• Title/Summary/Keyword: Large-Scaled Building

Search Result 57, Processing Time 0.025 seconds

A Study on Remodeling Method of Library Architecture (도서관건축의 리모델링 수법)

  • Lee, Ji-Young
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.24 no.1
    • /
    • pp.3-10
    • /
    • 2017
  • This study is to analyze the remodeling method of library in terms of space extension method and urban regeneration by repurposing function in unused facilities through case study. In many case of library extension, horizontal extensions are more frequent than vertical extensions, because there are limits to extend vertically due to high live load estimation by book stacks. Extension schemes was organized by new building extension method in connection with existing buildings, attaching method small scaled mass or linear mass to existing building, connecting method a plurality of existing small buildings, vertical extension method on the top of the structure, underground extension method using special structure. Unused facility remodeling to the library, large scaled buildings can be developed completely to the function of the library through the relocation of the space, while small scaled building needs spatial extension. In the case of spatial extension, existing space that was used for other purposes can be used as a reading room or office, avoiding high live load estimation.

Shaking Table Test and Seismic Performance Evaluation of Shanghai Tower

  • Chunyu, Tian;Congzhen, Xiao;Hong, Zhang;Jinzhe, Cao
    • International Journal of High-Rise Buildings
    • /
    • v.1 no.3
    • /
    • pp.221-228
    • /
    • 2012
  • Shanghai Tower is a super high-rise building of 632 m height with 'mega frame-core- outrigger truss' structure system. Due to the complexity and irregularity of structure, shaking table test was carried out to investigate its seismic performance. A 1/40 scaled test model was designed, built and tested on shaking table under earthquake of small, moderate and large levels. The experimental results showed that the structure can meet the requirements of Chinese codes and reach scheduled performance objectives. Elastic and plastic time-history analysis on the structure were carried out and the results were compared to experimental results. Based on the research results some suggestions were proposed to contribute favorable effect on the seismic capacity of the structure.

A Study on the Analysis and Improvement methods of Emergency Medical Service Systems for Large Scaled Fire (대형화재에 대비한 응급의료체계에 관한 분석과 개선방안)

  • Lee, Maria
    • The Korean Journal of Emergency Medical Services
    • /
    • v.11 no.1
    • /
    • pp.41-52
    • /
    • 2007
  • In Korea, Crowds, as well as more complex and larger structures, have been caused more victims in the event of fire. In that situation, EMSS should have done triage the patients according to their severity in the field, treat with standard guidelines as like advanced burn life support and transfer to appropriate facility. But in many cases, they didn't practice like that. The purpose of this study is to give basic data for proper emergency medical services by analysing EMSS of large scaled fire in Korea and suggesting some improvement methods. The improvment methods are like this ; First, developing of protocols about burn patient is needed for EMT and dispatcher. Second, Legal approval for advanced treatment is needed for EMT. Third, Fire-helicoptors are needed in Daejeon and Jeju. And Emergency Medical Helicoptors are needed in EMSS. Forth, more advanced emergency medical centers of burn must be established. Sixth, more pocket-mask and burn sheet are needed for 119 rescuer. Finally, building owners must change inflammable materials as non-inflammable materials and educate fire-prevention and first-aid to employees.

  • PDF

A study on the Calculation of Noise Correction Coefficient on each floor for the estimation on the roadside traffic noise around the Apartment Building (도로변 공동주택의 층별 소음보정계수 산정에 관한 연구)

  • Park, Young Min;Lee, Ji Wang;Ko, Jung Yong
    • Journal of Environmental Impact Assessment
    • /
    • v.14 no.1
    • /
    • pp.25-36
    • /
    • 2005
  • Actually, prediction formula of road traffic noise for EIA(Environmental Impact Assessment) has been used that proposed by National Institute of Environmental Research in 1999. The prediction formula, however, was calculated predicted noise level according to noise level producing on first floor, then needs to correct noise level at each floor in the case of apartment building. The investigation was carried out to calculate the correction coefficient for commonly using in EIA of large scaled apartment development areas. The noised level at each floor were measured from August 2001 to March 2002 at 31 investigation points of large scaled apartment development area in national wide. Measured data were divided and treated with 4 types as 3th floor, 5th floor, 7th floor and 10th floor and then the correction coefficients of each floor were calculated using by correlation formula according to each floor.

