• 제목/요약/키워드: Laboratory test

검색결과 6,897건 처리시간 0.043초

A Study on the Hot Spot Temperature in 154kV Power Transformers

  • Kweon, Dong-Jin;Koo, Kyo-Sun;Woo, Jung-Wook;Kwak, Joo-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권3호
    • /
    • pp.312-319
    • /
    • 2012
  • The life of a power transformer is dependent on the life of the cellulose paper, which influenced by the hot spot temperature. Thus, the determination of the cellulose paper's life requires identifying the hot spot temperature of the transformer. Currently, however, the power transformer uses a heat run test is used in the factory test to measure top liquid temperature rise and average winding temperature rise, which is specified in its specification. The hot spot temperature is calculated by the winding resistance detected during the heat run test. This paper measures the hot spot temperature in the single-phase, 154kV, 15/20MVA power transformer by the optical fiber sensors and compares the value with the hot spot temperature calculated by the conventional heat run test in the factory test. To measure the hot spot temperature, ten optical fiber sensors were installed on both the high and low voltage winding; and the temperature distribution during the heat run test, three thermocouples were installed. The hot spot temperature shown in the heat run test was $92.6^{\circ}C$ on the low voltage winding. However, the hot spot temperature as measured by the optical fiber sensor appeared between turn 2 and turn 3 on the upper side of the low voltage winding, recording $105.9^{\circ}C$. The hot spot temperature of the low voltage winding as measured by the optical fiber sensor was $13.3^{\circ}C$ higher than the hot spot temperature calculated by the heat run test. Therefore, the hot spot factor (H) in IEC 60076-2 appeared to be 2.0.

무인항공기 위치정확도 시험평가 기법 연구 (Feasibility Study on the Methodology of Test and Evaluation for UAV Positioning)

  • 주요한;문경환;강봉석;정재원;손한기;조정현
    • 한국항행학회논문지
    • /
    • 제22권6호
    • /
    • pp.530-536
    • /
    • 2018
  • 최근 무인항공기 드론의 활용범위와 수요가 지속적으로 증가함에 따라 무인항공기와 유인항공기 간 공역을 통합하여 운용하는 연구가 전 세계적으로 활발하게 진행되고 있다. 공역 통합을 위해서는 유인항공기에 준한 기술기준 및 인증 제도 수립이 필수적이며, 이에 따른 시험평가 방안이 제시되어야 한다. 본 논문에서는 향후 무인항공기 항법 시스템에 대한 기술기준이 수립되었을 경우, 기술기준 적합성 검증을 위한 시험방법을 제시하였다. 연구를 위해 무인항공기 임무 프로파일 및 운용환경 분석, 시험항목 도출, 시험방법 수립, 시뮬레이션 및 무인항공기를 통한 실증을 수행하였다. 시험방법으로 정적시험, 트랙이동시험, 경로비행시험이 도출되었으며, 각 시험수행 결과 시험대상 무인항공기의 항법시스템 오차는 전체 비행단계에서 95% 신뢰수준에서 약 1.4m의 위치정확도를 보임을 확인하였다.

ESR 자동분석기를 이용한 내부정도관리방법 (The Internal Quality Control for TEST 1, the Automatic Analyzer of Erythrocyte Sedimentation Rate)

  • 조영국;심현설;송운흥;박규은
    • 대한임상검사과학회지
    • /
    • 제36권2호
    • /
    • pp.239-244
    • /
    • 2004
  • Recently automatic equipment has been well popularized for the erythrocyte sedimentation rate, a widely used test, but no standard quality control has been established yet. Thus, we are going to report a case that established and applied a quality control method using the TEST 1 automatic analyzer. For internal quality control, we adopted the repeatability test through comparison with daily mean check, with a manual method using patients' specimens and with the results of a test on the previous day. In order to set the tolerance standard for each quality control method, we compared the results of 50 specimens that showed a wide range of ESR results and examined correlation and differences according to result. After setting the tolerance standard, we applied the standard at tertiary university hospitals for 120 days and investigated positive rates and re-examination rates. If the tolerance standard was exceeded, the cause was also identified. We selected a specimen of below 25 mm/hr (T1), one between 26-50 mm/hr (T2) and one of over 51 mm/hr (T3) at random. The correlation between the manual method and the automatic method was quite high (r=0.98), and it is found appropriate to set based on differences in result values below 25 mm/hr, the upper limit of the reference value, and based on differences in the percentage of result values above 25 mm/hr. Accordingly, we set the criteria for rejection above 10 mm/hr and above 20%. When the criteria were applied in the laboratory, 1.7% of specimens in the range of T1, 8.3% of those in the range of T2 and 7.5% of those in the range of T3 were rejected. Because all the rejected ones fell within the tolerance limit in re-examination calibration verification was not carried out. With the wide popularization of erythrocyte sedimentation rate analyzers that can carry out a lot of tests quickly using automatic methods, it is necessary to improve the reliability of test results by establishing internal quality control policies. We expect that an agreed standard quality control method may be established based on the method proposed in this study.

