• Title/Summary/Keyword: Laparoscopic hepatectomy

Search Result 6, Processing Time 0.029 seconds

Total robotic right hepatectomy for multifocal hepatocellular carcinoma using vessel sealer

  • Peeyush Varshney;Vaibhav Kumar Varshney
    • Annals of Hepato-Biliary-Pancreatic Surgery
    • /
    • v.27 no.1
    • /
    • pp.95-101
    • /
    • 2023
  • Rapid adoption of a robotic approach as a minimally invasive surgery tool has enabled surgeons to perform more complex hepatobiliary surgeries than conventional laparoscopic surgery. Although various types of liver resections have been performed robotically, parenchymal transection is challenging as commonly used instruments (Cavitron Ultrasonic Surgical Aspirator [CUSA] and Harmonic) lack articulation. Further, CUSA also requires a patient-side assistant surgeon with hepatobiliary laparoscopic skills. We present a case report of total robotic right hepatectomy for multifocal hepatocellular carcinoma in a 70-year-old male using 'Vessel Sealer' for parenchymal transection. Total operative time was 520 minutes with a blood loss of ~400 mL. There was no technical difficulty or instrument failure encountered during surgery. The patient was discharged on postoperative day five without any significant complications such as bile leak. Thus, Vessel Sealer, a fully articulating instrument intended to seal vessels and tissues up to 7 mm, can be a promising tool for parenchymal transection in a robotic surgery.

Learning Laparoscopic Liver Resection for Liver Cancer

  • Tan To Cheung
    • Journal of Digestive Cancer Research
    • /
    • v.5 no.1
    • /
    • pp.28-31
    • /
    • 2017
  • The number of laparosocpic liver resection performed every years has been increasing. There is a trend than more major hepatectomy and complex liver resection is being reported. However there has been a major obstacles in many centers because open liver resection is still considered as a gold standard and many surgeons are still getting used to the old method of liver resection. To start a new procedure, education and training is essential in order to achieve a good outcome without compromising the safety of the patients. A gradual progression is crucial in order to avoid dreadful complication. The development of the consensus meeting and difficulty score has facility the understanding of safe practice in the development of laparoscopic liver resection. In a long run, development of registry system will improve transparency and safety of this operation.

  • PDF

The Pringle maneuver in the modern era: A review of techniques for hepatic inflow occlusion in minimally invasive liver resection

  • Omar A. Mownah;Somaiah Aroori
    • Annals of Hepato-Biliary-Pancreatic Surgery
    • /
    • v.27 no.2
    • /
    • pp.131-140
    • /
    • 2023
  • During minimally invasive liver resection (MILR), the Pringle maneuver aims to minimize blood loss and provide a clear operative field, thereby identifying intrahepatic structures and facilitating safe parenchymal transection. Several techniques for using the Pringle maneuver in MILR have been described. This review presents various methods which have been reported in the literature. A systematic literature search used the MEDLINE/PubMed database from its earliest records to August 2022 using appropriate search headings and keywords. The primary outcome was identifying techniques for performing hepatic inflow occlusion during laparoscopic/robotic hepatectomy. Inclusion criteria consisted of publications describing technical steps to obtain hepatic inflow occlusion during minimally invasive hepatectomy. A literature search identified 23 relevant publications, and the full texts were examined. The techniques described in the reports can be broadly categorized into three groups: (1) the Rummel-tourniquet technique, (2) vascular clamp use, and (3) the Huang Loop technique. Various techniques have been used in MILR to achieve inflow confinement successfully. The authors prefer the modified Huang Loop technique because it is inexpensive, reliable, and quick to apply or release. Hepatobiliary surgeons are advised to familiarize themselves with these MILR techniques, which have proven effective and safe inflow occlusion.

Low versus standard central venous pressure during laparoscopic liver resection: A systematic review, meta-analysis and trial sequential analysis