Experimental Study on the Hysteretic Behavior of Large Concrete Panel Structures Subjected to Cyclic Load (반복하중을 받는 대형 콘크리트 판구조의 이력거동에 관한 실험적 연구-3층 대형판 구조체 실험결과를 중심으로)

  • 서수연;박병순;이봉효;김성수;이원호;이리형
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1992.10a
    • /
    • pp.179-184
    • /
    • 1992
  • Four 3-story 1/2 scaled large concrete panel structures were designed and tested to estimate the seismic resistance capacity of large concrete panel high rise building systems, Test specimens were modeled three story of 24 or 15 story buildings and set up to represent the actural stress of the building . The axial force was constant and the horizontal force was loaded by ductility ratio. Results indicated that the joints of specimens were behavied monolithically to maximum strength. It was shown that the joint box connecting system had lower maximum strength and energy dissipation capacity than welding connection system, but had better deformation capacity.

  • PDF

Damage and vibrations of nuclear power plant buildings subjected to aircraft crash part II: Numerical simulations

  • Li, Z.R.;Li, Z.C.;Dong, Z.F.;Huang, T.;Lu, Y.G.;Rong, J.L.;Wu, H.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.9
    • /
    • pp.3085-3099
    • /
    • 2021
  • Investigations of large commercial aircraft impact effect on nuclear power plant (NPP) buildings have been drawing extensive attentions, particularly after the 9/11 event, and this paper aims to numerically assess the damage and vibrations of NPP buildings subjected to aircrafts crash. In Part I of present paper, two shots of reduce-scaled model test of aircraft impact on NPP were conducted based on the large rocket sled loading test platform. In the present part, the numerical simulations of both scaled and prototype aircraft impact on NPP buildings are further performed by adopting the commercial program LS-DYNA. Firstly, the refined finite element (FE) models of both scaled aircraft and NPP models in Part I are established, and the model impact test is numerically simulated. The validities of the adopted numerical algorithm, constitutive model and the corresponding parameters are verified based on the experimental NPP model damages and accelerations. Then, the refined simulations of prototype A380 aircraft impact on a hypothetical NPP building are further carried out. It indicates that the NPP building can totally withstand the impact of A380 at a velocity of 150 m/s, while the accompanied intensive vibrations may still lead to different levels of damage on the nuclear related equipment. Referring to the guideline NEI07-13, a maximum acceleration contour is plotted and the shock damage propagation distances under aircraft impact are assessed, which indicates that the nuclear equipment located within 11.5 m from the impact point may endure malfunction. Finally, by respectively considering the rigid and deformable impacts mainly induced by aircraft engine and fuselage, an improved Riera function is proposed to predict the impact force of aircraft A380.

A Study on the Swelling Property of Bentonite Mat under Salt Water Condition (담수환경하에 노출된 일반 벤토나이트 매트재의 팽윤성능 평가)

  • 양승도;김영삼;유재강;오상근
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2002.05a
    • /
    • pp.81-84
    • /
    • 2002
  • Recently Bentonite mat is applied various structure : External waterproofing for underground structure, A reclaimed land, Artificial lake, Large-scaled civil structure, etc. With these various structure environment, water quality for application of Bentonite Mat affects watertightness. Specially spot with a large quantity of Chloride ion like salt water, degree of watertightness revelation is evaluated and applied. In this study, it is a main goal to investigate watertightness of Bentonite Mat with distilled water and salt water dissolved chloride ion Contents 0.88%. The result of this paper is as follows. 1) Water permeability coefficient of Bentonite Mat : distilled water(1.21$\times$10$^{-9}$cm/sec), salt water(3.12$\times$10$^{-7}$cm/sec). 2) Variation of thickness : distilled water(187%), salt water(108%). 3) Swelling ratio : distilled water(1500%), salt water(350%).