  • PDF

2009년 유통 농산물 중 잔류농약 실태조사 (Research on Pesticides Residue in Commercial Agricultural Products in 2009)

  • 이주영;최원조;이희정;신용운;도정아;김우성;최동미;채갑용;강찬순
    • 한국식품위생안전성학회지
    • /
    • 제25권2호
    • /
    • pp.192-202
    • /
    • 2010
  • 국내 유통 농산물 16품목 (쌀, 조, 메밀, 강낭콩, 땅콩, 참깨, 오렌지, 자몽, 키위, 시금치, 들깻잎, 부추, 마늘쫑, 마늘, 생강, 표고버섯)을 대상으로 다성분 분석농약172종을 분석하여 농약 잔류실태를 조사하였다. 조사대상 농산물 510건 중 대부분의 농산물인 459건 (90.0%)의 농산물은 농약이 검출되지 않았으며, 51건 (10.0%)의 농산물에서 농약이 검출되었으나 대부분 잔류허용기준 미만으로 검출되엇다. 들깻잎, 부추 등 엽채류의 검출빈도가 높은 편이었으나 대부분 잔류허용기준 미만으로 검출되었고, 키위에서 phenthoate이 잔류허용기준 이상으로 검출되었다. 또한 검출된 농약 24종에 대한 위해평가를 수행한 결과 위해도는 매우 낮은 것으로 조사되어 유통 농산물에 대한 농약의 검출량은 대부분 잔류허용기준 미만으로 비교적 안전한 수준으로 관리가 이루어지고 있는 것으로 판단되었다. 앞으로 지속적이고 체계적인 유통 농산물 조사 연구사업으로 농약 잔류허용기준 준수 여부의 적합성을 판단하기 위한 기초 자료로 축적될 것으로 사료된다.

New Public Key Encryption with Equality Test Based on non-Abelian Factorization Problems

  • Zhu, Huijun;Wang, Licheng;Qiu, Shuming;Niu, Xinxin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제12권2호
    • /
    • pp.764-785
    • /
    • 2018
  • In this paper, we present a new public key encryption scheme with equality test (PKEwET). Compared to other PKEwET schemes, we find that its security can be improved since the proposed scheme is based on non-Abelian factorization problems. To our knowledge, it is the first scheme regarding equality test that can resist quantum algorithm attacks. We show that our scheme is one-way against chosen-ciphertext attacks in the case that the computational Diffie-Hellman problem is hard for a Type-I adversary. It is indistinguishable against chosen-ciphertext attacks in the case that the Decisional Diffie-Hellman problem is hard in the random oracle model for a Type-II adversary. To conclude the paper, we demonstrate that our scheme is more efficient.

362 kV GIB 내에서 건조공기의 절연파괴 특성 (Breakdown Characteristics of Dry Air under 362 kV GIB)

  • 한기선;주형준;윤진열;유홍근
    • 한국전기전자재료학회논문지
    • /
    • 제23권10호
    • /
    • pp.804-808
    • /
    • 2010
  • In this paper, we studied the dielectric breakdown voltage characteristics by the AC withstand voltage test on using green insulation dry air instead of $SF_6$ insulation gas used in the GIB (gas insulated bus) of 362 kV GIS (gas insulated switchgear). The AC withstand voltage test applied to the standard KEPCO's 362 kV GIB with dry air insulation, and the equivalence of dielectric breakdown voltage for dry air and $SF_6$ gas were examined, and the empirical formulas of dielectric breakdown voltage for dry air were calculated, and the criterion of AC withstand voltage test for dry air insulation was derived. Using the criterion, dry air can be used instead of $SF_6$ gas for 362 kV GIB in the factory acceptance test was confirmed.

