• Title/Summary/Keyword: Large shear test

Search Result 482, Processing Time 0.031 seconds

A Study on Shear Capacity and Behavior of Large Sized Concrete Anchorage System (대형 콘크리트 앵커시스템의 전단성능 및 거동특성에 관한 연구)

  • Kim, Kang Sik;Shin, Sung Woo;Lee, Kwang Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.5
    • /
    • pp.82-91
    • /
    • 2011
  • In this study, 24 prototype specimens were tested to find out the shear behavior and strength of large anchorage system exceeding 50mm(2") in anchor bolt diameter($d_0$) and 635mm(25") in effective embedment depth($h_{ef}$) not addressed by ACI349-06 Appendix B. Test variables are anchor bolt diameter($d_0$ = 63.5, 76.2, 88.9mm), effective embedment depth($h_{ef}$=635, 762mm), and edge distance($c_1$=381, 508, 762mm). Concrete compressive strength is constant($f_{ck}$=38MPa). Test results ($V_{test}$) were overestimated by $V_{aci06}$(shear strength by ACI 349-06) and $V_{ccd}$(shear strength by CCD method). In large anchorage system exceeding 50mm(2") of anchor bolt diameter($d_0$) and 635mm(25") of anchor bolt effective embedment depth($h_{ef}$), the bolt diameter variation and effective embedment depth($h_{ef}$) has no influence on the shear strenth, But, according to the analysis results of the feature ratio on edge distance($c_1$) and anchor bolt diameter, the feature ratio become smaller, which means anchor bolt diameter is bigger, predicted ratio of test results and predicted equation is larger. It was found that anchor bolt diameter is immediate cause of deterioration in the shear capacity of large anchorage system. To improve and extend the validity of current design recommendations further theoretical and numerical work is needed.

A Solution to Large Strain Resonant Column and Torsional Shear Tests Apparatus (대변형율 시험을 위한 공진주/비틂전단 시험기의 해결방안)

  • Bae, Yoon-Shin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.3C
    • /
    • pp.103-108
    • /
    • 2011
  • In this study, the limitations of large strain resonant column and torsional shear tests apparatus are described and solutions to the limitations are also described. The limitations are rotational distance, limited torque, and measurable deformation system, respectively. To resolve the rotational distance, the bottom platen was modified. And the four-armed drive plate was modified into eight-armed drive plate and the drive coil connection was changed to obtain powerful torque.

Building of Large Triaxial Testing Apparatus and Static Triaxial Testing for Railway Ballast (대형삼축압축시험장비 구축과 도상자갈의 정적압축시험 평가)

  • Lee, Sung-Jin;Kim, Yun-Ki;Lee, Il-Wha;Lee, Jun-S.;Park, Jae-Jun
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.1
    • /
    • pp.84-91
    • /
    • 2010
  • We built multi-purpose large triaxial testing system that can test and evaluate various geotechnical design parameters such as shear strength, deformation modulus and stress-strain behaviour for large diameter granular materials, which are the most commonly used construction materials in the railway, road embankments. The details of the built testing system and the results obtained from static triaxial test carried out for gneiss ballast material are discussed within the scope of this paper. Ballast is hardly saturated and is confined at low overburden pressure, since the depth is shallow and the permeability is very high. Herein we ascertained that the confining pressure can effectively be controlled by vacuum. The rational trend could be checked up through triaxial test results such as shear strength, deformation, and particle breakage. And the shear strength envelope could be non-linearly represented with the parent rock strength, confining pressure of the triaxial test and proper parameters.

Behavior of Sand during Large Stress Reversal in Torsion Shear Test (비틀림전단시험에 의한 대응력반전시 모래의 거동)

  • 홍원표;남정만
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.4
    • /
    • pp.3-17
    • /
    • 1999
  • Torsion shear tests under various stress paths were performed to study the behavior of sand during large stress reversal. The stress paths can be classified into the clockwise and the counterclockwise according to torque applied to specimen, and the directions of plastic strain incremental on the stress paths including large stress reversal are compared with the direction of stress state and stress incremental. From test results, the isotropic hardening theory using the principle of St. Venant desirably showed that direction of plastic strain incremental coincided with stress state on primary loading part and nearby failure point, but it might result in a rough approximation on part of unloading and reloading by stress reversal.

  • PDF

Analysis of the thresholds of granular mixtures using the discrete element method

  • Jian, Gong;Jun, Liu
    • Geomechanics and Engineering
    • /
    • v.12 no.4
    • /
    • pp.639-655
    • /
    • 2017
  • The binary mixture consists of two types of granular media with different physical attributes and sizes, which can be characterized by the percentage of large granules by weight (P) and the particle size ratio (${\alpha}$). Researchers determine that two thresholds ($P_S$ and $P_L$) exist for the peak shear strength of binary mixtures, i.e., at $P{\leq}P_S$, the peak shear strength is controlled by the small granules; at $P{\leq}P_L$, the peak shear strength is controlled by the large granules; at $P_S{\leq}P{\leq}P_L$, the peak shear strength is governed by both the large and small granules. However, the thresholds of binary mixtures with different ${\alpha}$ values, and the explanation related to the inner details of binary mixtures to account for why these thresholds exist, require further confirmation. This paper considers the mechanical behavior of binary mixtures with DEM analysis. The thresholds of binary mixtures are found to be strongly related to their coordination numbers $Z_L$ for all values of ${\alpha}$, where $Z_L$ denotes the partial coordination number only between the large particles. The arrangement structure of the large particles is examined when P approaches the thresholds, and a similar arrangement structure of large particles is formed in both 2D and 3D particle systems.

