• 제목/요약/키워드: Lancet

검색결과 17건 처리시간 0.021초

Elimination of Lancet-Related Needlestick Injuries Using a Safety-Engineered Lancet: Experience in a Hospital

  • An, Hye-sun;Ko, Suhui;Bang, Ji Hwan;Park, Sang-Won
    • Infection and chemotherapy
    • /
    • 제50권4호
    • /
    • pp.319-327
    • /
    • 2018
  • Background: Lancet-related needlestick injuries (NSIs) occur steadily in clinical practices. Safety-engineered devices (SEDs) can systematically reduce NSIs. However, the use of SEDs is not active and no study to guide the implementation of SEDs was known in South Korea. The lancet-related NSIs may be eliminated to zero incidence using a SED lancet with effective sharp injury protection and reuse prevention features. Materials and Methods: We implemented a SED lancet by replacing a conventional prick lancet in a tertiary hospital in a sequential approach. A spot test of the new SED was conducted for 1 month to check the acceptability in practice and a questionnaire survey was obtained from the healthcare workers (HCWs). A pilot implementation of the SED lancet in 2 wards was made for 1 year. Based on these preliminary interventions, a hospital-wide full implementation of the SED lancet was launched. The incidence of NSIs and cost expenditure before and after the intervention were compared. Results: There were 29 cases of conventional prick lancet-related NSIs for 3 years before the full implementation of SED lancet. The proportion of prick lancet-related NSIs among yearly all kinds of NSIs during two years before the pilot study was average 11.7% (22/188). Pre-interventional baseline incidence of all kinds of NSIs was 7.01 per 100 HCW-years. After the full implementation of SED lancet, the lancet-related NSIs became zero in the 2nd year (P = 0.001). The average direct cost of 18,393 US dollars (USD) per year from device and post-exposure medical care before the intervention rose to 20,701 USD in the 2nd year of the intervention. The incremental cost-effectiveness ratio was 210 USD per injury avoided. Conclusion: The implementation of a SED lancet could eliminate the lancet-related NSIs to zero incidence. The cost increase incurred by the use of SED lancet was tolerable.

미숙아에서 채혈을 위한 발뒤꿈치 천자시 두 종류 천자 기구의 비교 (A Comparative Study of Two Different Heel Lancet Devices for Blood Collection in Preterm Infants)

  • 임효빈;류미주;정지미;전가원;신종범
    • Neonatal Medicine
    • /
    • 제17권2호
    • /
    • pp.239-244
    • /
    • 2010
  • 목적: 효과적인 미숙아에서의 채혈방법을 모색하기 위해 미숙아에서 발뒤꿈치 천자시 새로운 자동화 천자기구(automatic lancet device)와 기존에 사용되던 고식적 수동식 천자침(conventional manual lancet device) 의 효과를 비교하여 임상에서의 유용성을 알아보고자 한다 방법: 재태 연령 37주 미만의 미숙아 총 100명을 대상으로 하였다. 연구 대상아들은 발뒤꿈치 천자시 무작위로 각 50명씩 고식적 수동식 천자 기구를 사용한 군(50명)과 자동화 천자 기구를 사용한 군(50명)으로 나누었으며, 발뒤꿈치 천자시 통증의 정도 및 천자 횟수, 검사 시간, 출혈의 여부 등을 평가하였다. 통증의 평가는 Premature Infant Pain Profile (PIPP) 점수와 최고 심장 박동수를 측정하였고, 검사시간은 발뒤꿈치 천자 시작으로부터 1개의 microtube에 채혈을 완료하는 시간까지를 측정하여 비교하였다. 천자횟수는 1개의 microtube를 혈액으로 채우기 위해 발뒤꿈치를 천자한 횟수를 측정하였다. 그리고 검사 12시간 이내에 발뒤꿈치 및 발목 주위에 출혈이나 멍 등을 관찰하였다. 결과: 통증을 나타내는 PIPP 점수의 평균은 자동화 천자기구군에서 4.91로 고식적 천자기구 군 5.84에 비해 유의하게 낮게 측정되었다(P=0.0255). 검사에 소요되는 시간은 고식적 천자군에서 평균 48.92초, 자동화 천자군에서 평균 30.69초로 자동화천자기구를 사용한 군에서 통계적으로 유의하게 짧았다(P<0.0001). 천자 횟수의 평균값은, 자동화 천자군에서 1.02로, 고식적 천자군 1.35에 비해 통계적으로 의미 있게 낮았다(P=0.0001). 검사후 출혈반점이나 멍 등은 고식적 천자기구 군에서 15례(30%), 자동화 천자기구 군에서 3례(6%)로 자동화 천자기구 사용 군에서 의미 있게 적게 나타남을 관찰할 수 있었다(P=0.0024). 결론: 자동화 절개형 천자기구(BD QuickHeel)는 검사 실패율이 낮으며, 짧은 시간에 채혈이 가능하고, 멍이나 출혈 같은 부작용이 적어 신생아, 특히 최근 생존율이 향상되어 증가되고 있는 미숙아에서 발뒤꿈치 천자에 의한 채혈에 유용한 도구가 될 수 있겠다.

