• Title/Summary/Keyword: Langelier index(LI)

Search Result 16, Processing Time 0.018 seconds

Corrosivity Characteristics of Raw Water in Korea (국내 상수원수의 부식성 특성)

  • Kim, Jin-Keun;Kim, Jae-Won
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.6
    • /
    • pp.839-846
    • /
    • 2011
  • To investigate corrosivity characteristics of raw water in Korea, Langelier index (LI) of 30 multi-regional water treatment plants (WTPs) were evaluated. Annual average values of LI at 30 WTPs were all negative, which means raw water in Korea is very corrosive. LI results for 4 major rivers showed that raw water from Han and Nakdong had relatively high values compared to those of Sumjin and Keum. On the other hand, LI values of raw water from the tributaries of four major rivers were relatively low presumably due to geological characteristics, and in some cases the values were less than -4.0 which means increase of LI is urgently needed to minimize red water problem. Based on the correlation results among LI and water quality parameters, pH, water temperature, calcium concentration were confirmed as major components for LI. Therefore, pH and calcium concentration control is an effective method for the improvement of LI in water treatment processes.

Introduction of Corrosion Index System for Stability of Drinking Water Quality (음용수질의 안정성을 위한 부식지수제도의 도입)

  • Kim, Yeong-Kwan;Kim, Jin-Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.5
    • /
    • pp.707-717
    • /
    • 2011
  • Replacement of old water distribution pipes for protecting water quality induced by pipe corrosion requires enormous budget. Even after the replacement, however, corrosion can occur again at any times and, therefore, inhibitive measure of the corrosion will be not only economical but needed to diminish the consumers' distrust on tap water quality. In 2008, National Environmental Research Institute did a survey on 8 major drinking water source and proposed to establish the Langelier Saturation Index(LI) as a corrosion index in Drinking Water Quality Criteria. Among the water industries of Korea, K-Water is the only one that set up the level of pH over 7.0 and LI above -1.5 on yearly average basis. However, no systematic regulation including LI to inhibit the corrosive tendency has been established yet. In this paper, LI values out of 31 drinking water treatment plants were analyzed and two-stage control of LI value as a measure of corrosive tendency of water is proposed. Primarily, water treatment facilities may operate the system at a target LI value below -1.5. Following the investigation on the effect caused by adjusting the LI value on water quality and corrosiveness, it will be desirable to improve LI value below -1.0 in the long run. In addition to the LI, supplemental use of Larson's modified ratio (LMR) which incorporates hydraulic detention time will be necessary. Several methods to prove the inhibitive effect of improving the LI value on water quality have been also suggested.

Characteristics and Improvement of Tap Water Corrosivity in Korea (국내 수돗물의 부식성 특성 및 개선방안)

  • Kim, Jin-Keun;Kim, Yeong-Kwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.5
    • /
    • pp.731-739
    • /
    • 2011
  • To investigate corrosivity characteristics of tap water in Korea, Langelier index (LI) of 30 multi-regional water treatment plants (WTPs) were evaluated. Weekly LI values of 30 WTPs were all negative, which means tap water in Korea might be very corrosive. Maximum LI decrease through water treatment processes was 0.95 under no additional corrosion control process. Based on the correlation results between LI and tap water qualities, pH and calcium concentration were confirmed as major parameters for LI control. Addition of calcium hydroxide with $CO_{2}$ or calcium hydroxide or sodium hydroxide can be chosen based on water quality. Continuous monitoring of LI and related parameters is recommended in water distribution system.

Evaluation of Corrosion Index by Water Quality Parameters in Korea (국내 수질에 적합한 부식성지수 선정 연구)