Screening of New Bioactive Materials from Microbial Extracts of Soil Microorganism (I) Antimicrobial Activity from 200 Sampled Using Microdilution Assay

  • Jung, Sang-Oun;Kim, Joon;Chang, Il-Moo;Ryu, Jae-Chun
    • Archives of Pharmacal Research
    • /
    • 제21권3호
    • /
    • pp.278-285
    • /
    • 1998
  • The microdilution assay recommended by NCCLS (National Committee for Clinical Laboratory Standards) is one of the standardized methods of antibiotic susceptibility test. This method has been widely used clinically to obtain MIC values of antibiotics on pathogenic microorganisms. It is more convenient, rapid and simple to test many samples than other test methods such as agar diffusion assay and broth macrodilution assay. The screening of antimicrobial agents from microbial extracts is too laborious in its process. Therefore, a number of screening methods having more simple procedure have been developed. In our laboratory, we applied microdilution assay for screening the antimicrobial agents. This assay showed dose-response results and was more sensitive than disc diffusion assay in our system. We tested 200 samples of microbial extracts originated from 100 microbial strains and selected several samples as potential candidates. In this report, we show that the microdilution assay is more convenient method in screeing of antibiotic susceptibility than those previously reported.

  • PDF

Accelerated and Outdoor Exposure Tests of Aluminum Coated Steel Sheets

  • Kim, Jongmin;Lee, Jaemin;Lim, Sangkyu;Jung, Choonho
    • Corrosion Science and Technology
    • /
    • 제10권6호
    • /
    • pp.199-204
    • /
    • 2011
  • Hot dip metallic coated steels like as galvanized (GI), zinc-aluminium (GL) and aluminium coated steels are mostly used where corrosion resistance is needed. There are two kinds (type 1 and type 2) of aluminium coated steel being commercially used among them. Type 1 aluminium coated steel is coated with an Al-5~11 wt%Si alloy and Type 2 aluminium coated steel consists of commercially pure aluminium. Type 1 Al coated steel is generally used in automotive components and electrical appliances while type 2 aluminium coated steel is mainly used in construction applications such as building cladding panels, air conditioning and ventilation system. In this study, Type 1 aluminium coated steels have tested by accelerated conditions (salt spray or corrosive gas) and outdoor exposure condition in order to understand their corrosion behaviour. Due to the distinct corrosion mechanism of Al which exposes to the severe chloric condition, Salt Spray Test cannot predict the ordinary atmospheric corrosion of Al based coated materials. In addition, the test results and their corrosion feature of Al coated steel sheets will be discussed comparing with other metallic coated steel sheets of GI and GL.

Design and analysis of a control system for a multi-magnet levitation system

  • Kweon, Soon-Man;Kim, Seog-Joo;Kim, Jong-Moon;Kim, Kook-Hun;Kim, Yong-Joo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.1332-1336
    • /
    • 1990
  • This paper deals with some analytical and experimental aspects to control a multi-magnet suspended vehicle. Because the response of a multi-magnet vehicle shows mutually coupled interaction, an analytical description of the vehicle dynamics is necessary. For numerical computations, a linearized modelling of vehicle dynamics is dicussed and computer simulation is carried out. And for the experiment, a test vehicle suspended by four magnets has been made and investigated by local control of each magnet. Two algorithms by PID and state feedback control law are used and compared with each other. Some kinds of disturbance characteristics and coupling effects of the width change of the test vehicle are experimented.

  • PDF

Design of a Moving-magnet Electromagnetic Actuator for Fast Steering Mirror through Finite Element Simulation Method

  • Long, Yongjun;Mo, Jinqiu;Wei, Xiaohui;Wang, Chunlei;Wang, Shigang
    • Journal of Magnetics
    • /
    • 제19권3호
    • /
    • pp.300-308
    • /
    • 2014
  • This paper develops a moving-magnet electromagnetic actuator for fast steering mirror (FSM). The actuator achieves a reasonable compromise between voice coil actuator and piezoelectric actuator. The stroke of the actuator is between the strokes of a piezoelectric actuator and a voice coil actuator, and its force output is a linear function of air gap and excitation current within our FSM travel range. Additionally, the actuator is more reliable than voice coil actuator as the electrical connection in the actuator is static. Analytically modeling the actuator is difficult and time-consuming. Alternatively, numerous finite element simulations are carried out for the actuator analysis and design. According to the design results, a real prototype of the actuator is fabricated. An experimental test system is then built. Using the test system, the force output of the fabricated actuator is evaluated. The test results validate the actuator analysis and design.