• Title/Summary/Keyword: Landfill gas

Search Result 236, Processing Time 0.026 seconds

A Case Study of Bottom Liner Construction Using Composite Liner Technology in a Solid Waste Landfill (복합차수층 조성기술을 이용한 폐기물매립지 바닥차수층 시공사례)

  • Lee, Kyu-Jung;Lee, Nam-Hoon;Park, Soo-Young;Jeon, Won-Pyo;Lee, Chae-Young
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.15 no.3
    • /
    • pp.90-96
    • /
    • 2007
  • Modern waste management units, so-called "landfills" protect human health and environment from hazardous leachate and gas. Accordingly, it must be constructed with a bottom liner system that includes a gas collection layer. Leachate is the contaminated liquid that drains from the waste material pollutes ground water. For this reason. bottom liner system must have durability and low hydraulic conductivity (in case of compacted clay liner, no more than $1{\times}10^{-7}cm/sec$ ). P county in Kangwon province constructed a solid waste landfill with bottom liner system. In this study. it is mainly introduced that the test results on construction and quality control of bottom liner system by "Multiple composite liner construction technology", which is selected for bottom liner system in P solid waste landfill.

  • PDF

Estimation of Economics thorough Prediction of Methane Generation using IPCC Guideline from C Sanitary Landfill (IPCC가이드라인을 이용한 중소도시 C위생매립장의 메탄가스 발생량 예측을 통한 경제성 평가)

  • Lee, Sang-Woo;Park, Seo-Yun;Chang, In-Soo;Kang, Byung-Wook;Park, Sang-Chan;Yeon, Ik-Jun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.189.1-189.1
    • /
    • 2011
  • Global warming effect was intensified due to rapid growth of fossil fuel consumption caused by urbanization and industrialization. Various efforts was being done to solve the problems leading to anomaly climate such as flood, downpour, heavy snow. As a results of international efforts for management of global warming, Kyoto Protocol, which was passed in Kyoto, Japan in 1997, designated $CO_2$, $CH_4$, $N_2O$, HFCs, PFCs, $SF_6$ as a global warming gases. And IPCC(Intergovernmental Panel on Climate Change) suggested IPCC guideline for systematic establishment of national greenhouse gas inventory. Among five categories in IPCC guideline, the representative emission source of waste category is SWDS(solid waste disposal site). The concentrative research should progress for effective management of greenhouse gas related with waste. In this study, Tier1 and Tier2 methods which was suggested by 2006 IPCC(Intergovernmental Panel on Climate Change) guideline, was used to predict methane generation from C sanitary landfill located in Chungju area. To predict methane generation from C sanitary landfill, all factors were defaults values that were provided by 2006 IPCC guideline and Korea emission factors for Tier1 and Tier2 method. And economics of generated methane was estimated. From the predicted result using IPCC guideline, the methane generation was persistingly increased over a 9-year period(2000 ~ 2008). Aggregated amount of methane generation was about 3,017ton and 3,170ton predicted by Tier1 and Tier2, respectively. From the results of estimated economic value gained by generated methane from the C sanitary landfill for ten years from now(2010 ~ 2020), the profit was about 2.39 ~ 2.76 hundred million won.

  • PDF

Assessment of Leachate from Solid Waste Landfills in Daechong Lake Upper Drainage Basin (대청호 상류유역 매립지의 침출수 분석 및 평가)

  • Hong, Sang-Pyo
    • Journal of Environmental Impact Assessment
    • /
    • v.12 no.3
    • /
    • pp.161-170
    • /
    • 2003
  • To investigate the characteristics of 17 solid waste landfills in the upper drainage basin of Lake Daechong, the landfill sites were surveyed, the leachate of these landfills were analyzed, and the analysis results were assessed from standpoint of water contamination. Sanitary landfills which are now being operated are relatively well equipped with facilities such as leachate collection, daily soil cover and landfill gas treatment devices. But a few of open-dumping landfills were leaking leachate apparently and were supervised improperly and neglectfully by local governments. Some of sanitary landfills exceeded the COD permission criteria of leachate effluent, and some of open-dumping landfills exceeded SS, T-P, Pb, As, Fe, Mn permission criteria of leachate effluent. To improve the water quality of Lake Daechong which is utilized for supplying drinking water, agricultural water, and industrial water to the great part of Chungchong area, the adequate and prompt measures for preventing Daechong Lake water contamination from landfills leachate is necessary.

