Optimal Method of Radon Analysis in Groundwater using Ultra Low-Level Liquid Scintillation Counter (극 저준위 액체섬광계수기를 이용한 지하수 중 라돈($^{222}Rn$) 측정법 연구)

  • Kim Yong-Je;Cho Soo-Young;Yoon Yoon-Yeol;Lee Kil-Yong
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.5
    • /
    • pp.59-66
    • /
    • 2006
  • Optimal method of radon analysis in groundwater was studied using ultra low-level liquid scintillation counter (ULLLSC) which is well known as an analytical instrument for analyzing the alpha and beta radionuclides in environmental materials. Optimization of pulse shape analyzer (PSA) in operating the LSC was performed with $^{241}Am\;and\;^{90}Sr/^{90}Y$ as well as $^{226}Ra$ Also, the chemical quenching of scintillation generation and the color quenching of the generated photon to photomultiplier tubes (PMT) were determined their effects not only to decrease the analytical efficiency but also to change the optimal PSA level and background due to high ion contents of groundwaters. The optimal PSA level was shown in the range of 90 to 110 with less than 5% error. The effects of high ion contents in groundwater for the analytical efficiency show within 10% error from the different ion contents. The chloroform as a quenching agent was used to determine the analytical efficiency with the different amount, showing that the efficiency decreases 20% using the 2% of chloroform.

Simultaneous analysis method of 89Sr and 90Sr in liquid sample using automated separation system (자동핵종분리장치를 이용한 액체시료 중 89Sr, 90Sr 동시분석법 연구)

  • Kim, Heewon;Lee, Yong-Jin;Kim, Sun-Ha;Lee, Jin-Hong;Lim, Jong-Myoung;Kim, Hyuncheol
    • Analytical Science and Technology
    • /
    • v.33 no.6
    • /
    • pp.274-284
    • /
    • 2020
  • This study described the analytical method for simultaneous determination of 89Sr and 90Sr in liquid sample using automated separation system. Radiostrontium in 0.5 kg of liquid sample was concentrated as SrCO3 to reduce the volume of sample, and purified from the sample using Sr-resin 2 mL (BV, Bed volume). The behavior of Sr and interferences such as Ba, Ca and Y were estimated with various flow rate ranging from 1 to 4 mL min-1. The detailed procedure for the purification of Sr on Sr-resin was presented. The purified radiostronitum was measured in Cerenkov mode and then measured in Scintillation mode by mixing scintillation cocktail. The measured value in both modes were used to calculate the activity of 89Sr and 90Sr. The performance tests were carried out the lab-control-sample having various activity ratio of between 89Sr and 90Sr. The recovery of Sr was ranged from 68 to 94 %. The relative bias of 89Sr activity was ranged from -5 to 20 %, and it was ranged from -10 to 10 % for 90Sr.

Legal Regime of Space Debris (우주법의 관점으로부터 본 우주파편)

  • Tatsuzawa, Kunihiko
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.16
    • /
    • pp.224-235
    • /
    • 2002
  • The problem of space debris has been dealt with at the STSC of the COPUOS. The technical discussion at the said Committee was finished by adopting the Technical Report in 1999. Its legal discussion will be followed very soon at the LSC of the COPUOS. In this paper, I try to outline certain legal points concerning the space debris.

  • PDF

A Comprehensive Harmonic Rejection for DFIG Feeding Non-Linear Loads in Stand-Alone Applications

  • Nguyen, Ngoc-Tung;Lee, Hong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.258-259
    • /
    • 2012
  • This paper proposes a new control strategy to eliminate the harmonic components of stator current for stand-alone DFIG system feeding non-linear loads. In this method, the LSC operates as an active filter which is controlled by employing a proportional-integral and a resonant controller. And also, the stator current is used as the feedback signal for the compensator instead of the load current, so that the additional current sensor at the load side can be removed. The experiment is verified to validate the effectiveness of the proposed compensating method.

