• 제목/요약/키워드: Laser Calibration

검색결과 251건 처리시간 0.032초

영상처리를 이용한 쇽업서버 너클 브라켓 홀 검사 방법 (Inspection of the Knuckle Bracket Holes of a Shock-Absorber using Image Processing Method)

  • 정규원;안계운
    • 한국생산제조학회지
    • /
    • 제19권6호
    • /
    • pp.768-775
    • /
    • 2010
  • Automotive industry is a major business area in this country and it becomes more and more important. In order to maintain high quality of vehicles, every parts should be inspected. Among them the inspection job of the knuckle bracket holes of the outer tube of shock-absorber has been done manually until now. So, it takes long time and every product can not be inspected. An automatized inspection system was proposed utilizing machine vision technology, which was composed of a slit beam laser, CCD camera, image processing computer, special jig and illuminating back lights. An algorithm which could process images of the laser and bracket holes, then gave the position, radius, roundness of the holes, was developed. This system was applied for the good and no good products and the performance was confirmed.

시각센서를 이용한 용접 Gap/Profile 모니터링 (Monitoring the Welding Gap/Profile with Visual Sensor)

  • 김창현;최태용;이주장;서정;박경택;강희신
    • 한국레이저가공학회:학술대회논문집
    • /
    • 한국레이저가공학회 2005년도 춘계학술발표대회 논문집
    • /
    • pp.3-8
    • /
    • 2005
  • The robot systems are widely used in the welding manufacturing. The essential tasks to operate the welding robot are the acquisition of the position and/or shape of the parent metal. For the seam tracking or the robot automation, many kinds of contact and non-contact of the system which monitors the shape of the welding part is described. This system uses the line-type structured laser diode and the visual sensor. It includes the correction of radial distortion which is often found in the image from the camera with short focal length. Direct Linear Transformation (DLT) is used for the camera calibration. The three dimensional shape of the parent metal is obtained after simple linear transformation. Therefore, the system operates in real time. Some experiments are carried out to evaluate the performance of the developed system.

  • PDF

레이저 용접 도어 인너의 성형해석과 금형설계 (Stamping Analyses of Laser Welded Door Inner and Die Design)

  • 김헌영;신용승;김관희;조원석
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1997년도 추계학술대회논문집
    • /
    • pp.65-71
    • /
    • 1997
  • Computer simulations and test trials are carried out to get the optimal conditions about the stamping die design of the tailor laser welded automotive door inner. Firstly, the stamping process including gravity deflection, bead calibration, binder wrap, forming and spring back, are analyzed by the computer simulation. The results of simulation shows good correspondance with those of test trial under the same conditions. The variables of parametric study which will be investigated in the simulation and test trials, are determined form the results of the first run. The formability under the various conditions is evaluated, which are the initial postion of blank, blank holding force, corner radius and the shape of drawbead. Finally, well controled sound product without fracture, wrinkling and excessive weldline movement is obtained.

  • PDF

길이 소급성을 갖는 AFM을 이용한 150nm 피치 측정 (150 nm Pitch Measurement using Metrological AFM)

  • 진종한
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.264-267
    • /
    • 2003
  • Pitch measurements of 150 nm pitch one-dimensional grating standards were carried out using an contact mode atomic force microscopy(C-AFM) with a high resolution three-axis laser interferometer. It was called as 'Nano-metrological AFM' In Nano-metrological AFM, Three laser interferometers were aligned well to the end of AFM tip. Laser sources of the three-axis laser interferometer in the nano-metrological AFM were calibrated with an I$_2$-stablilzed He-Ne laser at a wavelength of 633 nm. So, the Abbe error was minimized and the result of the pitch measurement using the nano-metrological AFM has a traceability to the length standard directly. The uncertainty in the pitch measurement was estimated in accordance with the Guide to the Expression of Uncertainty in Measurement(GUM). The Primary source of uncertainty in the pitch-measurements was derived from repeatability of pitch-measurement, and its value was approx 0.186 nm. Expanded uncertainty(k=2) of less than 5.23 nm was obtained. It is suggested that the metrological AFM is a useful tool for the nano-metrological standard calibration.

