• Title/Summary/Keyword: Laser Calibration

Search Result 251, Processing Time 0.023 seconds

Determination of Cholesterol by a Diode Laser/Fiber Optic Colorimetric Spectrometer

  • Kim, Seong Ho;Nam, Seong Man;Byeon, Sang Gil;Yun, Sin Yeong;Hong, Seong Sik
    • Bulletin of the Korean Chemical Society
    • /
    • v.21 no.4
    • /
    • pp.389-392
    • /
    • 2000
  • A simple and inexpensive colorimetric spectrometer for determining total cholesterol has been developed,comprising a diode laser as the light sourcoptical fibers for the light guide and a photodiode as the detector.The stabilty and performance of the new system was investigated by obtaining the calibration curve for stan-dard cholesterol solutions. The total cholesterol in humanserum was also measured by the analyzer and com-pared with the value obtained by a conventional spectrometer. The results showed that the developed spectrometer was useful for the determination of cholesterol levels. The visible diodelaser used in the study exhibited good spectroscopic and operational properties for colorimetric absorption spectrometry and could be a key component for the development of a simple and economical analyzer.

A Non-contact Shape Measuring System Using an Artificial Neural Network

  • Jeong, Woo-tae;Lee, Myung-Chan;Koh, Duck-joon;Cho, Hyung-suck
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.399-404
    • /
    • 1996
  • We developed a non-contact shape measuring device using computer image processing technology. We present a method of calibrating a CCD video camera and a laser range finder which is the most important step toward making an accurate shape measuring system. An artificial neural network is used for the calibration. Our measurement system is composed of a semiconductor laser. a CCD video camera, a personal computer, and a linear motion table. We think that the developed system could be used for measuring the change in shape of the spent nuclear fuel rod before and after irradiation which is one of the most important tasks for developing a better nuclear fuel. A radiation shield is suggested for the possible utilization of the range finder in radioactive environment.

  • PDF

Test bed for autonomous controlled space robot (우주로봇 자율제어 테스트 베드)

  • 최종현;백윤수;박종오
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1828-1831
    • /
    • 1997
  • this paper, to represent the robot motion approximately in space, delas with algorithm for position recognition of space robot, target and obstacle with vision system in 2-D. And also there are algorithms for precise distance-measuring and calibration usign laser displacement system, and for trajectory selection for optimizing moving to object, and for robot locomtion with air-thrust valve. And the software synthesizing of these algorithms hleps operator to realize the situation certainly and perform the job without any difficulty.

  • PDF

Image Blurring Estimation and Calibration with a Joint Transform Correlator

  • Jeong, Man Ho
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.5
    • /
    • pp.472-476
    • /
    • 2014
  • The Joint Transform Correlator (JTC) has been the most suitable technique for real time optical pattern recognition and target tracking applications. This paper proposes a new application of the JTC system for an analysis of the blurring effect of the optical images caused by a defocused lens. We present the relation between the correlation peak, optical transfer function (OTF), and the amount of blurring caused by focusing error. Moreover, we show a possibility of calibrating the blurred image by simply measuring the correlation peak.

Ultrasensitive Trace Determination of Pb by Two-Color Resonance Ionization Mass Spectrometry

  • 송규석;차형기;이종민;박종윤;허영덕
    • Bulletin of the Korean Chemical Society
    • /
    • v.16 no.7
    • /
    • pp.578-582
    • /
    • 1995
  • The resonance ionization mass spectrometry (RIMS) system with angular reflectron type time-of-flight mass spectrometer (AREF-TOFMS) has been developed and characterized. The system is applied for the ultratrace determination of Pb element. The 2-color 3-photon laser ionization scheme is adopted for the study and the mass resolution of the system is determined as T/ΔT=1680. The calibration curve for Pb is obtained in the range of 100 ppb to 0.01 ppb by using standard solutions. The minimal amount of detection for the present RIMS system is determined as less than 100 femtograms (10-13 gram).

Temperature Field Measurement of Non-Isothermal Jet Flow Using LIF Technique (레이저형광여기(LIF)를 이용한 비등온 제트유동의 온도장 측정)

  • Yoon, Jong-Hwan;Lee, Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.10
    • /
    • pp.1399-1408
    • /
    • 2000
  • A 2-dimensional temperature field measurement technique using PLIF (Planar Laser Induced Fluorescence) was developed and it was applied to an axisymmetric buoyant jet. Rhodamine B was used as a fluorescent dye. Laser light sheet illuminated a two-dimensional cross section of the jet. The intensity variations of LIF signal from Rhodamine B molecules scattered by the laser light were captured with an optical filter and a CCD camera. The spatial variations of temperature field of buoyant jet were derived using the calibration data between the LIF signal and real temperature. The measured results show that the turbulent jet is more efficient in mixing compared to the transition and laminar jet flows. As the initial flow condition varies from laminar to turbulent flow, the entrainment from ambient fluid increases and temperature decay along the jet center axis becomes larger. In addition to the mean temperature field, the spatial distributions of temperature fluctuations were measured by the PLIF technique and the result shows the shear layer development from the jet nozzle exit.

