• 제목/요약/키워드: Laser Calibration

검색결과 251건 처리시간 0.038초

레이저 비전 기술을 이용한 물체의 3D 모델 재구성 방법에 관한 연구 (A Study on Three-Dimensional Model Reconstruction Based on Laser-Vision Technology)

  • 응후쿠옹;이병룡
    • 한국정밀공학회지
    • /
    • 제32권7호
    • /
    • pp.633-641
    • /
    • 2015
  • In this study, we proposed a three-dimensional (3D) scanning system based on laser-vision technique and rotary mechanism for automatic 3D model reconstruction. The proposed scanning system consists of a laser projector, a camera, and a turntable. For laser-camera calibration a new and simple method was proposed. 3D point cloud data of the surface of scanned object was fully collected by integrating extracted laser profiles, which were extracted from laser stripe images, corresponding to rotary angles of the rotary mechanism. The obscured laser profile problem was also solved by adding an addition camera at another viewpoint. From collected 3D point cloud data, the 3D model of the scanned object was reconstructed based on facet-representation. The reconstructed 3D models showed effectiveness and the applicability of the proposed 3D scanning system to 3D model-based applications.

동축류 버너에서 생성된 부분 예혼합 화염을 이용한 화염 온도 측정 검정원 연구 (Study on the Partially Premixed Flames Produced by a Coflow Burner as Temperature Calibration Source)

  • 박철웅;한재원;신현동
    • 한국연소학회지
    • /
    • 제5권1호
    • /
    • pp.91-98
    • /
    • 2000
  • We investigated a uniform temperature zone, produced by double flame structure of a co flow CH4/air partially premixed flame, to be used as a temperature calibration source for laser diagnostics. A broadband N2 CARS(coherent anti-Stokes Raman spectroscopy) system with a modeless laser was used for temperature measurement. When the stoichiometric ratio was 1.5, we found the uniform temperature zone in radial direction of the flame of which the averaged temperature was 2110 K with standard deviation 24 K. In the stoichiometric ratio range between 2.0 and 2.5, we found very stable temperature-varying zones in vertical direction at the center of the flame. The size of the zone was approximately 15 mm and it covered a temperature range from 300 K to 1900 K. We also suggest that this zone can be used as a calibration source for 2-D PLIF(planar laser induced flurescence) temperature measurement.

  • PDF

레이저-수광소자를 이용한 선형 이송측의 기하학적 오차측정 시스템 (Geometric error assessment system for linear guideway using laser-photodiodes)

  • 박희재;주종남;황상욱
    • 한국정밀공학회지
    • /
    • 제11권5호
    • /
    • pp.180-188
    • /
    • 1994
  • Error assessment and evaluation for machine for machine tool slides have been considered as essential tools for improving accuracy. In this paper, a computer aided measurement technique is proposed using photo pin diodes of quadrant type and laser source. In thedeveloped system, three photo diodes are mounted on a sensor mounting table, and the sensored signal is processed by specially designed signal conditioner to give fine resolution with minimum noise. A micro computer inputs the processed signal, and the geometric errors of five degree of freedoms are successfully evaluated. Pitch, roll, yaw, vertical and horizontal straightness errors are thus assessed simultaneously for a machine tool slide. Calibration techniques such as optics calibration, photo diode calibration are proposed and implemented, giving precise calibration for the measurement system. The developed system has been applied to a practical machine tool slide, and has been found as one of efficient and precise technique for machine tool slide.

  • PDF

레이저 간섭계를 이용한 진동 가속도계 절대교정 시스템 자동화 (Automation of Primary Vibration Calibration System Using Laser Interferometer)

  • 조승일;이용봉;전병수;이종규;이두희
    • 한국소음진동공학회논문집
    • /
    • 제15권11호
    • /
    • pp.1241-1247
    • /
    • 2005
  • An automation of primary vibration calibration system was developed and tested. Using GPIB interface, the console PC make the control of equipments, signal collecting and save measuring results automatically by the instructions in the program by Visual Basic. Several trials of automatic calibration for the accelerometer(ENDEVCO 2270) using this developed system give the reliable results.

