• Title/Summary/Keyword: Large chamber

Search Result 565, Processing Time 0.03 seconds

Fabrication of Pentacene Thin Film Transistors by using Organic Vapor Phase Deposition System (Organic Vapor Phase Deposition 방식을 이용한 펜타센 유기박막트랜지스터의 제작)

  • Jung Bo-Chul;Song Chung-Kun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.6
    • /
    • pp.512-518
    • /
    • 2006
  • In this paper, we investigated the deposition of pentacene thin film on a large area substrate by Organic Vapor Phase Deposition(OVPD) and applied it to fabrication of Organic Thin Film Transistor(OTFT). We extracted the optimum deposition conditions such as evaporation temperature of $260^{\circ}C$, carrier gas flow rate of 10 sccm and chamber vacuum pressure of 0.1 torr. We fabricated 72 OTFTs on the 4 inch size Si Wafer, Which produced the average mobility of $0.1{\pm}0.021cm^2/V{\cdot}s$, average subthreshold slope of 1.04 dec/V, average threshold voltage of -6.55 V, and off-state current is $0.973pA/{\mu}m$. The overall performance of pentacene TFTs over 4 ' wafer exhibited the uniformity with the variation less than 20 %. This proves that OVPD is a suitable methode for the deposition of organic thin film over a large area substrate.

The Nature of the Tomb Form and the Group Tomb Complex of the Wooden Chamber Tombs with Stone Mound in the Early Silla Phase (신라 전기 적석목곽분의 묘형과 집단복합묘군의 성격)

  • Choi, Byung-Hyun
    • Korean Journal of Heritage: History & Science
    • /
    • v.50 no.4
    • /
    • pp.168-197
    • /
    • 2017
  • This paper considers two aspects of the wooden chamber tombs with stone mound that were constructed in Wolseong North Burial Ground, in Gyeongju: tomb form and the group tomb complex. The basic unit of a wooden chamber tomb with stone mound consisted of a single round mound, covered with an additional earthen layer and surrounded by a circle of protective stones, within which a single wooden chamber was located. The form of a wooden chamber tomb with stone mound could therefore 1) be round, consisting of a single tomb unit, 2) consist of two or more attached tomb units, 3) or consist of multiple attached chambers in a single mound. The single tomb contained the burial of a single individual, and the attached tomb contained two or more individuals who were blood relations or connected by marriage. Multiple attached chambers tombs usually consisted of wooden chamber burials of the lowest rank, and have only been identified in the royal burial area of Wolseong North Burial Ground. At the Jjoksaem Area of Wolseong North Burial Ground, which is currently, under investigation, tombs have been found in small clusters along the slightly raised ground. This is likely the result of small groups of kin relations, upon selecting points along the slightly raised ground as their burial area, having constructed midsized and large single tombs and attached tombs along the axis of the slightly raised ground, which were then surrounded by smaller 'satellite' tombs. It is through this process that the tomb complex of the different groups came to be formed. The tombs of the royal burial area of Wolseong North Burial Ground, including the Daereungwon Tomb Complex, also formed group tomb complexes. Forming the centers of the group tomb complexes of the royal tomb area were huge individual round tombs where the Maripgan rulers were laid to rest or a gourd-shaped dual mound tomb, which was the final resting place of the king and his queen consort. These central tombs were surrounded by large and smaller tombs. Of the individuals that were buried in the group tomb complexes, there would have been individuals that were of equal status or social position, such as husbands and wives or blood relations, but it is unlikely that all of the buried individuals were related by blood, given the significant difference in the sizes of the tombs. It is likely that the individuals buried in the lower ranked tombs included in the group tomb complexes were 'dependents' of the deceased of the central tomb and his or her direct family who maintained a subservient relationship. Such tomb forms and group tomb complexes that can be observed amongst the wooden chamber tombs with stone mounds of Wolseong North Burial Ground provide insights into the nature of the social groups of the Silla center during the Maripgan Period. It is hoped that future studies undertaking a more detailed analysis of the data may make further contributions to unveiling the various aspects of Silla society.

