• 제목/요약/키워드: Ladder safety

Search Result 38, Processing Time 0.022 seconds

Development of PLC modules for the safety verification of chemical processes (공정의 안전 검증을 위한 PLC 모듈 개발)

  • Jeong, Sang-Hun;Lee, Kwang-Soon;Moon, Il
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.2 no.1
    • /
    • pp.53-59
    • /
    • 1996
  • An automatic verification method has been studied to determine the safety and operability of programmable logic controller (PLC) based systems. For the systematic and efficient verification, we have developed a conversion method from relay ladder logic (RLL) to the verification system description. RLL is a common representation used to document PLC programs for the sequential logic of the system such as the safety interlocks and the startup/shutdown procedures. Once the modules are developed, complex RLLs can be represented by the combination of modules. As a result we can verify complex PLC systems using the verification method including RLL modules. The developed modules are used to verify alarm systems and show that the method is valid.

  • PDF

A Random Forest Algorithm-based Accident Prediction to Prevent Marine Pilot Occupational Accidents

  • Gokhan Camliyurt;Won Sik Kang;Daewon Kim;Sangwon Park;Youngsoo Park
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2022.06a
    • /
    • pp.415-416
    • /
    • 2022
  • Marine pilot occupational accidents during transfer to/from the ship are at the top of the agenda after several safety campaigns by IMPA and individual attemptsThere is multiple transfer method for the marine pilot, but a most common way is to use the pilot cutter. This paper aims to predict marine pilot occupational accidents before it occurs by using historical data. Since the problem depends on several variables, this paper develops a model by using the random forest method to predict marine pilot accidents before happening with the random forest method by using RStudio software

  • PDF

An Experimental Study of SL Shear Reinforcement for Reinforced Concrete Flat Plate Slab (철근콘크리트 무량판 슬래브의 일체형 SL(Shear Ladder) 전단보강재에 관한 실험적 연구)

  • Woo, Jong-Yeol;Hong, Seong-Wook;Park, Seung-Hwan;Kim, Shin;Shin, Chan-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05b
    • /
    • pp.53-56
    • /
    • 2011
  • This study is concerned with the SL shear reinforcement that it can be installed easily in filed as product at the factory and seismic performance can be achieved. The method of study is as follows. first, we researched constructability and economy of existing method. Secondly, we made specimen and were examined structural performance tests in order to verify the performance of the shear reinforcement. Shear strength of HILL01-HILL03 specimen applied to SL shear reinforcement increased about 5-14% when compared with the applied shear stirrup reinforcing existing specimens. Also, the amount of the maximum deflection of the central sub-section of HILL01-HILL03 specimen applied to SL shear reinforcement decreased about 41-42% when compared with the applied shear stirrup reinforcing existing specimens. As a result, developed SL shear reinforcement increased in shear strength and stiffness of reinforcement, structural safety is judged to be increased.

  • PDF

The Lightweight and the Self-escape Function Development of the SRL (SRL의 경량화 및 자가탈출기능 개발)

  • Kim, Sang Tae;Kwon, Oh Heon;Kang, Ji Woong
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.6
    • /
    • pp.15-21
    • /
    • 2014
  • Many kinds of falling prevention systems with a safety block have been supplied in order to prevent falling accidents and acquire the long life and cost down for the maintenance. However, there are not the reliable and domestic the falling prevention system until now. Almost systems were imported from U.S.A, Japan, U.K and Germany. The structural safety of the imported safety block is satisfied sufficiently, but it has heavy weight due to the cover with the aluminum and thickness. Especially, the falling prevention system as the safety block is very expensive. It brings about flow the enormous money out of country. Furthermore it has a heavy weight when workers climbed the ladder with a falling prevention system and moved, many workers are not feeling themselves. Thus, the aim of this work is to develop a commercial self-escape SRL(Self Retracting Lifeline) with the safety block function that has a light weight and an advanced strength. The cost efficiency and convenience of the system and safety for workers also will be improved remarkably even though this system has a light weight. The results show that the maximum stress is obtained in each part by the lower more than yield strength and has sufficient safety in the developed new safety block.

Estimation of citizen's willingness to pay for water quality improvement on urban rivers (도시하천 수질개선을 위한 시민의 지불의사액 추정 연구)

  • Kang, Jiyoon;Yang, Jinwoo;Hwang, Youngsoon;Kim, Keewook
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.3
    • /
    • pp.225-233
    • /
    • 2023
  • Urban rivers and their surrounding environments have been altered due to factors such as rapid economic growth and urban development. This alteration have caused the rivers to lose their original value and become exposed to various pollution, resulting decrease in citizens' quality of life. This study aims to estimate citizens' Willingness To Pay (WTP) for water quality improvement in Suyeong River in Busan. To estimate the non-market value of the Suyeong River, the WTP of Busan citizens for water quality improvement was estimated, applying Contingent Valuation Method (CVM). The WTP for improving the water quality from Grade 4(polluted water) to Grade 2(game fish like bass can live in it) was estimated using the water quality ladder concept of the US Environmental Protection Agency, assuming annual donations for five years. For the CVM, the logistic distribution and Spike Model were adopted. As a result, citizens residing in the surrounding area of Suyeong River expressed a higher WTP. Considering more than half of the Busan citizens are aware of the "conservation of nature and ecosystems" as a major function of the Suyeong River, this higher WTP could serve as a basis for improving the value of urban rivers.

