• Title/Summary/Keyword: Laboratory test data

Search Result 1,306, Processing Time 0.032 seconds

Accuracy of provisional crowns made using stereolithography apparatus and subtractive technique

  • Kang, Seen-Young;Park, Jung-Hyun;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.5
    • /
    • pp.354-360
    • /
    • 2018
  • PURPOSE. To compare and analyze trueness and precision of provisional crowns made using stereolithography apparatus and subtractive technology. MATERIALS AND METHODS. Digital impressions were made using a master model and an intraoral scanner and the crowns were designed with CAD software; in total, 22 crowns were produced. After superimposing CAD design data and scan data using a 3D program, quantitative and qualitative data were obtained for analysis of trueness and precision. Statistical analysis was performed using normality test combined with Levene test for equal variance analysis and independent sample t-test. Type 1 error was set at 0.05. RESULTS. Trueness for the outer and inner surfaces of the SLA crown (SLAC) were $49.6{\pm}9.3{\mu}m$ and $22.5{\pm}5.1{\mu}m$, respectively, and those of the subtractive crown (SUBC) were $31.8{\pm}7.5{\mu}m$ and $14.6{\pm}1.2{\mu}m$, respectively. Precision values for the outer and inner surfaces of the SLAC were $18.7{\pm}6.2{\mu}m$ and $26.9{\pm}8.5{\mu}m$, and those of the SUBC were $25.4{\pm}3.1{\mu}m$ and $13.8{\pm}0.6{\mu}m$, respectively. Trueness values for the outer and inner surfaces of the SLAC and SUBC showed statistically significant differences (P<.001). Precision for the inner surface showed significance (P<.03), whereas that for the outer surface showed no significance (P<.58). CONCLUSION. The study demonstrates that provisional crowns produced by subtractive technology are superior to crowns fabricated by stereolithography in terms of accuracy.

Computational assessment of blockage and wind simulator proximity effects for a new full-scale testing facility

  • Bitsuamlak, Girma T.;Dagnew, Agerneh;Chowdhury, Arindam Gan
    • Wind and Structures
    • /
    • v.13 no.1
    • /
    • pp.21-36
    • /
    • 2010
  • A new full scale testing apparatus generically named the Wall of Wind (WoW) has been built by the researchers at the International Hurricane Research Center (IHRC) at Florida International University (FIU). WoW is capable of testing single story building models subjected up to category 3 hurricane wind speeds. Depending on the relative model and WoW wind field sizes, testing may entail blockage issues. In addition, the proximity of the test building to the wind simulator may also affect the aerodynamic data. This study focuses on the Computational Fluid Dynamics (CFD) assessment of the effects on the quality of the aerodynamic data of (i) blockage due to model buildings of various sizes and (ii) wind simulator proximity for various distances between the wind simulator and the test building. The test buildings were assumed to have simple parallelepiped shapes. The computer simulations were performed under both finite WoW wind-field conditions and in an extended Atmospheric Boundary Layer (ABL) wind flow. Mean pressure coefficients for the roof and the windward and leeward walls served as measures of the blockage and wind simulator proximity effects. The study uses the commercial software FLUENT with Reynolds Averaged Navier Stokes equations and a Renormalization Group (RNG) k-${\varepsilon}$ turbulence model. The results indicated that for larger size test specimens (i.e. for cases where the height of test specimen is larger than one third of the wind field height) blockage correction may become necessary. The test specimen should also be placed at a distance greater than twice the height of the test specimen from the fans to reduce proximity effect.

A Study on the Space Area Guideline of Clinical Laboratory in Korea - Focused on Laboratory Case Studies (국내 종합병원 진단검사의학과의 면적산정 방법에 대한 연구 - 검사실 사례조사를 중심으로)

  • Kim, Youngaee;Song, Sanghoon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.26 no.2
    • /
    • pp.39-47
    • /
    • 2020
  • Purpose: Clinical laboratory of hospital has been demanded to extension or relocation regarding with the test number increase and analyzer development. Space area criteria per test numbers, lab functions, hospital bed and lab staffs are needed for draft space programing. So, the purpose of this study is to provide the space area guideline of clinical laboratory for space calculation in planning and design the spatial environment. Methods: Literature review has been used in checking the standards and guidelines. And questionnaire surveys to laboratory supervisors in hospitals have been conducted for the data collection. 60 answers have been analysed statistically by MS Excel program. Results: The result of this study can be summarized into three way calculations. The first one shows that the basic standard workspace and distance is applied in lab design. The second one shows that average space area criteria resulted from case studies is applied by 19㎡ per one staff, 0.9~1.0㎡ per one bed, and lastly linear length calculation of workbenches and analyzers on the bench top and floor mount, is multiplying it by the sum of the counter depth plus aisle width. Implications: In updating the space area calculation guidelines, it is necessary to cooperate with medical staffs and designers.