Combustion Characteristics of Landfill Gas in Constant Volume Combustion Chamber for Large Displacement Volume Engine (IV) -Torch Ignition (2) - (대형기관 모사 정적연소실에서 매립지 가스의 연소특성에 대한 연구 (IV) -토치 점화 (2)-)

  • Ko, Ansu;Ohm, Inyong;Kwon, Soon Tae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.2
    • /
    • pp.135-146
    • /
    • 2015
  • This paper is the fourth on the combustion characteristics of the landfill gas in a constant volume combustion chamber for a large displacement volume commercial engine and the second dealing with torch ignition. It discusses the combustion characteristics of torch ignition on the basis of the heat release and visualization. The results show that the jet and/or spout from the torch promote combustion by accelerating the flame front in the main combustion chamber. In addition, a hot gas jet exists when the orifice diameter is 4 mm, whereas the flame passes directly through the orifice if the diameter is 6 mm or greater. In addition, the effect of torch ignition differs according to the combination of the methane fraction, torch volume, and orifice size because various combustion processes occur as a result of the interaction of these parameters. Finally, it was found that the most suitable torch should have an orifice diameter of not less than 6 mm and an area ratio of not more than 0.15 to secure a consistent combustion process in a real engine.

Comparison of automatic and manual chamber methods for measuring soil respiration in a temperate broad-leaved forest

  • Lee, Jae-Seok
    • Journal of Ecology and Environment
    • /
    • v.42 no.4
    • /
    • pp.272-277
    • /
    • 2018
  • Background: Studying the ecosystem carbon cycle requires analysis of interrelationships between soil respiration (Rs) and the environment to evaluate the balance. Various methods and instruments have been used to measure Rs. The closed chamber method, which is currently widely used to determine Rs, creates a closed space on the soil surface, measures $CO_2$ concentration in the inner space, and calculates Rs from the increase. Accordingly, the method is divided into automatic or manual chamber methods (ACM and MCM, respectively). However, errors of these methods and differences in instruments are unclear. Therefore, we evaluated the characteristics and difference of Rs values calculated using both methods with actual data. Results: Both methods determined seasonal variation patterns of Rs, reflecting overall changes in soil temperature (Ts). ACM clearly showed detailed changes in Rs, but MCM did not, because such small changes are unknown as Rs values are collected monthly. Additionally, Rs measured using MCM was higher than that using ACM and differed depending on measured plots, but showed similar tendencies with all measurement times and plots. Contrastingly, MCM Rs values in August for plot 4 were very high compared with ACM Rs values because of soil disturbances that easily occur during MCM measurements. Comparing Rs values calculated using monthly means with those calculated using MCM, the ACM calculated values for monthly averages were higher or lower than those of similar measurement times using the MCM. The difference between the ACM and MCM was attributed to greater or lesser differences. These Rs values estimated the carbon released into the atmosphere during measurement periods to be approximately 57% higher with MCM than with ACM, at 5.1 and $7.9C\;ton\;ha^{-1}$, respectively. Conclusion: ACM calculated average values based on various Rs values as high and low for measurement periods, but the MCM produced only specific values for measurement times as representative values. Therefore, MCM may exhibit large errors in selection differences during Rs measurements. Therefore, to reduce this error using MCM, the time and frequency of measurement should be set to obtain Rs under various environmental conditions. Contrastingly, the MCM measurement is obtained during $CO_2$ evaluation in the soil owing to soil disturbance caused by measuring equipment, so close attention should be paid to measurements. This is because the measurement process is disturbed by high $CO_2$ soil concentration, and even small soil disturbances could release high levels into the chamber, causing large Rs errors. Therefore, the MCM should be adequately mastered before using the device to measure Rs.

