• Title/Summary/Keyword: Lamp

Search Result 2,687, Processing Time 0.028 seconds

Fast Lamp Pairing-based Vehicle Detection Robust to Atypical and Turn Signal Lamps at Night

  • Jeong, Kyeong Min;Song, Byung Cheol
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.6 no.4
    • /
    • pp.269-275
    • /
    • 2017
  • Automatic vehicle detection is a very important function for autonomous vehicles. Conventional vehicle detection approaches are based on visible-light images obtained from cameras mounted on a vehicle in the daytime. However, unlike daytime, a visible-light image is generally dark at night, and the contrast is low, which makes it difficult to recognize a vehicle. As a feature point that can be used even in the low light conditions of nighttime, the rear lamp is virtually unique. However, conventional rear lamp-based detection methods seldom cope with atypical lamps, such as LED lamps, or flashing turn signals. In this paper, we detect atypical lamps by blurring the lamp area with a low pass filter (LPF) to make out the lamp shape. We also propose to detect flickering of the turn signal lamp in a manner such that the lamp area is vertically projected, and the maximum difference of two paired lamps is examined. Experimental results show that the proposed algorithm has a higher F-measure value of 0.24 than the conventional lamp pairing-based detection methods, on average. In addition, the proposed algorithm shows a fast processing time of 6.4 ms per frame, which verifies real-time performance of the proposed algorithm.

Development of diagnostic method for human Astrovirus with rapid, specific and high sensitivity using loop-mediated isothermal amplification method

  • Lee, Jin-Young;Rho, Jae Young
    • Korean Journal of Agricultural Science
    • /
    • v.47 no.1
    • /
    • pp.173-182
    • /
    • 2020
  • Human Astrovirus (HuAstV), known as a waterborne virus, is a group IV positive-sense single-stranded RNA that belongs to Astroviridae. The first outbreak of HuAstV was reported in England in 1975. HuAstV can exist not only among clinical patients but also in various water environments, such as water for agriculture and vegetables. For diagnosis of HuAstV from water samples, a polymerase chain reaction (PCR) system has been developed. However, the PCR-based diagnostic method has problems in field application, such as reaction time, sensitivity and specificity. For this reason, in this study we developed the loop-mediated isothermal amplification assay (LAMP) system, aimed specifically at HuAstV. Three prepared LAMP primer sets were tested by specificity, non-specificity and sensitivity; one LAMP primer set was selected with optimum reaction temperature. The developed LAMP primer set reaction conditions were confirmed at 62℃, and detection sensitivity was 1 fg/μL. In addition, restriction enzyme HaeIII (GG/CC) was introduced to confirm that the LAMP reaction was positive. As a result, selected LAMP primer set was 100 - 1000 times more specific, rapid, and sensitive than conventional-nested PCR methods. For verification of the developed LAMP assay, twenty samples of cDNA from groundwater samples were tested. We expect that the developed LAMP assay will be used to diagnose HuAstV from various samples.

Discharge and Luminous Characteristics of Coplanar Type Xe Plasma Flat Lamp (면방전형 Xe 플라즈마 평판 램프의 방전 및 발광 특성)

  • Kim, Hyuk-Hwan;Lee, Won-Jong
    • Korean Journal of Materials Research
    • /
    • v.21 no.10
    • /
    • pp.532-541
    • /
    • 2011
  • The Xe plasma flat lamp, considered to be a new eco-friendly LCD backlight, requires a further improvement of its luminance and luminous efficiency. To improve the performance of this type of lamp, it is necessary to understand the effects of the discharge variables on the luminous characteristics of the lamp. In this study, the luminous characteristics of a coplanartype Xe plasma flat lamp with a teeth-type electrode pattern were analyzed while varying the gas composition, gas pressure and input voltage. The effects of the phosphor layer on the discharge and the luminous characteristics of the lamp were also studied. The luminous efficiency of the coplanar-type Xe plasma flat lamp improved as the Xe input ratio and gas pressure increased. Higher luminous efficiency was also obtained when helium (He) was used as a buffer gas and when a phosphor layer was fabricated on the electrode region. In contrast, the luminous efficiency was reduced with increasing the input voltage. It was found that the infrared emissions from the lamp were affected by the Xe excitation rate in the plasma, the Xe gas density, the collisional quenching of excited Xe species by gas molecules, and the recombination rate between the Xe ions and electrons.