Cytogenetic and Clinical Analysis for Antenatal Diagnosis in Amniotic Fluid (산전 태아 진단을 위한 양수의 세포유전학적 분석)

  • Oh, Hyun-Sook;Kim, Mi-Kyeong;Kim, Seong-Mi
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.39 no.3
    • /
    • pp.151-155
    • /
    • 2007
  • Diagnosis and prevention of cytogenetics diseases are one of the most important parts in prenatal care. For that reason, it is necessary to examine birth defects. However, there is no reliable statistical data about birth defects in our country. In this study, the ratio of birth defects were determined by cytogenetics analysis and amniocentesis, in addition, the usefulness of amniocentesis was analyzed. The screening test and the triple marker test were conducted for 3,325 pregnant women of between 15 and 22 weeks gestation. Amniocentesis was performed for 170 pregnant women who were positive in the two tests, 184 women of advanced maternal age and 48 women with family history of chromosome aberrations. Among 419 women, 8 pregnant women who were positive in the triple marker test, 1 woman who close to the cut-off value in the triple marker test, 2 women with advanced maternal age and 1 woman who has history of chromosome aberration pregnance that was positive in cytogenetics analysis. The overall incidence of chromosomal aberration was 12 cases including 7 cases of Down's syndrome, 1 case of Patau syndrome, 1 case of Klinefelter syndrome, 1 case of Edward syndrome, 1 case of Robertsonian translocation and 1 case of XYY syndrome. These results show that amniocentesis for pregnant women who need chromosome test in prenatal cytogenetics analysis is very useful.

  • PDF

Estimation of Equivalent Diameter for Cross Shaped Vertical Drain Installed in Weak Clay Soils (연약점성토 지반에 타설된 십자형배수재의 등가직경 산정)

  • 장연수;김영우;김수삼
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.1
    • /
    • pp.43-50
    • /
    • 2000
  • In this paper, the consolidation efficiency and the equivalent diameter of the cross shaped drain are examined by using the laboratory test and the numerical model, and the results are compared with those of the band shaped drain. The equivalent diameter of the tested drains is back-calculated from the laboratory experiment and compared with those calculated from the formula suggested in the literature. The efficiency of the cross shaped drain is evaluated by using the 3-D flow program which was validated by the settlement-time test fill data. The results of laboratory test show that the equivalent diameter of the band shaped drain was close to the Rixner's formula and that of the cross shaped drain was fit to the following formula: $d_w\;=\; \\tarc{3}{4}.(b+t)$The results of the numerical analysis show that the cross shaped drain can reduce the consolidation time by 9-10% from that for the band shaped drain. The equivalent diameter obtained from the numerical flow model by using the field data is 3.5 times smaller than that obtained from the laboratory consolidation test.

  • PDF

Introduction to Simulation Activity for CMDPS Evaluation Using Radiative Transfer Model

  • Shin, In-Chul;Chung, Chu-Yong;Ahn, Myoung-Hwan;Ou, Mi-Lim
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.282-285
    • /
    • 2007
  • Satellite observed brightness temperature simulation using a radiative transfer model (here after, RTM) is useful for various fields, for example sensor design and channel selection by using theoretically calculated radiance data, development of satellite data processing algorithm and algorithm parameter determination before launch. This study is focused on elaborating the simulation procedure, and analyzing of difference between observed and modelled clear sky brightness temperatures. For the CMDPS (COMS Meteorological Data Processing System) development, the simulated clear sky brightness temperatures are used to determine whether the corresponding pixels are cloud-contaminated in cloud mask algorithm as a reference data. Also it provides important information for calibrating satellite observed radiances. Meanwhile, simulated brightness temperatures of COMS channels plan to be used for assessing the CMDPS performance test. For these applications, the RTM requires fast calculation and high accuracy. The simulated clear sky brightness temperatures are compared with those of MTSAT-1R observation to assess the model performance and the quality of the observation. The results show that there is good agreement in the ocean mostly, while in the land disagreement is partially found due to surface characteristics such as land surface temperature, surface vegetation, terrain effect, and so on.

