• 제목/요약/키워드: Laser Scattering

검색결과 408건 처리시간 0.032초

무질서한 매질에서 침투깊이와 파동 전파 (Penetration depth and Wave Propagation in Random Media)

  • 김기준;성기천
    • 한국응용과학기술학회지
    • /
    • 제23권1호
    • /
    • pp.70-76
    • /
    • 2006
  • The influence of fluorophor, scatterer, absorber in turbid materials by light scattering were interpreted for the scattered fluorescence intensity and wavelength, it is studied the molecular property by laser induced fluorescence spectroscopy. It can be found that the effects of optical property are penentrated in scattering media by the optical $parameters({\mu}s$, ${\mu}a$, ${\mu}t$, ${\gamma}$, ${\rho})$. The value of scattering coefficient ${\mu}s$ is large appeared by means of the increasing particles of scattering, it can be found that the slope appears exponentially as a function of distance from laser source to detector. It may also utilize in designing the best model for oil chemistry, laser medicine and application of medical engineering.

형광, 산란광 동시 촬열법을 이용한 가솔린 분무의 거동에 관한 연구 (Visualization of Gasoline Sprays Via a Simultaneous Inaging of Fluorescence and Scattering Lights)

  • 원영호
    • 한국자동차공학회논문집
    • /
    • 제5권6호
    • /
    • pp.167-174
    • /
    • 1997
  • The penetration depth and the size distribution of the droplets of fuel sprays are important in the operation of spark-ignition MPI engines. A fluorescence/scattering image technique for droplet sizing was applied to measure th edroplet size distribution in non-evaporating gasoline sprays. The fluorescence and scattering lights were imaged simultaneously by the two-dimensional visualization system composed of a laser sheet, a doubling prism, optical filters, and a CCD camera. Quantitative droplet size distributions were extracted from evaluating the ratio of the two light densities. The mean droplet size measured by the fluorescence/scattering technique was compared with the result obtained by the enlarged photographs of droplets. The fluorescence/scattering image technique also gives the useful information of the characteristics of droplet impingement in a inclined wall.

  • PDF

Laser Raman Scattering을 이용한 가스 분무내 당량비 계측에 관한 연구 (Equivalence Ratio Measurements in Gas Spray Using Laser Raman Scattering)

  • 진성호;박경석;송재익;김경수
    • 한국분무공학회지
    • /
    • 제2권4호
    • /
    • pp.7-14
    • /
    • 1997
  • Laser Raman scattering method has been applied to measure equivalence ratio of methane/air mixture in injected spray. We used high power KrF excimer laser$(\lambda=248nm)$ and a high gain ICCD camera to capture low intensity signal. Raman shifts and Raman scattering cross -sections of $H_2,\;O_2,\;N_2,\;CO_2,\;CH_4\;and\;C_3H_8$ are measured precisely. Our results show an excellent agreement with those of other groups. Mole fraction measurement of $O_2\;and\;N_2$ from air shows that $O_2:N_2=0.206:0.794$. We used gas injector which was operated at 1 bar. Methane is used as a fuel. Spray region is $10mm\times37mm$ and this region is divided into 80 points. In Raman signals are obtained and ensemble averaged for each point. 3-d and contour plot of distribution of equuivalence ratio is presented. Our measured results show that the equivalence ratio of methane/air mixture in methane-rich region is reasonable. However, more study is necessary for methane-lean region because background noise level is almost same as Raman intensity of methane.

  • PDF

입자 이동 방식에서 Laser Induced Fluorescence와 뭉침에 관한 연구 (A Study on Laser Induced Fluorescence and Coagulation in Particle Transport Mode)

  • 김기준
    • 한국응용과학기술학회지
    • /
    • 제23권4호
    • /
    • pp.340-346
    • /
    • 2006
  • The influences of fluorescence, scattering, and flocculation in turbid material by light scattering were interpreted for the scattered fluorescence intensity and wavelength, it has been studied the molecular properties by the spectroscopy of laser induced fluorescence (LIF). The effects of optical properties in scattering media have been found by the optical $parameters({\mu}_s,\;{\mu}_a,\;{\mu}_t)$. Flocculation is an important step in many solid-liquid separation processes and is widely used. When two particles approach each other, interactions of several colloid particles can come into play which may have major effect on the flocculation and LIF process, The value of scattering coefficient ${\mu}_s$ is large by means of the increasing particles of scatterer it has been found that the slope decays exponentially as a function of distance from laser source to detector. It may also aid in designing the best model for oil chemistry, biopharmaceutical products, laser medicine and application of medical engineering on LIF and coagulation in particle transport mode.

Impact of the Spectral Linewidth of a Pseudorandom Binary Sequence (PRBS)-Modulated Laser on Stimulated Brillouin Scattering and Beam Quality

  • Aeri Jung;Sanggwon Song;Kwang Hyun Lee;Jung Hwan Lee;Kyunghwan Oh
    • Current Optics and Photonics
    • /
    • 제7권6호
    • /
    • pp.665-672
    • /
    • 2023
  • This study focuses on investigating the impact of the spectral linewidth of a seed laser in a master-oscillator power amplifier (MOPA) configuration on stimulated Brillouin scattering and the beam quality of the output diffracted by a grating. To conduct the study, a distributed feedback (DFB) laser is modulated in a pseudorandom binary sequence (PRBS) and amplified by a two-stage Yb-doped fiber amplifier to achieve an output power of over 1 kW. The spectral linewidth of the seed laser is systematically varied from 1 to 12 GHz in the frequency domain by varying the PRBS modulation parameters. The experimental results reveal a tradeoff between suppressing stimulated Brillouin scattering and enhancing beam quality with increased spectral linewidth. Therefore, the study provides valuable insights into optimizing spectral beam combining to achieve high beam quality and scalable power upgrade in fiber lasers.

