• Title/Summary/Keyword: Large-area measurement

Search Result 361, Processing Time 0.027 seconds

Comparative study on modal identification methods using output-only information

  • Yi, Jin-Hak;Yun, Chung-Bang
    • Structural Engineering and Mechanics
    • /
    • v.17 no.3_4
    • /
    • pp.445-466
    • /
    • 2004
  • In this paper, several modal identification techniques for output-only structural systems are extensively investigated. The methods considered are the power spectral method, the frequency domain decomposition method, the Ibrahim time domain method, the eigensystem realization algorithm, and the stochastic subspace identification method. Generally, the power spectral method is most widely used in practical area, however, the other methods may give better estimates particularly for the cases with closed modes and/or with large measurement noise. Example analyses were carried out on typical structural systems under three different loading cases, and the identification performances were examined throught the comparisons between the estimates by various methods.

Measurement of Atmospheric VOC Concentrations at a Roadside in a Large Urban Area (대도시 도로변 대기 중 휘발성 유기화합물의 농도측정)

  • 김미현;백성옥;김성렬;황승만;문영훈;정진욱;신주희
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 1999.10a
    • /
    • pp.383-384
    • /
    • 1999
  • 도시대기 중의 광화학 대기오염의 원인인 동시에 사람의 건강상에 유해한 성분(발암성 혹은 돌연변이성)들이 많이 존재하는 것으로 알려진 대기오염물질 중에서도 탄화수소성분에 대한 관심이 최근들어 고조되고 있다. 메탄을 제외한 탄화수소성분을 총칭하여 비메탄계 탄화수소(NMHC)라고 일컫고 있으며, 비메탄계 탄화수소는 알데히드등의 산소화합물을 함유하고 있지 않지만, 휘발성 유기화합물(Volatile Organic Compounds;이하 VOCs)은 산소함유화합물을 포함한 물질을 말한다.(중략)

  • PDF

The Comparison of X-ray Response Characteristics of Vacuum Evaporated (진공증착된 CdTe와 $Cd_{0.85}Zn_{0.15}Te$ 필름의 X선 반응특성 비교)

  • Kang, S.S.;Choi, J.Y.;Cha, B.Y.;Moon, C.W.;Kim, J.H.;Nam, S.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.845-848
    • /
    • 2002
  • The study of photoconductor materials is demanded for development for flat-panel digital x-ray Imager. In this paper, We investigated the feasibility of application as x-ray image sensor using Cd(Zn)Te compound with high stopping power on high radiation. These Cd(Zn)Te samples were fabricated by vacuum thermal evaporation method to large area deposition and investigated I-V measurement as applied voltage. The experimental results show that the additional injection Zn in CdTe film reduced the leakage current, for the $Cd_{0.85}Zn_{0.15}Te$ detector, the net charge had the highest value as $144.58pC/cm^2$ at 30 V.

  • PDF

A Research on the Somatotypes of Female College Students

  • Kwon, Sook-Hee
    • International Journal of Human Ecology
    • /
    • v.8 no.1
    • /
    • pp.19-26
    • /
    • 2007
  • The object of this research was to observe the female college 220 students of aged 19-24 for four years and to examine somatotypes distribution; this research intends to contribute to the fitness of clothes by studying the body distribution that affects the clothing structure. The measurement and wearing experiment for somatotypes are done years annually. The average, standard deviation and coefficient of variation was calculated by the SAS program. The research results are as follows: The three somatotypes of side view silhouette (straight type, bend-forward type, lean-back type) showed fairly even distribution. As a result of dressing experiment with the basic bodice pattern, the most influential factor on its suitability was found to be the neck area, shoulder and ease of bodice respectively. The partial body types to observe were categorized as: shoulder(normal, slope, squared), bust(A cup, B cup, C cup), hips (normal, droop, projecting). As for the result for full body type by BMI, normal type was most dominant, and for the categorization by drop, the type A which is with small breasts and large hips was most prevalent.

Effect of Cut-off Angle on Flow Pattern of Centrifugal Multi-blade Fan (원심 다익홴의 유동에 대한 컷 오프 각도의 영향)

  • Kang, Kyung-Jun;Shin, You-Hwan;Lee, Yoon-Pyo;Kim, Kwang-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.3
    • /
    • pp.37-42
    • /
    • 2010
  • This study investigated on details of flow characteristics of a multi-blade fan for domestic ventilation. Experiments and analysis were carried out to describe on flow pattern with variations of cut-off angle near the scroll housing throat, which were performed by PIV measurement for the flow field and by total pressure probes. The stagnation point at cut-off region of the fan moves to the exit of the scroll housing as the cut-off angle increases. The movement of stagnation point and the variation of throat area of the scroll housing influence to the distribution of velocity magnitude at the exit of the fan. Furthermore, a large distortion of the velocity distribution at the scroll exit causes to increase mixing loss along the flow path.

