• Title/Summary/Keyword: Laboratory tests

Search Result 3,861, Processing Time 0.033 seconds

Cesium Radioisotope Measurement Method for Environmental Soil by Ammonium Molybdophosphate (환경토양에서 몰리브도인산 암모늄을 이용한 세슘 동위원소 평가방법)

  • Choe, Yeong-hun;Seo, Yang Gon
    • Clean Technology
    • /
    • v.22 no.2
    • /
    • pp.122-131
    • /
    • 2016
  • Caesium radioisotopes, 134Cs and 137Cs which come from the atmospheric nuclear tests and discharges from nuclear power plants, are very important to study artificial radioactivity. In this work, in order to lower the minimum detection activity (MDA) we investigated environmental radioactivity according to the Environment Measurement Laboratory procedure by 137Cs and 134Cs which is similar to chemical and environmental behaviors of 137Cs. The environmental soils in high mountain areas near nuclear power plant were collected, and an Ammonium Molybdophosphate (AMP) precipitation method, which showed high selectivity toward Cs+ ions, was applied to chemically extract and concentrate Caesium radioisotopes. Radioactivity was estimated by a gamma-ray spectrometry. In gamma energy spectrum, with an increasing of 40K radioactivity, it increased the MDA of 134Cs and 137Cs. Therefore, if the natural radionuclides were removed from the soil samples, the MDA of Caesium may be reduced, and the contents of 137Cs of in the environmental soils can effectively be estimated. In the standard soil sample of Korea Institute of Nuclear Safety, radioactivity of 40K was removed more than 84% on average, and the MDA of 134Cs was reduced 2 times. The content of 137Cs was recovered over 84%. On the other hand, in environmental soils, AMP precipitation method showed removal ratio of 40K up to 180 times, which reduced the MDA about 5 times smaller than those of Direct method. 137Cs recovery ratio showed from 54.54% to 70.06%. When considering the MDA and recovery ratio, AMP precipitation method is effective for detection of Caesium radioisotopes in low concentration.

Evaluation Methods of Compression Index and the Coefficient of Consolidation by Back Analysis of Settlement Data (현장계측치로부터 역산한 압축지수와 압밀계수의 평가 방법)

  • Lee, Dal Won;Lim, Seong Hun;Kim, Ji Moon
    • Korean Journal of Agricultural Science
    • /
    • v.27 no.1
    • /
    • pp.39-47
    • /
    • 2000
  • A large scale field test of prefabricated vertical drains is performed to analyze the effect of parameters of the very soft clay at a test site. Compression index and the coefficient of horizontal consolidation obtained by back-analysis from the settlement data were compared with those obtained by means of laboratory tests. The Hyperbolic, Asaoka's and The Curve fitting methods are used to estimate final settlements and coefficients of consolidation. 1. Final settlement predicted with the Hyperbolic method was the largest, and the settlements predicted with the Asaoka's and the Curve fitting methods were nearly the same range, and it was concluded that smear effect has to be considered on design in the case that spacing of drains is small 2. The relationships of the measured consolidation ratio (Urn) and the designed consolidation ratio($U_t$) were showed as $U_m$ = (1.13~1.17)$U_t$, $U_m$ = (1.07~1.20)$U_t$, $U_m$ = (1.13~1.17)$U_t$ on the Hyperbolic, Asaoka's and the Curve fitting methods, respectively. The relations on the Asaoka's and the Curve fitting methods were nearly the same range. 3. The relationships of the field compression index($C_{cfield}$) and virgin compression index($V_{cclab}$) were showed as $C_{cfield}$ = (1.26~1.45)$V_{cclab}$, $C_{cfield}$ = (1.08~1.15) $V_{cclab}$, $C_{cfield}$ = (1.04~1.21)$V_{cclab}$, on the Hyperbolic, Asaoka's and the Curve fitting methods, respectively. 4. The ratio ($C_h/C_v$) of the coefficient of vertical consolidation and the coefficient of horizontal consolidation that is obtained by back-analysis from the settlement data was $C_h$=(0.7~0.9)$C_v$, $C_h$=(0.9~1.5)$C_v$, $C_h$=(2.4~3.0)$C_v$ on the Hyperbolic, Asaoka's and the Curve fitting methods, respectively. 5. It was concluded that the exact consolidation coefficient must be determined after the final settlement is predicted again when the consolidation is finished, because the field consolidation coefficient is decreased as the time allowed to be alone is increased.