연속파 Nd:YAG 레이저를 이용한 치아교정 급속 구개확장장치 용접특성 (Welding Characteristics of Rapid Palatal Expander for Teeth Calibration using a Continuous Wave Nd:YAG Laser)

  • 유영태;양윤석;신호준
    • 한국정밀공학회지
    • /
    • 제27권2호
    • /
    • pp.40-49
    • /
    • 2010
  • The Purpose of this paper is to weld a rapid palatal expander using a continuous wave Nd:YAG laser. The rapid palatal expander has become a useful treatment method for severe maxillary transverse deficiencies and posterior crossbites. Rapid maxillary expansion is a well-established method to correct transverse maxillary deficiency and arch length discrepancy. The major process parameters studied in the present laser welding experiment were the positions of focus, laser power and travel speed of laser beam. We measured the fusion zone size and its shape using an optical microscope for the observation of cross-sectional area and tension stress of a rapid palatal expander welded. Through the experimental investigation, the optimum speeds and power of laser without deficiencies of weld cross-sectional area were obtained.

무인잠수정을 위한 효과적이고 유연한 설치 성능을 지닌 수중 레이저스캐너 개발 (Development of Underwater Laser Scanner with Efficient and Flexible Installation for Unmanned Underwater Vehicle)

  • 이영준;이윤건;채준보;최현택;여태경
    • 한국해양공학회지
    • /
    • 제32권6호
    • /
    • pp.511-517
    • /
    • 2018
  • This paper proposes a vision-based underwater laser scanner with separate structures for an underwater camera and a line laser projector. Because the two devices can be adaptively placed regardless of the features of the unmanned underwater vehicle (UUV), the scanner has significant advantages in relation to its availability and flexibility. Position calibration between the underwater camera and laser projector guarantees a 3D measuring performance with high accuracy. To verify the proposed underwater laser scanner, a test-bed system was manufactured, which consisted of the laser projector, camera, Pan&Tilt, and Attitude and Heading Reference System (AHRS). A camera-laser calibration test and simple 3D reconstruction test were performed in a water tank and the experimental results are reported.

여유구동 병렬기구의 기구학적 보정 (Kinematic Calibration Method for Redundantly Actuated Parallel Mechanisms)

  • 정재일;김종원
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.355-360
    • /
    • 2002
  • To calibrate a non-redundantly actuated parallel mechanism, one can find actual kinematic parameters by means of geometrical constraint of the mechanism's kinematic structure and measurement values. However, the calibration algorithm for a non-redundant case does not apply fur a redundantly actuated parallel mechanism, because the angle error of the actuating joint varies with position and the geometrical constraint fails to be consistent. Such change of joint angle error comes from constraint torque variation with each kinematic pose (meaning position and orientation). To calibrate a redundant parallel mechanism, one therefore has to consider constraint torque equilibrium and the relationship of constraint torque to torsional deflection, in addition to geometric constraint. In this paper, we develop the calibration algorithm fir a redundantly actuated parallel mechanism using these three relationships, and formulate cost functions for an optimization algorithm. As a case study, we executed the calibration of a 2-DOF parallel mechanism using the developed algorithm. Coordinate values of tool plate were measured using a laser ball bar and the actual kinematic parameters were identified with a new cost function of the optimization algorithm. Experimental results showed that the accuracy of the tool plate improved by 82% after kinematic calibration in a redundant actuation case.

  • PDF

레이저 구조광 영상기반 거리측정 센서 개발 (Development of Ranging Sensor Based on Laser Structured Light Image)

  • 김순철;이수영
    • 제어로봇시스템학회논문지
    • /
    • 제21권4호
    • /
    • pp.309-314
    • /
    • 2015
  • In this study, an embedded ranging system based on a laser structured light image is developed. The distance measurement by the structured light image processing has efficient computation because the burdensome correspondence problem is avoidable. In order to achieve robustness against environmental illumination noise and real-time laser structured light image processing, a bandpass optical filter is adopted in this study. The proposed ranging system has an embedded image processor performing the whole image processing and distance measurement, and so reduces the computational burden in the main control system. A system calibration algorithm is presented to compensate for the lens distortion.