Effects of Spark Plug Changes on Performance of an SI Engine Fueled by Gaseous Fuel (스파크플러그 변화에 따른 가스 엔진 성능 변화)

  • Lee, Sunyoup
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.6
    • /
    • pp.27-32
    • /
    • 2013
  • Renewable gas fuels such as biogas and landfill gas are obtained from the biodegradable organic wastes so that they inherently have carbon-neutral nature which can respond global warming. Therefore, attentions are paid to use this renewable gases as a main fuel for internal combustion engines. However, the composition of the fuel varies by its origin or conversion process, it is necessary to make stable combustion and accomplish high efficiency when used in power generating spark ignition (SI) engines. In this study, efforts have been made to investigate the effect of the composition of renewable gas fuel on the engine performance and exhaust emissions. In addition, a new spark plug with a long electrode was tested and compared with a base spark plug as a way to improve engine efficiency and reduce harmful emissions.

Combustion Characteristics of Landfill Gas in Constant Volume Combustion Chamber for Large Displacement Volume Engine (II) - Combustion Analysis - (대형기관 모사 정적연소실에서 매립지 가스의 연소특성에 대한 연구 (II) - 연소 분석 -)

  • Kwon, Soon Tae;Park, Chanjun;Ohm, Inyong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.8
    • /
    • pp.743-752
    • /
    • 2013
  • This is the second paper on the combustion characteristics of landfill gas in a constant volume combustion chamber for a large displacement volume commercial engine, and it discusses the combustion process on the basis of pressure measurements. The results show that the bimodal peak pressure phenomenon, which is caused by the interaction of the heat release and the heat transfer, is more apparent as the mixtures are more favorable to combustion, and the magnitudes of the pressures depend on the unburned fraction. In addition, there exist four main inflection points during heat release owing to variations in the heat transfer area related to flame propagation from the ignition point. Furthermore, the number of inflection points increases as the mixture quality worsens because of the extended burn duration. Consequently, the sophisticated interactions between the heat transfer area changing pattern due to flame propagation and transfer duration might cause very peculiar heat release patterns.

Combustion Characteristics of Landfill Gas in Constant Volume Combustion Chamber for Large Displacement Volume Engine (III) - Torch Ignition (1) - (대형기관 모사 정적연소실에서 매립지 가스의 연소특성에 대한 연구 (III) - 토치 점화 (1) -)

  • Kim, Inok;Ohm, Inyong;Kwon, Soon Tae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.2
    • /
    • pp.125-134
    • /
    • 2015
  • This is the third paper on the combustion characteristics of the landfill gas in a constant volume combustion chamber for a large displacement volume commercial engine. It is the first in this series to discuss the effects of the torch device on combustion. The results show that an optimum orifice ratio exists regardless of the torch volume, and a few adverse effects on the combustion are observed for an excessively small orifice ratio. In addition, the torch ignition decreases the initial burn duration, and the decrease in the heat transfer caused by this decreased duration contributes to an increase in the peak combustion pressure. Finally, the torch mostly plays a positive role in shortening the main burn duration when the combustion condition is worsened by a lower methane fraction. Yet, the torch decreases the initial burn duration rather than the main burn as the methane fraction increases.

Water table: The dominant control on CH4 and CO2 emission from a closed landfill site

  • Nwachukwu, Arthur N.;Nwachukwu, Nkechinyere V.
    • Advances in environmental research
    • /
    • v.9 no.2
    • /
    • pp.123-133
    • /
    • 2020
  • A time series dataset was conducted to ascertain the effect of water table on the variability in and emission of CH4 and CO2 concentrations at a closed landfill site. An in-situ data of methane/carbon dioxide concentrations and environmental parameters were collected by means of an in-borehole gas monitor, the Gasclam (Ion Science, UK). Linear regression analysis was used to determine the strength of the correlation between ground-gas concentration and water table. The result shows CH4 and CO2 concentrations to be variable with strong negative correlations of approximately 0.5 each with water table over the entire monitoring period. The R2 was slightly improved by considering their concentration over single periods of increasing and decreasing water table, single periods of increasing water table, and single periods of decreasing water table; their correlations increased significantly at 95% confidence level. The result revealed that fluctuations in groundwater level is the key driving force on the emission of and variability in groundgas concentration and neither barometric pressure nor temperature. This finding further validates the earlier finding that atmospheric pressure - the acclaimed major control on the variability/migration of CH4 and CO2 concentrations on contaminated sites, is not always so.

