• Title/Summary/Keyword: Large defects

Search Result 798, Processing Time 0.03 seconds

Random topological defects in double-walled carbon nanotubes: On characterization and programmable defect-engineering of spatio-mechanical properties

  • A. Roy;K. K. Gupta;S. Dey;T. Mukhopadhyay
    • Advances in nano research
    • /
    • v.16 no.1
    • /
    • pp.91-109
    • /
    • 2024
  • Carbon nanotubes are drawing wide attention of research communities and several industries due to their versatile capabilities covering mechanical and other multi-physical properties. However, owing to extreme operating conditions of the synthesis process of these nanostructures, they are often imposed with certain inevitable structural deformities such as single vacancy and nanopore defects. These random irregularities limit the intended functionalities of carbon nanotubes severely. In this article, we investigate the mechanical behaviour of double-wall carbon nanotubes (DWCNT) under the influence of arbitrarily distributed single vacancy and nanopore defects in the outer wall, inner wall, and both the walls. Large-scale molecular simulations reveal that the nanopore defects have more detrimental effects on the mechanical behaviour of DWCNTs, while the defects in the inner wall of DWCNTs make the nanostructures more vulnerable to withstand high longitudinal deformation. From a different perspective, to exploit the mechanics of damage for achieving defect-induced shape modulation and region-wise deformation control, we have further explored the localized longitudinal and transverse spatial effects of DWCNT by designing the defects for their regional distribution. The comprehensive numerical results of the present study would lead to the characterization of the critical mechanical properties of DWCNTs under the presence of inevitable intrinsic defects along with the aspect of defect-induced spatial modulation of shapes for prospective applications in a range of nanoelectromechanical systems and devices.

Microvascular Reconstruction of the Cranial Base Defects (두개저 결손의 미세수술적 재건술)

  • Minn, Kyung-Won;Kim, In-Chul;Lee, Min-Goo
    • Archives of Reconstructive Microsurgery
    • /
    • v.8 no.1
    • /
    • pp.71-76
    • /
    • 1999
  • Until recently, the cranial base tumors were deemed unresectable due to the inability to diagnose the extent of the involvement accurately and to approach and excise the tumor safely. With refinements in CT and NMR scanning and development of craniofacial techniques, reconstruction becomes absolutely crucial in allowing successful resection of these tumors. Resection of these tumors may sometimes result in massive and complex extirpation defects that are not amendable to local tissue closure. In such cases, the free tissue transfer was a useful alternative because it can provide large amount of well-vascularized tissues and reliable separation of intracranial space from bacterial flora of the upper airway. The microvascular free tissue transfer was used in 9 patients at our center to reconstruct the cranial base defects. Of these, 8 were free rectus muscle flaps, and 1 was free latissimua dorsi muscle flap. There were 1 case of partial flap loss and 1 case of postoperative wound infection. The large, complex defects were successfully reconstructed by one stage operation and the functional and aesthetic results were satisfactory with acceptable complication rates.

  • PDF

Defects evolution and element segregation of Ni-Mo-Cr alloy irradiated by 30 keV Ar ions

  • Liu, Min;Liu, Wenguan;He, Xiujie;Gao, Yantao;Liu, Renduo;Zhou, Xingtai
    • Nuclear Engineering and Technology
    • /
    • v.52 no.8
    • /
    • pp.1749-1755
    • /
    • 2020
  • In present study, TEM foils of Ni-Mo-Cr alloy were directly irradiated with 30 keV Ar ions to allow direct characterization. The defects evolution and element segregation after irradiation were investigated by TEM and HAADF-EDS linear scanning. At low irradiation doses (1.38 and 2.76 dpa), black dots were formed and grew with increasing dose. Complicated defects including peas-shaped dislocation loops, polygon dislocation networks and large loops were visible in samples irradiated to high doses (13.8 and 27.6 dpa). Meanwhile, dislocation channels appeared, in which defects were swept out. Significant Mo depletions at dislocation lines and grain boundaries were induced by irradiation due to large misfits between Mo-Ni atoms and high content of Mo.