  • PDF

Analysis of Groundwater Flow Characterization in Fractured Aquifer System (파쇄대 응회암 대수층의 지하수 유동 특성화 기법)

  • Kim Yong-Je;Kim Tae-Hee;Kim Kue-Young;Hwang Se-Ho;Chae Byung-Gon
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.4
    • /
    • pp.33-44
    • /
    • 2005
  • On the basis of a stepwise and careful integration of various field and laboratory methods the analysis of groundwater flow characterization was performed with five boreholes (BH-1, -2, -3, -4, -5) on a pilot site of Natural Forest Park in Guemsan-gun, Chungcheongbook-do, Korea. The regional lineaments of NW-SE are primarily developed on the area, which results in the development of many fractures of NW-SE direction around boreholes made in the test site for the study. A series of surface geological survey, core logging, geophysical logging, tomography, tracer tests, and heat-pulse flowmeter logging were carried out to determine fracture characteristics and fracture connectivity between the boreholes. In the result of fracture connectivity analysis BH-1 the injection well has a poor connectivity with BH-2 and BH-3, whereas a good with BH-4 and BH-5. In order to analyse the hydraulic connectivity between BH-1 and BH-5, in particular, a conspicuous groundwater outflux in the depth of 12 m and influx in the depth of 65 m and 70 m, but partly in/outflux occurred in other depths in BH-5 were observed as pumping from BH-1. On the other hand, when pumping from BH-5 the strong outflux in the depths of 17 m and 70 m was occurred. The spatial connectivity between the boreholes was examined in the depth of 15 m, 67 m, and 71 m in BH-1 as well as in the depth of 15 m, 17 m, 22 m, 72 m, and 83 m in BH-5.

Development of a High Heat Load Test Facility KoHLT-1 for a Testing of Nuclear Fusion Reactor Components (핵융합로부품 시험을 위한 고열부하 시험시설 KoHLT-1 구축)

  • Bae, Young-Dug;Kim, Suk-Kwon;Lee, Dong-Won;Shin, Hee-Yun;Hong, Bong-Guen
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.4
    • /
    • pp.318-330
    • /
    • 2009
  • A high heat flux test facility using a graphite heating panel was constructed and is presently in operation at Korea Atomic Energy Research Institute, which is called KoHLT-1. Its major purpose is to carry out a thermal cycle test to verify the integrity of a HIP (hot isostatic pressing) bonded Be mockups which were fabricated for developing HIP joining technology to bond different metals, i.e., Be-to-CuCrZr and CuCrZr-to-SS316L, for the ITER (International Thermonuclear Experimental Reactor) first wall. The KoHLT-1 consists of a graphite heating panel, a box-type test chamber with water-cooling jackets, an electrical DC power supply, a water-cooling system, an evacuation system, an He gas system, and some diagnostics, which are equipped in an authorized laboratory with a special ventilation system for the Be treatment. The graphite heater is placed between two mockups, and the gap distance between the heater and the mockup is adjusted to $2{\sim}3\;mm$. We designed and fabricated several graphite heating panels to have various heating areas depending on the tested mockups, and to have the electrical resistances of $0.2{\sim}0.5$ ohms during high temperature operation. The heater is connected to an electrical DC power supply of 100 V/400 A. The heat flux is easily controlled by the pre-programmed control system which consists of a personal computer and a multi function module. The heat fluxes on the two mockups are deduced from the flow rate and the coolant inlet/out temperatures by a calorimetric method. We have carried out the thermal cycle tests of various Be mockups, and the reliability of the KoHLT-1 for long time operation at a high heat flux was verified, and its broad applicability is promising.

Studies on the Simplified Hemagglutination Reaction to Pasteurella multocida and the Stabilization of Erythrocytes (Pasteurella multocida에 대(對)한 간이적혈구(簡易赤血球) 응집반응(凝集反應)과 적혈구(赤血球)의 안정화(安定化)에 관(關)한 연구(硏究))

