• Title/Summary/Keyword: Land use facility

Search Result 191, Processing Time 0.032 seconds

Ecological Characteristics and Management Plan of Geumdangsil Pine Forest of Yecheon (예천 금당실 송림의 생태적 특성 및 관리방안)

  • Lee, Soo-Dong;Lee, Chan;Kim, Donwook;Kim, Jisuk
    • Korean Journal of Environment and Ecology
    • /
    • v.27 no.6
    • /
    • pp.718-732
    • /
    • 2013
  • The purpose of this study was to provide data for the basic research to found the effective conservation and management plan for the Geumdangsil Pine Forest of Yecheon designated as Natural Monument No. 469. Furthermore, this paper suggest efficient sustainable forest preservation and using. In order to achieve the sustainable forest preservation, this study was to analyse topography, land use, tree growth, soil environment, forest usage and forest management, etc. According to analysis the results, the site area is located in the flatlands where is from 130 to 140 m above sea level. The around forest was transformed into agricultural land. The 565 individuals of Pinus densiflora grows in the forest, whereas, 25 trees was cut down or died. There are signs of 25 stumps. The most of 565 trees' diameter at breast height(DBH) was centerized between 30 cm and 50 cm, moreover, the average life expectancy of trees were 85.4 years. The oldest age of tree was estimated to be 200 years. The Sample trees of rate of branch growth is from 4.3 cm to 5.1 cm per year. The middle branch which is more vigorous growth grow 24.2 cm for 3 years. Moreover, the result of soil physico-chemical properties analysis of 7 plots, 4 categories which is soil organic matter, total nitrogen, available phosphoric acid, specific electrical conductance was generally good, however, the 2 categories which is soil pH, exchangeable cation needed improvement. Currently, the site was not pressured by facilities and usage, however, there might be threaten by agriculture such as encroaching on forest. Therefore, there should establish comprehensive ecosystem management such as facility management, visitors management and operation management In this paper considered 4 fields that is ecosystem management, facility management, visitors management and operation management for sustainable management.

Estimation of Optimal Size of the Treatment Facility for Nonpoint Source Pollution due to Watershed Development (비점오염원의 정량화방안에 따른 적정 설계용량결정)

  • Kim, Jin-Kwan
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.6
    • /
    • pp.149-153
    • /
    • 2008
  • The pollutant capacity occurred before and after the development of a watershed should be quantitatively estimated and controlled for the minimization of water contamination. The Ministry of Environment suggested a guideline for the legal management of nonpoint source from 2006. However, the rational method for the determination of treatment capacity from nonpoint source proposed in the guideline has the problem in the field application because it does not reflect the project based cases and overestimates the pollutant load to be reduced. So, we perform the standard rainfall analysis by analytical probabilistic method for the estimation of an additional pollutant load occurred by a project and suggest a methodology for the estimation of contaminant capacity instead of a simple rational method. The suggested methodology in this study could determine the reasonable capacity and efficiency of a treatment facility through the estimation of pollutant load from nonpoint source and from this we can manage the watershed appropriately. We applied a suggested methodology to the projects of housing land development and a dam construction in the watersheds. When we determine the treatment capacity by a rational method without consideration of the types of projects we should treat the 90% of pollutant capacity occurred by the development and to do so, about 30% of the total cost for the development should be invested for the treatment facility. This requires too big cost and is not realistic. If we use the suggested method the target pollutant capacity to be reduced will be 10 to 30% of the capacity occurred by the development and about 5 to 10% of the total cost can be used. The control of nonpoint source must be performed for the water resources management. However it is not possible to treat the 90% of pollutant load occurred by the development. The proper pollutant capacity from nonpoint source should be estimated and controlled based on various project types and in reality, this is very important for the watershed management. Therefore the results of this study might be more reasonable than the rational method proposed in the Ministry of Environment.