  • PDF

Assessment of Sensitivity of Photo-Chromosomal Assay in the Prediction of Photo-carcinogenicity (광염색체이상시험의 광발암성 예측능력에 대한 평가)

  • Hong Mi-Young;Kim Ji-Young;Lee Young Mi;Lee Michael
    • Toxicological Research
    • /
    • v.21 no.2
    • /
    • pp.99-105
    • /
    • 2005
  • Photo-mutagenic compounds have been known to alter skin cancer rates by acting as initiators or by affecting subsequent steps in carcinogenesis. The objectives of this study are to investigate the utility of photo-chromosomal aberration (photo-CA) assay for detecting photo-clastogens, and to evaluate its ability to predict rodent photocarcinogenicity. Photo-CA assay was performed with five test substances that demonstrated positive results in photo-carcinogenicity tests: 8-Methoxypsoralen (photoactive substance that forms DNA adducts in the presence of ultraviolet A irradiation), chlorpromazine (an aliphatic phenothiazine an alpha-adrenergic blocking agent), lomefloxacin (an antibiotic in a class of drugs called fluoroquinolones), anthracene (a tricyclic aromatic hydrocarbon a basic substance for production of anthraquinone, dyes, pigments, insecticides, wood preservatives and coating materials) and Retinoic acid (a retinoid compound closely related to vitamin A). For the best discrimination between the test substance-mediated genotoxicity and the undesirable genotoxicity caused by direct DNA absorption, a UV dose-response of the cells in the absence of the test substances was firstly analyzed. All 5 test substances showed a positive outcome in photo-CA assay, indicating that the photo-CA test is very sensitive to the photo-genotoxic effect of UV irradiation. With this limited data-set, an investigation into the predictive value of this photo-CA test for determining the photo-carcinogenicity showed that photo-CA assay has the high ability of a test to predict carcinogenicity. Therefore, the photo-CA test using mammalian cells seems to be a sensitive method to evaluate the photo-carcinogenic potential of new compounds.

Field and laboratory assessment of ground subsidence induced by underground cavity under the sewer pipe

  • Kong, Suk-Min;Kim, Dong-Min;Lee, Dae-Young;Jung, Hyuk-Sang;Lee, Yong-Joo
    • Geomechanics and Engineering
    • /
    • v.16 no.3
    • /
    • pp.285-293
    • /
    • 2018
  • In densely populated urban areas with a large amount of infrastructure, ground subsidence events can result in massive casualties and economic losses. In South Korea, the incidence of ground subsidence in urban areas has increased in recent years and the number of underground cavities suspected of causing such events has significantly increased. Therefore, it is essential to develop techniques to prevent the occurrence of underground and ground subsidence. In this study, a field test, laboratory test, and numerical analysis were conducted to determine the optimal compaction degree of the upper support layer of any underground cavity below the level of sewer pipes in order to prevent such cavities from collapsing and leading to ground subsidence accidents. During the field test, an underground cavity was simulated using ice, and the generation of the cavity was confirmed using ground penetrating radar. The ground investigation was performed using a cone penetration test, and the compaction of the ground where ground subsidence occurred was evaluated with a laboratory test. The behaviour of the ground under various conditions was predicted using a numerical analysis based on the data obtained from the field test and previous studies. Based on these results, the optimal compaction degree of the ground required to prevent the underground cavity from causing ground subsidence was predicted and presented.

Analysis of MODIS cloud masking algorithm using direct broadcast data over Korea and its improvement

  • Lee, H.J.;Chung, C.Y.;Ahn, M.H.;Nam, J.C.
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.461-463
    • /
    • 2003
  • The information on the cloud presence within a instantaneous field of view is the first step toward the derivation of many other geophysical parameters. Here, we first applied the current MODIS cloud detection algorithm developed by University of Wisconsin and compared the results to a visual interpretation of composite data, especially during the daytime. Most of cases, the detection algorithm performs very well, except a few cases with over-detection. One of the reasons for the false detection is due to the time independent use of land information which affects the threshold values of visible channel test. In the presentation, we show detailed analysis of the current cloud detection algorithm and suggest possible way to overcome the current shortfall.

  • PDF

Automated data interpretation for practical bridge identification

  • Zhang, J.;Moon, F.L.;Sato, T.
    • Structural Engineering and Mechanics
    • /
    • v.46 no.3
    • /
    • pp.433-445
    • /
    • 2013
  • Vibration-based structural identification has become an important tool for structural health monitoring and safety evaluation. However, various kinds of uncertainties (e.g., observation noise) involved in the field test data obstruct automation system identification for accurate and fast structural safety evaluation. A practical way including a data preprocessing procedure and a vector backward auto-regressive (VBAR) method has been investigated for practical bridge identification. The data preprocessing procedure serves to improve the data quality, which consists of multi-level uncertainty mitigation techniques. The VBAR method provides a determinative way to automatically distinguish structural modes from extraneous modes arising from uncertainty. Ambient test data of a cantilever beam is investigated to demonstrate how the proposed method automatically interprets vibration data for structural modal estimation. Especially, structural identification of a truss bridge using field test data is also performed to study the effectiveness of the proposed method for real bridge identification.