• 제목/요약/키워드: Large-diameter pipe

검색결과 137건 처리시간 0.03초

실험계획법을 이용한 반도체용 대구경 스테인레스관의 내경 가공에 관한 연구 (A study on the Internal machining of a large-diameter Stainless pipe for Semiconductor Using Experimental Design Method)

  • 김창근;이은상
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2003년도 추계학술대회
    • /
    • pp.71-76
    • /
    • 2003
  • This paper describes the characteristic of a large-diameter pipe to obtain smooth surface using Electropolishing after grinding using a non-woven fabric. Grinding using a non-woven fabric is possible under lower load and fine effect comparing with Wheel grinding. Also, the ion from the surface of the metal is eliminated by means of an electrical potential and current in Electropolishing. Electropolishing is used for leveling the surface, improving the physical appearance of the part, promoting corrosion properties and reducing contamination and adhesion of the surface. Therefore, the aim of the present study is to investigate the internal machining of a large-diameter pipe for semiconductor using experimental design method.

  • PDF

주변환경을 고려한 상수관망의 관 마찰손실계수 산정 (Predicting Flow Resistance Coefficients in Water Supply Mains)

  • 손광익
    • 물과 미래
    • /
    • 제29권4호
    • /
    • pp.223-231
    • /
    • 1996
  • 보다 효율적인 관로운영에 필수적인 통수능 변화 및 영향인자 산정을 위하여 국내 도송수강관에 대하여 124개의 Hazen Williams및 Darcy-Weisbach 마찰계수를 실측, 분석하였다. 그 결과 국내 도송수강관은 국외의 마찰계수 변화형태와 유사한 경향을 보이며 관경이 클수록 (Diameter>1100mm) 통수능은 관령에 많은 영향을 받으나 관경이 작을수록 관경과 관령에 동시에 영향을 받는다는 사실을 알았다. 또한 Hazen Williams의 C 값은 외국에 비해 약 5-10 정도 작은 것으로 나타났으며, 조도높이의 성장률은 약 0.41 mm/년으로 관의 통수능이 외국에 비해 빨리 저하한다는 사실이 밝혀져 그 원인 파악 및 통수능 산정기준을 재 검토해야 할 것으로 판단되었다. For the most efficient operation of water mains, 124 head losses in domestic water supply steel mains were measured to provide the values of friction coefficient and the variable affecting the deterioration rate of Hazen Williams' and Darcy-Weisbach's friction coefficient. The experimental results show that pipe age is governing the friction coefficient of large mains (Diameter > 1100 mm). On the other hands, pipe age and pipe diameter are affecting the variation of carrying capacity for small mains (Diameter < 1100 mm). The friction coefficient of water mains in foreign countries is higher than that in Korea by about 5 to 10 in Hazen Williams' C value. The growing rate of roughness height of domestic water main is about 0.41 mm/year which is higher than the average of United States of America. So further study is required to find out what causes the serious deterioration rate.

  • PDF

대구경 곡관 두께감소율 제어를 위한 온도점프 벤딩 공정의 최적화에 관한 연구 (Study on Optimization of Temperature Jump-Bending Process for Reducing Thickness Attenuation of Large-Diameter Steel Pipe)

  • 허철수;김래성;전정환;양용군;최효규;류성기
    • 한국기계가공학회지
    • /
    • 제14권4호
    • /
    • pp.21-27
    • /
    • 2015
  • Induction bending is a method that allows the bending of any material that conducts electricity. This technology applies a bending force to a material that has been locally heated by an eddy current induced by a fluctuating electromagnetic field. Induction bending uses an inductor to locally heat steel through induction. This results in a narrow heat band in the shape to be bent. In general, the reduction of thickness attenuation of a large-diameter steel pipe is not allowed to exceed 12.5%. In this paper, in order to meet the standard of thickness attenuation reduction, a non-uniform heating temperature jump-bending process was investigated. As a result, the developed bending technique meets the requirements of thickness attenuation reduction for large-diameter steel pipes.

분리형 에어컨용 2중 열교환 배관 특성에 관한 실험적 연구 (Experimental Study of Characteristics on Double Heat Exchange Pipe Used Separation Type Air-Conditioner)

  • 김재돌
    • 동력기계공학회지
    • /
    • 제10권4호
    • /
    • pp.31-37
    • /
    • 2006
  • In this study, the ability for the function of double pipe inserted liquid pipe with small diameter in the gas pipe with large diameter for the circulating of liquid of high temperature and high pressure and low temperature and low pressure at the same time is presented. And in this double pipe, liquid pipe of high temperature and pressure is used to connect condenser and expansion valve and gas pipe of low temperature is used to connect evaporator and compressor. Also, when liquid refrigerant of high temperature and gas refrigerant of low temperature is circulated by reversed flow in the double pipe. The contribution of liquid gas heat exchange pipe is studied by comparison of the effect of heat transfer by temperature difference when liquid pipe and gas pipe is installed separately.