A Study for Planning Optimal Location of Solar Photovoltaic Facilities using GIS (GIS를 이용한 태양광시설 설치를 위한 적정지역 선정에 관한 연구)

  • Yun, Sung-Wook;Paek, Yee;Jang, Jae-Kyung;Choi, Duk-Kyu;Kang, Donghyeon;Son, Jinkwan;Park, Min-Jung;Kang, Suk-Won;Gwon, Jin-Kyung
    • Journal of Bio-Environment Control
    • /
    • v.28 no.3
    • /
    • pp.243-254
    • /
    • 2019
  • With the recent accelerated policy-making and interests in new renewable energy, plans to develop and supply the new renewable energy have been devised across multiple regions in Korea. Solar energy, in particular, is being applied to small-scale power supply in provincial areas, as solar cells are used to convert solar energy into electric energy to produce electric power. Nonetheless, in the case of solar power plants, the need for a large stretch of land and considerable sum of financial support implies that the planning step should take into consideration the most suitable meteorological and geographical factors. In this study, the proxy variables of meteorological and geographical factors associated with solar energy were considered in analyzing the vulnerable areas regarding the photovoltaic power generation facility across the nation. GIS was used in the spatial analysis to develop a map for assessing the optimal location for photovoltaic power generation facility. The final vulnerability map developed in this study did not reveal any areas that exhibit vulnerability level 5 (very high) or 1 (very low). Jeollanam-do showed the largest value of vulnerability level 4 (high), while a large value of vulnerability level 3 (moderate) was shown by several administrative districts including Gwangju metropolitan city, Jeollabuk-do, Chungcheongbuk-do, and Gangwon-do. A value of vulnerability level 2 (low) was shown by the metropolitan cities including Daegu, Ulsan, and Incheon. When the 30 currently operating solar power plants were compared and reviewed, most were found to be in an area of vulnerability level 2 or 3, indicating that the locations were relatively suitable for solar energy. However, the limited data quantity for solar power plants, which is the limitation of this study, prevents the accuracy of the findings to be clearly established. Nevertheless, the significance of this study lies in that an attempt has been made to assess the vulnerability map for photovoltaic power generation facility targeting various regions across the nation, through the use of the GIS-based spatial analysis technique that takes into account the diverse meteorological and geographical factors. Furthermore, by presenting the data obtained for all regions across the nation, the findings of this study are likely to prove useful as the basic data in fields related to the photovoltaic power generation.

The Effective Approach for Non-Point Source Management (효과적인 비점오염원관리를 위한 접근 방향)

  • Park, Jae Hong;Ryu, Jichul;Shin, Dong Seok;Lee, Jae Kwan
    • Journal of Wetlands Research
    • /
    • v.21 no.2
    • /
    • pp.140-146
    • /
    • 2019
  • In order to manage non-point sources, the paradigm of the system should be changed so that the management of non-point sources will be systematized from the beginning of the use and development of the land. It is necessary to change the method of national subsidy support and poeration plan for the non-point source management area. In order to increase the effectiveness of the non-point source reduction project, it is necessary to provide a minimum support ratio and to provide additional support according to the performance of the local government. A new system should be established to evaluate the performance of non-point source reduction projects and to monitor the operational effectiveness. It is necessary to establish the related rules that can lead the local government to take responsible administration so that the local governments faithfully carry out the non-point source reduction project and achieve the planned achievement and become the sustainable maintenance. Alternative solutions are needed, such as problems with the use of $100{\mu}m$ filter in automatic sampling and analysis, timely acquisition of water sampling and analysis during rainfall, and effective management of non-point sources network operation management. As an alternative, it is necessary to consider improving the performance of sampling and analysis equipment, and operate the base station. In addition, countermeasures are needed if the amount of pollutant reduction according to the non-point source reduction facility promoted by the national subsidy is required to be used as the development load of the TMDLs. As an alternative, it is possible to consider supporting incentive type of part of the maintenance cost of the non-point source reduction facility depending on the amount of pollutants reduction.

Geotechnical Evaluation on the Application of Reactive Vertical Drainage Method (반응성연직배수공법의 적용에 대한 지반공학적 평가)

  • Na, Hyoung-Yun;Chae, Deokho;Oh, Myoung-Hak;Cho, Wanjei
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.7
    • /
    • pp.13-17
    • /
    • 2012
  • Recently, our ocean development paradigm is changing so that the development focus has been moved from the port facility developments to creating useful marine space. This paradigm accords well with the current green technology and helps the growth of service industries and the development from this paradigm can become a national land mark. Accordingly, the concept of creating marine waste landfill by the development of resource recycling technology has been introduced for eco-friendly space as an artificial island in future. Therefore, this study introduces the reactive vertical drainage method that is to pursue the purification of pollutants as well as stabilization of newly deposited soils in marine environments. To install the reactive vertical drainage piles for more effective feasibility and constructability, placements of drainage mid-layer are considered in the geotechnical viewpoint. Consolidation characteristics were evaluated by standard consolidation tests after several types of model test. As s result, the application of mid-layer drainage is strongly recommended in the reactive vertical drainage to quickly stabilize newly deposited soils. And vacuum consolidation method has better consolidation characteristic than vertical loading method in terms of the settlements predicted by additional stress for further use as an artificial island.