채혈바늘에 의한 2차 감염 방지기능을 갖는 랜싯과 전동식 채혈기의 개발 (Development of the Electric Lancing Device and the Lancet to Prevent the Secondary Contamination by Needlestick Injury)

  • 홍성철;장석진;강신한
    • 한국산학기술학회논문지
    • /
    • 제12권12호
    • /
    • pp.5464-5468
    • /
    • 2011
  • 본 연구는 채혈바늘에 의해 발생하는 2차 감염을 방지하기 위한 안전 랜싯(Lancet)을 설계 개발하고, 연속하여 채혈하는 경우에 쉽게 그리고 편리하게 사용할 수 있도록 무선 전동방식 채혈기의 설계 제작을 목적으로 한다. 안전랜싯은 채혈침과 보호캡이 일체형으로 설계되어 채혈 순간을 제외하고는 채혈침이 항상 보호캡 속에 있도록 하여 채혈바늘에 의한 사고를 방지하도록 하였다. 전동 채혈기는 충전건전지를 전원으로 하고 솔레노이드의 작동으로 랜싯을 타격하여 채혈하도록 설계되었으며, 연발타격 또는 단발타격의 기능을 선택하도록 설계 제작되었다. 또한 타격봉에 의한 충격력과 사용된 배터리의 수명 등이 측정되었다. 이 채혈기는 한방병의원의 사혈기로도 사용되도록 제작되었다.

채혈바늘에 의한 2차 감염 방지기능을 갖는 랜싯과 전동식 채혈기의 개발 (Development of the Electric Lancing Device and the Lancet to Prevent the Secondary Contamination by Needlestick Injury)

  • 홍성철;장석진;강신한
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2010년도 추계학술발표논문집 2부
    • /
    • pp.820-823
    • /
    • 2010
  • 본 연구는 채혈바늘에 의해 발생하는 2차 감염을 방지하기 위한 안전 랜싯(Lancet)을 설계 개발하고 연속하여 채혈하는 경우에 쉽게 그리고 편리하게 사용할 수 있도록 무선 전동방식의 채혈기를 설계제작을 목적으로 한다. 안전랜싯은 채혈침과 보호캡이 일체형으로 설계되어 채혈 순간을 제외하고는 채혈침이 항상 보호캡 속에 있도록 하여 채혈바늘에 의한 사고를 방지하도록 하였다. 전동 채혈기는 충전건전지를 전원으로 하고 솔레노이드의 작동으로 랜싯을 타격하여 채혈하도록 설계되었으며, 연발 타격 또는 단발타격의 기능을 선택하도록 설계 제작되었다. 이 채혈기는 한방병의원의 사혈기로도 사용되도록 제작되었다.

  • PDF

혈당 측정을 위한 채혈기구 메인 샤프트의 사출성형 시뮬레이션 및 시 사출에 관한 연구 (A study on the blood collecting device of main shaft injection molding for measuring blood glucose by CAE analysis)

  • 백승엽
    • Design & Manufacturing
    • /
    • 제12권2호
    • /
    • pp.57-62
    • /
    • 2018
  • In diabetics, daily blood glucose testing is generally required at home, and thus, performing blood collection several times a day using a blood line is essential. Blood collection in the home and in the hospital is a source of pain and is the second most common cause of infection. In blood collecting device generally consists of four major parts: inner-case, outer case, main shaft and triger, and the most import part among those for necessary functionality is the main shaft. Filling time and injection pressure, filling balance, strain-rate analysis of change based on availability of the product. The Moldflow of FEM simulation is used for the analysis of injection molding process. In this study, aims to create a technique for injection molding and manufacturing of a main shaft of a high-performance blood-collecting apparatus capable of automatically extracting a lancet to relieve pain through depth control of the lancet.

피부관통시 통증을 최소화하는 일회용 자동 모세혈액 채취기구 (Single use Automatic Lancet to Minimize Pain During Skin Puncture)

