• Title/Summary/Keyword: Laser Scanning

Search Result 1,398, Processing Time 0.025 seconds

A Study on the Reverse Engineering and Wear Analysis for Remanufacturing Planner Miller (플래너 밀러 재제조를 위한 역설계 및 마모 분석에 관한 연구)

  • Choi, Doo-Han;Kong, Seok-Hwan;Byeon, Jeong-Won;Kim, Tae-Woo;Hong, Dae-Sun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.6_2
    • /
    • pp.1103-1110
    • /
    • 2022
  • The old machine tools that have been used for a long time cause both increase in defective rate and decrease in productivity compared to new machines due to wear and failure of their components. In order to improve productivity and quality of machined components through remanufacturing, it is necessary to analyze the wear and failure of major components of old machine tools. In this study, the process for reverse engineering is designed for the remanufacture of planner millers, which belong to a very large machine tool. Also, the suitability of the designed process is verified through the analysis of the selected remanufactured components. In the first step of the process, some major components of the aging planner miller are scanned using a 3D laser scanner. In the next step, reverse engineering is performed using the data obtained through 3D scanning. Finally, wear and failure analysis is performed by comparing the reverse engineering data with the scan data. As a result, this reverse design and wear analysis can complement the insufficient design database and reduce costs in the maintenance of remanufactured products.

Antagonistic Potentiality of Actinomycete-Derived Extract with Anti-Biofilm, Antioxidant, and Cytotoxic Capabilities as a Natural Combating Strategy for Multidrug-Resistant ESKAPE Pathogens

  • Mohamed H. El-Sayed;Fahdah A. Alshammari;Mohammed H. Sharaf
    • Journal of Microbiology and Biotechnology
    • /
    • v.33 no.1
    • /
    • pp.61-74
    • /
    • 2023
  • The global increase in multidrug-resistant (MDR) bacteria has inspired researchers to develop new strategies to overcome this problem. In this study, 23 morphologically different, soil-isolated actinomycete cultures were screened for their antibacterial ability against MDR isolates of ESKAPE pathogens. Among them, isolate BOGE18 exhibited a broad antibacterial spectrum, so it was selected and identified based on cultural, morphological, physiological, and biochemical characteristics. Chemotaxonomic analysis was also performed together with nucleotide sequencing of the 16S rRNA gene, which showed this strain to have identity with Streptomyces lienomycini. The ethyl acetate extract of the cell-free filtrate (CFF) of strain BOGE18 was evaluated for its antibacterial spectrum, and the minimum inhibitory concentration (MIC) ranged from 62.5 to 250 ㎍/ml. The recorded results from the in vitro anti-biofilm microtiter assay and confocal laser scanning microscopy (CLSM) of sub-MIC concentrations revealed a significant reduction in biofilm formation in a concentration-dependent manner. The extract also displayed significant scavenging activity, reaching 91.61 ± 4.1% and 85.06 ± 3.14% of 2,2-diphenyl-1-picrylhydrazyl (DPPH) and 2,2'-azinobis(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS), respectively. A promising cytotoxic ability against breast (MCF-7) and hepatocellular (HePG2) cancer cell lines was obtained from the extract with IC50 values of 47.15 ± 13.10 and 122.69 ± 9.12 ㎍/ml, respectively. Moreover, based on gas chromatography-mass spectrometry (GC-MS) analysis, nine known compounds were detected in the BOGE18 extract, suggesting their contribution to the multitude of biological activities recorded in this study. Overall, Streptomyces lienomycini BOGE18-derived extract is a good candidate for use in a natural combating strategy to prevent bacterial infection, especially by MDR pathogens.

Quantitative Analysis of 3D Printing Layered Shape according to the Flatness of Construction Surface (시공표면평탄에 따른 3D 프린팅 적층형상 정량분석)

  • Park, Jin Su;Kim, Kyung Taek
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.2
    • /
    • pp.257-261
    • /
    • 2022
  • Additive manufacturing (AM, also known as 3D printing) applied to the construction industry is implemented and verified for various effects since advantages such as high design freedom, improving worker safety, and predictable construction period. However, due to the low maturity compared to the existing technology, studies are underway to solve new problems that occur in the overall of AM technology. In this paper, we confirm the effect of low construction surface flatness on the stacked features in the process of on-site AM construction. In particular, unstable AM features are determined through quantitative analysis by laser scanning, and a construction strategy is proposed for the surface flattening.