Determination of Palladium in Water Samples Using Cloud Point Extraction Coupled with Laser Thermal Lens Spectrometry

  • Han, Quan;Huo, Yanyan;Yang, Na;Yang, Xiaohui;Zhai, Yunhui;Zhang, Qianyun
    • Journal of the Korean Chemical Society
    • /
    • v.59 no.5
    • /
    • pp.407-412
    • /
    • 2015
  • A preconcentration procedure for determination of palladium by laser thermal lens spectrometry (TLS) is proposed. It is based on cloud point extraction of palladium(II) ions as 2-(3,5-dichloro-2-pyridylazo)-5-dimethylaminoaniline (3,5-diCl-PADMA) complexes using octylphenoxypolyethoxyethanol (Triton X-114) as surfactant. The effects of various experimental conditions such as pH, concentration of ligand and surfactant, equilibration temperature and time on cloud point extraction were studied. Under the optimized conditions, the calibration graph was linear in the range of 0.15~6 ng mL−1, and the detection limit was 0.04 ng mL−1 with an enrichment factor of 22. The sensitivity was enhanced by 846 times when compared with the conventional spectrophotometric method. The recovery of palladium was in the range of 96.6%~104.0%. The proposed method was applied to the determination of palladium in water samples.

Person-following of a Mobile Robot using a Complementary Tracker with a Camera-laser Scanner (카메라-레이저스캐너 상호보완 추적기를 이용한 이동 로봇의 사람 추종)

  • Kim, Hyoung-Rae;Cui, Xue-Nan;Lee, Jae-Hong;Lee, Seung-Jun;Kim, Hakil
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.1
    • /
    • pp.78-86
    • /
    • 2014
  • This paper proposes a method of tracking an object for a person-following mobile robot by combining a monocular camera and a laser scanner, where each sensor can supplement the weaknesses of the other sensor. For human-robot interaction, a mobile robot needs to maintain a distance between a moving person and itself. Maintaining distance consists of two parts: object tracking and person-following. Object tracking consists of particle filtering and online learning using shape features which are extracted from an image. A monocular camera easily fails to track a person due to a narrow field-of-view and influence of illumination changes, and has therefore been used together with a laser scanner. After constructing the geometric relation between the differently oriented sensors, the proposed method demonstrates its robustness in tracking and following a person with a success rate of 94.7% in indoor environments with varying lighting conditions and even when a moving object is located between the robot and the person.

The Evaluation of Distance Accuracy and The Test Target Manufacturing of A Terrestrial Laser Scanner (TLS용 테스트 타깃의 개발과 거리측정 정확도 검증)

  • Lee, In-Su;Tcha, Dek-Kie;Suh, Ho-Suhng
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.30 no.3
    • /
    • pp.279-285
    • /
    • 2012
  • Albeit the use of terrestrial 3D laser scanner (TLS) in the parts of landslide monitoring, cultural heritage documentation, civil engineering, urban engineering, etc. is increasing more and more, there is no international standardization regulation about the accuracy evaluation of the geometric element values, target, instrument calibration and test procedures, etc. Accordingly, this study deals with the manufacturing of TLS performance test target and the evaluation of TLS distance measurement and shows its suitability as the test target.

System for Measuring the Welding Profile Using Vision and Structured Light (비전센서와 구조화빔을 이용한 용접 형상 측정 시스템)

  • Kim, Chang-Hyeon;Choe, Tae-Yong;Lee, Ju-Jang;Seo, Jeong;Park, Gyeong-Taek;Gang, Hui-Sin
    • Proceedings of the Korean Society of Laser Processing Conference
    • /
    • 2005.11a
    • /
    • pp.50-56
    • /
    • 2005
  • The robot systems are widely used in the many industrial field as well as welding manufacturing. The essential tasks to operate the welding robot are the acquisition of the position and/or shape of the parent metal. For the seam tracking or the robot tracking, many kinds of contact and non-contact sensors are used. Recently, the vision is most popular. In this paper, the development of the system which measures the shape of the welding part is described. This system uses the line-type structured laser diode and the vision sensor. It includes the correction of radial distortion which is often found in the image taken by the camera with short focal length. The Direct Linear Transformation (DLT) method is used for the camera calibration. The three dimensional shape of the parent metal is obtained after simple linear transformation. Some demos are shown to describe the performance of the developed system.

  • PDF