• 제목/요약/키워드: Large steel plate

검색결과 269건 처리시간 0.024초

선체판부재의 2차좌굴거동에 관한 연구 (A Study on the Secondary Buckling Behavior of Ship Plate)

  • 고재용
    • 한국항해학회지
    • /
    • 제20권1호
    • /
    • pp.47-58
    • /
    • 1996
  • The use of high tensile steel plates is increasing in the fabrication of ship and offshore structures. The main portion of ship structure is usually composed of stiffened plates. In these structures, plate buckling is one of the most important design criteria and buckling load may usually be obtained as an eigenvalue solution of the governing equations for the plate. To use the high tensile steel plate effectively, its thickness may become thin so that the occurrence of buckling is inevitable and design allowing plate buckling may be necessary. When the panel elastic buckling is allowed, it is necessary to get precise understandings about the post-buckling behaviour of thin plates. It is well known that a thin flat plate undergoes secondary buckling after initial buckling took place and the deflection of the initial buckling mode was developed. From this point of view, this paper discusses the post-buckling behaviour of thin plates under thrust including the secondary buckling phenomenon. Series of elastic large deflection analyses were performed on rectangular plates with aspect ratio 3.6 using the analytical method and the FEM.

  • PDF

An effective proposal for strength evaluation of steel plates randomly corroded on both sides under uniaxial compression

  • Khedmati, Mohammad Reza;Nouri, Zorareh Hadj Mohammad Esmaeil;Roshanali, Mohammad Mahdi
    • Steel and Composite Structures
    • /
    • 제11권3호
    • /
    • pp.183-205
    • /
    • 2011
  • This paper presents the results of an investigation into the post-buckling behaviour and ultimate strength of imperfect corroded steel plates used in ship and other marine-related structures. A series of elastic-plastic large deflection finite element analyses is performed on randomly corroded steel plates. The effects of general corrosion on both sides of the plates are introduced into the finite element models using a random thickness surface model. The effects on plate compressive strength as a result of parametric variation of the corroded surface geometry are evaluated. A proposal on the effective thickness is concluded in order to estimate the ultimate strength and explore the post-buckling behaviour of randomly corroded steel plates under uniaxial compression.

파형강판벽의 등가 양방향 대각 스트럿 모델을 이용한 기존 건물의 내진성능 평가 (Seismic Performance Evaluation of Existing Buildings Using Equivalent Double Diagonal Strut Model for Corrugated Steel Plate Walls)

  • 이창환;손주기
    • 한국공간구조학회논문집
    • /
    • 제20권1호
    • /
    • pp.87-94
    • /
    • 2020
  • A corrugated steel plate wall (CSPW) system is advantageous to secure the strength and stiffness required for lateral force resistance because of its high out-of-plane stability. It can also stably dissipate large amounts of energy even after peak strength. In this paper, a preliminary study has been carried out to use the CSPW system in the seismic retrofit of existing reinforced concrete (RC) moment frame buildings. The seismic performance for an example building was evaluated, and then a step-by-step retrofit design procedure for the CSPW was proposed. An equivalent analytical model of the CSPW was also introduced for a practical analysis of the retrofitted building, and the strengthening effect was finally evaluated based on the results of nonlinear analysis.

Mode Selection of Leaky Lamb Waves in Steel Plate

  • ;;;나원배
    • 한국해양공학회지
    • /
    • 제22권1호
    • /
    • pp.6-12
    • /
    • 2008
  • The dispersion and attenuation of Lamb and Leaky Lamb waves propagating in a 1 mm-thick steel plate were investigated. For acquiring a long(or large) range inspection capability, the fundamental symmetric and anti-symmetric wave modes(S0 and A0) over law frequencies were studied. Based on the dispersion curves, as well as pitch-catch and multi-mode simulations, it was shown that the S0 mode over law frequencies is the proper mode to minimize the dispersion and attenuation. In addition, it was shown that the S0 mode couldbe easily distinguished under multi-mode simulation since it has a larger group velocity than the A0 mode.