Changes in the composition of artificial cariogenic biofilms over time (인공 우식 유발성 biofilm 구성성분의 시간 흐름에 따른 변화)

  • Oh, Chul;Pandit, Santosh;Jeon, Jae-Gyu
    • Journal of Korean Academy of Oral Health
    • /
    • v.43 no.3
    • /
    • pp.118-123
    • /
    • 2019
  • Objectives: The purpose of this study was to investigate changes in the composition of artificial cariogenic biofilms using a Streptococcus mutans biofilm model over a period of time. Methods: We analyzed the dry weight, colony forming unit (CFU) number, extracellular polysaccharide (EPS) biovolume, and acid production rate of S. mutans biofilms formed on saliva-coated hydroxyapatite discs after 26 h, 50 h, 74 h, 98 h, 171 h, and 195 h. In addition, we performed a laser scanning confocal fluorescence microscopy to determine the bacterial volume, EPS biovolume, and biofilm thickness. We calculated the biofilm density using dry weight and EPS biovolume. Results: Over a period of time, there was no change in the CFU number and acid production rate of S. mutans biofilms, but there was an increase in the dry weight and EPS biovolume of S. mutans biofilms. The bacterial volume, EPS biovolume, and biofilm thickness only increased in the 50-h-old biofilm; however, no change was observed in 50-195-h-old biofilms. In addition, an increase in the biofilm density was observed over time. Conclusions: These results suggest that the acid production ability of cariogenic biofilms does not change, but the biofilm density increases over time. However, due to scientific information, further research needs to be conducted in the field of dentistry to get further insights on the progression of cariogenic biofilms over time.

Bonding effects of cleaning protocols and time-point of acid etching on dentin impregnated with endodontic sealer

  • Tatiane Miranda Manzoli;Joissi Ferrari Zaniboni;Joao Felipe Besegato;Flavia Angelica Guiotti;Andrea Abi Rached Dantas;Milton Carlos Kuga
    • Restorative Dentistry and Endodontics
    • /
    • v.47 no.2
    • /
    • pp.21.1-21.11
    • /
    • 2022
  • Objectives: This study aimed to investigate the bonding effects of cleaning protocols on dentin impregnated with endodontic sealer residues using ethanol (E) or xylol (X). The effects of dentin acid etching immediately (I) or 7 days (P) after cleaning were also evaluated. For bonding to dentin, universal adhesive (Scotchbond Universal; 3M ESPE) was used. The persistence of sealer residues, hybrid layer formation and microshear bond strength were the performed analysis. Materials and Methods: One hundred and twenty bovine dentin specimens were allocated into 4 groups (n = 10): G1 (E+I); G2 (X+I); G3 (E+P); and G4 (X+P). The persistence of sealer residues was evaluated by SEM. Confocal laser scanning microscopy images were taken to measure the formed hybrid layer using the Image J program. For microshear bond strength, 4 resin composite cylinders were placed over the dentin after the cleaning protocols. ANOVA followed by Tukey test and Kruskal-Wallis followed by Dunn test were used for parametric and non-parametric data, respectively (α = 5%). Results: G2 and G4 groups showed a lower persistence of residues (p < 0.05) and thicker hybrid layer than the other groups (p < 0.05). No bond strength differences among all groups were observed (p > 0.05). Conclusions: Dentin cleaning using xylol, regardless of the time-point of acid etching, provided lower persistence of residues over the surface and thicker hybrid layer. However, the bond strength of the universal adhesive system in etch-and-rinse strategy was not influenced by the cleaning protocols or time-point of acid etching.

Development of Hair Keratin Protein to Accelerate Oral Mucosal Regeneration

  • So-Yeon Kim
    • Journal of dental hygiene science
    • /
    • v.23 no.4
    • /
    • pp.369-377
    • /
    • 2023
  • Background: In this study, we investigated the potential use of keratin for oral tissue regeneration. Keratin is well-known for its effectiveness in skin regeneration by promoting keratinization and enhancing the elasticity and activity of fibroblasts. Because of its structural stability, high storability, biocompatibility, and safety in humans, existing research has predominantly focused on its role in skin wound healing. Herein, we propose using keratin proteins as biocompatible materials for dental applications. Methods: To assess the suitability of alpha-keratin protein as a substrate for cell culture, keratin was extracted from human hair via PEGylation. Viabilities of primary human gingival fibroblasts (HGFs) and human oral keratinocytes (HOKs) were assessed. Fluorescence immunostaining and migration assays were conducted using a fluorescence microscope and confocal laser scanning microscope. Wound healing and migration assays were performed using automated software to analyze the experimental readout and gap closure rate. Results: We confirmed the extraction of alpha-keratin and formation of the PEG-g-keratin complex. Treatment of HGFs with keratin protein at a concentration of 5 mg/ml promoted proliferation and maintained cell viability in the test group compared to the control group. HOKs treated with 5 mg/ml keratin exhibited a slight decrease in cell proliferation and activity after 48 hours compared to the untreated group, followed by an increase after 72 hours. Wound healing and migration assays revealed rapid closure of the area covered by HOKs over time following keratin treatment. Additionally, HOKs exhibited changes in cell morphology and increased the expression of the mesenchymal marker vimentin. Conclusion: Our study demonstrated the potential of hair keratin for soft tissue regeneration, with potential future applications in clinical settings for wound healing.

