• 제목/요약/키워드: Large diameter sampler

검색결과 10건 처리시간 0.024초

KICT-type 대구경 샘플러의 해상 적용성 검토 (Application of KICT-type Large Diameter Sampler for Offshore Ground Sampling)

  • 김영석;김영진;윤여원;정지원
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1365-1369
    • /
    • 2008
  • A large diameter sampler (KICT-type large diameter sampler) was developed to take undisturbed samples from not only soft ground but also sandy and weathered ground. The KICT-type large diameter sampler was manufactured with the principle of triple core barrel sampling. In this study, the applicability to offshore ground sampling of the KICT-type large diameter sampler was confirmed at Inchoen Port construction site. And, in order to compare the quality of samples taken by the sampler with that of the traditional piston sampler, a series of laboratory tests were performed. From the test results, the samples taken by the KICT-type large diameter sampler showed higher quality than the traditional thin-walled tube samples.

  • PDF

대구경 샘플러의 개발 및 채취시료의 성질 분석 (Development of Large Diameter Sampler and Analysis of Sampling Soil Character)

  • 김영진;홍성완;김현민
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.353-360
    • /
    • 2000
  • We developed large diameter sampler (we called KICT type large diameter sampler) to obtain undisturbed clay and sand samples. In-situ test carried out in the In-Chon international airport and Kim-Hae. Also we obtained undisturbed sample with a hydraulic piston sampler in the nearly site and carried out unconfined compression test, consolidation test and triaxial test. The result, unconfined compression strength, secant modules, preconsolidation pressure and undrained shear strength of samples to obtain KICT type large diameter sampler are larger than that of samples to obtain hydraulic piston sampler. But failure strains and volume changes at the consolidation of samples to obtain KICT type large diameter sampler are smaller than that of samples to obtain hydraulic piston sampler

  • PDF

피스톤 샘플러와 대구경 샘플러를 이용한 시료 샘플의 공학적 분석 (Analysis of Soil Samples Obtained from Piston Sampler and Large Diameter Sampler)

  • 김영진;강재모
    • 한국지반환경공학회 논문집
    • /
    • 제9권3호
    • /
    • pp.29-34
    • /
    • 2008
  • 한국건설기술연구원(KICT)에서는 트리플 코어 바렐의 원리를 적용하여 기존의 연약지반 뿐만 아니라 사질토 및 풍화토 지대에도 적용이 기능한 대구경 샘플러를 개발하였다. 특별히 제작된 시료 절단 및 추출 장치는 다양한 종류의 채취 시료에 적용하여 시료의 교란을 최대한 방지 할 수 있도록 고안되었다. 샘플러 두부에는 적절한 강성의 스프링을 설치하여 슈(shoe)와 비트(bit) 사이의 거리가 변화하도록 하여 대상지반의 강성에 맞추어 효과적인 시료채취가 가능하도록 하였다. 대구경 샘플러의 적용성을 확인하기 위하여 일반적으로 시용되는 피스톤 샘플러와 대구 경 샘플러를 이용해 여러 대상지반에서 채취한 시료의 교란도를 비교 분석하였으며, 다양한 공학적 특성 또한 비교 분석 하였다.

  • PDF

대구경 Sampler의 개발 및 적용성에 관한 연구 (A New Development of Large Diameter Sampler and Its Applicability)

  • 한영철
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 가을 학술발표회 논문집
    • /
    • pp.331-336
    • /
    • 1999
  • A great deal of attention has been given in recent years to large diameter specimen for evaluation of soft soil characteristics, and many studies and developments of the apparatus for obtaining large diameter undisturbed soil samples are in progress attempting to minimize the disturbance of samples for precise strength and consolidation tests in the laboratory. This paper introduces a new large diameter sampler(over 300mm diameter), which can take prefectly undisturbed sampling at any depths applying a new sampling technique. By comparing the results of consolidation tests it is shown that the samples obtained by this new apparatus are of a superior quality to that of samples obtained by conventional sampler(Nx, 75mm dia.) at the same depths.