Implementation of Rule Management System for Validating Spatial Object Integrity (공간 객체 무결성 검증을 위한 규칙 관리 시스템의 구현)

  • Go, Goeng-Uk;Yu, Sang-Bong;Kim, Gi-Chang;Cha, Sang-Gyun
    • Journal of KIISE:Software and Applications
    • /
    • v.26 no.12
    • /
    • pp.1393-1403
    • /
    • 1999
  • 공간 데이타베이스 시스템을 통하여 공유되는 공간 데이타는 무결성이 적절하게 유지되지 않는 한 전체 응용 시스템의 행위를 예측할 수 없게 되므로 데이타의 무결성 확인 및 유지는 필수적이다. 특히 공공 GIS에 저장된 공간 데이타는 토지 이용도 평가, 도시 계획, 자원 관리, 시설물 관리, 안전 관리, 국방 등 국가 전체 및 지역의 중요한 정책 결정을 위한 다양한 응용 시스템들에 의해 이용되므로 적절한 공간 객체의 무결성 확인이 더욱 더 필요하다. 본 논문에서는 능동(active) DBMS의 능동 규칙(active rule) 기법을 이용하여 공간 객체의 무결성 확인을 지원하기 위한 규칙 관리 시스템을 제시한다. 능동 규칙을 이용한 공간 객체의 무결성 확인은 응용 프로그래머를 무결성 확인에 대한 부담으로부터 자유롭게 할 수 있다. 본 시스템은 특정 DBMS에 종속되지 않는 독립적인 외부 시스템으로 존재하며, 능동 규칙 관리기, 규칙 베이스, 그리고 활성규칙 생성기의 3 부분으로 구성된다. 사용자가 공간 데이타베이스 응용 프로그램을 통해 공간 객체를 조작하고자 할 때, 본 시스템은 데이타베이스 트랜잭션을 단위로 조작되는 모든 공간 객체의 무결성 확인을 위해 응용 프로그램에 삽입될 무결성 제약조건 규칙들을 효율적으로 관리하는 역할을 한다.Abstract It is necessary that the integrity of spatial data shared through the spatial database system is validated and appropriately maintained, otherwise the activity of whole application system is unpredictable. Specially, the integrity of spatial data stored in public GIS has to be validated, because those data are used by various applications which make a decision on an important policy of the region and/or whole nation such as evaluation of land use, city planning, resource management, facility management, risk management/safety supervision, national defense. In this paper, we propose rule management system to support validating the integrity of spatial object, using the technique of active rule technique from active DBMS. Validating data integrity using active rules allows database application programmer to be free from a burden on validation of the data integrity. This system is an independent, external system that is not subject to specific DBMS and consists of three parts, which are the active rule manager, the rule base, and the triggered rule generator. When an user tries to manipulate spatial objects through a spatial database application program, this system serves to efficiently manage integrity rules to be inserted into the application program to validate the integrity constraints of all the spatial objects manipulated by database transactions.

Visualization and contamination analysis for groundwater quality of CDEWSF in Gwangju area using statistical method (통계적 기법을 이용한 광주지역 민방위비상급수용 지하수 수질 오염도 분석 및 시각화 연구)

  • Jang, Seoeun;Lee, Daehaeng;Kim, Jongmin;Kim, Haram;Jeong, Sukkyung;Bae, Seokjin;Cho, Younggwan
    • Analytical Science and Technology
    • /
    • v.31 no.3
    • /
    • pp.122-133
    • /
    • 2018
  • In this study, groundwater quality data measured for 11 years from 2006 to 2016 were analyzed statistically for 101 civil defense emergency water supply facilities (CDEWSF) in the Gwangju area. The contamination level was quantified into four grades by using excess drinking water quality standards, average concentration analysis, and tendency analysis results for each facility. On the basis of this approach, the groundwater contamination degree of each item was evaluated according to land use status, installation year, depth, and geological distribution. The contamination grade ratios, which were obtained by analyzing three contamination indicators (water quality exceeded frequency, average concentration analysis, and trend analysis) for 15 items on statistically significant of civil defense emergency water was relatively high, in the order of Turbidity (51.5 %) > Color (32.7 %) > Nitrate nitrogen (28.7 %) > Hardness (25.7 %). As a result of the contamination grade analysis, except for the items of Turbidity, Color, and Nitrate nitrogen, the contamination levels were distributed in various degrees from "clean (0)" to "seriously contaminated (3)." Regarding the contamination grade of 12 items, 25 % of the total were classified as "possibly contaminated (1)," and 75 % were rated "clean (0)." The four items (Turbidity, Color, Nitrate nitrogen, and Hardness) for which contamination indication rate were evaluated as "high" by the were visualized on a contamination map.

