• 제목/요약/키워드: Laser Ultrasound

검색결과 104건 처리시간 0.029초

Development of Nanostructured Light-Absorbers for Ultrasound Generation by Using a Solution-Based Process

  • Sang, Pil Gyu;Heo, Jeongmin;Song, Ju Ho;Thakur, Ujwal;Park, Hui Joon;Baac, Hyoung Won
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.377-377
    • /
    • 2016
  • Under nanosecond-pulsed laser irradiation, light-absorbing thin films have been used for photoacoustic transmitters for ultrasound generation. Especially, nanostructured absorbers are attractive due to high optical absorption and efficient thermoacoustic energy conversion: for example, 2-dimensional (2-D) gold nanostructure array, synthetic gold nanoparticles, carbon nanotubes (CNTs), and reduced graphene oxides. Among them, CNT has been used to fabricate a composite film with polydimethylsiloxane (PDMS) that exhibits excellent photoacoustic conversion performance for high-frequency, high-amplitude ultrasound generation. Previously, CNT-PDMS nanocomposite films were made by using a high-temperature chemical vapor deposition (HTCVD) process for CNT growth. However, this approach is not suitable to fabricate large-area CNT films (>several cm2). This is because a chamber dimension of HTCVD is limited and also the process often causes nonuniform CNT growth when the film area increases. As an alternative approach, a solution-based process can be used to overcome these issues. We develop PDMS composite transmitters, based on the solution process, using several nanostructured light-absorbers such as CNTs, nanoink powders, and imprinted regular arrays of gold nanostructure. We compare fabrication processes of each composite transmitters and photoacoustic output performance.

  • PDF

Granuloma Formation, a Rare Complication after PDO Threads Lifting, and Adjuvant Treatment Using Dual-Frequency Ultrasound (LDM®-MED)

  • Hong, Seok Won;Park, Eun Soo
    • Medical Lasers
    • /
    • 제8권1호
    • /
    • pp.35-38
    • /
    • 2019
  • Thread-lifting is a minimally invasive procedure that shows good results and fewer complications as compared with those results and complications of standard surgery. Many procedures and techniques have been developed to create a younger appearance of facial/neck skin for aging people, and the demand for an improved aesthetic appearance is increasing. Since the incidence of side effects is much less than that of non-absorbable threads, which can lead to complications such as foreign body reactions, polydioxanone (PDO) threads are predominantly used for face lift procedures. A 66-year-old woman presented to our clinic with inflamed palpable masses. She had undergone a face lift with absorbable threads in our clinic 5 months previously. Excisional biopsy was performed with the patient under local anesthesia. During the operation, any threads were not detected and there was both fibrotic scar tissue and granulomatous tissue. For effectively promoting healing and managing the scars, treatment with LDM®-MED was performed on the day after surgery. The treatment was performed according to the author's protocol. Although foreign body granuloma as a complication after using non-absorbable thread types have been previously reported, it is relatively rare to find this type of complication after using absorbable thread. In this report, we present a case in which a 66-year-old female with foreign body granuloma after undergoing a face lift using absorbable threads was treated with the application of dual-frequency ultrasound, which promoted wound healing.

레이저를 이용한 탄소섬유강화 복합재료의 비파괴평가 기법에 관한 연구 (A Study on Nondestructive Technique Using Laser Technique for Evaluation of Carbon fiber Reinforced Plastic)

  • 최상우;이준현;변준형;서경철
    • 비파괴검사학회지
    • /
    • 제25권2호
    • /
    • pp.103-109
    • /
    • 2005
  • 섬유강화복합재료의 품질향상을 위하여 제조공정중에 발생하게 되는 층간 분리 및 기공 등의 결함이 온라인상에서 검출되어야 한다. 일반적으로 섬유강화복합재료의 비파괴 평가에 있어서 초음파 평가기법이 널리 이용되고 있으나 기존의 초음파 평가 기법은 초음파 전파를 위하여 접촉이 이루어져야 하는 단점이 있다. 따라서 기존의 초음파 평가기법은 비접촉의 기법이 아니므로 제조공정중에 적용할 수 없다. 비접촉식의 초음파 평가 기법을 구현하기 위하여 광학적 기법의 레이저 기법이 적용되었으며 본 연구에서는 레이저 유도 초음파 발생 기법과 레이저 간섭계를 이용한 수신기법이 섬유강화 복합재료 판재에서 적용되었다. 레이저 유도 초음파는 펄스레이저에 의한 복합재료 표면의 순간적인 가열과 이에 의한 열변형으로 발생되어 전파되며 본 연구에 가속도계, AE센서 등 주파수 범위가 다른 수신센서를 이용하여 전파방향 변화에 따른 유도 초음파를 수신하였으며 수신된 유도초음파의 전파방향에 따른 전파속도를 비교하였다. 또한 비접촉 수신기법으로 레이저 간섭계를 이용하여 탄소섬유강화 복합재료에서의 초음파를 수신하고 그 주파수 특성을 분석하였다.