Ultimate load behaviour of tapered steel plate girders

  • Shanmugam, N.E.;Min, Hu
    • Steel and Composite Structures
    • /
    • 제7권6호
    • /
    • pp.469-486
    • /
    • 2007
  • The paper is concerned with the behavior of tapered steel plate girders, primarily subjected to shear loading; experimental as well as finite element results obtained from the studies are presented in this paper. In the experimental study, 11 large-scale girders, one of uniform section and 10 tapered, were tested to failure and all girders were analysed by finite element method. The results are compared and the accuracy of the finite element modeling established. A parametric study was carried out with thickness of web, loading direction and taper angle as parameters. An analytical model, based on Cardiff model for girders of uniform cross-section, is also proposed in the paper.

에폭시 수지 접착 강판보강공법의 환경 변화에 따른 부착 특성 검토 (Investigation on Adhesive Properties depending on the Environmental Variation of the Steel Plate Adhesive Strengthening Method by the Epoxy Resin)

  • 한천구;변항용;박용규
    • 한국건축시공학회지
    • /
    • 제7권3호
    • /
    • pp.107-113
    • /
    • 2007
  • This study is to investigate adhesive properties depending on the temperature, humidity, and freeze-thraw of the Steel plate adhesive strengthening method by the epoxy resin. The results are summarized as following. For the temperature variation, the debonding failure appear only after 1 cycle of temperature varoation because the coefficient of thermal expansion of the epoxy resin is comparatively large, and the bonding strength is decreased. The deformation properties and ultrasonic pulse velocity on each materials are similar until 4 cycles on the dry and moisture test. As the freeze-thraw test, the epoxy resin is degraded easily subjected to freeze-thaw cycle, comparatively easy, so the debonding failure may occur in short term because of the freeze-thaw repeatition.p

극저온 유체 유출현상에 관한 연구 (Experiemtnal Tests of Cryogenic Liuid Spill on a Plate)

  • 류용희;황윤지;이윤한;김광석;이재훈;심희준
    • 플랜트 저널
    • /
    • 제16권3호
    • /
    • pp.42-46
    • /
    • 2020
  • FLNG 혹은 FSRU와 같이 대량의 LNG를 처리하는 공정에서의 LNG 누출 사고 시, 강재의 급격한 온도변화는 구조물의 취성파괴를 야기시킬 가능성이 있다. 본 논문에서는 극저온 유출 실험을 통해 극저온 유체가 강판에 형성되는 원리 및 과정을 알아보고, 노즐로부터의 거리 및 노출시간에 따른 강판의 온도변화의 상관관계를 분석하고자 한다. 극저온 유체는 LN2(비점 -192℃) 및 LNG(비점 -162℃) 두 가지 종류를 사용하였으며, 유출량은 LN2의 경우 1.6L/min 및 LNG 1.5L/min로 강판의 상부에서 분사하였다. 강재는 DH계열 이용하였으며, 총 10 지점에서 온도를 측정하였다. 실험 결과 극저온 유출 초기 강재표면에서 Leidenfrost 효과가 관찰 되었으며, 극저온 유체가 흐르는 경로 및 유체의 증발열에 차이에 따라 강재의 온도분포가 다르게 나타나는 것을 발견하였다.