Composition of Degradation and Stabilization in Landfilled Waste (매립폐기물의 분해 성상 및 안정화)

  • Kim, Eun-Ho;Son, Hee-Jung;Sung, Nak-Chang;Heo, Jong-Soo;Kim, Hyeong-Seok
    • Korean Journal of Environmental Agriculture
    • /
    • v.16 no.1
    • /
    • pp.31-36
    • /
    • 1997
  • This study was carried out to analyze the composition of landfill generation gas using vertical pipe wells installed at landfill. The characteristics of composed waste were examined by the open-cut test at H. landfill in Pusan. The waste compositions of landfill layer by Open-cut test indicated that organic matter was average $4.6{\sim}8.78%$ in each landfill. $CH_4$ compositions of gas in each landfill were $49.71{\sim}50.45%$(A-point), $50.39{\sim}53.74%$(B-point), and $58.76{\sim}61.62%(C-point), respectively. The chemical formula of organic matter left in the underground was $C_{36.3}H_{76}O_{30}N_{0.3}S_{0.1}$ Underground temperatures were changed to $18.8{\sim}25.8^{\circ}C$ when the ambient temperature was about $13.4^{\circ}C$. Temperatures with passed times in A, B and C-lysimeter were about $21.1{\sim}22.5^{\circ}C,\;30{\sim}32.5^{\circ}C$ and $35{\sim}38.5^{\circ}C$, respectively. After about 65 day, decomposition rates of organic matter in A, B and C-lysimeter were 9.9%, 14.9% and 22.3%, respectively.

  • PDF

Estimation of greenhouse gas emissions from the landfill sector with the application of the 2006 IPCC guidelines and the change factors analysis (2006 IPCC 가이드라인 적용에 따른 폐기물 매립 부문의 온실가스 배출량 산정 및 변화 요인 분석)

  • Kim, Ran-Hui;Park, Jin-Kyu;Song, Sang-Hoon;Park, Ok-Yun;Lee, Nam-Hoon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.28 no.1
    • /
    • pp.37-51
    • /
    • 2020
  • Following the Paris Agreement adopted at the end of 2015, global stock-taking has been planned to be carried out on a 5-year basis from 2023, and it is mandatory to report on national GHG inventory and progress toward achieving greenhouse gas reduction targets. To prepare for this, it is important to improve the reliability of estimation of the greenhouse gas emission, identify the characteristics of each greenhouse gas emission source, and manage the amount of emissions. As such, this study compared and analyzed the amount of emissions from the landfill sector using the 2000 GPG, the 2006 IPCC Guidelines, and the 2019 Refinement estimation method. As a result, in comparison to 2016, there were 2,287 Gg CO2_eq. in scenario 1, 1,870 Gg CO2_eq. in scenario 2-1, 10,886 Gg CO2_eq. in scenario 2-2, 10,629 Gg CO2_eq. in scenario 2-3, and 12,468 Gg CO2_eq. in scenario 3. Thus, when the 2006 IPCC Guidelines were applied with respect to 2000 GPG, it was revealed that greenhouse gas emissions have increased. Such difference in the emission changes was due to the changes in the calculation method and the emission factor values applied. Therefore, it is urgent to develop national-specific values of the emission factor based on characteristics of greenhouse gas emission in Korea.

Evaluation of Methane Generation Rate Constant(k) by Estimating Greenhouse Gas Emission in Small Scale Landfill (소규모 매립지에 대한 메탄발생속도상수(k) 산출 및 온실가스 발생량 평가)

  • Lee, Wonjae;Kang, Byungwook;Cho, Byungyeol;Lee, Sangwoo;Yeon, Ikjun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.5
    • /
    • pp.5-11
    • /
    • 2014
  • In this study, greenhouse gas emission for small scale landfill (H and Y landfill) was investigated to deduce special the methane generation rate constant(k). To achieve the purpose, the data of physical composition was collected and amount of LFG emission was calculated by using FOD method suggested in 2006 IPCC GL. Also, amount of LFG emission was directly measured in the active landfill sites. By comparing the results, the methane generation rate constant(k), which was used as input variable in FOD method suggested in 2006 IPCC GL, was deduced. From the results on the physical composition, it was shown that the ranges of DOC per year in H (1997~2011) and Y (1994~2011) landfill sites were 13.16 %~23.79 % ($16.52{\pm}3.84%$) and 7.24 %~34.67 % ($14.56{\pm}7.30%$), respectively. The DOC results showed the differences with the suggested values (= 18 %) in 2006 IPCC GL. The average values of methane generation rate constant(k) from each landfill site were $0.0413yr^{-1}$ and $0.0117yr^{-1}$. The results of methane generation rate constant(k) was shown big difference with 2006 IPCC GL defualt value (k = 0.09). It was confirmed that calculation results of greenhouse gas emission using default value in 2006 IPCC GL show excessive output.