Interior Light Environment and Building Energy Performance Analysis of LED Lamp Installed in Office Building (LED램프를 적용한 사무소 건물의 실내조명환경 및 에너지 성능분석)

  • Kim, Byoung-Soo;Hong, Won-Pyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.5
    • /
    • pp.77-85
    • /
    • 2010
  • In this paper, A new integrated energy simulation results of LED lamp are presented to use it effectively in the office buildings. Generally LED lamp has many advantages in comparison with a general lamp such as long life and no pollution problem like the mercury. It also is excellent in color rendering and small consumption electric power. However LED lamp has some disadvantages to compare to general fluorescent lamp. It is small light flux about 50[%] and narrow light distribution than fluorescent lamp. Therefore, to apply LED lamp in an office building, the illuminance distribution with an environment analysis and cooling, heating and light energy has to be analyzed. The purpose of this study is to analyze light environment, light, cooling and heating energy simulation in office building.

Development of automatic illumination controller for energy saving (에너지 절약형 자동조명 장치 개발)

  • 최명호;강형곤;김민기;한병성
    • Electrical & Electronic Materials
    • /
    • v.9 no.10
    • /
    • pp.1027-1032
    • /
    • 1996
  • The auto-illumination controller for office, residence, and so on was studied. The system consists of parts of a power supply, a signal oscillator, a lamp controller and two kinds of sensor. The lamp controller has two thyristors triggered by the IR sensor(SCRI) and CdS sensor(SCR2) respectively, When the illuminance around this system is higher than operating value of its sensor, lamp is turned off automatically. Otherwise, the light of lamp gets dim by CdS sensor. In case IR sensor senses the body heat of people around itself, the illuminance of the lamp gets maximum. The illuminance of the lamp can be changed dimmly by control of the variable resistor (RV) connected with SCR2 in series. The turning - on time of the lamp can be also controlled using a variable resistor(Rt) connected with a signal oscillator in parallel. Changing resistance Rt changes the time constant(.tau.), which triggers the gate of SCR2. Though people left the surrounding of lamp, the lamp keeps light for a while.

  • PDF

Development of Loop-mediated Isothermal Amplification (LAMP) for Detection of Vibrio alginolyticus (Loop-mediated isothermal amplification (LAMP)법을 이용한 Vibrio alginolyticus의 신속 진단법 개발)

  • Hong, Seung-hyun;Heo, Moon-Soo
    • Journal of Life Science
    • /
    • v.25 no.8
    • /
    • pp.903-909
    • /
    • 2015
  • Loop-mediated isothermal amplification (LAMP), a PCR-based diagnostic method, is based on autocycling strand displacement DNA synthesis in the presence of exonuclease-negative Bst DNA polymerase under isothermal conditions. With the help of four specific primers that recognize six different sequences of a target DNA, LAMP has high specificity in pathogenic identification in a short time. Hence, in the present study, LAMP is used as a diagnostic tool in the identification of the most dreadful aquatic pathogenic species, Vibrio alginolyticus, and to develop species-specific LAMP primers and optimization of LAMP reaction conditions such as annealing temperature, elongation time, and other PCR chemical concentrations, including MgSO4, dNTPs, Betaine, and Bst polymerase. The optimized LAMP primers were also checked for specificity with other Vibrio species, which showed that the designed primers were very specific to V. alginolyticus After the first introduction of a species name like this one, the first part (“Vibrio” in this case) should be abbreviated to only the first letter.only. These are usually the most harmful pathogens of the Vibrio species that appear in shrimp and crabs. The results also revealed that the LAMP assay could be 10-fold more sensitive than conventional PCR in detecting V. alginolyticus. This could be the first report on using a rapid and highly sensitive technique, the LAMP assay, in the effective diagnosis of the pathogenic bacteria V. alginolyticus, which could help in the early detection of diseases, particularly in aquaculture.

An Experimental Study on the a Light Device which Adopt Safety Ultra Constant Dischange Lamp (초정압 방전램프(UCD)를 적용한 안전 조명 장치에 관한 연구)

  • Jeong, Poong-Gi;Kim, Young-Chul
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2010.11a
    • /
    • pp.63-80
    • /
    • 2010
  • This paper describes the development of various lighting equipment adapting Ultra Constant Discharge Lamp that has newly been on commercial supply in the market. Meeting the required conditions of lighting equipment, various types of UCD Lamp equipment with excellent performances could be successfully developed. In order to provide a guideline for the economical lighting product selection, the analyzed data comparison between Hi-pressure Sodium Lamp which has been the most popular lamp for street lighting and UCD Lamp is provided. The conclusions of the study are made as follows; (1) The performance measurement result of UCD Lamp shows excellent Luminous Efficacy as 108Lm/W, daylight-like Color Rendering Index as 90Ra, and the best operating temperature range as $-50^{\circ}C{\sim}+85^{\circ}C$. Comparing to the Hi-pressure Sodium Lamp, UCD could be evaluated as much superior products. (2) In an assembled status with the lighting fixture (Type STB형-60W), UCD Lamp was tested OK for one hour duration at the temperature range form $-50^{\circ}C$ to $+85^{\circ}C$ and the humidity of 98%. The operation at the extremely low temperature can be an excellent feature to enable the export to the cold temperature regions such as Northern Europe and Russia and the specific applications for defense systems and special industry. (3) As UCD Lamp is a genuine Korea made product following Energy-saving and Eco-friendly policy, it should be appreciated as one of the best $CO^2$ reduction Green product.