  • Ahn, Kyunghee;Yu, Soonju;Park, Sujeong;Kwon, Ohsang
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.4
    • /
    • pp.615-623
    • /
    • 2012
  • In this study, we evaluate the corrosion indexes (CI) such as Langelier Index (LI), Larson ratio (LR), Ryznar saturation index (RSI), Aggressiveness index (AI) of water quality for raw water, treated water and water in distribution reservoir at major eight drinking water treatment plants (DWTPs) in Korea. By analyzing secondary contamination of tap water, the variation of secondary contaminants was investigated with regard to pipe materials, aging and corrosion index (CI). In addition, we suggested an appropriate CI applicable water quality and the management plan for CI monitoriing. All CI showed corrosive water quality, and they did not change significantly in the distribution network. However, Copper (Cu), iron (Fe) and zinc (Zn) concentrations as secondary contaminants increased through the distribution network. Among CI, LI was most sensitive to changes in raw water quality and drinking water treatment. Also, it has high correlations with other indexes such as RSI, AI. Therefore, LI is considered as an appropriate CI to the domestic water quality. Based on these result, we propose LI as a drinking water quality standard to control the pipe corrosion from DWTPs.

A study on the corrosion control of tap water by lime and carbon dioxide (소석회와 이산화탄소를 이용한 수돗물 부식성 제어에 관한 연구)

  • Cheong, Won-Suk;Kim, Jin-Keun;Park, Duk-Joon;Kim, Sun-Wook;Jeong, Sang-Gi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.2
    • /
    • pp.193-199
    • /
    • 2011
  • A method to improve internal corrosion control efficiency by adding lime and carbon dioxide, which, in turn increases the Langelier Index (LI) for filtered water at a conventional drinking water treatment plant (WTP) was investigated. The SJ WTP (Q=100,000 $m^{3}$/d) has been operating an internal corrosion control system since 2006. The system has achieved stable operation through technical development and trial and error over a period of several years. As a result of the operation, the LI of treated water has increased up to 29% by adjusting pH of filtered water to 7.8 with the addition of lime and carbon dioxide. Coupon tests in the distribution system indicated that the corrosion rate has been delayed by 24% when the internal corrosion method was implemented. The increase of LI by lime and carbon dioxide has been proven to be a practical method for controlling corrosion.

Effect of corrosive water quality control and corrosion index monitoring in pilot scale pipeline simulator (파일럿 규모 모의관로에서 부식성 수질제어 효과와 부식지수 모니터링)

  • Kim, Do-Hwan;Kim, Yung-Jin;Son, Hee-Jong;Ryou, Dong-Choon;Ahn, Jun-Young;Kim, Cheolyong;Hwang, In-Seong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.2
    • /
    • pp.183-192
    • /
    • 2018
  • Applicability of corrosion inhibitor was evaluated using pilot scale water distribution pipe simulator. Calcium hydroxide was used as corrosion inhibitor and the corrosion indices of the water were investigated. Corrosion indices, Langelier saturation index (LI) increased by 0.8 and calcium carbonate precipitation potential (CCPP) increased by 9.8 mg/L. This indicated that corrosivity of water decreased by corrosion inhibitor and the effects lasted for 18 days. Optimum calcium hydroxide dose was found to be 3~5 mg/L for corrosion inhibition. We suggest that monitoring of CCPP as well as LI need to be conducted to control corrosivity of water.

Control of the CaCO3 Saturation Index Parameters for Protecting the Corrosion of Waterworks Pipe (상수도관 부식방지를 위한 탄산칼슘 포화지수(LI) 인자 제어에 관한 연구)

  • Park, Young-Bok;Kong, Sung-Ho
    • Applied Chemistry for Engineering
    • /
    • v.16 no.3
    • /
    • pp.372-378
    • /
    • 2005
  • Calcium Carbonate Saturation Index (LI: Langelier Index), an indicator of $CaCO_3(s)$ saturation, indicates corrosiveness of drinking water and it has been used to monitor drinking water conditions in USA, E.U, and Japan. The objective of this research was to measure LI parameters including water temperature, pH, total alkalinity, calcium ion concentration, and electric conductivity, and to evaluate possibility of using LI in domestic system. Results showed that water temperature varied from 2.0 to $26^{\circ}C$ during 15 months, indicating an average annual temperature of $23.9^{\circ}C$. Total alkalinity was from 20 to 45 mg/L. The concentration difference between total alkalinity and $HCO_3{^-}$ value was hardly observed; the concentration of total alkalinity can be replaced by that of $HCO_3{^-}$. Tap water had a medium corrosiveness since LI values were from 2.0 to 0.5. To reduce the corrosiveness and to increase LI values of drinking water, the results of this study showed that chemicals such as $Ca(OH)_2$, $CaCO_3$, NaOH, or $NaHCO_3$ should be added to water treatment plants.