2개의 레이저 파장에 따른 마우스 호중구의 산란광 비교 연구 (Comparison of Scattered Light of ex vivo Mouse Neutrophils by Different Wavelength Laser Irradiation)

  • 박재성;손민지;황창순;이호
    • 한국산업융합학회 논문집
    • /
    • 제25권3호
    • /
    • pp.365-378
    • /
    • 2022
  • Complete blood cell count(CBC) is a technique that counts leukocytes for each type of blood cell being analyzed. The principle is that laser is incident to ex vivo flowing leukocytes in a microcapillary tube and scattered light occurs by laser and leukocytes. By collecting the scattered light, we can count the types of cells because different cells generate different light-scattering patterns. However, the technique has an intrinsic limitation, scattering pattern is shown in a wide range region in the resulting, which makes it difficult to accurate analyze and use fluorescent dyes. To overcome this limitation, a new design of CBC with a dual laser, which irradiates with orthogonal angles for collecting quad-scattering information was proposed. Before development, the scattering difference depending on wavelength must be investigated to only catch up to the scattered signal by angles. Some studies, which focused on simple particles, have been conducted to theoretically and experimentally investigate different scatterings by wavelength. In this study, we propose an optical system for measuring scattered light and investigate a complex particle. As a result, the green laser made strong scattering signals in both the forward and side direction: 10% and 30%, respectively.

레이저 레일레이 산란법에 의한 定積燃燒室內의 溫度變動에 대한 計測 (The Measurement of the Temperature Variation in a Constant Volume Combustion Chamber by the Laser Rayleigh Scattering)

  • 김춘중;김중엽
    • 대한기계학회논문집
    • /
    • 제15권1호
    • /
    • pp.328-340
    • /
    • 1991
  • 본 연구에서는 혼합기를 연소실 내로 공급하기 전에 필터를 이용하여 일정 크 기의 미립자를 제거함으로서 가능한 Mie산란의 영향을 감소시키고, 또 화학 발광의 영 향을 제거하기 위하여 광학장치의 개선 및 광학 필터를 사용하였다. 뿐만 아니라 연 소실 내의 배경광 및 반사산란광을 제거하기 위한 방법으로 입사창 및 연소실 내를 모 두 코팅을 하였다. 따라서 레이저 레일레이 산란을 이용하여 지금까지 나타난 문제 점들을 위와 같은 방법으로 개선하였을 뿐만 아니라 측정기술을 향상시켜 정적연소실 내에서의 온도를 측정함으로서 정적연소실 내에서의 온도측정이 가능하다는 것을 확인 하고, 또 그 적응성을 조사하는데 중점을 두어 실험을 하였다.

Helicon Discharge Plasma Source and Laser Thomson Scattering System in KRISS

  • 서병훈;유신재;김정형;성대진;장홍영
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.149-149
    • /
    • 2012
  • We introduce Helicon discharge plasma source and Laser Thomson scattering system recently finished an installation in KRISS. Laser Thomson scattering method is promising for diagnostics in Helicon plasma because a measurement by electrical probe typically used has significant errors due to the gyromotion of electrons induced by high magnetic field. However, we found that LTS is affected by magnetic field so that we applied the normalization method for processing data and the results show a clear Maxwellian distribution at various conditions of magnetic field and RF power at low energy part without distortion.

  • PDF

Minimum Sensing Angular Velocity Improvement of Ring Laser Gyro Using a Low-Scattering Mirror

  • Jo, Min-Sik;Shim, Kyu-Min;Kim, Hoe-Young;Cho, Hyun-Ju;Jun, Gab-Song;Son, Seong-Hyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.56.2-56
    • /
    • 2001
  • For the improvement of minimum sensing angular velocity of ring laser gyro, the influence of a low-scattering mirror application to laser resonator was investigated. Super polishing technique was employed for the fine mirror substrates of less than 1-${\AA}$-rms roughness. Mirror coating using ion-beam sputtering coating machine produced low-scattering mirror less than 30-ppm scattering. As a result of the mirror application to ring laser, the minimum sensing angular velocity of the gyro was improved down to about 0.1 deg/sec.

  • PDF

Laser Thomson Scattering for Measuring Plasma Temperature and Density in ICP

  • 서병훈;유신재;김정형;장홍영
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제41회 하계 정기 학술대회 초록집
    • /
    • pp.144-144
    • /
    • 2011
  • Diagnostics of plasma density and temperature play an important role for monitoring plasma processing and Laser Thomson scattering is a one of the most accurate diagnostic technique for measuring plasma density and temperature because of none-perturbation to plasma among various diagnostic techniques invented to measure plasma density and temperature. I will briefly review Laser Thomson scattering experiment performed in KRISS and difficulties for measuring the electron velocity distribution such as Gaussian due to low signal-to-noise ratio with showing results that we got until now. This work is an intermediate step in a process that we will get a reliable data which shows physical phenomenon of plasma compared with other diagnostic techniques and results.

  • PDF