  • 김현식;김경아;전명희;김태임;정용현;이태수;차은종
    • 대한의용생체공학회:의공학회지
    • /
    • 제23권4호
    • /
    • pp.323-327
    • /
    • 2002
  • 만성 당뇨병 질환자는 일 2회 이상 모세혈액을 채취하여 혈당검사를 행함으로써 자신의 혈당 수준을 지속적으로 관리해야 한다. 모세혈액 채취를 위하여 채혈침으로 빈번하게 피부관통을 행해야 하므로 채혈시 뒤따르는 통증은 대단히 중요한 문제이다. 본 연구에서는 기존의 수동 및 자동 채혈침들이 가지는 통증 유발요인들을 모두 최소화하는 기전을 고안하였다. 경사각을 이루는 taper형 스프링, 채혈침을 일관성있는 방향으로 이동시키는 guiding tunnel, 현존하는 기술로 제조할 수 있는 가장 가는 30G 채혈침을 적용함으로써 통증을 최소화 하였다. 침의 침투 깊이를 피하 2mm로 제한하여 통증을 최소화하는 동시에 출혈량을 감소시켰다. 또한 환자 간 감염 및 이차 감염을 방지하기 위하여 사용이 용이한 재사용 방지기전을 설치하였다. 당뇨질환자. 일반인 및 간호실습생들을 대상으로 한 임상실험 결과 통증 및 사용편의성과 안전성 모두 우수한 것으로 입증되었다. 일회 채혈로 모두 성공적인 혈당검사가 가능하였으며 단순한 구조의 소형화 ·일체화된 일회용 자동채혈침의 형태로 구현하였다 본 연구결과는 혈담검사를 위한 모세혈액 채취시 최적의 방법을 제공하였으며 실용성 또한 우수한 것으로 판단되었다.

지속가능한 식이의 개념과 측정방법 및 한국형 식이 지수 개발을 위한 방안 모색: 주제범위 문헌고찰과 기술 연구 (Sustainable diets: a scoping review and descriptive study of concept, measurement, and suggested methods for the development of Korean version)

  • 정수경
    • 대한지역사회영양학회지
    • /
    • 제29권1호
    • /
    • pp.34-50
    • /
    • 2024
  • Objectives: Transformation through a sustainable food system to provide healthy diets is essential for enhancing both human and planetary health. This study aimed to explain about sustainable diets and illustrate appropriate measurement of adherence to sustainable diets using a pre-existing index. Methods: For literature review, we used PubMed and Google Scholar databases by combining the search terms "development," "validation," "sustainable diet," "sustainable diet index," "planetary healthy diet," "EAT-Lancet diet," and "EAT-Lancet reference diet." For data presentation, we used data from National Health and Nutrition Examination Survey, 2017-2018, among adults aged 20 years and older (n = 3,920). Sustainable Diet Index-US (SDI-US), comprising four sub-indices corresponding to four dimensions of sustainable diets (nutritional quality, environmental impacts, affordability, and sociocultural practices), was calculated using data from 24-hour dietary recall interview, food expenditures, and food choices. A higher SDI-US score indicated greater adherence to sustainable diets (range: 4-20). This study also presented SDI-US scores according to the sociodemographic status. All analyses accounted for a complex survey design. Results: Of 148 papers, 16 were reviewed. Adherence to sustainable diets fell into 3 categories: EAT-Lancet reference diet-based (n = 8), Food and Agriculture Organization (FAO) definition-based (n = 4), and no specific guidelines but including the sustainability concept (n = 4). Importantly, FAO definition emphasizes on equal importance of four dimensions of diet (nutrition and health, economic, social and cultural, and environmental). The mean SDI-US score was 13 out of 20 points, and was higher in older, female, and highly educated adults than in their counterparts. Conclusions: This study highlighted that sustainable diets should be assessed using a multidimensional approach because of their complex nature. Currently, SDI can be a good option for operationalizing multidimensional sustainable diets. It is necessary to develop a Korean version of SDI through additional data collection, including environmental impact of food, food price, food budget, and use of ready-made products.

Two Litonotid Ciliates (Ciliophora: Litostomatea: Pleurostomatida) Unknown from Korea

  • Lee, Jung-Mi;Yoon, Jae-Sool;Shin, Mann-Kyoon
    • Animal Systematics, Evolution and Diversity
    • /
    • 제22권2호
    • /
    • pp.223-229
    • /
    • 2006
  • Two litonotid ciliates collected from the freshwater habitats in Korea were identified as Loxophyllum meleagris ($M\ddot{u}ller$, 1773) and Siroloxophyllum utriculariae (Penard, 1922). The description was based on the observation of living and protargol impregnated specimens, and biometric analysis. Their diagnostic characteristics are as follows. L. meleagris; $163-480\times80-100{\mu}m$ in vivo, body shape lancet or knife-like; dorsal margin with 10-19 extrusome warts; 8-35 macronuclei nodules, like a string of bead; 16-21 somatic kineties on right side (including perioral kinety 2, 3) and 6-11 on left side (including perioral kinety 1); 1 contractile vacuole located at posterior part at diastole stage, extending along the dorsal margin toward anterior end with a single long narrow canal. S. utriculariae; $110-170\times78-150{\mu}m$ in vivo, body shape lancet like; dorsal margin without extrusome warts; 2 macronuclei, spherical; 12-19 somatic kineties on right side, 3-7 on left side (including perioral kinety 1); 2-3 contractile vacuoles, first one located anterior ventrally, second one located posterior dorsally and last one located near posterior end of cell.