin of the Korean Chemical Society
    • /
    • 제13권5호
    • /
    • pp.553-556
    • /
    • 1992
  • The ${CO}_2$ laser absorption measurement of ${CH}_3{CH}_2Br$ utilizing photoacoustic (PA) technique was performed using a cw and a pulsed ${CO}_2$ lasers. The absorption profile in the ${CO}_2$ laser wavelength region (9-10 ${\mu}$m) and the macroscopic small signal absorption cross section at 10P(20) (10.59 ${\mu}$m, 944 $cm^{-1}$) laser line were measured using a cw ${CO}_2$ laser. The laser fluence dependence on infrared multiphoton absorption (IRMPA) was also studied with a pulsed TEA ${CO}_2$ laser at 10P(20) laser line. In view of monotonic increase of PA signal with the rise of laser fluence, it was suggested that the anharmonicity in pumped vibration mode did not restrict ir multiphoton absorption in ${CH}_3{CH}_2Br$ system as found in large molecular system.

카메라를 이용한 진동 측정 시 주요인자 분석 (Parameter Studies for Measuring Vibration by Using Camera)

  • 전형섭;최영철;박진호;박종원
    • 한국소음진동공학회논문집
    • /
    • 제20권11호
    • /
    • pp.1033-1037
    • /
    • 2010
  • Accelerometer and laser vibrometers are widely used to measure vibration of structures like a building or piping. Recently, the research measuring vibration by using camera image is introduced. This method can measure multi-points simultaneously. Also, it is possible to measure in the long distance. When we measure the vibration using a camera, the parameter analysis is needed. Therefore, this paper took the experiment for the camera lens selection. An error by the camera images characteristic was theoretically analyzed and we verified through an experiment. And the accuracy of the method measuring the vibration displacement by using the camera images was analyzed.

고속 스핀들의 변위측정 시스템 개발 (Development of a Measurement System for High-Speed Spindle Displacement)

  • 김효곤;정원지;주지훈;조영덕
    • 한국공작기계학회논문집
    • /
    • 제17권6호
    • /
    • pp.8-13
    • /
    • 2008
  • At present many research projects on high-speed spindles are being conducted. These projects require a measurement technique which includes heat expansion, vibration and displacement measurement according to angular velocity. This paper presents the development of a measurement system for high-speed spindle displacement. The measurement system is based on $LabView^{(R)}$ and features the following sensors: optical sensor which reacts to the position of a marker on the spindle and enables two Laser Displacement Sensors(LDS). These Laser Displacement Sensors send their data to a DAQ(Data Acquisition Device). It is important that the delay time caused by the response times of the sensors as well as the sampling rate of the DAQ is considered because the spindle revolves at very high speeds.

평면 구조 진동 측정을 위한 자동화된 스캐닝 레이저 도플러 진동측정기의 개발 및 연구 (Development of An Automated Scanning Laser Doppler Vibrometer for Measurements of In-Plane Structural Vibration)

  • Kil, Hyun-Gwon
    • 소음진동
    • /
    • 제7권2호
    • /
    • pp.231-238
    • /
    • 1997
  • 진동하는 구조물의 평면 진동장을 측정하기 위해, 자동화된 스캐닝 레이저 도플러 진동 측정기를 개발하고 이의 성능을 시험하였다. 광섬유를 사용하여 레이저 탐침이 진동체 표면을 따라 움직일 수 있도록 하였으며, 시스템의 자동화를 이루기 위한 알고리즘을 고안하였다. 시스템의 자동화과정은, 레이저 탐침이 진동체 표면을 따라 움직이도록 하며, 표면의 각 측정 점마다 두 레이저 광선들의 초점을 맞추고, 진동 신호 데이터를 얻고 저장하는 모든 과정을 포함한다. 따라서 이 자동화 과정을 이용하여 구조물의 표면 진동장을 측정할 수 있도록 하였다. 이 진동 측정기의 성능을 시험하기 위하여, 연속신호로 가진되는 압전 원통 셸의 진동과 펄스 신호에 의해 가진되는 평판의 진동을 측정하였다. 측정결과로부터, 구조물의 평면 진동장을 측정하고 표면을 따라 전파되는 탄성파들을 분리해내기 위하여, 이 자동화된 스캐닝 레이저 도플러 진동 측정기가 유용한 측정 도구가 될 수 있음을 보였다.

  • PDF

단을 가진 수평축의 비틀림진동 측정에 관한 연구 (A Study on the Torsional Vibration Measurement of the Horizontal Shaft with Disks)

  • 박일수;안찬우;김중완
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.3-8
    • /
    • 1997
  • This parer was presented for the experimental results of torsional vibrations of the horizontal rotating shaft with three disks. The torsional vibrations meter used is a laser system for non-contact measurement of torsional angular vibration velocity and torsional angular vibration displacement. The distance between the disks war changed; the one that had 76mm of disk distance war called basic model, and another that had 106mm of disk distance wide model, and other that had 46mm of disk distance narrow model. In each model, outer diameter of disk was 40mm. And 45mm, or 50mm was also used to extend the effective range of frequencies. The angula vibration displacement and the angular vibration velocity in its torsional vibration were measured to obtain the stable and the unstable regions.