  • PDF

Control strategy for the substructuring testing systems to simulate soil-structure interaction

  • Guo, Jun;Tang, Zhenyun;Chen, Shicai;Li, Zhenbao
    • Smart Structures and Systems
    • /
    • v.18 no.6
    • /
    • pp.1169-1188
    • /
    • 2016
  • Real-time substructuring techniques are currently an advanced experimental method for testing large size specimens in the laboratory. In dynamic substructuring, the whole tested system is split into two linked parts, the part of particular interest or nonlinearity, which is tested physically, and the remanding part which is tested numerically. To achieve near-perfect synchronization of the interface response between the physical specimen and the numerical model, a good controller is needed to compensate for transfer system dynamics, nonlinearities, uncertainties and time-varying parameters within the physical substructures. This paper presents the substructuring approach and control performance of the linear and the adaptive controllers for testing the dynamic characteristics of soil-structure-interaction system (SSI). This is difficult to emulate as an entire system in the laboratory because of the size and power supply limitations of the experimental facilities. A modified linear substructuring controller (MLSC) is proposed to replace the linear substructuring controller (LSC).The MLSC doesn't require the accurate mathematical model of the physical structure that is required by the LSC. The effects of parameter identification errors of physical structure and the shaking table on the control performance of the MLSC are analysed. An adaptive controller was designed to compensate for the errors from the simplification of the physical model in the MLSC, and from parameter identification errors. Comparative simulation and experimental tests were then performed to evaluate the performance of the MLSC and the adaptive controller.

A Preliminary Study for the Analytical Method and Environmental Characteristics of Radium-226 in Groundwater (지하수 중 라듐-226의 분석방법 및 환경 특성에 관한 예비 연구)

  • Jeong, Do-Hwan;Kim, Moon--Su;Noh, Hoe-Jung;Yoon, Yoon-Yeol;Kim, Dong-Soo;Lee, Young-Joon;Ju, Byoung-Kyu;Hong, Jung-Ki;Kim, Tae-Seung
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.2
    • /
    • pp.22-27
    • /
    • 2012
  • $^{226}Ra$ in groundwater could be analyzed by various methods. LSC (liquid scintillation counter) is used to measure its activity of Ba co-precipitates with Hisafe III scintillation cocktail solution. Counting efficiency was obtained using NIST $^{226}Ra$ standard solution in triplicate and calculated $^{226}Ra$ concentration using the efficiency values. $^{226}Ra$ values of 19 groundwaters having Gross-${\alpha}$ concentrations of more than 5 pCi/L ranged from ND (${\leq}$ 0.1 pCi/L) to 1.18 pCi/L. Geologic settings of the 19 areas are composed of granitic rocks of Pre-Cambrian and Jurassic and Cretaceous, gneiss (schist) of Pre-Cambrian, and volcanic rocks of Cretaceous. No relationship was shown among $^{226}Ra$ a concentrations and in-situ water quality data, and Gross-${\alpha}$, uranium, radon concentrations.

Detection of Extremely Low Concentration Compound and Adsorption by Activated Carbon (극미량 농도 물질의 측정 및 활성탄 흡착 처리)

  • Lee, Sung-Bum;Yoon, Yeo-Min;Choi, Chang-Kyoo;Jung, Jin-Wook;Lee, Yong-Woo;Park, Se-Yong;Kim, Moon-Il
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.9
    • /
    • pp.913-917
    • /
    • 2008
  • Since the difficulty of analysis at low concentration and the uncertainty of the removal mechanism for Nitrosodimethylamine (NDMA) have been reported, this study has detected extremely low concentration $^{14}$C-NDMA using the LSC(Liquid Scintillation Counter) and tested NDMA removal by Powdered Activated Carbon(PAC). The results showed the highest correlation over 99% when samples were measured with the mixture ratio of sample to scintillation liquid of 10 : 10 and at the detection time of 10 min. For $^{14}$C-NDMA removal by the PACs(S-A(Sigma-Aldrich co.) and Dj(Daejung co.)) raging from 50$\sim$10,000 mg/L, $^{14}$C-NDMA was removed over 90% by adsorption treatment. In addition, S-A showed twice greater adsorption capacity than that of Dj. However, the required PAC amount for $^{14}$C-NDMA removal was higher than that of other amine compounds.

Performance evaluation and Applicable Possibility of $H_2O_2$ Gas Generator using Dual Catalyst System (이원 촉매를 이용한 과산화수소 가스발생기 성능평가 및 응용 가능성)

  • Rang Seong-Min;An Sung-Yong;Lim Ha-Young;Kwon Se-Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.347-350
    • /
    • 2006
  • The rocket grade hydrogen peroxide has been widely used as a monopropellant in propulsion systems. In the present paper, we described an experimental study of a catalytic reactor that employs two stage catalyst beds to enhance the low temperature performance of the reactor. $K_2MnO_4$ was chosen as the catalyst for the initial stage of the reactor bed for its superior behavior in the low temperature regime. LSC was used for the catalyst of the second stage of the reactor. The gas generator with combined catalyst beds was built and tested to exhibit high decomposition efficiency over 90% and successful cold-start characteristics.

  • PDF