  • PDF

펨토초 및 나노초 레이저를 이용한 박막태양전지의 레이저 플라즈마 분광 분석 (Application of a LIBS technique using femtosecond and nanosecond pulses for the CIGS films analysis)

  • 이석희;최장희;;;;;정성호
    • 한국레이저가공학회지
    • /
    • 제17권4호
    • /
    • pp.7-13
    • /
    • 2014
  • In this work, the application of laser induced breakdown spectroscopy (LIBS) for the composition analysis of thin $Cu(In,Ga)Se_2$ (CIGS) solar cell films ($1-2{\mu}m$ thickness) is reported. For the ablation of CIGS films, femtosecond (fs) laser (wavelength = 343nm, pulse width = 500fs) and nanosecond (ns) laser (wavelength = 266nm, pulse width = 5ns) were used under atmospheric environment. The emission spectra were detected with an intensified charge coupled device (ICCD) spectrometer and multichannel CCD spectrometer for fs-LIBS and ns-LIBS, respectively. The calibration curves for fs-LIBS and ns-LIBS intensity ratios of Ga/Cu, In/Cu, and Ga/In were generated with respect to the concentration ratios measured by inductively coupled plasma optical emission spectrometry (ICP-OES).

  • PDF

The Small Angle Generator Based on a Laser Angle Interferometer

  • Eom, Tae-Bong;Jeong, Don-Young;Kim, Jae-Wan
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제8권3호
    • /
    • pp.20-23
    • /
    • 2007
  • To calibrate precision autocollimators, the Korean Research Institute of Standards and Science (KRISS) has built a small angle generator using a laser interferometer. The system is based on a sine bar mechanism in which the angle is determined from the ratio of two lengths. The rotational angle is measured by the angle interferometer and the heterodyne laser interferometer detects the relative displacement of two retro-reflectors attached to the rotating arm. The distance between the two retro-reflectors of the laser angle interferometer is self-calibrated by an index table positioned on the rotating arm. The resolution of the system is 0.002 seconds, and the accuracy is better than 0.04 seconds within a measuring range of $\pm$1 degree. The small angle generator can also be used with an index table that can divide one circle into 1440 angles. The combined system can generate any angle over 360 degrees to an accuracy of 0.11 seconds.

자기 변형 공진 기구를 이용한 레이저 스캐닝 진동측정기에 관한 연구 (A Study on a Laser Scanning Vibrometer Using a Magnetostrictive Resonant Device)

  • 이정화;류제길;박기환
    • 한국정밀공학회지
    • /
    • 제15권11호
    • /
    • pp.58-66
    • /
    • 1998
  • A low power consuming laser scanning vibrometer is studied for its development. For its optical system, a laser interferometer is constructed to use the Doppler effect. In order to reduce the driving power of the scanning system, a small displacement of the scanning system is produced, which is achieved by using a magnetostrictive actuator. A sufficient rotating angle of the scanning system is obtained by using an amplified displacement from the resonant phenomena of a second order mechanical system composed of a mass and spring. The control of the magnetostrictive actuator using a Terfenol-D is performed without using a feedback system to help reduce the power consumption. The vibration analysis is made for the sinusoidal scanning input to have the space domain information from the time domain of the velocity of a vibration object. As a partial work of development of a tow power consuming laser scanning vibrometer, in this work, a scanning system which has the above features is developed and experimentally investigated. For the purpose of the optical system calibration, the vibration measurement for one axis is presented and the future works are discussed.