Evaluation of Overturning Stability for Preventing Safety Accidents Caused by Ladder Work in Landscape Construction and Management - For the Tripod Support Portable Ladders Used in Korea - (조경시공·관리에서 사다리 안전사고 예방을 위한 전도 안정성 평가 - 국내에서 사용되고 있는 삼각지지형 이동식 사다리를 대상으로 -)

  • Kim, Eun-Il;Kwon, Yoon-Ku;Lee, Gi-Yeol
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.51 no.5
    • /
    • pp.1-12
    • /
    • 2023
  • This study evaluated the overturning stability of portable tripod ladders used for high-altitude work such as tree management and pruning work in landscaping construction and management. Portable tripod ladders, which are included in general mobile or portable ladders frequently used in industrial sites, are supported in a triangular support structure, not a 4-point support like common A-type Ladders. In addition, since the working height is more than twice that of a mobile or portable ladder, the possibility of an overturning accident that threatens the safety of workers with a fall accident is high. Therefore, based on the overturning stability test specified in ANSI-ASC A14.7 and EN 131-Part 7, which are related standards for about 130 types of portable tripod ladders sold and used in Korea. An equation to calculate each moment according to working height was derived. Then, each calculated moment was compared to evaluate the safety factor for overturning and stability. As a result of the overturning stability evaluation according to each standard, when the provisions of EN 131-Part 7 were applied, portable tripod ladders with 8 steps in the rear direction and 6 steps or more in the side direction were evaluated as unstable against overturning, but according to ANSI-ASC A14.7 regulations. It was evaluated that the stability against overturning was secured in all directions and number of steps.

A Study on incident related to pilot at Korea (우리나라 항만 도선사 준사고에 관한 연구)

  • Sangwon Park;Byoung Jae Yoon;Youngsoo Park
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2022.11a
    • /
    • pp.57-58
    • /
    • 2022
  • Pilots are always exposed to unpredictable risks of the marine environment because they are boarding the ship through pilot ladders or gangways at sea. Since the pilot plays an important role in securing the safety of ships entering or departing from the port, the injury of the pilot greatly affects the overall safety of the ship. The purpose of this study is to analyze pilot incidents and predict accidents. For this purpose, the pilot injury accident cases are analyzed and potential situations are identified through a survey. And the pilot injury accident was predicted. The results can be used as basic data for prevention of pilot-related accidents.

  • PDF

Follow-Up Survey Fire Truck Deterioration (소방자동차 노후화에 따른 고장 발생원인 추적조사 연구)

  • Lee, Jang-Won;Kim, Eui-Tae;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.29 no.3
    • /
    • pp.59-64
    • /
    • 2015
  • This study analyzed results of the causes of failure in 1,022 fire trucks currently being used in South Korea (aerial ladder, aerial platform, pumper, and chemical fire trucks). The results show that 46% of aerial ladder trucks have defective in the elevator brake systems, 29% of aerial platform trucks have contamination in the hydraulic oil, 37% of pumpers have defective in the pneumatic cylinders of the air supply system, and 39% of chemical fire trucks have defective in the powder fire extinguishing systems. The principal reasons for malfunctions are deterioration of the apparatuses, and accumulated fatigue from repetitive use of certain components, such as pneumatic cylinders in the air supply system and wire rope jamming in rollers in the ladder apparatus. These manufacturing defects should be improved upon in the manufacturing process. As a result, the fire trucks, which are used for 5 years or more, need precise inspections in accordance with the Regulation on Fire Apparatus Maintenance. Fire apparatuses have a service life of 10 to 12 years or more. They need to be replaced or require life extension, and they should be kept in top shape with the best maintenance for public safety.

Measures to Ensure Overturning Stability of Tripod Mobile Ladders Used in Landscape Construction and Management - On Tripod Mobile Ladders Used in Korea Subject to EN131-Part 7 - (조경시공·관리에 사용되는 삼각지지 이동식 사다리의 전도 안정성 확보 대책 - EN131-Part 7 규정을 적용한 국내 삼각지지 이동식 사다리를 대상으로 -)

  • Lee, Kang-Hyeon;Lee, Gi-Yeol
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.52 no.3
    • /
    • pp.76-88
    • /
    • 2024
  • A significant cause of fall or overturning accidents in the construction industry, including landscaping construction and management, is work at heights using portable ladders. Portable ladders are classified as A-type or triangular support ladders depending on the number of supporting leg and support conditions. The tripod mobile ladder, which supports itself with only three supporting legs, is unstable and more prone to overturning compared to the A type ladders. Therefore, using the specifications of the tripod mobile ladder and the stability regulations of EN131-Part 7, overturning and resistance moment calculation formulas were derived for all directions in which overturning could occur. The moments calculated using these equations, and the overturning stability in each direction were evaluated. According to the calculation results, although there are differences depending on the direction, most are unstable for overturning at 8 or more steps. Based on these results, this study proposed measures to increase the moment of resistance by changing the weight, depth, and width, and using outriggers to ensure stability against the overturning of ladder. However, when changing the specifications of these measures, the size increases are excessive and the applicability is insufficient. On the other hand, outriggers are an applicable measure as they can ensure stability against overturning with only a minimum expansion length.

An Experimental Study of Vertically Suspended Shear Reinforcement for Reinforced Concrete Flat Plate slab (철근콘크리트 무량판 슬래브의 수직걸림형 전단보강재에 관한 실험적 연구)

  • Woo, Jong-Yeol;Hong, Seong-Wook;Doh, Sun-Boong;Kim, Sang-Won
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.05a
    • /
    • pp.173-174
    • /
    • 2012
  • This study is concerned with the VSTUD shear reinforcement that it can be installed easily in filed as product at the factory and seismic performance can be achieved. The method of study is as follows. first, we researched constructability and economy of existing method. Secondly, we made specimen and were examined structural performance tests in order to verify the performance of the shear reinforcement. As a result, developed SL shear reinforcement increased in shear strength and stiffness of reinforcement, structural safety is judged to be increased.

  • PDF