Development of rotational pulse-echo ultrasonic propagation imaging system capable of inspecting cylindrical specimens

  • Ahmed, Hasan;Lee, Young-Jun;Lee, Jung-Ryul
    • Smart Structures and Systems
    • /
    • 제26권5호
    • /
    • pp.657-666
    • /
    • 2020
  • A rotational pulse-echo ultrasonic propagation imager that can inspect cylindrical specimens for material nondestructive evaluations is proposed herein. In this system, a laser-generated ultrasonic bulk wave is used for inspection, which enables a clear visualization of subsurface defects with a precise reproduction of the damage shape and size. The ultrasonic waves are generated by a Q-switched laser that impinges on the outer surface of the specimen walls. The generated waves travel through the walls and their echo is detected by a Laser Doppler Vibrometer (LDV) at the same point. To obtain the optimal Signal-to-Noise Ratio (SNR) of the measured signal, the LDV requires the sensed surface to be at a right angle to the laser beam and at a predefined constant standoff distance from the laser head. For flat specimens, these constraints can be easily satisfied by performing a raster scan using a dual-axis linear stage. However, this arrangement cannot be used for cylindrical specimens owing to their curved nature. To inspect the cylindrical specimens, a circular scan technology is newly proposed for pulse-echo laser ultrasound. A rotational stage is coupled with a single-axis linear stage to inspect the desired area of the specimen. This system arrangement ensures that the standoff distance and beam incidence angle are maintained while the cylindrical specimen is being inspected. This enables the inspection of a curved specimen while maintaining the optimal SNR. The measurement result is displayed in parallel with the on-going inspection. The inspection data used in scanning are mapped from rotational coordinates to linear coordinates for visualization and post-processing of results. A graphical user interface software is implemented in C++ using a QT framework and controls all the individual blocks of the system and implements the necessary image processing, scan calculations, data acquisition, signal processing and result visualization.

배관부 부식 및 결함 평가를 위한 레이저 유도 초음파 적용 기술 (Application of Laser-based Ultrasonic Technique for Evaluation of Corrosion and Defects in Pipeline)

  • 최상우;이준현;조윤호
    • 비파괴검사학회지
    • /
    • 제25권2호
    • /
    • pp.95-102
    • /
    • 2005
  • 원자력 발전소의 많은 배관부는 고온, 고압환경에서 적용되고 있어 환경적 및 기계적 요인에 의하여 부식결함이 빈번히 발생하고 있다. 이와 같은 부식 결함은 초음파 기법 등에 의하여 평가되어야 하고, 본 연구에서는 주사형 레이저 유도 초음파(SLS) 기법을 도입하여 배관부 부식결함의 영상화 기법을 적용하였다. 본 기법은 표면이 거칠거나 배관재와 같은 곡면의 표면에서 적용할 수 있는 장점이 있다. 한편 기존의 주사형 초음파 기법은 초음파 센서와 검사대상체 사이의 초음파 전달 매개체를 확보하기 위하여 시험편이 수침되거나 워터젯을 이용하였으나 주사형 레이저 초음파 기법은 광학적 기법을 이용하여 초음파를 발생시키므로 비접촉 방법에 의한 주사 이미지 획득이 가능하다. 따라서 본 주사형 레이저 초음파 기법은 복잡한 구조물의 검사, 비접촉 원격 및 고화질의 결함 이미지 탐상이 가능하다. 본 연구에서는 배관 결함의 검출능 향상을 위하여 결함 영상 획득에 있어서 다양한 조건의 레이저 유도 초음파 발생 기법을 적용하였고, 배관에 존재하는 응력부식 균열의 결함 영상을 얻게 되었다.