MRPC eddy current flaw classification in tubes using deep neural networks

  • Park, Jinhyun;Han, Seong-Jin;Munir, Nauman;Yeom, Yun-Taek;Song, Sung-Jin;Kim, Hak-Joon;Kwon, Se-Gon
    • Nuclear Engineering and Technology
    • /
    • v.51 no.7
    • /
    • pp.1784-1790
    • /
    • 2019
  • Accurate and consistent characterization of defects in steam generator tubes (SGT) in nuclear power plants is one of the key issues in the field of nondestructive testing since the large number of signals to be analyzed in a time-limited in-service inspection causes a serious problem in practice. This paper presents an effective approach to this difficult task of automated classification of motorized rotating pancake coil (MRPC) eddy current flaw acquired from tube specimens with deliberated defects using deep neural networks (DNN). This approach consists of five steps, namely, the data acquisition using the MRPC probe in the tube, the signal preprocessing to make data more suitable for training DNN, the data augmentation for boosting a training performance, the training of DNN, and finally demonstration of the trained DNN for discriminating the axial and circumferential defects. The high performance obtained in this study shows that DNN is useful for classification of defects in tubes from the MRPC eddy current signals even though the number of signals is very large.

Reconstruction of a Severe Open Tibiofibular Fracture using an Ipsilateral Vascularized Fractured Fibula with a Thoracodorsal Artery Perforator Free Flap

  • Lan Sook Chang;Dae Kwan Kim;Ji Ah Park;Kyu Tae Hwang;Youn Hwan Kim
    • Archives of Plastic Surgery
    • /
    • v.50 no.5
    • /
    • pp.523-528
    • /
    • 2023
  • The Gustilo IIIB tibiofibular fractures often result in long bone loss and extensive soft tissue defects. Reconstruction of these complex wounds is very challenging, especially when it includes long bone grafts, because the donor site is limited. We describe our experience using a set of chimeric ipsilateral vascularized fibula grafts with a thoracodorsal artery perforator free flap to reconstruct the traumatic tibia defects. A 66-year-old male suffered a severe comminuted tibia fracture and segmented fibula fracture with large soft tissue defects as a result of a traffic accident. He also had an open calcaneal fracture with soft tissue defects on the ipsilateral side. All the main vessels of the lower extremity were intact, and the cortical bone defect of the tibia was almost as large as the fractured fibula segment. We used an ipsilateral vascularized fibula graft to reconstruct the tibia and a thoracodorsal artery perforator flap to resurface the soft tissue, using the distal ends of peroneal vessels as named into sequential chimeric flaps. After 3 weeks, the calcaneal defect was reconstructed with second thoracodorsal artery perforator free flap. Reconstruction was successful and allowed rapid rehabilitation because of reduced donor site morbidity.

Ring-Rolling Design of a Large-Scale Ti-6Al-4V alloy (대형 Ti-6Al-4V 합금의 Ring-Rolling 공정설계)

  • Yeom, J.T.;Jung, E.J.;Kim, J.H.;Lee, D.G.;Park, N.K.;Choi, S.S.;Lee, C.S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2006.05a
    • /
    • pp.373-376
    • /
    • 2006
  • The ring rolling design for a large-scale Ti-6Al-4V alloy ring was performed with a calculation method and FEM simulation. The ring rolling design includes geometry design and optimization of process variables. The calculation method was to determine geometry design such as initial billet and blank size, and final rolled ring shape. A commercial FEM code, SHAPE was used to simulate the effect of process variables in ring rolling on the distribution of the internal state variables such as strain, strain rate and temperature. In order to predict the forming defects during ring rolling, the process-map approach based on Ziegler's instability criterion was used with FEM simulation. Finally, an optimum process design to obtain sound Ti-6Al-4V rings without forming defects was suggested through combined approach of Ziegler's instability map and FEM simulation results.

