The Transactions of the Korean Institute of Electrical Engineers C
/
v.52
no.11
/
pp.508-511
/
2003
In this paper, electrical characteristics of inductively coupled plasma in an electrodeless fluorescent lamp were investigated using a Langmuir probe with a variation of argon gas pressure. The RF output was applied in the range of 5 ∼ 50 (W) at 13.56 (MHz). The internal plasma voltage of the chamber and the probe current were measured while varying the supply voltage to the Langmuir probe in the range of -100 (V) ∼+100 (V). When the pressure of argon gas was increased, electric current was decreased. There was a significant electric current increase from l0W to 30 〔W〕. Also, when the RF power was increased, electron density was increase. This implies that this method can be used to find an optimal RF rower for efficient light illumination in an electrodeless fluorescent lamp.
Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
/
1999.05a
/
pp.621-625
/
1999
Rosen type piezoelectric transformer for LCD backlight operated at high voltage and low current, may not be sucessfully used for illuminating general fluorescent lamps because low voltage and high current are required. In this study, the piezoelectric transformer with width vibration mode operated at low voyage and high current was designed for the application of fluorescent lasso ballast. The step-up ratio and efficiency as a function of the load resistance in the piezoelectric transformer indicated that the transformer can be effectively used for the electronic ballast for low profile fluorescent lamp.
Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
/
v.28
no.1
/
pp.1-8
/
2014
The conventional Three-Stage electronic ballast is stable, but Two-Stage electronic ballast has been researching because of efficiency. Three-Stage electronic ballast is consisted of PFC circuit, buck converter, and inverter circuit, but Two-stage is consisted of PFC circuit, Buck-Inverter full bridge circuit. The Buck-Inverter full bridge inverter consists of two half bridge inverters for low frequency switching, and high frequency switching. In the case of street lamp it is far from a lamp to a ballast, the conventional pulsed high voltage ignitor can not turn on the HID lamps because of reduction of ignition voltage. Therefore, it needs to do the research on a resonant ignition to turn on the HID lamps. Therefore, in the Two-Stage electronic ballast which has the resonant tank for ignition, the transient resonant current because of low frequency changing is analyzed, the novel algorithm is proposed to resuce the transient current.
Han Jae Hyun;Lim Young Cheol;Yang Seung Hak;Kweon Gie Hyoun
Proceedings of the KIPE Conference
/
2001.10a
/
pp.80-83
/
2001
As a LCD monitor is larger and thinner, a Cold Cathode Fluorescent Lamp (CCFL) for backlight in LCD monitor gradually becomes longer and thinner. The backlight of a large LCD monitor, however, has a limitation in its brightness. In this study, a parallel multi-lamp is used in order to supply enough brightness. Though the CCFLs are made through a detail and equal manufacturing process, they don't have exactly the same features individually in their brightness, frequency, voltage and current. Consequently, it is difficult to have equal brightness at an early lighting condition or during lighting time. In this paper, a parallel multi-lamp which can have the same output under the same condition is designed. For this, 18 inch LCD monitor with four lamps is used. An inverter for multi-lamp driving is also used in this study. The newly designed inverter shows more than $90\%$ efficiency in its brightness input and output. Besides, it is also available for a multi-drive of other lamps.
Journal of the Korea Academia-Industrial cooperation Society
/
v.12
no.9
/
pp.3795-3801
/
2011
The mathematical simulation of voltage and current waveform of the discharge lamp is useful for the analysis and design of ballasting circuits. This paper proposes a mathematical model which has lamp power and negative voltage drop in discharge lamp. Simulation applying the proposed model has been done, and the results are compared with the experimental results. Furthermore, in the paper, the ballast components(core, transformer) was designed such that high intensity discharge could be optimized for the automotive, by applying a method simulation based design.
Park, Dong-Hyuck;Ha, Seok-Jin;Jung, Hye-Man;Kim, Jong-Hyun;Baek, Ju-Won;Yoo, Dong-Wook;Song, Eui-Ho
The Transactions of the Korean Institute of Power Electronics
/
v.14
no.1
/
pp.31-37
/
2009
Hybrid ballast for field emission lamp with CNT (carbon nano tube) emitter is proposed. Hybrid ballast consists of a high voltage dc part and hi-polar pulse generation part. Field emission lamp with CNT lamp is composed of three electrodes (anode, gate, and cathode). High voltage dc part is for anode and gate and hi-polar pulse generation part is for gate and cathode in CNT triode respectively. The experimental results demonstrate that the proposed topology is good for driving CNT lamp. To protect the lamp and ballast, OCP (Over Current Protection), OVP (Over Voltage Protection), and OTP (Over Temperature Protection) are added and the experimental results demonstrate that the proposed method is good for driving field emission lamp with CNT emitter.
Journal of the Korea Academia-Industrial cooperation Society
/
v.13
no.12
/
pp.6006-6012
/
2012
General solar street light system needs two separate power supply for charging the battery and driving LED Lamp. In this study, one power supply is used for both charging battery and driving LED lamp. In particular, in order to increase the efficiency of the equipment, (maximum power point tracking: MPPT) was applied which is widely adopted in grid-connected solar systems. LED driver embodied using current control routine of charger into Essential constant current system.
Journal of Advanced Marine Engineering and Technology
/
v.38
no.3
/
pp.312-317
/
2014
In this paper, I propose the design technology of LLC resonant converter for the xenon flashlamp that is used to the solid state laser. Through the fabrication of 1.5kW large scale LLC resonant converter, the discharge characteristics are carried out, and introduce the new control method for limiting inrush current by the abrupt load current changes. The mathematical modeling for the lamp discharge includes the internal loss and lamp parameters. I propose the optimal method for the driving conditions of xenon flashlamp from the simulation results comparing the real measurements.
Cho Dae-Youn;Lee Yeon-Jae;Cho Kyu-Min;Oh Won-Sik;Moon Gun-Woo;Lee Sang-Gil;Park Mun-Soo
Proceedings of the KIPE Conference
/
2006.06a
/
pp.409-412
/
2006
EEFL can be driven by square wave driving method. A square wave is applied directly to both ends of EEFL by cascaded multi-stage full-bridge inverter. The various current shapes of lamp are achieved by various inductors between lamp and inverter. In this paper, it is newly investigated that the area of current directly influences the luminance. Furthermore, the 3-level square wave is considered to drive EEFL with self-discharge characteristics. The highest luminance efficiency is achieved by properly controlling the rate of self-discharge usage.
Kim, Il-Kwon;Song, Jae-Yong;Park, Dae-Won;Seo, Hwang-Dong;Kil, Gyung-Suk
Proceedings of the Korean Institute of Information and Commucation Sciences Conference
/
v.9
no.1
/
pp.273-276
/
2005
This paper presents an electronic ballast using a step down converter, a low frequency inverter for high pressure discharge lamp. The proposed ballast is composed of a full-wave rectifier, a step down converter operated as a current source with power regulation and a low frequency inverter with ignition circuit. The ignition circuit generates high voltage pulse of 1${\sim}$2[kV] peak, 130[Hz]. Moreover, it is able to reignite at regular intervals by protective circuit. As experimental results on the test, lamp voltage, current and consumption power are measured 132.5[V], 7.6[A] and 1,005[W], respectively. It was confirmed that the designed ballast operate the lamp with a constant power.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.