  • Lee, Hak Cheul;Chung, Yung Gun;Kim, Kyo-Joon
    • Korean Journal of Veterinary Research
    • /
    • v.10 no.1
    • /
    • pp.11-23
    • /
    • 1970
  • Recently Carter(1952) reported the capsule antigens of Pasteurella multocida could be divided into four serological types A,B,C and D by means of precipitation tests. Subsequently he showed that the most sensitive for identification of these types involved the use of capsule substance adsorbed by erythrocytes in hemagglutination test. It may be somewhat difficult to conduct the hemagglutination test in small laboratory, because relatively large amounts of antisera and erythrocytes of the human O type are required for the test. A simple method for serological typing of P. multocida was the slide agglutination test employed by Little et al. (1943) and Namioka et al. (1962), but this method is still in controversy. The author tried adapting Carter's hemagglutination method to the slide method so called "micromethod technique", and studied on the stabilization of erythrocytes for use of slide hemagglutination to P. multocida although many invesigators reported the stabilization of erythrocytes. The results obtained are summarized as follows: 1. A simplified method (slide method) for capsule typing of the organism was developed by adapting Carter's hemagglutination reaction(tube method). Antibody-containing serum can be diluted serially on Boerner's microtest slide with capillary or serological pipetts with a considerable accuracy. The slide reaction can be carried out with case on the slide by adding $0.05m{\ell}$ of antigen-sensitized erythrocytes suspension diluted to one percent on $0.05m{\ell}$ of serially diluted antibody-containing sera, and the final result can be read after 60 minutes at the room temperature ($15^{\circ}C$). 2. It is difficult to determine superiority of inferiority between the slide method and the tube method on the pattern of the reaction of hemagglutination. 3. The pH range of 6.6 to 8.3 is optimal for the slide hemagglutination reaction. 4. The antigen-sensitization against erythrocytes at $37^{\circ}C$ is optimal for the slide hemagglutination. 5. Both the doses and concentration of antigen do not influence the antigen-adsorbing capacity of erythrocytes. 6. The reduction of antigen-sensitizing hours does not influence the antigen-adsorbing capacity of erythrocytes even 30 minutes. 7. The tannic acid treatment against formalinized and non-formalinized erythrocytes showed no effect on the reaction of hemagglutination. 8. The erythrocytes preserved at $4^{\circ}C$ in the ACD solution do not decrease the reactivity on the reaction of hemagglutination for 60 days, while they begin slight hemolysis 30 days after preserving. 9. The stable preparation of erythrocytes can be obtained by treating the cells at $37^{\circ}C$ for 20 hours with from 4 to 8 percent of formalin in saline or buffer. These cells can be preserved at $4^{\circ}C$ for more than 8 months experimented without hemolysis. With low concentration of formalin, the cells were not sufficiently stabilized resulting in the hemolysis after short period of preservation at $4^{\circ}C$. 10. The erythrocytes treated with 16 percent of formalin remain constantly or increase the reactivity for the reaction of hemagglutination. On the contrary, the cells treated with I to 8 percent of formalin decrease the reactivity. 11. There is no difference between nontreated fresh erythrocytes and the erythrocytes preserved in the ACD solution on the reactivity against the hemagglutination, and the erythrocytes treated with 16 percent of formalin showed the reactivity of higher level than that of the above two kinds of erythrocytes. 12. There is no difference between the saline and the isotonic buffer solution on the reaction of hemagglutination.

  • PDF

Toxicity of Organic Waste-Contaminated Soil on Earthworm (Eisenia fetida) (유기성 폐기물에 의해 오염된 토양이 지렁이에게 미치는 독성)

  • Na, Young-Eun;Bang, Hae-Son;Kim, Myung-Hyun;Lee, Jeong-Taek;Ahn, Young-Joon;Yoon, Seong-Tak
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.40 no.1
    • /
    • pp.51-56
    • /
    • 2007
  • The toxicities of contaminated soils with 8 consecutive year applications of three levels (12.5, 25.0, and $50.0t\;dry\;matter\;ha^{-1}yr^{-1}$) of four organic sludge [municipal sewage sludge (MSS), industrial sewage sludge (ISS), alcohol fermentation processing sludge (AFPS) and leather processing sludge (LPS)] on earthworm (Eisenia fetida) were examined by using microcosm container in the laboratory. Results were compared with those of pig manure compost (PMC) treated soil. In tests with three treatment levels (12.5, 25.0, and 50.0 t per plot), ISS treated soil showed higher contents of Cu (18.9~26.2 fold), Cr (7.7~34.7 fold), and Ni (14.8~18.8 fold) at 8 years post treatment, than PMC treated soil. LPS treated soil showed higher contents of Cr (35.7~268.0 fold) and Ni (4.5~7.6 fold) than PMC treated soil. There were no great differences in heavy metal contents among MSS, AFPS, and PMC treated soils. In these contaminated soils, earthworm mortalities of MSS and AFPS treated soils at 8 weeks post-exposure were similar to those of PMC treated soil regardless of each treatment level. Toxic effect (26.7~96.7 mortality) on the ISS and LPS treated soils was significantly higher than one of PMC treated soil, with an exception of LPS soil treated with 25.0 t per plot. At 16 weeks post-exposure, earthworm mortalities of AFPS' 12.5 and 25.0 t treated soils were similar to those of PMC treated soil. Toxic effect (53.3~100 mortality) on the 12.5, 25.0, and 50.0 t treated soils of MSS, ISS and LPS, and AFPS' 50.0 t treated soils was significantly higher than those of PMC treated soil. The data suggested that the 12.5, 25.0, and 50.0 t of MSS, ISS and LPS, and AFPS' 50.0 t treated soils were evaluated to have toxicity on earthworm.

