• 제목/요약/키워드: Laboratory load test

검색결과 578건 처리시간 0.024초

The seismic performance of steel pipe-aeolian sand recycled concrete columns

  • Yaohong Wang;Kangjie Chen;Zhiqiang Li;Wei Dong;Bin Wu
    • Earthquakes and Structures
    • /
    • 제26권1호
    • /
    • pp.77-86
    • /
    • 2024
  • To investigate the seismic performance of steel pipe-aeolian sand recycled concrete columns, this study designed and produced five specimens. Low-cycle repeated load tests were conducted while maintaining a constant axial compression ratio. The experiment aimed to examine the impact of different aeolian sand replacement rates on the seismic performance of these columns. The test results revealed that the mechanical failure modes of the steel pipe-recycled concrete column and the steel pipe-aeolian sand recycled concrete column were similar. Plastic hinges formed and developed at the column foot, and severe local buckling occurred at the bottom of the steel pipe. Interestingly, the bulging height of the damaged steel pipe was reduced for the specimen mixed with an appropriate amount of wind-deposited sand under the same lateral displacement. The hysteresis curves of all five specimens tested were relatively full, with no significant pinching phenomenon observed. Moreover, compared to steel tube-recycled concrete columns, the steel tube-aeolian sand recycled concrete columns exhibited improved seismic energy dissipation capacity and ductility. However, it was noted that as the aeolian sand replacement rate increased, the bearing capacity of the specimen increased first and then decreased. The seismic performance of the specimen was relatively optimal when the aeolian sand replacement rate was 30%. Upon analysis and comparison, the damage analysis model based on stiffness and energy consumption showed good agreement with the test results and proved suitable for evaluating the damage degree of steel pipe-wind-sand recycled concrete structures.

터널 숏크리트 응력계의 성능검증과 신뢰성 시험 연구 (Performance Verification and Reliability Test of Tunnel Shotcrete Stressmeter)

  • 김영배;박영배;이성원;이강일
    • 한국지반공학회논문집
    • /
    • 제40권4호
    • /
    • pp.113-126
    • /
    • 2024
  • NATM 터널에서 숏크리트의 응력측정은 계측기기의 신뢰도를 검증할 방법, 절차, 규정 등에 관한 연구 부족으로 인해 터널현장에서는 성능검증 없이 숏크리트 응력계가 설치 및 관리되고 있다. 본 연구에서는 일체형 및 셀타입 숏크리트 응력계의 외관검사, 구조·기능검사를 통해 불량 원인 및 문제점을 파악하고, 성능검사는 1차 시험으로 센서에 직접 하중을 재하하는 방식으로 하고, 셀타입 숏크리트 응력계는 KOLAS인증을 받은 성능검증장치를 국내 최초로 개발하여 성능검사를 실시하였다. 2차 시험으로 콘크리트 몰드시험을 통하여 일체형 및 셀타입 숏크리트 응력계의 구조적인 문제점을 파악하고 개선방안과 성능검증 절차를 제시하였다. 본 연구는 향후 숏크리트 응력계의 성능검증을 위한 규정 마련과 현장에서 계측기기를 선정하는 데 도움이 될 것으로 판단된다.

절리분포 양상에 따른 디스크커터의 절삭력에 관한 수치해석적 연구 (Numerical Analysis on Cutting Power of Disc Cutter with Joint Distribution Patterns)

