• 제목/요약/키워드: Laser Vibration Measurement

검색결과 130건 처리시간 0.026초

EVALUATION OF VOLUME VELOCITY OF A LOUDSPEAKER IN A CHAMBER

  • Lee, J.S.;Ih, J.G.
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1994년도 FIFTH WESTERN PACIFIC REGIONAL ACOUSTICS CONFERENCE SEOUL KOREA
    • /
    • pp.770-774
    • /
    • 1994
  • The volume of an acoustic source is important in determining various acoustic parameters. One of the suggested techniques is the internal pressure method incorporating a loudspeaker attached to a chamber wall and a microphone inserted into the cavity. Although the method is easy to handle with a very simple measurement setup, the coupling effects between the dynamic system of the loudspeaker and acoustic field, and the effects of higher order modes introduced by the discontinuities in the acoustic field, and the effects of higher order modes introduced by the discontinuities in the acoustic field should be considered for precise result. In this study, higher order modes due to the discontinuities of loudspeaker and microphone boundaries are included and the electro-acoustic coupling effects are compensated for by using the results of two cylinders with different lengths. The volume velocity of a loudspeaker thus obtained agrees very with that measured by laser sensor.

  • PDF

카메라를 이용한 고압 증기 배관 누설/진동 감시시스템 개발 (Development of Leak and Vibration Monitoring System for High Pressure Steam Pipe by Using a Camera)

  • 전형섭;서장수;채경선;손기성;김세오;이남희
    • 비파괴검사학회지
    • /
    • 제36권6호
    • /
    • pp.496-503
    • /
    • 2016
  • 발전소나 석유화학 플랜트 구조물에 누설이 발생하면 인명 피해 및 경제적인 손실을 초래한다. 이러한 누설은 플랜트 배관의 진동으로 인한 피로파괴나 배관 감육으로 인해 발생한다. 플랜트 배관의 진동을 감시하기 위한 방법으로 주로 가속도센서나 레이저센서가 사용되지만 설치 및 운용의 어려움이 따르고 동시에 광범위 측정 시 비용 증가가 발생하게 된다. 이러한 문제점들을 해결하기 위해 최근 카메라를 이용한 누설 및 진동 변위 측정 방법에 대한 연구가 이루어지고 있다. 카메라를 이용한 누설 및 진동 변위 측정 방법은 설치가 간단하고 원거리 측정 및 넓은 범의의 측정이 가능한 장점을 가지고 있다. 따라서 본 연구에서는 카메라를 이용해 누설 및 진동 변위를 측정할 수 있는 시스템을 개발하였고 실험을 통해 성능을 검증하였다.

고 분해능 레이저 도플러 진동계의 개발 (Development of High Resolution Laser Doppler Vibrometer)

  • 김성훈;고진환;김호성
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권2호
    • /
    • pp.125-131
    • /
    • 2000
  • A high resolution Laser Doppler Vibrometer(LDV) developed using electronic fringe counting method. The fringe pattern signal obtained via analog signal processing is divided into two. One was converted to a TTL signal with a ZCD(zero-crossing detector) and then counted to calculate the displacement due to the vibration. The other was directed to the A/D converter to get a high resolution of about $\lambda/320$ with the phase comparison method. The data obtained with the A/D converter was used in the displacement calculation and the result was displayed on a LCD pane. In this study, a Laser Doppler Vibrometer with measurement range of $0.32\mum~129\mum$ and displacement resolution of 2nm, about $\lambda/320$ , was developed. And this LDV can be used to measure the dynamic of microsize devices such as MEMS(Micro Electro-Mechanical Systems) and to diagnose high capacity electric equipment such as circuit breakers and transformers, of which resonant frequencies are changed when they are damaged.

  • PDF

레이저 도플러 진동계를 이용한 진동변위와 주파수 측정방법 연구 (A Study on the method for the measurement of vibrating amplitude and frequency with Laser Doppler Vibrometer)

  • 김성훈;김호성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1824-1827
    • /
    • 1998
  • A Laser Doppler Vibrometer(LDV) was developed using He-Ne laser as a light source. The heterodyne method was employed and its output signal was digitally processed with a $\mu$-processor and the result was displayed with LCD. The frequency shifted object beam(40 MHz) by a Bragg cell was focused on the surface of the moving target and the Doppler shifted reflected beam was recombined with reference beam at the fast photodetector to produce frequency modulated signal centered at 40 MHz. The signal from the detector was amplified and downconverted to intermediate frequency centered at 1 MHz after mixing process. The voltage output that was proportional to the velocity of the moving surface was obtained using PLL. With the same method, the fringe pattern signal of the moving surface is obtained. This fringe pattern signal is converted to TTL signal with ZCD(zero-crossing detector) and then counted to calculate the displacement due to the vibration, which is displayed with LCD. This LDV can be used to measure the resonant frequency of the electric equipments such as circuit breakers and transformers, of which resonant frequencies are changed when they are damaged.