Effect on Corrosion Characteristics of SS 400 Steel by Alkali Water pH from Electrolysis of City Water (수돗물의 전기분해에 의해서 생성된 알카리수의 pH가 SS 400강의 부식특성에 미치는 영향)

  • Moon, Kyung-Man;Ryoo, Hae-Jeon;Kim, Yun-Hae;Jeong, Jae-Hyun;Baek, Tae-Sil
    • Journal of Ocean Engineering and Technology
    • /
    • v.31 no.3
    • /
    • pp.248-255
    • /
    • 2017
  • Many rivers and seas have been affected by environmental contamination. Therefore, city water supplies often require a high-degree purification treatment to provide safe drinking water. However, in order to achieve a high-degree purification treatment, a large amount of chlorine has to be added to sterilize city drinking water. The added chlorine reacts chemically with water and forms hypochlorous and chlorine ions. The hypochlorous ionizes with hypochlorous ions and hydrogen ions. As a result, the city water contains a large amount of chlorine ion. As such, when city water is used with domestic boilers, many kinds of heat exchangers, and the engines of vehicle and ships, there are often corrosion problems. In this study, alkali water was electrochemically made by electrolysis of city water, and corrosion properties between alkali and city water were investigated with an electrochemical method. Most of the chlorine ions are thought to not be contained in the alkali water because the alkali water is created in the cathodic chamber with an electrolysis process. In other words, the chlorine ion can be mostly removed by its migration from a cathodic chamber to an anodic chamber. Moreover, the alkali water also contains a large amount of hydroxide ion. The alkali water indicated relatively good corrosion resistance compared to the city water and the city water exhibited a local corrosion pattern due to the chlorine ion created by a high-degree purification treatment. In contrast, the alkali water showed a general corrosion pattern. Consequently, alkali water can be used with cooling water to inhibit local corrosion by chlorine ions in domestic boilers, various heat exchangers and the engine of ships and for structural steel in a marine structure.

Comparison and Optimization of Flux Chamber Methods of Methane Emissions from Landfill Surface Area (매립지 표면의 메탄 발산량 실측을 위한 플럭스 챔버의 방법론적 비교와 최적화)

  • Jeong, Jin Hee;Kang, Su Ji;Lim, Jong Myoung;Lee, Jin-Hong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.10
    • /
    • pp.535-542
    • /
    • 2016
  • As one of the most cost-effective methods for surface emission measurements, flux chamber method has been used worldwide. It can be classified into two types: SFC (with slope method) and DFC (with steady-state method). SFC (static flux chamber) type needs only simple equipment and is easy to handle. However, the value of flux might vary with SFC method, because it assumes that the change of concentration in chamber is linear with time. Although more specific equipments are required for DFC (dynamic flux chamber) method, it can lead to a constant result without any ambiguity. We made a self-designed DFC using a small and compact kit, which recorded good sample homogeneity (RSD < 5%) and recovery ( > 90%). Relative expanded measurement uncertainty of this improved DFC method was 7.37%, which mainly came from uncontrolled sweep air. The study shows that the improved DFC method can be used to collect highly reliable emission data from large landfill area.

Pneumatic Separation on Separating Unit of a Combine Harvester (콤바인 선별실(選別室)의 기류선별(氣流選別)에 관한 연구(硏究))