  • 이승중;최성웅
    • 터널과지하공간
    • /
    • 제21권3호
    • /
    • pp.151-163
    • /
    • 2011
  • LCM 시험은 디스크커터의 설계와 굴진성능 예측을 위한 가장 신뢰성 있는 시험으로 알려져 왔다. 하지만, 실대형 시료를 대상으로 실제의 커터 하중을 예측할 수 있는 이점이 있음에도 불구하고, 시료의 채취 및 운반이 용이하지 않고 1회 시험에 많은 비용이 소요된다는 단점을 갖고 있다. 또한 절리를 포함한 시료에 대한 시험의 경우, 시험 과정이 용이하지 않을 뿐만 아니라, 시험에서 예측된 모델을 설계에 반영하기 어려운 경우가 많다. 이러한 한계점을 극복하기 위해 수치해석 모델개발에 관한 연구가 활발히 진행되고 있다. 본 논문에서는 입자의 유동해석을 효과적으로 묘사할 수 있는 PFC2D를 이용하여 디스크커터의 절삭운동에 의한 암석시험편의 파쇄형상 및 균열 전파양상을 분석하고자 하였다. 또한 절리를 포함한 암석시험편을 모델링하여 절리의 경사각, 절리의 경사방향 그리고 절삭면에 노출된 절리의 간격의 변화에 따른 디스크커터의 절삭력을 수치해석적으로 분석하였다. 해석결과, 절리의 경사방향이 디스크커터의 진행방향과 반대일 때, 절리의 경사각이 작을수록, 노출된 절리의 간격이 좁을수록 더 큰 절삭력이 요구됨을 알 수 있었다. 이와 같은 수치해석 결과를 토대로, 디스크커터와 절리의 분포 특성과의 상관관계를 LCM 시험 결과와 비교 분석한다면, 보다 정확한 수치모델을 개발할 수 있을 것으로 판단되며 TBM(Tunnel Boring Machine) 굴착성능 예측 및 디스크커터의 적합 설계에 합리적인 판단기준을 제시할 수 있을 것으로 기대된다.

아스팔트 혼합물의 점탄성과 차량의 이동 속도가 포장 거동에 미치는 영향 (Asphalt Concrete Pavement Response to Moving Load and Viscoelastic Property)

  • 조명환;김낙석;서영국
    • 대한토목학회논문집
    • /
    • 제28권4D호
    • /
    • pp.485-492
    • /
    • 2008
  • 본 논문에서는 차량의 주행속도가 아스팔트 포장의 변형률 거동에 미치는 영향을 알아보기 위하여 현장시험을 실시하고 그 결과를 3차원 유한요소해석과 비교, 분석하였다. 한국도로공사 시험도로에서 기층의 두께가 다른 세 단면(A2, A5, A8)을 선정하고, 각 단면별로 세 가지의 주행속도(25, 50, 80km/hr)에 대한 종, 횡방향 변형률을 측정하였다. ABAQUS를 이용한 수치해석에서는 시험차량인 덤프트럭(단축-탠덤축)의 축하중을 단계하중(step loading)으로 모사하였으며, 시험도로 아스팔트 혼합물에 대한 선형 점탄성 물성 계수(E(t))를 적용하여 보다 현실적인 거동해석을 실시하였다. 주어진 시험 조건에서 아스팔트 층 하부에서 측정한 종, 횡방향 변형률의 차이(이방성)는 모든 단면에서 목격되었고, 수치해석결과 차량의 주행속도가 증가함에 따라 임계 지점에서 발생하는 최대 변형률의 크기는 감소하는 것으로 예측되었다. 또한, 최대변형률의 크기도 횡방향 변형률이 종방향 변형률에 비하여 약 27% 정도 작았으며, 차량의 속도가 증가함에 따라 최대 변형률의 감소폭도 횡방향이 약간 큰 것으로 나타났다.

할선탄성계수를 이용한 반복하중 하 지반의 영구변형 해석 (Analysis of Permanent Deformation under Repetitive Load Based on Degraded Secant Modulus)