  • PDF

초음파가 가진된 유체유동의 PIV계측에 의한 연구 (A Study on the Fluid Flew with Ultrasonic Forcing by PIV Measurement)

  • 주은선;이영호;나우정;정진도
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권6호
    • /
    • pp.1281-1290
    • /
    • 2001
  • A study on the fluid flow with ultrasonic forcing is carried out to obtain data for the turbulence enhancement. A large water tank is made of the transparent acrylic plates and a horizontal flow field is given by setting two acrylic tubes to face mutually on a horizontal line. A 2-dimensional PlV system which is composed of a continuous-output 4W Argon-ion laser, a high-speed video camera, a PC based by an image grabber and a high resolution monitor is used to investigate characteristics of the complex turbulence flow field. And a 2MHz ultrasonic transducer is used fur ultrasonic vibration forcing. Some experiments are carried out at Reynolds numbers of 2,000 and 4,000 and at 7 angles of ultrasonic incidence. In results, the flew velocity vector distribution, kinetic energy and turbulence intensity in both cases of with and without ultrasonic forcing are examined, compared and discussed by using PIV measurement. It is clarified that the ultrasonic forcing into flow field is valid to obtain the turbulence enhancement.

  • PDF

A noble RBC aggregometer with vibration-induced disaggregation mechanism

  • Shin S.;Jang J.H.;Park M.S.;Ku Y.H.;Suh J.S.
    • Korea-Australia Rheology Journal
    • /
    • 제17권1호
    • /
    • pp.9-13
    • /
    • 2005
  • The aggregation of red blood cells (RBCs) is a major determinant of blood flow resistance passing through various veins. Available techniques for measuring RBC aggregation often require pretreating and washing after each measurement, which is not optimal for day-to-day clinical use. A laser reflection technique has been combined with a vibration-aided disaggregation mechanism, which shows significant advances in aggregometer design, operation and data analysis. The essential features of this design are in its simplicity and a disposable element that is in contact with the blood sample. Using extremely small quantities of blood, the RBCs subjected to vibrations can be quickly and completely disaggregated. This is followed by measuring the backscattered light intensity. The measurements with the present sensor were compared with those of a commercial aggregometer and a strong correlation was found between them. The newly-developed optical aggregometer can measure the RBC aggregability difference between young and old cell suspension with ease and accuracy.

Dynamic torsional response measurement model using motion capture system

  • Park, Hyo Seon;Kim, Doyoung;Lim, Su Ah;Oh, Byung Kwan
    • Smart Structures and Systems
    • /
    • 제19권6호
    • /
    • pp.679-694
    • /
    • 2017
  • The complexity, enlargement and irregularity of structures and multi-directional dynamic loads acting on the structures can lead to unexpected structural behavior, such as torsion. Continuous torsion of the structure causes unexpected changes in the structure's stress distribution, reduces the performance of the structural members, and shortens the structure's lifespan. Therefore, a method of monitoring the torsional behavior is required to ensure structural safety. Structural torsion typically occurs accompanied by displacement, but no model has yet been developed to measure this type of structural response. This research proposes a model for measuring dynamic torsional response of structure accompanied by displacement and for identifying the torsional modal parameter using vision-based displacement measurement equipment, a motion capture system (MCS). In the present model, dynamic torsional responses including pure rotation and translation displacements are measured and used to calculate the torsional angle and displacements. To apply the proposed model, vibration tests for a shear-type structure were performed. The torsional responses were obtained from measured dynamic displacements. The torsional angle and displacements obtained by the proposed model using MCS were compared with the torsional response measured using laser displacement sensors (LDSs), which have been widely used for displacement measurement. In addition, torsional modal parameters were obtained using the dynamic torsional angle and displacements obtained from the tests.

플레이트형 지지구조체로 지지된 실린더형 관 군의 고주파 유동유발진동 및 압력손실에 대한 실험적 고찰 (Experimental investigation on the high frequency flow-induced vibration and pressure drop of cylindrical tube bundle with plate type supporting structures)

  • 이강희;김형규;윤경호;엄경보;김진선;서정민
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1367-1372
    • /
    • 2008
  • A plate type supporting structure of a tube bundle in axial flow generates a certain band of a high frequency periodic excitation of a vortex shedding and/or a flow separation due to sharp edge of the plate thickness and a severe pressure drop due to a cross-sectional area of the supports. With a design consideration of the low vibration and a small flow resistance, the analysis method is uniquely confined to an experimental approach because a complex geometry of a cylindrical tube bundle and/or physical phenomena related to the fluid-structure interaction of tube bundle in a flow impede a theoretical or a numerical approach. A 5x5 cylindrical tube bundle with 5 supports which were discretely located along the bundle's axis was tested in the FIVPET hydraulic test loop for a design evaluation and an analysis perspectives. A high frequency flow-induced vibration of the supporting structures of the cylindrical tube bundle was measured at a outer surface of a supporting structure through a transparent flow housing by the laser dopper vibrometer. Pressure drop in-between three measurement distances was measured by the differential pressure transmitter. High frequency vibration and pressure drop fairly depends on the geometric design of supporting structure. So, these two parameters would be used as a qualitative design variables for design evaluation and analysis.