The Effect of Water on the Interface Shear Strength between Geosynthetics (물이 토목섬유 사이의 접촉 전단강도에 미치는 영향)

  • 서민우;박준범;박인준
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.321-328
    • /
    • 2002
  • Various geosynthetics used as liners or the Protection layers are installed in the solid waste landfill. The interface shear strength between geosynthetics installed at the slope of the landfill is a very important variable for the safe design of bottom and cover systems in the solid waste landfill. The interface shear strengths between (1) Geomembrane(GM)/Geotexile(GT) and (2) Geomembrane(GM)/Geosynthetic Clay Liner(GCL) were estimated by a large direct shear test in this study and were evaluated by the Mohr-Coulomb failure criterion. Especially, this research is focused on the effect of water which exists between geosynthetics because interfaces become easily wet or hydrated by rain, leachate and groundwater beneath liners. The strength reduction at large displacement and the effects of the magnitude of normal stresses and GCL hydration methods also investigated. The test results showed that the interface shear strength and shear behavior varied depending upon the magnitude of normal stresses, water at the interface, and hydration methods. Summary of secant friction angles, which could be used as reference values at a site where similar geosynthetics are installed, together with normal stress and hydration condition are presented.

  • PDF

Fatigue Behavior of Large Stud Shear Connectors (대직경 스터드 전단연결재의 피로거동)

  • Shim, Chang Su;Lee, Pil Goo;Kim, Hyun Ho;Yoon, Tae Yang
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.6 s.67
    • /
    • pp.621-628
    • /
    • 2003
  • Stud shear connectors are the most commonly used shear connectors: up to 22mm studs are usually used in steel-concrete composite structures. To expand the current design codes for stud connectors, large studs with a diameter of more than 25mm should be investigated. Through push-out tests on large stud shear connectors that transcend the limitation of current design codes, fatigue behavior was investigated and comparisons with design equations performed. The shear stiffness of the connectors in elastic range was evaluated through shear tests on 25mm, 27mm, and 30mm studs and compared with those from static tests. The fatigue behavior of large studs was discussed in terms of residual slip and load-slip curves. The initiation of fatigue cracks in the welding part could be detected through the history of displacement range. Test results showed that the design fatigue endurance of S-N curves in current design codes could be applied to large stud shear connector.

An Experimental Study on the Shear Resistance of Horizontal Joints in Precast Concrete Large Panel Structures (대형판 프리캐스트 콘크리트 구조 수평접합부의 전단내력에 대한 실험적 연구)

  • 정창용;현원창;엄철환;어양석;김상식
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1992.10a
    • /
    • pp.208-213
    • /
    • 1992
  • This research is related to the experimental verification of the shear resistance of horizontal joint in precast concrete large panel structures. a total of 9 spicemens was tested to assess their shear resistance. In the tests lateral forces have been applied to the specimen to cause shear failure while keeping the axial compression consistantly. The shear resistances of the specimens have been evaluated by investigating the deformations and failure modes of the specimens. From the test results, it is observed that the shear resistance of the horizontal joints of P.C panel structures are closely connected with shear friction mechanism.

  • PDF

The Shear Behavior of Composite Material for Retaining Wall (옹벽구조물용 복합재료의 전단거동 특성)

  • Oh, Gi-Dae;Kim, Kyung-Yul;Kim, Dae-Hong
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.1359-1364
    • /
    • 2008
  • In these days, the composite material is popular as a material of Retaining wall because of the advantages of economy and construction. In general, retaining wall is not estimated for the stability of structure, but some of retaining walls that are composed of composite materials became thin because of the highly dense materials. So the concern of shear failure for the structure is rising. Because standard test criterion and large scale tests equipment are rarely available, few studies are performed. So, in this study, we performed large scale direct shear tests for various confining stresses(147, 294, 441 kPa), and estimate shear behavior of composite material by the relation of shear stress - displacement and vertical - shear displacement.

  • PDF

Static Behavior of Large Stud Shear Connectors (대직경 스터드 전단연결재의 정적거동)

  • Lee, Pil Goo;Shim, Chang Su;Yoon, Tae Yang
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.6 s.67
    • /
    • pp.611-620
    • /
    • 2003
  • Shear studs with a diameter of 19mm or 22mm are typically used in steel-concrete composite bridge. For the simplification of details in steel bridges, the convenience of removing concrete slab, and the efficient distribution of shear pockets for precast decks, large studs can be an excellent alternative. Through push-out tests on large stud shear connectors that transcend the limitation of current design codes, static behavior was investigated and comparisons with design equations performed. The shear stiffness of the connectors in elastic range and trilinear load-slip curves were proposed after shear tests on 25mm, 27mm, and 30mm studs. The ultimate slip capacity and ultimate strength of large studs were also evaluated, with the test results revealing conservative values for the design shear strength in Eurocode-4. For 30mm stud shear connectors, the welding quality and bearing capacity of concrete slab should be improved.