  • Mina Stephanos;Christopher M. B. Stewart;Ameen Mahmood;Christopher Brown;Shahin Hajibandeh;Shahab Hajibandeh;Thomas Satyadas
    • Annals of Hepato-Biliary-Pancreatic Surgery
    • /
    • v.28 no.2
    • /
    • pp.115-124
    • /
    • 2024
  • To compare the outcomes of low central venous pressure (CVP) to standard CVP during laparoscopic liver resection. The study design was a systematic review following the PRISMA statement standards. The available literature was searched to identify all studies comparing low CVP with standard CVP in patients undergoing laparoscopic liver resection. The outcomes included intraoperative blood loss (primary outcome), need for blood transfusion, mean arterial pressure, operative time, Pringle time, and total complications. Random-effects modelling was applied for analyses. Type I and type II errors were assessed by trial sequential analysis (TSA). A total of 8 studies including 682 patients were included (low CVP group, 342; standard CVP group, 340). Low CVP reduced intraoperative blood loss during laparoscopic liver resection (mean difference [MD], -193.49 mL; 95% confidence interval [CI], -339.86 to -47.12; p = 0.01). However, low CVP did not have any effect on blood transfusion requirement (odds ratio [OR], 0.54; 95% CI, 0.28-1.03; p = 0.06), mean arterial pressure (MD, -1.55 mm Hg; 95% CI, -3.85-0.75; p = 0.19), Pringle time (MD, -0.99 minutes; 95% CI, -5.82-3.84; p = 0.69), operative time (MD, -16.38 minutes; 95% CI, -36.68-3.39; p = 0.11), or total complications (OR, 1.92; 95% CI, 0.97-3.80; p = 0.06). TSA suggested that the meta-analysis for the primary outcome was not subject to type I or II errors. Low CVP may reduce intraoperative blood loss during laparoscopic liver resection (moderate certainty); however, this may not translate into shorter operative time, shorter Pringle time, or less need for blood transfusion. Randomized controlled trials with larger sample sizes will provide more robust evidence.

Donor Complication in Living Donor Liver Transplantation (생체간이식에 관한 공여자 합병증)

  • Yang, Jae Do;Yu, Hee Chul
    • Korean Journal of Transplantation
    • /
    • v.31 no.4
    • /
    • pp.177-181
    • /
    • 2017
  • Living donor liver transplantation (LDLT) has become an inevitable procedure due a shortage of deceased donors under the influence of religious and native cultures. The most important concern in LDLT is donor safety. This study reviewed the safety of LDLT donors from reported studies of morbidity and mortality. Many studies have reported mortality and morbidity rates ranging from 0% to 33% for healthy liver donors. Use of laparoscopic surgery on LDLT donors has advantages of reduced blood loss, lower postoperative morbidity and shorter hospital stay relative to conventional open surgery. There is a consensus that remnant liver volume (RLV), degree of steatosis, and donor age are the most important factors influencing donor safety. In LDLT, donor hepatectomy can be performed successfully with minimal and easily controlled complications. However, a large-scale prospective cohort study is needed to better understand the risk factors and accurately determine the complication rates for LDLT.

Procedural outcomes of laparoscopic caudate lobe resection: A systematic review and meta-analysis

  • Shahab Hajibandeh;Ahmed Kotb;Louis Evans;Emily Sams;Andrew Naguib;Shahin Hajibandeh;Thomas Satyadas
    • Annals of Hepato-Biliary-Pancreatic Surgery
    • /
    • v.27 no.1
    • /
    • pp.6-19
    • /
    • 2023
  • A systematic review was conducted in compliance with PRISMA statement standards to identify all studies reporting outcomes of laparoscopic resection of benign or malignant lesions located in caudate lobe of liver. Pooled outcome data were calculated using random-effects models. A total of 196 patients from 12 studies were included. Mean operative time, volume of intraoperative blood loss, and length of hospital stay were 225 minutes (95% confidence interval [CI], 181-269 minutes), 134 mL (95% CI, 85-184 mL), and 7 days (95% CI, 5-9 days), respectively. The pooled risk of need for intraoperative transfusion was 2% (95% CI, 0%-5%). It was 3% (95% CI, 1%-6%) for conversion to open surgery, 6% (95% CI, 0%-19%) for need for intra-abdominal drain, 1% (95% CI, 0%-3%) for postoperative mortality, 2% (95% CI, 0%-4%) for biliary leakage, 2% (95% CI, 0%-4%) for intra-abdominal abscess, 1% (95% CI, 0%-4%) for biliary stenosis, 1% (95% CI, 0%-3%) for postoperative bleeding, 1% (95% CI, 0%-4%) for pancreatic fistula, 2% (95% CI, 1%-5%) for pulmonary complications, 1% (95% CI, 0%-4%) for paralytic ileus, and 1% (95% CI, 0%-4%) for need for reoperation. Although the available evidence is limited, the findings of the current study might be utilized for hypothesis synthesis in future studies. They can be used to inform surgeons and patients about estimated risks of perioperative complications until a higher level of evidence is available.