A case study of large-scale slope failure in Granite - Andesite contact area (화강암-안산암 접촉부 대규모 사면의 붕괴 사례 연구)

  • 이수곤;양홍석;황의성
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.503-508
    • /
    • 2003
  • In this study, we peformed ahead a field geological investigation, boring investigation for slope stability analysis in large scale slope failure area. But the geological stratum was not clearly grasped, because ground was very disturbed by large scale Granite intrusion. Furthermore, the existing test data was not pertinent to the large scale Granite intrusion site like here. Therefore, various kind of field test were performed to grasp clearly for geological stratum. And the results of back analysis, various kind tests used to slope stability analysis.

  • PDF

Performance Trial-Test of the Full-Scale Driving Pump for the Large Cavitation Tunnel(LCT) (대형캐비테이션터널(LCT) 실물 구동펌프 성능시운전)

  • Ahn, Jong-Woo;Kim, Gun-Do;Kim, Ki-Sup;Park, Young-Ha
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.52 no.6
    • /
    • pp.428-434
    • /
    • 2015
  • The objective of the present study is to analyze the results of the trial-test for the full-scale driving pump, which is arranged in the LCT (Large Cavitation Tunnel). Firstly, the reasons of selecting the final design pump are introduced in terms of the performance analysis in model tests. The trial-test items for the full-scale driving pump are measurements of output current/voltage at the inverter of the main motor and the flow velocity in the LCT test section. The test results show the increase in flow rate of about 10.7% and the decrease in pump head of about 26%, compared with those of final design-pump specification. The motor power has the margin of about 22%. The performance analysis for the full-scale pump is conducted using the commercial code (CFX-10). The delivered power calculated with CFX-10 shows good agreement with that extracted from the full-scale pump test. It is found that CFX-10 is useful to analyze a full-scale pump.

An Experimental Study on the Evaluation of Shear Strength of Weathered Soil Containing Coarse Particles (굵은 입자가 포함된 풍화토의 전단강도 평가에 대한 실험연구)

  • Joon-Seok Kim
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.1
    • /
    • pp.169-176
    • /
    • 2024
  • Purpose: In this paper, an experimental study was conducted to analyze the difference in shear strength caused by the problem of excluding coarse particles due to the size of the test specimen in the direct shear test. Method: A large-scale direct shear test was conducted on three weathered soils containing coarse aggregates with a maximum diameter of 50mm. In addition, a small-scale direct shear test was performed using a sample with a maximum diameter of 5 mm, excluding coarse aggregates. Result: In the case of the small-scale direct shear test, compared to the results of the large-scale direct shear test containing large particles, the internal friction angle was about 2.3% smaller, and there was no significant difference. In terms of cohesion, compared to the large-scale direct shear test, the small-scale direct shear test derived about 80.3% smaller value, showing a relatively large difference. Conclusion: In the large-scale direct shear test, it was analyzed that the coarse particles had a greater impact on the cohesion than the internal friction angle. Therefore, granite weathered clay containing coarse particles is judged to have the same shear strength as the cohesive force that is not affected by vertical stress. In this study, it was analyzed that the small-scale direct shear test, which excludes the coarse particles that are commonly used, provides results on the safety side by excluding the effect of coarse particles.

Evaluation of Strength Parameters of North-Cheju Basalt Rubble Using Large-Scale Triaxial Test (대형삼축압축시험을 이용한 북제주현무암 사석재의 강도정수 산정)

  • 정철민;김종수;채영수
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.189-196
    • /
    • 2002
  • According to the Korean Design Code for port and harbor facilaties, bearing capacity of rubble mound under eccentric and inclined load is calculated by the simplified Bishop method, and strength parameters are recommended to be c=0.2kg/$\textrm{cm}^2$ and ø=35$^{\circ}$for standard rubble if the compressive strength of parent rock is greater than 300kg/$\textrm{cm}^2$, quoting from research results by Jun-ichi Mizukami(1991), But this facts have never been certified in Korea because there was not large-scale triaxial test apparatus until 2000 in Korea. Firstly in Korea, the large-scale triaxial test (sample diameter, 30cm and height, 60cm) on the rubble originated from porous basalt rock in North-Cheju was accomplished. Then strength parameters for basalt rubble produced in North-Cheju are recommended to be c=0.3kg/$\textrm{cm}^2$ and ø=36$^{\circ}$if the compressive strength of parent rock is greater than 400kg/$\textrm{cm}^2$.