  • PDF

Plant-scale experiments of an air inflow accident under sub-atmospheric pressure by pipe break in an open-pool type research reactor

  • Donkoan Hwang;Nakjun Choi;WooHyun Jung;Taeil Kim;Yohan Lee;HangJin Jo
    • Nuclear Engineering and Technology
    • /
    • 제55권5호
    • /
    • pp.1604-1615
    • /
    • 2023
  • In an open-pool type research reactor with a downward forced flow in the core, pipes can be under sub-atmospheric pressure because of the large pressure drop at the reactor core in the atmospheric pool. Sub-atmospheric pressure can result in air inflow into the pipe from the pressure difference between the atmosphere and the inside of the pipe, which in a postulated pipe break scenario can lead to the breakdown of the cooling pump. In this study, a plant-scale experiment was conducted to study air inflow in large piping systems by considering the actual operational conditions of an advanced research reactor. The air inflow rate was measured, and the entrained air was visualized to investigate the behavior of air inflow and flow regime depending on the pipe break size. In addition, the developed drift-flux model for a large vertical pipe with a diameter of 600 mm was compared with other correlations. The flow regime transition in a large vertical pipe under downward flow was also studied using the newly developed drift-flux model. Consequently, the characteristics of two-phase flow in a large vertical pipe were found to differ from those in small vertical pipes where liquid recirculation was not dominant.

Influence of oil pipe corrosion defects on the sealing performance of annular BOP

  • Dong, Liangliang;Tang, Yuan;Wang, Liuyang
    • Structural Engineering and Mechanics
    • /
    • 제84권3호
    • /
    • pp.337-344
    • /
    • 2022
  • Due to corrosion defects on the surface of the oil pipe, the sealing performance of the annular blowout preventer (BOP) decreases, and the leakage of toxic and harmful gases such as H2S and SO2 will threaten the safety of operators on the well. Therefore, this paper establishes the FE model for evaluating the sealing performance of BOP-oil pipe corrosion defects, which is based on the rubber large deformation theory and rubber core sealing mechanism, and designs the experiment of BOP sealing performance to verify the accuracy of the FE model. The sealing performance of BOP sealing oil pipe with corrosion defects is studied. The research results show that the sealing performance of BOP is more sensitive to the axial size of corrosion defects. With the increase of oil pipe outer diameter, the critical size of defects increases continuously. The sensitivity of radial and depth dimensions is low, When for 88.9 mm outer diameter oil pipe, the axial critical size of corrosion defect is 20 mm, the radial critical size is 16 mm and the critical depth is 2 mm. Fit the formula between the outer diameter of oil pipe and the piston increment. According to the formula, the operator can calculate the piston stroke increment required by the BOP to complete the sealing when the oil pipe is corroded.

LES에 의한 원관 내 난류의 유동 해석 (Large Eddy Simulation of Turbulent Pipe Flow)

  • 고상철
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권3호
    • /
    • pp.437-446
    • /
    • 2003
  • A large eddy simulation (LES) is performed for turbulent pipe flow. The simulation code is constructed by using a general coordinate system based on the physical contravariant velocity components. The effects of grid fineness which can be well prediction of turbulent behavior in near wall region is investigated. The subgrid scale turbulent models are applied and validated emphasis is placed on the flow details of turbulent pipe flow The calculated Reynolds number is 360 based on the wall shear velocity and the inlet pipe diameter. The predicted turbulent statistics are evaluated by comparing with the DNS data of turbulent pipe flow Performed by Eggels et al. The agreement of LES with DNS data is shown to be satisfactory. The proper grid fineness of the well prediction of turbulent pipe flow is suggested and the turbulent behavior is analyzed by depict the contour plot of fluctuating velocity components.

3차원 수치해석을 이용한 대구경 무용접 복합말뚝의 지지거동 분석 (Evaluation of Bearing Capacities of Large Size Non-welded Composite Piles by 3-Dimensional Numerical Analysis)

  • 박재현;김성렬;;정문경
    • 한국해양공학회지
    • /
    • 제25권6호
    • /
    • pp.35-41
    • /
    • 2011
  • Recently, as large structures, which should support large design loads have been constructed, the study on the large diameter composite pile becomes necessary. The large diameter composite pile has the diameter over 700mm and consists of two parts of the upper steel pipe pile and the lower PHC pile by a mechanical joint. In this research, to analyze the bearing capacity and the material strength of the composite pile, three dimensional numerical analyses were performed. First, the numerical modeling method was verified by comparing the calculated load-movement curves of the pile with those of the field pile load tests. Then, a total of twelve analyses were performed by varying pile diameter and loading direction for three pile types of PHC, steel pipe and composite piles. The results showed that the vertical and the horizontal load-movement curves of the composite pile were identical with those of the steel pipe pile and the horizontal material strength of the composite pile was 60-80% larger than that of the PHC pile.

대구경 소켓경사반력말뚝의 인발거동에 관한 연구

  • 최용규;김상옥;정창규;정성기;김상일
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.277-284
    • /
    • 2000
  • Using the large diameter (D = 2,500mm, L = 40m) batter steel pipe piles, designed as compression piles but used as reaction piles during the static compression load test of socketed test piles (D = 1,000mm, L = 40m), static pile load tests for large diameter instrumented rock-socketed piles were performed. The reaction steel pipe piles were driven 20m into the marine deposit and weathered rock layer and then l0m socketed with reinforced concrete through the weathered rock layer and into hard rock layer. Steel pipe and concrete in the steel pile part, and concrete and rebars in the socketed parts were instrumented to measure strains in each part. The pullout amounts of reaction pile heads were also measured with LVDT. During the static pile load test, total compressional load of about 20MN was loaded on the head of test piles, but load above 20MN was not loaded due to lack of loading capacity of loading system. Over the course of the study, maximum pullout amount up to 7mm was measured in the heads of reaction piles when loaded op to 10MN and 1mm of pullout amount was measured. More than 85% of pullout load was transfered in the residual weathered rock layer and about 10% in the soft rock layer, which was somewhat different transfer mechanism in the static compressional load tests.

  • PDF