피스톤 샘플러와 대구경 샘플러로 채취한 시료의 특성에 관한 연구 (A Study on the Sample Characteristics Obtained from Large Diameter Sampler and Piston Sampler)

  • 김영진;강재모
    • 한국지반환경공학회 논문집
    • /
    • 제6권3호
    • /
    • pp.5-15
    • /
    • 2005
  • 연약지반에서 비교란 시료를 채취할 수 있는 대구경 샘플러(KICT형 샘플러)를 개발하였다. 이 대구경 샘플러로 채취한 시료와 종래의 피스톤 샘플러로 채취한 시료의 질을 평가하기 위하여 인천, 김해, 양산, 부산에서 각각의 샘플러로 시료를 채취하였으며, 실내에서 일축압축시험, 압밀시험, 삼축압축시험 및 공진주시험을 수행하였다. 그 결과, KICT형 대구경 샘플러로 채취한 시료의 일축압축강도, 할선탄성계수, 선행압밀응력, 비배수전단강도, 전단계수가 수압식 피스톤 샘플러로 채취한 시료의 그것들보다 더 크게 나타났으며, 파괴시 변형률과 압밀시 발생되는 체적변형률은 작게 나타났다.

  • PDF

An analytical investigation of soil disturbance due to sampling penetration

  • Diao, Hongguo;Wu, Yuedong;Liu, Jian;Luo, Ruping
    • Geomechanics and Engineering
    • /
    • 제9권6호
    • /
    • pp.743-755
    • /
    • 2015
  • It is well known that the quality of sample significantly determines the accuracy of soil parameters for laboratory testing. Although sampling disturbance has been studied over the last few decades, the theoretical investigation of soil disturbance due to sampling penetration has been rarely reported. In this paper, an analytical solution for estimating the soil disturbance due to sampling penetration was presented using cavity expansion method. Analytical results in several cases reveal that the soil at different location along the sample centerline experiences distinct phases of strain during the process of sampling penetration. The magnitude of induced strain is dependent on the position of the soil element within the sampler and the sampler geometry expressed as diameter-thickness ratio D/t and length-diameter ratio L/D. Effects of sampler features on soil disturbance were also studied. It is found that the induced maximum strain decreases exponentially with increasing diameter-thickness ratio, indicating that the sampling disturbance will reduce with increasing diameter or decreasing wall thickness of sampler. It is also found that a large length-diameter ratio does not necessarily reduce the disturbance. An optimal length-diameter ratio is suggested for the further design of improved sampler in this study.

Calibration Chamber System을 이용한 KICT-type LPT 장비의 거동분석 (Evaluation of KICT-type Large Penetration Test using Calibration Chamber System)

  • 김영석;김영진;이우진;안신환
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1359-1364
    • /
    • 2008
  • It is well known that the standard penetration test (SPT) has been used in all over the world to get geotechnical properties of the ground. However, it is difficult to apply the SPT to the dense sand, gravel, weathered rock, etc. For the application of the SPT in these grounds, it is necessary to change in the diameter and the impact energy of the SPT. For the improvement of site investigation technology, Large Penetration Testing device (KICT-type LPT) was developed and applied to the in situ condition. The drop height and weight of the hammer in developed system were decided as 760mm and 150kg, respectively. And the developed sampler has the inner diameter of 63 mm and the length of 500 mm with the adjustment of energy ratio to the SPT of 1.5. In this study, the performance of KICT-type LPT was evaluated by using a calibration chamber system and pile driving analyzer (PDA)

  • PDF

한국형 대형관입시험 장비의 개발 및 현장 적용성 평가 (Performance of KICT-type Large Penetration Test (LPT))

  • 김영석;김영진;홍성완;강재모;지완구
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2007년 가을학술발표회
    • /
    • pp.603-610
    • /
    • 2007
  • It is well known that the standard penetration test (SPT) has been used in all over the world to get geotechnical properties of the ground. However, it is difficult to apply the SPT to the dense sand, gravel, weathered rock, etc. For the application of the SPT in these grounds, it is necessary to change in the diameter and the impact energy of the SPT. For the improvement of site investigation technology, Large Penetration Testing device (KICT-type LPT) was developed and applied to the in situ condition. The drop height and weight of the hammer in developed system were decided as 760 mm and 150 kg, respectively. Semi-auto hammer drop system identical with KS F2307 and JI A1259S was adopted. And the developed sampler has the inner diameter of 63 mm and the length of 500 mm with the adjustment of energy ratio to the SPT of 1.5. The hammer energy level was measured during the performance of the KICT-type LPT using SPI system (quality control system from driven piles).