  • PDF

Fracture Mechanics Study on Wear Mechanism of Ceramics -Discussions on Experimental Results of Wear Test- (세라믹의 마멸기구에 관한 파괴역학적 연구 -마멸실험 결과의 고찰-)

  • 김석삼;김재호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.3
    • /
    • pp.636-645
    • /
    • 1990
  • Analytically induced wear mechanism of elastic body under Hertzian contact is applied in acutual wear test of ceramics. There are two types of wear in ceramics, a large scale wear and a small scale wear. The large scale wear is commensurable with Hertzian contact area and the small scale wear with real contact area. Nondimensional parameter, S$_{c}$, is introduced and fully examined to estimate or predict wear rate of ceramics. Ceramic wear for S$_{c}$.leq.0.8 is in small scale wear and for S$_{c}$;geq.1.6 in large scale wear. wear.

Comparison of Shear Behavior for Quarry Blasted Rocks Based on Large Scale Direct Shear Test and Large Scale Triaxial Test (대형직접전단시험과 대형삼축시험을 통한 석산골재의 전단거동 특성 비교)

  • Lee, Dae-Soo;Kim, Kyoung-Yul;Oh, Gi-Dae
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.2
    • /
    • pp.5-14
    • /
    • 2008
  • Shear characteristics of quarry blasted rocks were compared using large scale direct shear tests and triaxial tests. For comparison purpose, similar test conditions were simulated as much as possible and three types of relative density (50%, 70%, 90%) were employed for the test. Results indicate that stress-strain behavior shows the same trend for two tests, but the measured shear strengths differ for the different test ms and depends on the relative density. At low relative density, the internal friction angles from direct shear test are smaller than those from triaxial tests. However, at high relative density, this phenomenon is reversed.

A study on the vehicle fire property using the large scale calorimeter (대형칼로리미터를 이용한 차량 화재 특성에 관한 연구)

  • Yoo, Yong-Ho;Kim, Heung-Youl;Shin, Hyun-Jun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.9 no.4
    • /
    • pp.343-349
    • /
    • 2007
  • The reduced scale fire test provides basic data but it is not enough to analysis real fire problem directly because there is no exact analogy theory between a real fire and the reduced scale model. Therefore we have developed the large scale calorimeter in order to the real scale fire test. This advanced large scale calorimeter used for physical properties such as a heat release rate, based upon consumption of $O_2$ method. Using this large scale calorimeter, we cameo out the real scale vehicle fire test in order to evaluation for heat release rate. We obtained the calculated result for HRR $2.3{\sim}3.4\;MW$ and this result is very similar to the PIARC candidate HRR. It is approve that this facility has the reliability and it is capable of applying to the advance fire research in the future.

  • PDF

The Study of Development and Calibration for the Real Scale Fire Test Facility (실대형화재평가장치의 개발 및 안정화에 관한 연구)

  • Yoo, Yong-Ho;Kim, Heung-Youl;Shin, Hyun-Jun
    • Fire Science and Engineering
    • /
    • v.22 no.1
    • /
    • pp.37-44
    • /
    • 2008
  • The reduced scale fire test provides basic data but it is not enough to analysis real fire problem directly because there is no exact analogy theory between a real fire and the reduced scale model. Therefore, we have developed the 10 MW large scale calorimeter in order to real scale fire test. This advanced large scale calorimeter used for physical properties such as a heat release rate, based upon consumption of $O_2$ method. Using the heptane pool fire, we carried out the calibration in order to evaluation for heat release rate. It is approve that this facility has the reliability and it is capable of applying to the advance fire research in the future.

An Experimental Study on the Warehouse Mock-up Fire Test (창고 모델 실물화재 특성에 대한 실험적 연구)

  • Kweon, Oh-Sang;Yoo, Yong-Ho;Kim, Heung-Youl
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.47-54
    • /
    • 2010
  • This study is analyze the damage of warehouse fire accident be made through the fire characteristic database of combustibles and real scale fire test of warehouse mock-up. Combustibles fire tests are carried out for database using RCT (Room Corner Tester) to predict fire growth the goods. A mockup ($3m{\times}3m{\times}2.4m$) of clothes warehouse was built and real scale fire test by LSC (Large Scale Calorimeter) base on the fire characteristic DB. The mock-up of clothes warehouse is made of two type sandwich panels (Glass wool, EPS foam sandwich panel). As a mock-up test result, test 1 (Glass wool sandwich panel) and test 2 (EPS foam sandwich panel) indicating fire growth such as 5 MW, 11 MW of maximum HRR (Heat Release Rate).

Adoption of the large scale free-free resonant column test (대형 공진주 시험 장비의 적용)

  • Park, In-Beom;Park, Chul-Soo;Mok, Young-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.626-633
    • /
    • 2009
  • A large scale resonant column testing equipment is under development. The would-be equipment is aiming to test 150mm-diameter specimens, which can contain as large a grain size as 25mm. Such a large specimen is hardly excitated with the existing fixed-free end condition because the torsional force cannot be effectively coupled to the specimen. The specimen will be rather resonated with free-free condition and the scheme is implemented with a rotational bearing installed between coil-magnet exciter and base pedestal. Presently the equipment was assembled and is under calibration with a cylindrical brass specimen.

  • PDF