  • PDF

카메라 영상을 이용한 진동 변위 측정 시 카메라 흔들림 보정 방법 (Correction of Error due to Camera Shaking when Vibration Measurement by Using Camera Image)

  • 전형섭;손기성;한순우;박종원
    • 한국소음진동공학회논문집
    • /
    • 제24권10호
    • /
    • pp.817-824
    • /
    • 2014
  • Accelerometer and laser vibrometers are widely used to measure vibration of structures like a building or piping. Recently, the research measuring vibration by using camera image is introduced. However, this method has a disadvantage. If camera moves by the vibration cannot measure the vibration displacement of structure. We proposed the enhanced technique for measuring vibration using camera. This paper took the experiment for correction of error due to camera shaking. We verified through an experiment. And the accuracy of the method measuring the vibration displacement by using the camera images was analyzed.

레이저 3차원 진동측정기와 마이크로폰을 이용한 진공청소기용 팬모터의 실험적인 공력소음 분석 (The Experimental Analysis of Aerodynamic Sound for Fan Motor in a Vacuum Cleaner Using Laser 3-D Scanning Vibrometer and Microphone)

  • 곽이구;안재신;김재열
    • 한국정밀공학회지
    • /
    • 제22권3호
    • /
    • pp.46-51
    • /
    • 2005
  • The vacuum cleaner motor runs at very high speed for suction power. Specially, motor power is provided by the impeller being rotated at very high speed. The centrifugal fan consists of the impeller, the diffuser, and the circular casing. Due to the high rotating speed of the impeller and small gap distance between the impeller and the diffuser, the level of noise in the centrifugal fan is at BPF(Blade Passage Frequency) and its harmonic frequencies. In order to calculate the sound pressure of centrifugal fan, unsteady flow data are needed. The cause of noise is obtained by dividing the fluid noise by exhaust flow of fan and vibration noise by rotational vibration of vacuum cleaner fan motor. Until now, an accelerometer has been used to measure vibration. However, it can not measure vibration in some parts of brush and commutator because of motor construction and 3-D vibrating mode. This study was conducted to perform accurate analysis of vibration and aerodynamic sound for fan motor in a vacuum cleaner using a laser vibration analyzer. A silent fan motor can be designed using the data measured in this study.

하드디스크 서스펜션의 초음파 진동측정 기술 (AN ULTRASONIC METHOD FOR VIBRATION MEASUREMENT OF THE SUSPENSION IN HARD DISK DRIVES)

  • 하완;김노유
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.720-725
    • /
    • 2000
  • A new ultrasonic pulse-echo technique was developed and described for vibration measurement of the suspension assembly in hard disk drives. The method is based upon the difference in magnitude of two consecutive reflection waves from a moving object(suspension), while the traditional ultrasonic vibrometer uses the phase shift of the reference wave and the reflection wave. A cone-shape delay line is designed to access the small structure. A simple mathematical model is presented and analyzed with experimental results to show the feasibility of the method. The advantages of this ultrasonic vibration measurement method are relatively high resolution, low cost, and ease of implementation comparing with the Laser Doppler vibrometer.

  • PDF

액체거동의 비접촉 다점측정을 위한 레이저진동계와 갈바노미터스캐너 계측시스템 (Measurement System of Dynamic Liquid Motion using a Laser Doppler Vibrometer and Galvanometer Scanner)

  • 김준희;신윤수;민경원
    • 한국전산구조공학회논문집
    • /
    • 제31권5호
    • /
    • pp.227-234
    • /
    • 2018
  • 슬로싱과 같은 액체의 동적 거동을 측정하고 제어하는 연구가 다양한 공학분야에서 활발히 진행중이다. 건축공학분야에서도 건축물의 풍진동을 저감시키는 동조액체감쇠기의 연구에 액제 진동이 측정되고 있다. 본 논문에서는 기존 파고 측정 센서의 한계를 극복하기 위하여 레이저 장비 중 LDV와 스캐닝 장비 중 갈바노미터스캐너를 이용하여 동조액체감쇠기 내의 액체 진동을 측정하는 방법을 제안하고 검증하였다. LDV가 속도와 변위를 측정하는 원리를 기술하였고 갈바노미터스캐너의 구동 원리에 따라 LDV의 단일 포인트로 다점측정이 가능한 시스템을 구성하였다. 동조 액체감쇠기의 4점 액체 진동을 측정하여 각 점의 시간 영역 데이터를 기존에 사용하던 비디오 센싱 데이터와 비교하였고 파형 분석을 통해 진행파와 정상파를 구별할 수 있음을 확인하였다. 또한 측정 딜레이가 있는 데이터를 상호 상관을 취하여 특이값 분해를 하고 이론 및 비디오 센싱 결과와 일치하는 고유진동수와 모드형상을 도출하였다.