  • PDF

Process Design for Large-Scale Ring-Rolling of Ti-6Al-4V Alloy (Ti-6Al-4V 합금의 대형 링 압연공정설계)

  • Yeom, J.T.;Kim, J.H.;Lee, D.G.;Park, N.K.;Choi, S.S.;Lee, C.S.
    • Transactions of Materials Processing
    • /
    • v.16 no.3 s.93
    • /
    • pp.172-177
    • /
    • 2007
  • The process design for large-scale ring rolling of Ti-6Al-4V alloy was performed by calculation method, processing map approach and FEM simulation. The ring rolling design includes geometry design and optimization of process variables. The calculation method was used to make geometry design such as initial billet and blank sizes, and final rolled ring shape. A commercial FEM code, SHAPE-RR was used to simulate the effect of process variables in ring rolling on the distribution of the internal state variables such as strain, strain rate and temperature. In order to predict the forming defects during ring rolling and the formation of over-heating above $\beta$-transus temperature due to deformation heating, the process-map approach based on Ziegler's instability criterion was used with FEM simulation. Finally, an optimum process design to obtain sound Ti-6Al-4V rings without forming defects was suggested through combined approach of Ziegler's instability map and FEM simulation results.

The Effects of Stress Fields on Behavior of Primary Cracks Initiated at Micro Surface Defects (미소 표면 결함에서 발생하는 초기 균열의 거동에 미치는 응력장의 영향)

  • 김진봉;김만근
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.3
    • /
    • pp.25-32
    • /
    • 1999
  • This study has been performed to investigate the stress distribution around defects that behave as stress concentrators. Besides, the effect of stress interaction effects on the initiation of primary cracks were also investigated by rotary bending fatigue tests which were performed with specimens drilled micro surface defects and the stress distribution was analyzed using Finite Element Method. In addition, the stress interaction effects around defects and cracks were investigated by comparing the results of experiments and F.E.M. The results obtained are summarized as follows ; 1) Area which slip and micro cracks initiated at micro surface defects is between the maximum shear stress points and this area is over than ${\pm}30^{\circ}$ from the maximum stress point along the defect edge. 2) The stress interaction effect for the small size defect is larger than that of large size defect when the interval between them is near 3) Interval which there is no shear stress interaction effect analyzed by F.E.M. is larger than that of experimental results.

  • PDF

Study on Experimental Selection of Parameters in Laser Scattering Mechanism and Analysis of Laser Scattering Patterns in Solar Cell Wafer (레이저 산란 메커니즘 매개변수의 실험적 선정 및 태양전지 웨이퍼의 레이저산란패턴 분석에 관한 연구)

  • Kim, Gyung-Bum
    • Journal of the Semiconductor & Display Technology
    • /
    • v.10 no.2
    • /
    • pp.7-12
    • /
    • 2011
  • In this paper, a laser scattering mechanism are designed to detect micro defects such as dent, scratch, pinhole, etc. Its influential parameters are experimentally selected and scattering patterns of micro defects have been analyzed for silicon wafer in solar cell. As a result of experiments, scattered lights are rather increased in wafer surface with micro defects, in comparison to no micro ones. Scattering parameters are optimally selected for obtaining robust and high quality laser scattering images of micro defects. It is shown that scattered light components are linearly increased according to the increase of micro defect sizes, and the depth of micro-defects give a large influence on optical deflection.

Reconstruction of Metaphyseal Defect of Large Long Tubular Bone with Double Barreled Fibular Graft (중첩한 비골 이식술을 이용한 대형 장골의 골 간단부 결손의 재건)

  • Chung, Duke-Whan;Park, Jun-Young
    • Archives of Reconstructive Microsurgery
    • /
    • v.14 no.1
    • /
    • pp.50-56
    • /
    • 2005
  • There are limited treatment options in the reconstruction of the very large defect in the metaphyseal portion of distal femur and proximal tibia. Fibula is one of the most popular donor of the long bone reconstruction in reconstructive microsurgical field. It has many advantages such as very strong strut tubular bone, very reliable vascular anatomy with large vascular diameter and long pedicle. There are limited donor site problems such as transient peroneal nerve dysfunction. In those situations with the huge long bone defects in distal femur or proximal tibia, the defective bony shape and strength of the transplanted fibular bone is not enough if only one strut of the fibula is transferred. We performed 7 cases of "doule barrel" fibular transplantation on the metaphyseal portion of distal femur and proximal tibial large defects in which it is very difficult to fill the bony gap with conventional bone graft or callotasis methods. It takes averaged 8.3 months since that procedure to obtain bony union. After solid union of the transferred double barrelled fibular graft. There were no stress fracture in our series. So we can propose double barrel fibular graft is useful method in those cases with very large bone defect on the metaphysis of large long bone.

  • PDF