The Monitoring of Corrosive Water Quality in Water Distribution System by Corrosion Characteristics of Raw and Tap water (원·정수의 부식특성에 따른 상수관망에서의 부식성 수질 모니터링)

  • Bae, Seog-Moon;Kim, Do-Hwan;Son, Hee-Jong;Choi, Dong-Hoon;Kim, Ik-Sung;Kim, Kyung-A
    • Journal of Environmental Science International
    • /
    • v.24 no.7
    • /
    • pp.907-915
    • /
    • 2015
  • The tap water is generally known to be corrosive in the pH range at 6.5 ~ 7.5. And the degree of corrosion varies depending on the types of raw water such as river surface water or lake water of the dam. Although several corrosion index represents the corrosivity of tap water, the typical corrosion indexes such as Langelier saturation index (LI) and calcium carbonate precipitation potential (CCPP) were calculated to monitoring the corrosive water quality about raw and tap water in water distribution system. To control the corrosive water quality, the correlation between corrosion index and water quality factors were examined. In this study, corrosion index (LI, CCPP) and the pH was found to be most highly correlated.

The Corrosion Effect of the Water Pipelines in Buildings according to Drinking Water Quality (수돗물 수질에 따른 옥내급수관 부식에 미치는 영향분석)

  • Yu, Soon-Ju;Park, Su-Jeong;Ahn, Kyung-Hee;Kim, Hyun-Gu;Kim, Chang-Soo;Jung, Il-Rock;Park, Young-Bok
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.6
    • /
    • pp.701-708
    • /
    • 2008
  • As a countermeasure for reduction of corrosion in the delivery and distribution pipes used for tap water, materials for the pipelines in-houses and the effect of water quality on corrosivity of water pipelines were investigated in the distribution system of Han river. As the corrosion index at 6 water purification facilities of Han river, average Langelier Saturation Index (LI) of raw and finished water were -1.0 and -1.4 respectively and average Larson Index (LR) were 9.5 and 9.9, respectively. And also corrosion potential showed corrosivity in finished water (-431~-462 mV) as well as raw water (-426~-447 mV). This results indicate that tap water quality of han river have corrosivity. To understand the corrosivity effect in pipe material used for premise distribution system, water quality of stagnant tap water and tap water were analyzed and the differences between them were calculated. The difference concentration of iron, copper and zinc were $12.9{\mu}g/L$, $31.0{\mu}g/L$ and $45.0{\mu}g/L$ respectively in galvanized steel pipe for use more than 15 years and showed highest concentration. As a result, the control to corrosivity in the water pipelines, corrosivity control treatment in the water purification system can be applied. In advance it is necessary to monitor corrosivity of water quality using corrosive index because corrosivity may differ from the seasonal and regional characteristics and water chemicals dosage. For the future the guideline for corrosion index have to be established.

Improvement of tap water corrosivity by lime and carbon dioxide (액상소석회와 이산화탄소를 이용한 수돗물 부식성 개선)

  • Kim, Jinkeun;Lee, Junghoon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.6
    • /
    • pp.725-733
    • /
    • 2014
  • 16 water treatment plants(WTPs) in Jeju province were investigated to evaluate the corrosivity of tap water. In addition, the impacts of lime and carbon dioxide on LI changes at ES WTP were analyzed. The average of LI in Jeju tap was -1.78 which was similar to that of in-land multi-regional WTPs. The recommended process to improve LI of ES WTP which has high corrosivity(i.e., LI = -2.61) was to combine lime and carbon dioxide with the dosages of 20 mg/L and 5 mg/L respectively to meet LI of -1.0 ~ 0. pH was confirmed to be a major water quality parameter that determined LI based on the correlation results among LI and water quality parameters. Precaution on turbidity increase by lime addition should given to minimize particle breakthrough in the distribution system. Turbidity increase can be controlled by the addition of lime prior to filters.