  • 안재훈;오정호;신호성
    • 한국지반공학회논문집
    • /
    • 제29권2호
    • /
    • pp.15-21
    • /
    • 2013
  • 일반적으로 도로 포장체 영구변형의 해석은, 먼저 포장체를 층이 진 탄성체로 가정하고 회복탄성계수를 통해 포장체의 회복변형률을 계산하고, 이로부터 다시 실내시험을 통해 얻어진 방정식을 이용하여 영구변형률을 산정하게 된다. 회복탄성계수를 통하여 포장체 내의 응력을 산정할 경우, 포장 내 노상토 상부의 응력은 반복하중으로 인한 노상토의 영구변형 증가를 고려하지 않은 회복탄성계수로부터 결정되므로, 영구변형이 지반 및 포장체에 미치는 영향은 응력 산정 시에 고려되지 않는다. 또한, 토목섬유 등으로 보강된 포장체 등의 거동은 해석에 한계가 있다. 본 논문에서는 기존에 회복탄성계수를 사용하여 포장체의 탄성거동을 계산하는 방식과 달리 하중반복회수의 함수인 할선탄성계수를 사용하여 영구변형을 측정할 수 있도록 새로운 모델을 제안하고, 본 모델 적용과 모델계수 산정의 예를 보인다. 제안된 할선탄성계수를 통한 해석은 비포장 도로 상의 교통으로 인한 영구변형의 예측이나 아스팔트 포장 전 노상토나 기층상부에 가해지는 공사차량으로 인한 영구변형의 산정에 적용가능 할 것으로 판단한다.

Lithium Disilicate (IPS e.max CAD) 코어와 전장 도재 사이의 전단결합강도에 관한 연구 (A Study on the Shear Bond Strength of Veneering Ceramics to the Lithium Disilicate (IPS e.max CAD) Core)

  • 김기백;김재홍
    • 치위생과학회지
    • /
    • 제13권3호
    • /
    • pp.290-295
    • /
    • 2013
  • 본 연구는 심미 치과보철물에 사용되는 지르코니아, lithium disilicate 코어와 전장도재 사이의 전단결합강도를 측정하고, 금속도재관을 대조군으로 설정하여 비교하였다. 직사각기둥 모양의 시편을 각각 10개씩 제작하여 코어와 전장도재 사이의 전단결합강도를 측정한 후 파절면의 양상을 실체현미경을 통해 관찰하였다. 제한된 조건하에 시행된 실험을 통하여 심미보철 분야에 널리 적용되고 있는 치과용세라믹 코어의 전단결합강도를 확인하였으며, 측정 후 비교분석된 결과는 다음과 같다. 2종의 치과용 세라믹 코어와 전장도재 간에 전단결합강도는 금속도재관의 전단결합강도와 유의한 차이가 있었다 (p<0.05). 본 실험 결과를 토대로 ZB군은 임상적으로 받아들여지는 전단결합강도 범위 내 분포를 보이지만, LB군은 임상허용 범위에 못 미치는 결과값을 보였다. 금속도재관과 달리 지르코니아, lithium disilicate 전부도재관은 모두 혼합형 파절양상을 보였다. 결론적으로 전단결합강도 실험에 사용된 시편이 임상적인 치과보철물의 형태와는 달리 실험을 위한 시편의 형태로 제작되어 임상적 결과를 반영하지 못했으며 구강 내의 상황과도 다르다는 한계점을 가지고 있다. 추후에는 이를 보완하여 치과보철물과 유사한 형태의 시편을 이용한 전단결합 강도의 측정과 구강 내 조건을 고려한 추가 실험이 필요하다고 생각된다.