Laser-assisted Delivery of a Combined Antioxidant Formulation Enhances the Clinical Efficacy of Fractional Microneedle Radiofrequency Treatment: A Pilot Study

  • Kim, Jihee;Kim, Soo Min;Jung, Bok Ki;Oh, Sang Ho;Kim, Young-Koo;Lee, Ju Hee
    • Medical Lasers
    • /
    • 제10권3호
    • /
    • pp.161-169
    • /
    • 2021
  • Background and Objectives Fractional microneedle radiofrequency systems are popular options to increase elasticity in aging skin. Laser-assisted drug delivery is a promising method for the epidermal injection of topically applied drugs and cosmetic ingredients. This study assesses the safety and efficacy of topical delivery of L-ascorbic acid, vitamin E, and ferulic acid after fractional microneedle radiofrequency treatment for reducing photodamage. Materials and Methods In this prospective, single-center, split-face, controlled pilot study, six women (mean age, 48.0 years; range, 35-57 years; Fitzpatrick skin types III and IV) exhibiting mild to moderate photodamage, underwent a single session of fractional microneedle radiofrequency treatment. The patients were instructed to apply the antioxidant formulation to only one side of the face. Patients were evaluated 3 days, 7 days, and 4 weeks thereafter, using three-dimensional imaging and ultrasound. Ex vivo, the full-thickness human skin was used for molecular and histological evaluation. Statistical analysis was achieved by applying t-tests, Mann-Whitney U tests, and one-way analyses of variance. Results Compared to the untreated side, the antioxidant-treated side exhibited a significant increase in dermal thickness (10.32% vs. 17.54%, p < 0.05), but not in skin elasticity (4.76% vs. 4.69%, p > 0.05). The difference in erythema between the sides was statistically not significant (p > 0.05). In the ex vivo model, expression of FGF2 in the skin was significantly increased after application of the antioxidant formulation, as compared to results obtained subsequent to fractional microneedle radiofrequency treatment only (p < 0.01). Conclusion This study demonstrates that for the treatment of photodamaged skin, laser-assisted delivery of the antioxidant formulation is a safe and effective adjuvant modality following fractional microneedle radiofrequency.

저강도 레이저와 초음파의 동시 적용이 골절 치유 촉진에 미치는 효과 (The Effects of Low-Intensity Ultrasound and Laser on Healing of Bone Fracture)

  • 이현기
    • The Journal of Korean Physical Therapy
    • /
    • 제15권4호
    • /
    • pp.331-372
    • /
    • 2003
  • The purpose of study was to evaluate effects of low-intensity ultrasound and laser on healing of bone fracture. Twenty fracture patient were selected for this study(fourteen males, six females. mean aged 44.8) fracture area was humerus, tibia, forearm bones. The obtain result are as follows. 1. The result of this study were following that pain score was significantly reduced pre intervention compared with post intervention in male(P<.001). 2. The result of this study were following that pain score was significantly reduced pre intervention compared with post intervention in female(P<.001). 1. The result of this study were following that pain score was not appeared reduced pre intervention compared with post intervention in male and female(P<.001). 4. The result of this study were following that pain score was not appeared pre intervention compared with post intervention in male between age(P<.001). 5. The result of this study were following that pain score was not appeared pre intervention compared with post intervention in female between age (P<.001). 6. The result of this study were following that radiologic score was significantly reduced pre intervention compared with post intervention in male(P<.001). 7. The result of this study were following that radiologic score was significantly reduced pre intervention compared with post intervention in female(P<.001). 8. The result of this study were following that radiologic score was not appeared reduced pre intervention compared with post intervention in male and female(P<.001). 9. The result of this study were following that radiologic score was not appeared pre intervention compared with post intervention in male between ages(P<.001). 10. The result of this study were following that radiologic score was not appeared pre intervention compared with post intervention in female between ages(P<.001). 11. The result of this study were following that healing on fracture area was observed that reduced pre intervention compared with post intervention

  • PDF

Effects of Ultrasound, Laser and Exercises on Temporomandibular Joint Pain and Trismus Following Head and Neck Cancer

  • Elgohary, Hany Mohamed;Eladl, Hadaya Mosaad;Soliman, Ashraf Hassan;Soliman, Elsadat Saad
    • Annals of Rehabilitation Medicine
    • /
    • 제42권6호
    • /
    • pp.846-853
    • /
    • 2018
  • Objective To compare the effects of low intensity ultrasound (LIUS), traditional exercise therapy (TET), low level laser therapy (LLLT) and TET on temporomandibular joint (TMJ) pain and trismus following recovery from head and neck cancer (HNC). Methods Sixty participants following, who had experienced HNC, were randomly allocated to three groups of 20 people each. Each group received different therapy. Group A received LIUS and TET; group B received LLLT and TET; while group C received TET. All 60 participants were evaluated under the visual analog scale (VAS), the University of Washington Quality of Life questionnaire (UW-QOL) and the Vernier caliper scale (VCS) at the beginning of the therapies and after 4 weeks. Results ANOVA test revealed significant improvements across all three groups with outcomes of p<0.05. The results of the UW-QOL questionnaire showed a significant difference between groups A, B and C in favor of group A (p<0.05). The VAS results showed a more improvement in group A as compared to group B (p<0.05), while there was no statistical difference between groups B and C (p>0.05). The VCS results showed more improvement for the individuals in group B as compared to those in group C (p<0.05), while there was minimal difference between groups A and B (p>0.05). Conclusion The LIUS and TET are more effective than LLLT and/or TET in reducing TMJ pain and trismus following HNC.