  • PDF

해안지역 대기부유미립자상 물질의 특성에 관한 연구 (A Study on the Characteristics of Ambient Suspended Particulate Matter at Coastal Area, Kangwha)

  • 강공언;우상윤;강병욱;김희강
    • 한국환경보건학회지
    • /
    • 제20권4호
    • /
    • pp.1-9
    • /
    • 1994
  • In order to investigate the regional level of air pollutants at Kangwha island situated on the western coast in Korea, the suspended particulate matter samples were collected by using the low volume air sampler on ten interval from March 1992 to February 1993 and the mass concentration of suspended particulate matter (SPM) and the chemical composition of water-soluble major ionic components in SPM samples were measured. During the sampling period, the average concentration of SPM under diameter 10 $\mu$m was found to be 48 $\mu$g/m$^3$ (+ 12). The seasonal concentration of SPM was showed in order of spring>fall>winter>summer. It was considered that higher concentration on spring than other season was affected by the long-range transport of Yellow sand particulate from China continent and lower concentration on summer by the washout and rainout effect of large rainfall. The content of water-soluble component in SPM samples was founded to be about 31% (14.69 $\mu$g/m$^3$) and 65% was unknown or unanalyzed. The content of cationic component showed in order of NH$_4^+$ (44.6%)>Na$^+$ (21.2%)>K$^+$ (14.7%)>Ca$^{2+}$ (13.6%)>Mg$^{2+}$ (5.9 %) and the content of anionic component SO$_4^{2-}$ (62.5%)>NO$_3^-$ (22.3%)>Cl$^-$ (15.2%), respectively. This fact indicates that ammonium and sulfate ion of water-soluble component in SPM sample were dominant in this region. From the chemical composition of water-soluble component, the most of Na$^+$, Mg$^{2+}$ and Cl$^-$ were originated from seawater source but K$^+$, Ca$^{2+}$ and SO$_4^{2-}$ were originated from other non-marine source. The contribution of seasalt to the composition of precipitation was 23%.

  • PDF

Full validation of high-throughput bioanalytical method for the new drug in plasma by LC-MS/MS and its applicability to toxicokinetic analysis

  • Han, Sang-Beom
    • 한국독성학회:학술대회논문집
    • /
    • 한국독성학회 2006년도 추계학술대회
    • /
    • pp.65-74
    • /
    • 2006
  • Modem drug discovery requires rapid pharmacokinetic evaluation of chemically diverse compounds for early candidate selection. This demands the development of analytical methods that offer high-throughput of samples. Naturally, liquid chromatography / tandem mass spectrometry (LC-MS/MS) is choice of the analytical method because of its superior sensitivity and selectivity. As a result of the short analysis time(typically 3-5min) by LC-MS/MS, sample preparation has become the rate- determining step in the whole analytical cycle. Consequently tremendous efforts are being made to speed up and automate this step. In a typical automated 96-well SPE(solid-phase extraction) procedure, plasma samples are transferred to the 96-well SPE plate, internal standard and aqueous buffer solutions are added and then vacuum is applied using the robotic liquid handling system. It takes only 20-90 min to process 96 samples by automated SPE and the analyst is physically occupied for only approximately 10 min. Recently, the ultra-high flow rate liquid chromatography (turbulent-flow chromatography)has sparked a huge interest for rapid and direct quantitation of drugs in plasma. There is no sample preparation except for sample aliquotting, internal standard addition and centrifugation. This type of analysis is achieved by using a small diameter column with a large particle size(30-5O ${\mu}$m) and a high flow rate, typically between 3-5 ml/min. Silica-based monolithic HPLC columns contain a novel chromatographic support in which the traditional particulate packing has been replaced with a single, continuous network (monolith) of pcrous silica. The main advantage of such a network is decreased backpressure due to macropores (2 ${\mu}$m) throughout the network. This allows high flow rates, and hence fast analyses that are unattainable with traditional particulate columns. The reduction of particle diameter in HPLC results in increased column efficiency. use of small particles (<2 urn), however, requires p.essu.es beyond the traditional 6,000 psi of conventional pumping devices. Instrumental development in recent years has resulted in pumping devices capable of handling the requirements of columns packed with small particles. The staggered parallel HPLC system consists of four fully independent binary HPLC pumps, a modified auto sampler, and a series of switching and selector valves all controlled by a single computer program. The system improves sample throughput without sacrificing chromatographic separation or data quality. Sample throughput can be increased nearly four-fold without requiring significant changes in current analytical procedures. The process of Bioanalytical Method Validation is required by the FDA to assess and verify the performance of a chronlatographic method prior to its application in sample analysis. The validation should address the selectivity, linearity, accuracy, precision and stability of the method. This presentation will provide all overview of the work required to accomplish a full validation and show how a chromatographic method is suitable for toxirokinetic sample analysis. A liquid chromatography/tandem mass spectrometry (LC-MS/MS) method developed to quantitate drug levels in dog plasma will be used as an example of tile process.

  • PDF