  • PDF

Effect of Supplemental lighting on the Growth and Flowering of Rosa hybrida 'Nobles' in winter (겨울철 보광이 절화장미 'Nobles'의 생육 및 개화에 미치는 영향)

  • Na, Taek-Sang;Kim, Jeung-Gun;Choi, Kyong-Ju;Gi, Gwang-Yeon;Yoo, Yong-Kweon
    • Journal of Bio-Environment Control
    • /
    • v.16 no.2
    • /
    • pp.130-134
    • /
    • 2007
  • This study was carry out to investigate the effect of supplemental lighting on the growth and flowering of Rosa hybrida 'Nobles' in winter. Supplemental lighting was treated during 5 hours at night with sodium lamp and fluorescent lamp, and cut flowers harvested 2 times for the experimental period. After supplemental lighting, air temperature and slab temperature in glasshouse was higher in sodium lamp treatment than control. Realtive humidity was low in sodium lamp treatment. Total nitrogen phosphate, potassium, calcium, and magnesium contents of stem in sodium lamp treatment were higher compare to the other treatment. In sodium lamp treatment, the potassium and magnesium content of leaf in control were lower than the others. Chlorophyll content was not different by source of lighting. Stem length and diameter was longer in sodium lamp treatment. In two times, the yield was highest in sodium lamp treatment. Therefore, supplemental lighting with sodium lamp in winter season was recommended for improving the yield and quality in cut rose 'Nobles'.

Predicting of Ignition Time and Critical Distance for Ignition of Douglas fir by Radiant Heat of Incandescent Lamp (백열전구 복사열에 의한 미송판의 발화 임계거리 및 발화시간 예측)

  • Lee, Heung-Su;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.2
    • /
    • pp.18-25
    • /
    • 2016
  • The incandescent lamp is an electric light fixture with a tungsten filament heated to a high temperature, by passing an electric current through it, until it glows with visible light. The hot filament is protected from oxidation with a glass bulb that is filled with inert gas. The incandescent lamp has fire risk when combustible materials are close to its glass bulb. Because its lamp has the property which converts 90~95 percents of the electric power to heat energy. 2015 national fire statistics show that fires caused by lighting fixtures were 652 cases, and incandescent lamps(44 cases) and halogen lamps(53 cases) accounted for 15 percents in those of high heating light fixtures. Since incandescent lamp fires account for about 45 percents in the high heating light fixture, we could not overlook the fire risks by the incandescent lamp. Although many studies related with those have been conducted, incandescent lamp fires are continuously occurred. This study was carried out to study the fire risk of ignition of wood due to radiant heat of incandescent lamp. Radiant heat flux of the incandescent lamp was predicted by applying point source model, and critical distance for ignition of wood was calculated by applying integral model. The results from this study could applied to fire prevention activities related to light bulb, and it could be used in fire cause investigations related to radiant heat of incandescent lamp.

Construction of NCAM-LAMP Precipitation and Soil Moisture Database to Support Landslide Prediction (산사태 예측을 위한 NCAM-LAMP 강수 및 토양수분 DB 구축)

  • So, Yun-Yeong;Lee, Su-Jung;Choi, Sung-Won;Lee, Seung-Jae
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.22 no.3
    • /
    • pp.152-163
    • /
    • 2020
  • The present study introduces a procedure to prepare and manage a high-resolution rainfall and soil moisture (SM) database in the LAMP prediction system, especially for landslide researchers. The procedure also includes converting the data into spatial resolution suitable for their interest regions following proper map projection methods. The LAMP model precipitation and SM data are quantitatively and qualitatively evaluated to identify the model prediction characteristics using the ERA5 reanalysis precipitation and observed 10m depth SM data. A detailed process of converting LAMP Weather Research and Forecasting (WRF) output data for 10m horizontal resolution is described in a step-wise manner, providing technical convenience for users to easily convert NetCDF data from the WRF model into TIF data in ArcGIS. The converted data can be viewed and downloaded via the LAMP website (http://df.ncam.kr/lamp/index.do) of the National Center for AgroMeteorology. The constructed database will contribute to monitoring and prediction of landslide risk prior to landslide response steps and should be data quality controlled by more observation data.