Micro/Nanotribology and Its Applications

  • Bhushan, Bharat
    • Tribology and Lubricants
    • /
    • 제11권5호
    • /
    • pp.128-135
    • /
    • 1995
  • Atomic force microscopy/friction force microscopy (AFM/FFM) techniques are increasingly used for tribological studies of engineering surfaces at scales, ranging from atomic and molecular to microscales. These techniques have been used to study surface roughness, adhesion, friction, scratching/wear, indentation, detection of material transfer, and boundary lubrication and for nanofabrication/nanomachining purposes. Micro/nanotribological studies of single-crystal silicon, natural diamond, magnetic media (magnetic tapes and disks) and magnetic heads have been conducted. Commonly measured roughness parameters are found to be scale dependent, requiring the need of scale-independent fractal parameters to characterize surface roughness. Measurements of atomic-scale friction of a freshly-cleaved highly-oriented pyrolytic graphite exhibited the same periodicity as that of corresponding topography. However, the peaks in friction and those in corresponding topography were displaced relative to each other. Variations in atomic-scale friction and the observed displacement has been explained by the variations in interatomic forces in the normal and lateral directions. Local variation in microscale friction is found to correspond to the local slope suggesting that a ratchet mechanism is responsible for this variation. Directionality in the friction is observed on both micro- and macro scales which results from the surface preparation and anisotropy in surface roughness. Microscale friction is generally found to be smaller than the macrofriction as there is less ploughing contribution in microscale measurements. Microscale friction is load dependent and friction values increase with an increase in the normal load approaching to the macrofriction at contact stresses higher than the hardness of the softer material. Wear rate for single-crystal silicon is approximately constant for various loads and test durations. However, for magnetic disks with a multilayered thin-film structure, the wear of the diamond like carbon overcoat is catastrophic. Breakdown of thin films can be detected with AFM. Evolution of the wear has also been studied using AFM. Wear is found to be initiated at nono scratches. AFM has been modified to obtain load-displacement curves and for nanoindentation hardness measurements with depth of indentation as low as 1 mm. Scratching and indentation on nanoscales are the powerful ways to screen for adhesion and resistance to deformation of ultrathin fdms. Detection of material transfer on a nanoscale is possible with AFM. Boundary lubrication studies and measurement of lubricant-film thichness with a lateral resolution on a nanoscale have been conducted using AFM. Self-assembled monolyers and chemically-bonded lubricant films with a mobile fraction are superior in wear resistance. Finally, AFM has also shown to be useful for nanofabrication/nanomachining. Friction and wear on micro-and nanoscales have been found to be generally smaller compared to that at macroscales. Therefore, micro/nanotribological studies may help def'me the regimes for ultra-low friction and near zero wear.

가정용 전력 모니터링을 위한 전력신호 분석 알고리즘 개발 (Algorithm of Analysing Electric Power Signal for Home Electric Power Monitoring in Non-Intrusive Way)

  • 박성욱;왕보현
    • 한국지능시스템학회논문지
    • /
    • 제21권6호
    • /
    • pp.679-685
    • /
    • 2011
  • 본 연구에서는 가정 내 모든 기기가 연결된 하나의 전력선을 모니터링 하여 그 전력선에 연결된 기기 각각의 젼력 소비 상황을 모니터링 하는 NILM(Non-Intrusive Load Monitoring) 시스템 구축에 필요한 신호 분석 알고리즘에 대한 연구를 수행하였다. 본 연구에서 제안한 신호 분석 알고리즘은 전력선에서 관찰된 여러 기기의 전력 소비 패턴이 혼합된 혼합 전력 패턴을 복수개의 시간 구간으로 분리하고, 연속된 시간 구간 사이의 신호 차이를 구한 후, 이 차이 신호를 분석하여 어떤 장치가 현재 시간 구간에서 동작 중인지를 알아낸다. 이 때 시간 구간을 충분히 작게 하고, 신호 분석에 사용되는 특징들이 독립적이고 additivity 특징을 가지도록 선정한다면, 이 차이 신호에는 한 장치의 특징만이 남아 있으므로, 동시에 동작할 수 있는 장치 조합의 수 $2^N$개가 아닌 장치 N 개에 해당하는 특징만을 이용하여 혼합 신호를 분석할 수 있다. 이를 통하여 장치 개수가 증가하더라도 연산량 역시 산술적으로 증가하는 합리적인 확장성을 확보할 수 있다. 실제 가정에서 각 장치의 데이터 패턴을 채집한 후 이를 인위적으로 조합하여 만든 실험 데이터를 활용하여 제안한 방법을 검증하였다. 검증 결과 4개의 장치가 동시에 동작하고 그 장치의 특징들이 제안한 알고리즘에서 제시한 기준을 만족하는 경우, 비록 제한된 실험이었지만 완벽한 분류 성공률을 보였다. 제안된 알고리즘을 실제 사용하기 위해서는 장치의 수를 증가하고, 시간 구간을 조정하며, 신호 혼합 패턴을 다양하게 한 실증적인 연구가 더 필요하다. 하지만 이 경우 본 연구에서 제안한 기준을 만족하는 특징을 선택한다면, 그렇지 않은 경우에 비하여, 일정 정도 성능이 보장되는 NILM 시스템을 구축할 수 있을 것으로 기대된다.