Visualization of the Slurry Flow-Field during Chemical Mechanical Polishing by PIV (PIV를 이용한 Chemical Mechanical Polishing 공정 중의 연마용액 유동흐름 측정)

  • Shin Sanghee;Kim MunKi;Yoon Youngbin;Koh Young-Ho
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.48-51
    • /
    • 2004
  • Chemical Mechanical Polishing(CMP) is popularly used in production of semiconductor because of large area polishing ability probability of improvement for more integrated circuit. However, present CMP processing causes some non-uniformity errors which can be critical for highly integrated circuit. Previous studies predict that flow-field of slurry during CMP can create non-uniformity, but no quantitative measurement has conducted. In this study, using PIV, slurry velocity flow-field during CMP is measured by changing the ratio of RPM of pad and carrier with tuned PIV system adequate for small room in CMP machine and Cabot's non-groove pad Epad-A100. The result show that velocity of slurry is majorly determined by pad-rpm and the ratio of between carrier and pad rpm make some changes in streamlines.

  • PDF

An Investigation of Lattice Boltzmann Multi-phase Model and it Application (래티스볼츠만 다상류 모델의 검토 및 응용)

  • Kang, Ho-Keun;Ahn, Soo-Whan
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.269-270
    • /
    • 2006
  • A finite difference lattice Boltzmann model which allows us to simulate gas-liquid two-phase flows with large density difference, for instance, 800 times for air and water is considered. Two-particle model is used and the density difference is introduced by changing the acceleration according to the fluid density. Numerical measurement of surface tension agrees well with theoretical predictions. Simulations of two-phase phenomenon for phase-transition is carried out, showing applicability of the model for two-phase flows. The two-dimensional cavitating flow around a board set up in the fluid way is also simulated. As a result, it was confirmed that the FDLB method with two-particle model was effective in numerical simulation of cavitating flow and the bubble periodically grew up at the low pressure area behind the board, in which the fluid condition was influenced by the cavitation number.

  • PDF

Optimizing Content Duration for Mobile Ads

  • Truong, Vinh
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.5 no.4
    • /
    • pp.283-288
    • /
    • 2016
  • Optimizing the number of ad clicks is a large-scale learning problem that is central to the multi-billion-dollar mobile advertising industry. There are currently several optimization methods being used, including ad mediation and ad positioning. Recently, researchers have recommended using ad refresh interval as a new method for optimizing mobile advertising. This paper applies that new method to optimize content duration for mobile ads. The result achieved from this optimization study could further increase revenue for mobile advertisers and publishers. This research has high applicability for the growing mobile advertising industry. It also lays out a solid background for future research in this promising area.

Improvement of Sensitivity in Porous Silicon Alcohol Gas Sensors by UV Light (자외선조사에 의한 다공질 실리콘 알코올 센서의 감도 개선)

  • Kim, Seong-Jin;Choe, Bok-Gil
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.9
    • /
    • pp.676-680
    • /
    • 1999
  • To do breath alcohol measurement, a sensor is necessary that it can detect low alcohol gas concentration of 0.01% at least. In this work, a capacitance-type alcohol gas sensor using porous silicon layer is developed to measure low alcohol gas concentration. The sensor using porous silicon layer has some sensitivity at room temperature by very large effective surface area, but there is still much room for improvement. In this experiment, we measured the capacitance of the sensor under 254 nm UV light on the porous silicon layer, in which alcohol solution was kept in a flask at 25, 35, and $45^{\circ}C$ by a heater. As the result, the improvement of sensitivity by illuminating UV light was observed. The increasing rate of the capacitance was shown to be double more than those measured under UV-off state. It is supposed that UV light activates response of the oriental and interfacial polarizations which have slow relaxation time for AC field.

  • PDF

A Correlation Analysis between DSC (Dye Sensitized Cell) and Daylighting-Focusing on Educational Space (염료감응형 태양전지(DSC)와 자연채광의 상관관계 분석-교육공간을 중심으로)

  • Lee, Eung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.1
    • /
    • pp.35-47
    • /
    • 2020
  • Due to the large window area, the lighting environment of the educational space between the window and deep part of the room is not uniformly illuminated, and the phenomenon of glare is severe. For this reason, the daylight performance of DSC-BIPV windows was analyzed in order to improve the natural lighting in the educational sector. The method derives the correlation with natural lighting by measurement and simulation. Dynamic simulation confirmed that the average illuminance of the target space was higher at later than the early afternoon. The performance of natural lighting at 40% and 30% transmission of DSC has the effect of significantly reducing the amount of excess light in existing windows. Nevertheless, the actual average illuminance in all seasons corresponds to the standard illuminance of the educational facility, 300 Lux. In addition, the uniformity is also seen through the skylight illuminance ratio.