  • PDF

이미지 처리기법 및 레이저 센서를 이용한 휴대용 콘크리트 균열 측정 장치 개발에 관한 연구 (A Study on Development of Portable Concrete Crack Measurement Device Using Image Processing Technique and Laser Sensors)

  • 서승환;온승엽;김동현;곽기석;정문경
    • 한국지반신소재학회논문집
    • /
    • 제19권4호
    • /
    • pp.41-50
    • /
    • 2020
  • 콘크리트 구조물의 균열은 장기간 지속 시 철근의 부식을 촉진시키므로 구조적 사용성을 보장하고 열화를 방지하기 위해 정기적인 현장 점검이 필수적이다. 대부분의 시설물 안전점검은 육안 검사에 의존하고 있어 비용과 시간 소모가 심하고 점검자에 따라 결과의 신뢰도 차이가 발생한다. 본 연구에서는 카메라로 촬영된 균열의 이미지 분석을 통해 콘크리트 균열의 폭과 길이를 측정하는 장치로서 안전진단 및 유지관리에 사용할 수 있는 휴대용 측정 장치를 개발하였다. 이 장치는 측정자가 육안으로 발견한 균열을 가까운 거리 (3m) 이내에서 촬영하고 레이저 거리측정으로 단위 픽셀크기를 정확히 산정하여, 본 연구에서 개발한 이미지 처리 알고리즘으로 균열 길이와 폭을 자동으로 산정할 수 있다. 측정결과 실험에 적용한 균열 이미지를 이용하여 3m 거리 이내에서 0.3mm 균열의 길이 측정은 약 10% 오차 범위에서 측정 가능하였다. 균열 폭의 경우 이진화 과정에서 진동 및 Blurring에 의한 주변픽셀을 검출해 과대평가되는 경향을 나타내었으나, 균열 폭 감소함수를 적용하여 효과적으로 보정할 수 있었다.

영상처리기법을 이용한 다중 변위응답 측정 알고리즘의 검증 (Verification of Multi-point Displacement Response Measurement Algorithm Using Image Processing Technique)

  • 김성완;김남식
    • 대한토목학회논문집
    • /
    • 제30권3A호
    • /
    • pp.297-307
    • /
    • 2010
  • 최근 토목, 건축 구조물의 유지관리 기술에 대한 관심이 커지고 있으며 구조물의 성능저하 및 노후화 등으로 구조적 안전성의 검토가 요구되는 구조물의 수가 급증하고 있는 실정이다. 그리고 구조물의 노후화 및 부재의 균열 등으로 인하여 강성이 저하되면 구조물의 동특성에 변화가 나타나게 되며 구조물의 실제 거동상태에서 동특성을 분석하여 손상부위와 손상정도를 정확히 판단하는 것은 중요한 문제이다. 구조물 모니터링에 사용되는 대표적 계측장비가 동적계측기이다. 기존의 동적계측기는 측정 센서와 장비를 연결하는 케이블 길이가 길어질 경우 신뢰할 수 있는 데이터를 얻기 힘들고 각 센서와 계측기를 1:1로 연결하는 방식을 취하고 있어 비경제적이다. 따라서 센서를 부착하지 않고 원거리에서 진동을 측정하는 방법이 필요하다. 구조물의 진동을 계측하기 위하여 적용 가능한 비접촉식 방법으로는 레이저의 도플러효과, GPS를 이용하는 방법 및 영상처리기법 등이 대표적이다. 레이저의 도플러효과를 이용하는 방법은 정확도가 상대적으로 높지만 비경제적이며, GPS를 이용하는 방법은 장비가 고가이고 신호 자체의 오차와 데이터 취득속도의 제약이 있는 단점이 있다. 그러나 영상신호를 이용하는 방법은 간편하고 경제적이며 접근이 어려운 구조물의 진동 및 동특성 추출에 적합하다. 기존에도 센서를 대신하여 카메라의 영상신호를 이용하는 연구가 수행되기도 하였으나, 기존의 방법은 구조물에 부착된 표적의 한 지점을 기록한 후 영상처리기법을 이용하여 진동을 측정하는 방법으로서 측정 대상이 비교적 국한적일 수 있다. 그러므로 본 연구에서는 영상처리기법을 이용하여 구조물의 다중 변위응답을 측정할 수 있는 방법의 타당성을 검증하기 위하여 진동대 실험 및 현장재하실험을 수행하였다.