다축 평면 연속형 SCW 흙막이 벽체의 개선 효과 (Effects of Functional Improvement of Multiaxis Flat Continuous Soil Cement Earth Retaining Wall)

  • 정중섭;유찬호;남호성;최인규;백승철
    • 한국지반공학회논문집
    • /
    • 제39권11호
    • /
    • pp.7-22
    • /
    • 2023
  • 최근 지하안전에 관한 특별법이 시행(2022년 1월)되었으며, 지하안전영향평가를 통해 계획단계부터 지하안전에 관한 사전검토가 실시되고 있다. 지하굴착을 위해서는 가설 흙막이의 구조 안전성을 확보하는 것이 중요하므로 지하안전 검토는 더욱 강화되고 있다. 본 연구에서는 토사지반에서 Soil-Cement 흙막이의 벽체 두께를 확대하고 H-pile의 선택과 설치간격을 자유롭게 할 수 있는 MFS(Multi-axis Flat Continuous Soil Cement Earth Retaining Wall) 흙막이 벽체 공법의 거동 특성을 분석하였다. 실내모형실험을 통해 MFS 공법의 H-pile 설치간격에 따른 벽체에 작용하는 하중-변위 거동을 확인하였으며, MFS 흙막이 벽체의 두께별 H-pile 설치간격 및 크기 변화에 따른 하중-변위를 3차원 수치해석으로 분석하여 벽체에 작용하는 아칭효과 높이를 산정하였다. MFS 공법에서 산정한 최대 아칭높이를 기존의 부재력 검토 방법에 적용하여 벽체에 작용하는 축력, 전단력을 정량적으로 분석하는 설계방법을 제시하였다. 그 결과 MFS 흙막이 벽체에 적용되는 H-pile 설치 간격 및 크기에 따른 축력 및 전단력이 24.6~62.9%가 저감하는 것을 확인하였다.

실링 테이프 적용에 따른 시공조인트 균열 저항성 평가 (Evaluation of Crack Resistance of Cold Joint as Usage of Sealing Tape)

  • 이재준;이선행;김두병;이진욱
    • 한국도로학회논문집
    • /
    • 제20권3호
    • /
    • pp.1-9
    • /
    • 2018
  • PURPOSES : In order to evaluate a crack resistance at cold joint, sealing tape was adopted to apply at cold joint instead of typical tack coat material(RSC-4). The sealing tape was made by hot sealing material. The crack resistance as function of environmental and traffic loading was measured with visual observation. METHODS : In this study, the crack resistance was evaluated as function of environmental and traffic loading. The freeze-thaw method was adopted for environmental loading of asphalt pavement. condition. The damage of cold joint under freeze-thaw action is initiated by ice expansion load and accelerated by the interfacial damage between new and old asphalt pavement. The traffic loading was applied with wheel tracking machine on the cold joint area of the asphalt pavement for 3 hours at $25^{\circ}C$. The evaluation of crack resistance was measured with visual observation. The freeze-thaw results shows that the sealing tape was significantly increased the crack resistance based on. RESULTS : To estimate the crack resistance at cold joint area due to the environmental loading, the Freeze-thaw test was conducted by exposing the product to freezing temperature(approximately $-18^{\circ}C$) for 24 hours, and then allowing it to thaw at $60^{\circ}C$ for 24 hours. The tack coat material(RSC-4) was debonded after 21 cycles of the Freeze-thaw test. The first crack was observed after 14 freeze-thaw cycle with RSC-4 material. But, the sealing tape was not debonded after 24 cycle test. Also, the sealing tape shows the better performance of the crack resistance under the traffic loading with wheel track test. The crack was generated the under traffic loading with RSC-4(tack coating), however, the crack was not shown with sealing tape. It indicates that the sealing tape has a strong resistance of tensile stress due to traffic loading. CONCLUSIONS :Based on limited laboratory test result, a performance of crack resistance using the sealing tape is better than that of general tack coat material(RSC-4). It means that the sealing tape is possible to extend a pavement service life because the crack, one of the main pavement distresses, will be delayed.