Analysis on the Factors Affecting the Satisfaction of Underground Shopping Center -From the cases in Busan Metropolitan Region- (지하도 상가 만족도에 영향을 미치는 요인 분석 -부산시 사례를 중심으로-)

  • Han, Seung-Uk;Jang, Jin-Hyeok;Choi, Yeol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.297-307
    • /
    • 2017
  • There are many underground spaces available in an urban environment and they represent an important factor for efficient land use. Especially, underground shopping centers perform both physical and commercial functions at the same time and are frequently used as a means of achieving the revitalization of the city center. However, the underground shopping centers that were developed in the past sometimes led to recession due to their deterioration. This study was carried out for the purpose of proposing alternative methods for the (revitalization) of underground shopping centers. A survey was conducted on seven underground shopping centers in the Busan metropolitan area to understand the factors that determine their user satisfaction and future improvement. The survey data was analyzed using an ordered logit model. As a result of the analysis, service satisfaction, underground environment satisfaction and public facility satisfaction were selected as significant variables. It was concluded that it is necessary to take these factors into consideration, appropriately, when developing a new or renewing an existing underground shopping mall.

A study on the estimation of river water intake using the operating time of the pumping station (양수장의 가동시간을 이용한 하천수 취수량 산정방안 연구)

  • Baek, Jongseok;Kim, Chiyoung;Cha, Jun-Ho;Song, Jaehyun
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.2
    • /
    • pp.89-96
    • /
    • 2020
  • Water management agencies under the Ministry of Environment produce and accumulate qualified basic data for major rivers. However, the integrated management of the river water has been weak since the artificial water circulation process, such as the intaking and drainage of agricultural water, has not been examined in the basin, which includes many agricultural land. In this study, a study was conducted on how the power usage method (operating time method) based on the running time can be applied and improved among indirect flow rate measurement methods used to investigate flow rates collected by the riverside for agricultural water purposes, and thus the resultant data of high reliability can be obtained at low cost. The operation time method is suitable for small-scale water pumping stations where it is difficult to secure real-time power supply data. The reliability of the data was verified through the correlation analysis with the actual flow rate, and it was found that the flow rate calculated by the operation time method reflecting the level of the stream to which the inlet of the pumping station is connected can be reasonably matched with the actual flow rate. In addition, it was confirmed that the investment cost at the time of initial installation of the facility was highly efficient by generating qualified flow data at low cost through comparison with direct flow rate measurement methods. If flow data is secured by applying the operation time method to large and small water farms located along the riverside, it is expected that more quantitative and integrated stream water management will be possible.

Trend Evaluation of Self-sustaining, High-efficiency Corrosion Control Technology for Large-scale Pipelines Delivering Natural Gas by Analyzing Patent Data (특허데이터 분석을 통한 천연가스 공급용 대규모 파이프라인을 위한 자립형 고효율 부식 방지 기술의 동향평가)

  • Lee, Jong-Won;Ji, Sanghoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.730-736
    • /
    • 2019
  • The demand for natural gas, which is considered an environmentally friendly energy source, is increasing, and at the same time, the market share of large pipelines for natural gas supply is increasing continuously. On the other hand, the corrosion of such large pipelines reduces the efficiency of natural gas transportation. Therefore, this study aims to establish a strategy for securing the patent rights of related technologies through quantitative analysis of patents on energy-independent high-efficiency corrosion prevention technology for large-scale pipelines for natural gas supply. In this patent technology trend study, Korean, US, Japanese, and European patents filed, published, and registered by June 2018 were analyzed, and a technical classification system and classification criteria were prepared through expert discussion. To use fuel cells as an external power source to prevent the corrosion of natural gas large-scale pipelines, it is believed that rights can be claimed using an energy control system and methods having 1) branch structures of pipeline and facility designs (decompressor/compressor/heat exchanger) and 2) decompression/preheating and pressurization/cooling technology of high pressure natural gas.