  • PDF

Analysis of Electromagnetic Effect Inside Large Buildings by External Electromagnetic Waves Using Performance-Enhanced PWB Method (성능이 보완된 PWB 방법을 사용한 외부 전자기파에 의한 대형 건물 내부의 전자기파 영향 해석)

  • Lee, Han-Hee;Lee, Jae-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.1
    • /
    • pp.12-22
    • /
    • 2019
  • This paper presents a method to perform a more efficient electromagnetic wave analysis inside a large building by external electromagnetic waves. Topological analysis and the PWB method are introduced for electromagnetic wave analysis. In addition, a Performance-Enhanced PWB method, which complements the performance of the PWB method is proposed. A large virtual structure was selected and an analysis environment was set up to perform the electromagnetic wave analysis inside a large building from external electromagnetic waves. A commercially available software, Wireless Insite, was used to verify the accuracy of the the Performance- Enhanced PWB method. As a result of comparing the two results in terms of accuracy, time, and memory, We conclude that the Performance-Enhanced PWB method proposed in this paper is a more efficient method in a large bulding.

Collapse Behavior of an 18-Story Steel Moment Frame during a Shaking Table Test

  • Suita, Keiichiro;Suzuki, Yoshitaka;Takahashi, Motomi
    • International Journal of High-Rise Buildings
    • /
    • v.4 no.3
    • /
    • pp.171-180
    • /
    • 2015
  • A shaking table test was conducted at the E-Defense shaking table facility to investigate the damage and collapse behavior of a steel high-rise building under exceedingly large ground motions. The specimen is a one-third scale 18-story steel moment frame designed and constructed according to design specifications and practices used in the 1980s and 1990s. The shaking table tests used a long-duration, long-period ground motion simulated for a sequential Tokai, Nankai, and Nankai earthquake scenario. The building specimen was subjected to a series of progressively increasing scaled motions until it completely collapsed. The damage to the steel frame began through the yielding of beams along lower stories and column bases of the first story. After several excitations by increasing scaled motions, cracks initiated at the welded moment connections and fractures in the beam flanges spread to the lower stories. As the shear strength of each story decreased, the drifts of lower stories increased and the frame finally collapsed and settled on the supporting frame. From the test, a typical progression of collapse for a tall steel moment frame was obtained, and the hysteretic behavior of steel structural members including deterioration due to local buckling and fracture were observed. The results provide important information for further understanding and an accurate numerical simulation of collapse behavior.

Probabilistic seismic performance evaluation of non-seismic RC frame buildings

  • Maniyar, M.M.;Khare, R.K.;Dhakal, R.P.
    • Structural Engineering and Mechanics
    • /
    • v.33 no.6
    • /
    • pp.725-745
    • /
    • 2009
  • In this paper, probabilistic seismic performance assessment of a typical non-seismic RC frame building representative of a large inventory of existing buildings in developing countries is conducted. Nonlinear time-history analyses of the sample building are performed with 20 large-magnitude medium distance ground motions scaled to different levels of intensity represented by peak ground acceleration and 5% damped elastic spectral acceleration at the first mode period of the building. The hysteretic model used in the analyses accommodates stiffness degradation, ductility-based strength decay, hysteretic energy-based strength decay and pinching due to gap opening and closing. The maximum inter story drift ratios obtained from the time-history analyses are plotted against the ground motion intensities. A method is defined for obtaining the yielding and collapse capacity of the analyzed structure using these curves. The fragility curves for yielding and collapse damage levels are developed by statistically interpreting the results of the time-history analyses. Hazard-survival curves are generated by changing the horizontal axis of the fragility curves from ground motion intensities to their annual probability of exceedance using the log-log linear ground motion hazard model. The results express at a glance the probabilities of yielding and collapse against various levels of ground motion intensities.