18-year Follow-up of Extended Newborn Screening for Metabolic and Endocrine Disorders (대사 및 내분비 질환에 대한 광범위 신생아 선별 검사의 18년 추적 관찰)

  • Song, Wung Joo;Lee, Sunho;Jeon, Young Mi;Kim, Sook Za;Jang, Mea Young
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.18 no.2
    • /
    • pp.35-42
    • /
    • 2018
  • Purpose: To follow up Korean patients with metabolic and endocrine disorders ascertained by Korea Genetics Research Center, and assess the long-term effectiveness of extended newborn screening program in Korea. Methods: From January 2000 to December 2017, tandem mass spectrometry and fluoroimmunoassay were employed in extended newborn screening (NBS). The NBS program obtained dried blood spots from 283,626 babies, 48 hours after birth, and screened for galactosemia, congenital hypothyroidism (CH), congenital adrenal hyperplasia (CAH), and 50 preventable inborn errors of amino acid, fatty acid, and organic acid metabolism. Results: 28 cases of amino acid disorders, 75 cases of organic acid disorders, 27 cases of fatty acid disorders, 51 cases of urea cycle disorders, 127 cases of CH, 14 cases of CAH, and 15 cases of galactosemia were ascertained through NBS and subsequent confirmatory laboratory tests. Patients with amino acid metabolic disorders, galactosemia, CH, or CAH were more likely to have a better long-term outcome if detected early. Early management of MSUD led to much better outcome in over 90%. Despite early intervention, 32% of other organic acidemia cases still resulted in developmental delay and neurological problems. Fatty acid disorders showed varied results; those with EMA and MCAD had a good outcome, but those with VLCAD had serious neurological problems and considerably higher mortality. 75% with UCD experienced serious neurological complications and higher mortality. Conclusion: The nation-wide NBS program must be accompanied by comprehensive long-term management and physician and family education of inborn errors of metabolism for a better outcome.

  • PDF

Comparison Analysis of The results of IRMA Test among Different Equipment According to Algorithm change. (IRMA 검사법 중 알고리즘 변경에 따른 장비 간 결과값 비교분석)

  • Kim, Jung In;Kwon, Won Hyun;Lee, Kyung Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.43-50
    • /
    • 2019
  • Purpose The principle of nuclear medicine test is divided into two main categories: competition(radioimmunoassay, RIA) and noncompetitive reaction(Immunoradiometric assay, IRMA). It is known that the curve fitting method, which is commonly used in inspection field, uses Spline interpolation in RIA method and Linear interpolation method in IRMA method. Among them, the insulin test using the IRMA test showed a significant difference, especially at low concentrations, despite the same algorithm of linear interpolation between fully automated radio immunoassay analyzers. In this study, we aim to obtain results from applying two different of algorithm using fully automated radio immunoassay analyzers including Gamma pro, Gamma 10, Cobra, and SR300. Materials and Methods A total of 30 test samples were selected for the test of TSH, ferritin, C-peptide, and insulin serum levels. Test was performed by IRMA method. We compared the difference in the results of applying the linear interpolation method and the spline interpolation method to Gamma Pro, Gamma 10, Cobra, and SR300 equipment. Results Two-way ANOVA was used for statistical analysis. The significance level was applied as P <0.05. The results of TSH, ferritin, C-peptide, and insulin tests were compared between the fully automated radio immunoassay analyzers. There was a significant difference between ferritin, C-peptide, and insulin serum levels(P<0.001). TSH didn't show any significant different between the devices(P=0.29). In the difference between linear and spline interpolation, there was no significant difference between insulin test(P=0.08), TSH test(P=0.81), and Ferritin test(P=0.06). However, C-peptide test showed a significant difference(P=0.03). Especially, the insulin test showed significant difference in lower ranges. As a result of comparing and analyzing the difference between the two interpolation methods, the devices in the low concentration group showed significant difference(P<0.001). Conclusion In case of new equipment in the laboratory it is necessary to recognize that there is a difference in the curve fitting method for each automated radio immunoassay analyzers in the low concentration area when the principle of inspection is IRMA method.