  • Chung, C.J.;Nam, S.I.;Joo, B.C.
    • Journal of Biosystems Engineering
    • /
    • v.13 no.3
    • /
    • pp.32-43
    • /
    • 1988
  • This study was attempted to investigate the pneumatic separation on separating unit of a combine harvester. The aerodynamic characteristics of threshed materials were analyzed by experiments. The air velocity distribution within the separation chamber was measured for various speeds of the winnower and suction fans to find out the operational and design conditions of the separating unit which would serve for reducing the grain loss from chaff outlet. The results of study arc summarized as follows: 1. Based on the separation curve of threshed materials analyzed, it was shown that three different kind. of materials-kernels, straw chaff, and leaf chaff were as a whole able to be separated pneumatically, regardless of varieties. However, a small amount of the separation grain loss may be expected to occur if the complete separation between kernels and straw chaff would be undertaken because some portion of their separation curve were overlapping. 2. The analysis of air velocity distribution showed that the separation chamber may be divided into two regions, the discharging and separating. The air velocity of the discharging region was 5-15 m/s and that of the separating region 2-5 m/s. 3. The air movement of the separation chamber may be a turbulence flow, being its speed became greater as it moves from the left to the right section of the separation chamber. The equi-speed line. of air flow had a steep gradient in between the discharging and the separation regions. The air velocity in the discharging region was much higher than the terminal velocity of kernels, because of which those kernels appearing in the region could be possibly exhausted as the grain loss from the chaff outlet. 4. The motion trajectory of threshed material in the separating region was dominantly affected by the winnower fan, on the other hand, its motion in the discharging region was affected by suction fan. 5. The grain loss from the chaff outlet was affected greatly by the winnower fan and the trace of kernel movement. It was observed that the optimum working speed to give minimum grain loss from chaff outlet for the combine tested should be maintained at 950~1,150 rpm for the winnower fan and 1,850 rpm for the suction fan. 6. It was shown that a large portion of grain loss from chaff outlet may occur when the kernels may bump against a portion of separation chamber wall and those kernels thus scattered into the discharging region were sucked by the suction fan. It was accordingly recommended that a new design of the wall of separation chamber so as to bump down kernels may be necessary to reduce grain loss from the chaff outlet.

  • PDF

Computational Analysis on Effect of Ambient Swirling Flow on Combustion and Flame Development in Coal Burner Flames (석탄 연소로에서 버너주위 선회유동이 연소 및 화염발달에 미치는 영향에 관한 수치적 연구)

  • Lee, Hookyung;Choi, Sangmin
    • 한국연소학회:학술대회논문집
    • /
    • 2012.11a
    • /
    • pp.15-16
    • /
    • 2012
  • The present study aims to investigate quantitatively the hydrodynamic effect on combustion process of pulverized coal particles in large scale combustion chamber using computational analysis, with a general purpose computational fluid dynamics code. Burner hydrodynamics include swirl and turbulence intensity from the burner. To understand the phenomena which are difficult to observe how flow has influence on the combustion process, comparative effect of combustion related coal properties and hydrodynamics is evaluated on flame formation and development in burner flames.

  • PDF

An Experimental Assessment of Combustion Stability of Coaxial Swirl Injectors and an Impinging Injector through Simulating Combustion Test (상압기상연소시험을 통한 동축형 스월 분사기와 충돌형 분사기의 연소 안정성 평가)

  • Park, Junhyeong;Kim, Hongjip
    • Journal of the Korean Society of Combustion
    • /
    • v.22 no.1
    • /
    • pp.46-52
    • /
    • 2017
  • High-frequency combustion instabilities may occur during the development of feasible engine combustors. These instabilities can result in irreparable damages to the wall of combustors or the degradation of engine performance. So, it is essential to identify injectors that have high stability characteristics during the early stages of development. The objective of present study was to assess the stability of coaxial injectors and an impinging injector with different recess lengths in order to develop stable injectors optimally. Stability margin was evaluated based on the distance from operating condition to the unstable regions. A simulating combustion test method was used to analyze the stability of injectors. A small-scale combustion chamber was designed to simulate the first tangential acoustic mode of the actual combustor. Gaseous oxygen and a mixture of methane and propane were used as simulant propellants to satisfy their flow similarity to the actual propellants of a combustor in a liquid rocket combustor. The results indicated that injectors having small recess lengths showed relatively large combustion stability margins. For the injectors of large recess lengths, instability regions with large and super-large amplitude oscillations were observed. Thus, injector with shorter recess lengths had a higher stability than that of longer one due to the different mixing processes.