Characterization of Oleogels and Oleogel Emulsions Made with Sucrose Ester and Ceramide as Mixed Gelators (수크로스 에스터와 세라마이드를 혼합 겔레이터로 사용한 올레오겔과 올레오겔 에멀젼의 특성 분석)

  • Dayeon Lee;Byung Suk Jin
    • Applied Chemistry for Engineering
    • /
    • v.34 no.5
    • /
    • pp.501-506
    • /
    • 2023
  • Oleogel and oleogel emulsions of sunflower oil were prepared using sucrose ester and ceramide as mixed gelators. The crystal structure of the gelator in the oleogels and oleogel emulsion formulations was observed with a polarized optical microscope, and the dispersion form of water was confirmed with confocal laser scanning microscopy. Through the DSC thermogram analysis, it was confirmed that the crystal structure of ceramide disappeared when sucrose ester and ceramide were mixed, and the crystallinity of the mixed gelator increased further when water was added to the formulation. Changes in rheological properties such as viscosity and viscoelasticity according to the ratio of sucrose ester, ceramide, and water in the formulation were examined. As the content of ceramide and water increased, the viscosity, storage modulus, and loss modulus all increased, and the stability of the formulation also tended to increase.

A Study on the labial & buccal surface contour in Korean permanent teeth using three-dimensional laser scanning (3차원 레이저 스캐너를 이용한 한국인 영구치의 순, 협측 치관 굴곡도에 관한 연구)

  • Ko, Sang-Duck;Cha, Kyung-Suk
    • The korean journal of orthodontics
    • /
    • v.32 no.4 s.93
    • /
    • pp.275-291
    • /
    • 2002
  • Of various factors indicated for effective use of straight wire appliances, there was a great lack of studies both domestic and international about the curvatures of tooth crowns. This study was performed to investigate the labio/buccal clinical crown curvatures of Korean permanent teeth. For this study, three-dimensional laser scanning was performed on 36 dental casts with normal anatomic structures. Andrews plane and Facial axis of clinical crown (FACC) were designated as horizontal and vertical reference planes respectively. 2 or 3 lines, 1mm apart, were drawn superior, inferior, left and right of these reference planes. A three-dimensional coordinate table was made for points formed by crossing these lines, and averages of each coordinate point on the 36 dental casts were obtained. The curvature equation was made using three-dimensional coordinate points (x,y,z) and by this curvature equation, the curve ratio of each tooth was obtained. Curve ratio changes of each section of teeth were calculated by curve ratios of simplified curves. These two dimensional curves were simplified horizontally and vertically Conclusions for this study are as follows. 1. The basic data of labial and buccal clinical crown curvatures were obtained about Korean permanent teeth. 2. No significant difference was found between male and females. 3. Individual tooth characteristics 1) In maxillary central incisors, the difference in the curve ratio between the gingival and incisal sides was greater than for the other teeth. And the gingival side showed a greater curve ratio. 2) Maxillary canines showed more curvatures in the mesio-occlusal surface than the other surfaces. 3) In maxillary $1^{st}$ premolars, more curvatures were found in mesio-occlusal and disto-gingival surface, thus showing a twisted crown surface, but in maxillary $2^{nd}$ premolars, the crown curvatures of mesial and distal ends became parallel to each other. 4) No significant difference in crown curvatures was found between mandibular central and lateral incisors. 5) Occluso-gingival curvatures of mandibular$2^{nd}$ premolar turned out to be more rounded than mandibular $1^{st}$ premolars or maxillary $2^{nd}$ premolars. From the above conclusions, it can be deduced that the same bracket bases can be used for mandibular central and lateral incisors. But for maxillary $1^{st}\;and\;2^{nd}$ premolars and for mandibular $1^{st}\;and\;2^{nd}$ premolars, because crown curvatures showed significant differences, when making bracket bases there is ample reason to make bracket base curves differently for each type of tooth.