매입강판 용접열에 의한 고강도 콘크리트 접합부 구조성능 영향평가에 관한 실험적 연구 (Experimental Study for Structural Behavior of Embed Plate into Concrete Subjected to Welding Heat Input)

  • 정경수;김기면;김도환;김진호
    • 한국강구조학회 논문집
    • /
    • 제25권5호
    • /
    • pp.569-578
    • /
    • 2013
  • 초고층 건축물의 RC 코아벽체 선행공법에서는 일반적으로 벽체와 철골보사이의 접합을 위해 강판을 벽체에 매입설치한다. 코어벽체에 설치한 매입강판에 철골보를 접합하기 위해서는 거셋플레이트(또는 단일판)을 사용하여 매입강판에 T-형으로 용접한다. 이에 용접입열에 의해서 매입강판은 열팽창과 용접변형이 발생하고 매입강판 주변 콘크리트 온도상승을 주어 구조적 안정성 평가가 필요하다. 이에, 본 연구에서는 매입강판과 거셋플레이트 사이의 용접자세(수평 및 수직자세), 콘크리트 타설후 용접시점 및 매입강판의 연단거리에 따른 매입강판 배면온도를 계측 하였다. 또한, 비정상 온도해석을 통하여 실험결과와 비교하였다. 다음으로 매입강판에 스터드앵커 접합한 후, Push-out 실험을 통한 구조성능을 조사하였다. 전단실험 결과 매입강판 용접열영향에 대해서 용접에 따른 최대하중은 14~19% 이내로 감소하였으며, 콘크리트 타설 후 용접시점에 따른 영향으로 타설 후 재령이 길수록 최대하중은 상승함을 알 수 있었다.

Rotational behavior of exposed column bases with different base plate thickness

  • Cui, Yao;Wang, Fengzhi;Li, Hao;Yamada, Satoshi
    • Steel and Composite Structures
    • /
    • 제32권4호
    • /
    • pp.497-507
    • /
    • 2019
  • Exposed column base connections are used in low- to mid-rise steel moment resisting frames. This paper is to investigate the effect of the base plate thickness on the exposed column base connection strength, stiffness, and energy dissipation. Five specimens with different base plate thickness were numerically modelled using ABAQUS software. The numerical model is able to reproduce the key characteristics of the experimental response. Based on the numerical analysis, the critical base plate thickness to identify the base plate and anchor rod yield mechanism is proposed. For the connection with base plate yield mechanism, the resisting moment is carried by the flexural bending of the base plate. Yield lines in the base plate on the tension side and compression side are illustrated, respectively. This type of connection exhibits a relatively large energy dissipation. For the connection with anchor rod yield mechanism, the moment is resisted through a combination of bearing stresses of concrete foundation on the compression side and tensile forces in the anchor rods on the tension side. This type of connection exhibits self-centering behavior and shows higher initial stiffness and bending strength. In addition, the methods to predict the moment resistance of the connection with different yield mechanisms are presented. And the evaluated moment resistances agree well with the values obtained from the FEM model.

Experimental study on all-bolted joint in modularized prefabricated steel structure

  • Wu, Zhanjing;Tao, Zhong;Liu, Bei;Zuo, Heng
    • Structural Engineering and Mechanics
    • /
    • 제73권6호
    • /
    • pp.613-620
    • /
    • 2020
  • The research study is focuses on a form of all-bolted joint with the external ring stiffening plate in the prefabricated steel structure. The components are bolted at site after being fabricated in the factory. Six specimens were tested under cyclic loading, and the effects of column axial compression ratio, concrete-filled column, beam flange sub plate, beam web angle cleats, and spliced column on the failure mode, hysteretic behavior and ductility of the joints were analyzed. The results shown that the proposed all-bolted joint with external ring stiffening plate performed high bearing capability, stable inflexibility degradation, high ductility and plump hysteretic curve. The primary failure modes were bucking at beam end, cracking at the variable section of the external ring stiffening plate, and finally welds fracturing between external ring stiffening plate and column wall. The bearing capability of the joints reduced with the axial compression ratio increased. The use of concrete-filled steel tube column can increase the bearing capability of joints. The existence of the beam flange sub plate, and beam web angle cleat improves the energy dissipation, ductility, bearing capacity and original rigidity of the joint, but also increase the stress concentration at the variable section of the external reinforcing ring plate. The proposed joints with spliced column also performed desirable integrity, large bearing capacity, initial stiffness and energy dissipation capacity for engineering application by reasonable design.