Nationwide "Pediatric Nutrition Day" survey on the nutritional status of hospitalized children in South Korea

  • Lee, Yoo Min;Ryoo, Eell;Hong, Jeana;Kang, Ben;Choe, Byung-Ho;Seo, Ji-Hyun;Park, Ji Sook;Jang, Hyo-Jeong;Lee, Yoon;Chang, Eun Jae;Chang, Ju Young;Lee, Hae Jeong;Kim, Ju Young;Lee, Eun Hye;Kim, Hyun Jin;Chung, Ju-Young;Choi, You Jin;Choi, So Yoon;Kim, Soon Chul;Kang, Ki-Soo;Yi, Dae Yong;Moon, Kyung Rye;Lee, Ji Hyuk;Kim, Yong Joo;Yang, Hye Ran
    • Nutrition Research and Practice
    • /
    • v.15 no.2
    • /
    • pp.213-224
    • /
    • 2021
  • BACKGROUND/OBJECTIVES: To evaluate the nutritional status and prevalence of malnutrition in hospitalized children at admission and during hospitalization in South Korea. SUBJECTS/METHODS: This first cross-sectional nationwide "Pediatric Nutrition Day (pNday)" survey was conducted among 872 hospitalized children (504 boys, 368 girls; 686 medical, 186 surgical) from 23 hospitals in South Korea. Malnutrition risk was screened using the Pediatric Yorkhill Malnutrition Score (PYMS) and the Screening Tool Risk on Nutritional status and Growth. Nutritional status was assessed by z-scores of weight-for-age for underweight, weight-for-height for wasting, and height-for-age for stunting as well as laboratory tests. RESULTS: At admission, of the 872 hospitalized children, 17.2% were underweight, and the prevalence of wasting and stunting was 20.2% and 17.3%, respectively. During hospitalization till pNday, 10.8% and 19.6% experienced weight loss and decreased oral intake, respectively. During the aforementioned period, fasting was more prevalent in surgical patients (7.5%) than in medical patients (1.6%) (P < 0.001). According to the PYMS, 34.3% and 30% of the children at admission and on pNday, respectively, had a high-risk of malnutrition, requiring consultation with the nutritional support team (NST). However, only 4% were actually referred to the NST during hospitalization. CONCLUSIONS: Malnutrition was prevalent at admission and during hospitalization in pediatric patients, with many children experiencing weight loss and poor oral intake. To improve the nutritional status of hospitalized children, it is important to screen and identify all children at risk of malnutrition and refer malnourished patients to the multidisciplinary NST for proper nutritional interventions.

The Validation of a Commercial Testosterone RIA Test Kits (Testosterone RIA 검사 kit 별 유효성 비교평가)

  • Ryu, Hwa-jin;Shin, Seon-yeong;Cho, Seong-uk
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.1
    • /
    • pp.38-41
    • /
    • 2022
  • Purpose Testosterone is a steroid hormone synthesized by the Leydig cells of the testes in men, and by the adrenal cortex and ovaries in women. Testosterone production is regulated by luteinzing hormone secreted by the anterior pituitary gland. In this experiment, the effectiveness of testosterone radioimmunoassay (RIA) kits produced by three companies was evaluated and compared in case the production of testosterone kits was stopped or supply problems occurred. Materials and Methods In October 2021, samples were collected from the patients (n=49) who requested the testosterone RIA test. The experiment was conducted by dividing the patient's sample into low concentration (1.0 ng/mL or less), medium concentration (2.0-4.0 ng/mL) and high concentration (6.0 ng/mL or more). The Testosterone RIA test compared and evaluated the validity of Company A kits used in this hospital and those of Company B and C used in other hospitals. The precision, sensitivity, recovery, linearity and correlation were evaluated for each kit. The testosterone RIA test was carried out in accordance with the insert kit manual for each manufacturer. Results As a result of measuring the precision of the intra assay, the Coefficient of Variation (CV) value of the company A kit was high at 11.4% only in the low concentration sample, and in the case of the company B and C kits, the CV value was less than 10% at low, medium, and high concentrations. In the inter-assay precision measurement, the CV value was less than 15% in both A and C kits, but in the case of the B kit, the CV value exceeded 15% at low and medium concentrations. Sensitivity was 0.13 ng/mL for company A, 0.01 ng/mL for company B, and 0.01 ng/mL for company C, and the linearity of all three kits showed excellent linearity. In the case of recovery rate, all of the A, B, and C company kits showed results that were out of 90-110%. In the case of correlation test, when compared with the company A kit currently use in here, the correlation coefficient (R2) value for the company B kit was 0.9508, and for the company C kit was 0.9352 Conclusion As a result, there was a slight difference in precision at the low concentration sample. The correlation test showed an excellent correlation coefficient. However, it was difficult to secure samples of various concentrations because there were not many tests of testosterone requested at this hospital. So, additional experiments should be carried out by acquiring samples of various concentrations on each laboratory later.