An experimental study of cutting efficiency of air-driven diamond burs on human tooth (수종 air-turbine 다이아몬드 버의 절삭 효과에 관한 실험적 연구)

  • Hong, Jin-Sun;Yeo, In-Sung;Kim, Sung-Hun;Lee, Jai-Bong;Han, Jung-Suk;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.1
    • /
    • pp.1-7
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate the cutting efficiency of coarse grit diamond burs with air-turbine handpiece on natural tooth. Materials and methods: Four groups of coarse grit diamond bur were selected: Komet (A), Shofu (B), Premier (C), and Mani (D). The extracted maxillary central incisors were used, and ten cuts were made on each specimen, using the rotary diamond burs. The surface of each bur was measured at the upper, middle, and bottom of the bur with confocal laser scanning microscope and imaged with SEM. The data were analyzed with one-way ANOVA and t-test at the significance level of 0.05. Results: The surface roughness was measured. At the A diamond bur, the Sa values were $52.93\;{\mu}m$, $48.32\;{\mu}m$, $46.79\;{\mu}m$, $45.06\;{\mu}m$, and $43.43\;{\mu}m$ for control, test 1, 2, 3, and 4 respectively. The Sa values were $50.68\;{\mu}m$, $45.62\;{\mu}m$, $44.41\;{\mu}m$, $44.10\;{\mu}m$, and $42.46\;{\mu}m$ for B diamond bur, $58.02\;{\mu}m$, $55.53\;{\mu}m$, $52.22\;{\mu}m$, $48.26\;{\mu}m$, and $45.36\;{\mu}m$ for C diamond bur, and $50.11\;{\mu}m$, $46.73\;{\mu}m$, $45.46\;{\mu}m$, $42.58\;{\mu}m$, and $41.80\;{\mu}m$ for D diamond bur. Surface roughness after each bur use showed significant changes, but no significant difference was found in surface roughness change between bur systems. Conclusions: Surface roughness in the same bur system showed significant differences after each tooth preparation. However no statistically significant differences were found in surface roughness between bur systems. The SEM images between control and test 4 showed the abraded particles.

CHANGE OF VASOACTIVE INTESTINAL POLYPEPTIDE(VIP) IMMUNOREACTIVE CELLS FOLLOWING PULP EXTIRPATION IN RAT TRIGEMINAL GANGLION: A CONFOCAL LASER SCANNING MICROSCOPIC STUDY (치수제거 후 흰쥐 삼차신경절에서 VIP 면역반응세포의 변화: 공초점레이저주사현미경적 연구)

  • Kim, Heung-Joong;Kim, Seung-Jae;Park, Joo-Cheol;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.1
    • /
    • pp.25-31
    • /
    • 2001
  • The purpose of this study was to investigate the distribution and fluorescence intensity of vasoactive intestinal polypeptide immunoreactive (VIP-IR) cells in rat trigeminal ganglion following pulp extirpation of rat mandibular molar. The animals were divided into control group(n=6) and experimental group(n=6). The experimental animals were sacrificed at 14 days after pulp extirpation. The trigeminal ganglion was removed and immersed in the 4% paraformaldehyde in 0.1M phosphate buffer. Serial frozen sections about $20{\mu}m$ in thickness were cut with a cryostat. The immunofluorescence staining was performed. The rabbit anti-VIP(1 : 8,000) was used as primary antibody and fluorescene isothiocynate(FITC) conjugated anti-rabbit IgG(1 : 80) as secondary antibody. The slides were observed under confocal laser scanning microscope (CLSM). Unprocessed optical sections were obtained and stored on a optical disk. Color pictures were printed by a video copy processor. The results were as follows; 1. The positive ratio of VIP-IR cells in mandibular part of trigeminal ganglion were 7.40% in control group and 28.42% in experimental group(14 days after pulp extirpation). 2. The relative fluorescence intensity of VIP-IR cells in mandibular part of trigeminal ganglion were 87.78 in control group and 138.65 in experimental group. The relative fluorescence intensity of experimental group was 58% higher than that of control group. 3. In optical serial section analysis of VIP-IR cells of experimental group, most of the 9 sections showed high fluorescence intensity. At high magnification, axons of the experimental group displayed greater VIP-IR than in the control group, and the positive cells were mainly of medium size. The result indicate that number and fluorescence intensity of VIP-IR cells were increased in the mandibular part of trigeminal ganglion following pulp extirpation of mandibular molar, and it suggests that VIP could play a role in processing of nociception.

  • PDF