집속초음파 치료의 한의 임상 활용에 대한 고찰 (Clinical Application of Focused Ultrasound in Korean Medicine)

  • 최유민;이마음;허나연;이은희;최혁용;서형식;황의형;장인수
    • Korean Journal of Acupuncture
    • /
    • 제40권3호
    • /
    • pp.79-89
    • /
    • 2023
  • Objectives : The purpose of this study is to investigate various application methods of focused ultrasound and apply them to clinical use in Korean medicine. Methods : Search was performed using the search engines of electronic databases, including PubMed, ScienceDirect, Cumulative Index to Nursing and Allied Health Literature (CINAHL), ScienceON, Oriental Medicine Advanced Searching Integrated System (OASIS), China National Knowledge Infrastructure (CNKI), Wanfang Data, Japan Science Technology Information Aggregator, Electronic (J-STAGE) and Citation Information by NII (CiNii), from inception to July 2023 without language limitation. Inclusion criteria were clinical studies including randomized controlled trials (RCTs), and animal experimental studies related with focused ultrasound treatments for acupoints or meridian sinews. Results : Total 17 papers, 7 for RCT, 6 for in vivo animal studies, and other experimental studies, were finally selected. Indications used in studies were shoulder pain, back pain, chronic back pain, and degenerative knee arthritis. In experimental studies, studies on animal models of hypoxic ischemic brain damage and hyperlipidemia were also conducted. As for the acupoints, LR3, LI4, and ST36 were used in clinical studies and, in animal experimental studies, GV20, KI1, and ST36 were used. As for the dose, 4 studies below 3 W/cm2 and 3 studies in the range of 0.625 to 5 W/cm2 in clinical studies, and all studies did not exceed 5 W/cm2. In animal experimental studies, 0.5 W/cm2, 2 W/cm2, 7.5 WW/cm2, 15 W/cm2, 10~20 W/cm2 were used. In all three studies describing the penetration depth during irradiation, it was less than 1 cm. Conclusions : We suggest that focused ultrasound is an appropriate treatment tool for stimulating the acupoints to transfer heat energy. Future studies with rigorous and well-designed RCTs for various diseases will be required to ascertain the focused ultrasound stimulate acupoints or meridian sinews.

High-Intensity Focused Ultrasound: A Satisfactory, Non-invasive Procedure for Crow's Feet Wrinkles

  • Jung, Gyu Sik;Cho, In Kook;Sung, Hyung Min
    • Medical Lasers
    • /
    • 제8권2호
    • /
    • pp.59-63
    • /
    • 2019
  • Background and Objectives High-intensity focused ultrasound (HIFU) has been developed as an effective, non-invasive, skin-tightening method in response to the increasing demand for improvements in skin laxity and tightening with minimal risk and recovery time. This study evaluated the efficacy and safety of HIFU for non-invasive skin tightening of crow's feet wrinkles, with the aim of determining how long the tightening can be maintained. Materials and Methods Between January and March 2019, 21 female patients with crow's feet wrinkles were treated with HIFU. The treatment involved 200 shots, three times every 2 weeks. Three blinded, experienced plastic surgeons and patients evaluated satisfaction at 2 weeks after the first procedure, 2 weeks after the second procedure, 2 weeks after the third procedure, and 6 weeks after the first procedure based on photographs according to the Global Aesthetic Improvement Scale (GAIS). The Friedman test was used to compare data. Results Of the 21 patients treated using HIFU, one was lost to follow-up for nonstudy-related reasons. Therefore, 20 patients were evaluated and ranged in age from 28 to 48 years. Plastic surgeons' GAIS scores were 2.6, 2.3, 1.7, and 1.3 and patients' GAIS scores were 2.6, 2.2, 1.8, and 1.4 at 2 weeks after the first procedure, 2 weeks after the second procedure, 2 weeks after the third procedure, and 6 weeks after the third procedure. No serious adverse effects were observed. Conclusion The aging face with crow's feet wrinkles can be improved by using HIFU, while minimizing epidermal and dermal injury.