  • PDF

이동식 레이저 유도 파열 검출 장치를 이용한 KURT 지하수 내 콜로이드 나노 입자 검출 (Detection of Colloidal Nanoparticles in KURT Groundwater by a Mobile Laser-Induced Breakdown Detection System)

  • 정의창;조혜륜;박미리;백민훈
    • 방사성폐기물학회지
    • /
    • 제9권1호
    • /
    • pp.41-48
    • /
    • 2011
  • 한국원자력연구원 내 지하 처분 연구시설(KURT)에서 채취한 지하수에 존재하는 나노 콜로이드 입자의 크기 및 농도를 현상에서 조사하기 위해 이동식 레이저 유도 파열 검출 장치를 개발하였다. 제작한 장치는 CCD 카메라를 이용하여 레이저 유도 플라즈마가 발생한 위치를 2-차원 영상으로 기록함으로써 광학적으로 입자의 크기를 결정할 수 있다. 크기가 정확히 알려진 폴리스틸렌 표준 입자를 이용하여 입자 크기 측정용 검정 곡선 (calibration curve)을 구했고, 이를 이용하여 지하 처분 연구시설에서 채취한 지하수 내 콜로이드 입자의 크기를 측정하였다. 지하수 내 존재하는 콜로이드 입자의 평균 크기는 $108{\pm}26$ nm 임을 보였고, 농도는 50 ppb 이하인 것으로 추정하였다.

Edge Detecting Algorithm을 이용한 OLED 보호 필름의 Real Time Inspection에 대한 연구 (A study on real time inspection of OLED protective film using edge detecting algorithm)

  • 한주석;한봉석;한유진;최두선;김태민;고강호;박정래;임동욱
    • Design & Manufacturing
    • /
    • 제14권2호
    • /
    • pp.14-20
    • /
    • 2020
  • In OLED panel production process, it is necessary to cut a part of protective film as a preprocess for lighting inspection. The current method is to recognize only the fiducial mark of the cut-out panel. Bare Glass Cutting does not compensate for machining cumulative tolerances. Even though process defects still occur, it is necessary to develop technology to solve this problem because only the Align Mark of the panel that has already been cut is used as the reference point for alignment. There is a lot of defective lighting during panel lighting test because the correct protective film is not cut on the panel power and signal application pad position. In laser cutting process to remove the polarizing film / protective film / TSP film of OLED panel, laser processing is not performed immediately after the panel alignment based on the alignment mark only. Therefore, in this paper, we performed real time inspection which minimizes the mechanism tolerance by correcting the laser cutting path of the protective film in real time using Machine Vision. We have studied calibration algorithm of Vision Software coordinate system and real image coordinate system to minimize inspection resolution and position detection error and edge detection algorithm to accurately measure edge of panel.

표준거리측정 시설을 이용한 지상라이다 성능 평가 (Performance evaluation of Terrestrial Laser Scanner over Calibration Baseline)

  • 이인수;이재원
    • 한국측량학회지
    • /
    • 제28권3호
    • /
    • pp.329-336
    • /
    • 2010
  • 본 연구는 시간차방식(TOF: Time of flight)과 근적외선 파장대역(760-3000nm)을 사용하는 지상라이다를 이용해서 다양한 사용자 타깃에 대해 반사도와 거리정확도를 테스트하였다. 특별히 사용자 타깃에 대한 측점군의 반사도는 실내에서 독일 Gretag Macbeth사의 i1 분광광도계로 측정되었다. 그리고 지상라이다의 성능 평가를 위해 정밀 EDM 검기선장에서 지상라이다를 이용해서 타깃을 스캐닝 하여 기준표석간 이격거리를 측정하여 표준거리와 비교하였다. 테스트 결과로서, 약 10m 와 170m 기준표석간 이격거리에 설치된 흰색 수지 타깃을 제외하고, 실험에 이용된 다른 타깃들의 거리측정값은 기준거리와 수 mm 정확도 차이를 보였다. 향후 대기보정, 장비보정, 부가상수와 같이 거리정확도에 영향을 미치는 변수들에 대한 연구가 필요할 것으로 사료 된다.