• Title/Summary/Keyword: LSC

Search Result 167, Processing Time 0.033 seconds

Effects of Feeding Single or Multiple Probiotics on Performance and Intestinal Microflora of Broiler Chicks (단일 및 혼합 생균제의 급여가 육계의 생산성 및 장내 미생물에 미치는 영향)

  • 류경선;여영수;류명선;박홍석;김상호
    • Korean Journal of Poultry Science
    • /
    • v.28 no.1
    • /
    • pp.41-47
    • /
    • 2001
  • Two experiments were conducted to investigate the effents of feeding single or combined probiltics on performance and intestinal micreflora of broiler chicks for five weeks. Diets based on corn and soybean meal contained 21.50, 19% CP and 3,100, 3,150kcal/kg ME for starting and finishing period, respectively. Lactobacillus salvarius isolated from chicks intestine(LSC), Lactobacillus salvarius isolated from piglet(LSP), Bacillus polyfermenticus(BP) were fed with alone and mixed ones at the level of 0.21 and 0.1% in experiment 1 and 2, respectively. Three hundred eighty four chicks were randomly assigned to eight treatments with four replicates of 12 chicks each per treatment. Weight gain, feed consumption, feed conversion ratio(FCR) were weekly measured for 5 weeks. The number of intestinal micreflora was examined at the end of experiment. In both experiments, weight gain of chicks fed probiltics tended to be similar or higher than control, but was not in LSC+LSP treatment. Feed intake was not consistent among treatments. In experiment 1, FCR of chicks fed LSC alone was the lowest of all treatments, whereas it was significantly higher in LSC+LSP treatments than control(P〈0.05). In experiment 2, LSP supplemental groups tended to increase FCR compared to the control. The number of ileal E. coli was the lowest in LSP alone treatment of experiment 1, whereas cecal E. coli was higher concentration in probiotics supplemental groups than control. Total Lactobacillus of chicks fed probiotics was decreased in ileum, but was no consestency in cecum. In experiment 2, ileal total yeast tended to be higher in probiotics supplemental groups except LSP alone supplement than control. Total Lactobacillus of chicks fed LSC or LSP alone treatments was significantly higher than control(P〈0.05).

  • PDF

Evaluation of Xerostomia Following Intensity Modulated Radiotherapy (IMRT) for Head and Neck Cancer Patients (세기조절방사선치료를 시행받은 두경부암 환자군에서 구강건조증지표 분석)

  • Lee, Seok-Ho;Kim, Tae-Hyun;Chie, Eui-Kyu;Im, Hyun-Shun;Im, En-Shil;Ryu, Jun-Sun;Jung, Yoo-Seok;Park, Sung-Yong;Kim, Joo-Young;Pyo, Hong-Ryull;Shin, Kyung-Hwan;Kim, Dae-Yong;Cho, Kwan-Ho
    • Radiation Oncology Journal
    • /
    • v.22 no.2
    • /
    • pp.106-114
    • /
    • 2004
  • Purpose : This study was done to evaluate xerostomia fellowing intensity modulated radiotherapy for patients with head and neck cancer, and to analyze the correlation between the dosimetric parameters and xerostomia parameters. Materials and Methods : From February till October 2003, 13 patients with 3 months of follow-up were evaluated for xerostomia after being treated for head and neck cancer with IMRT. Their median age was 57 years(range: 43$\~$77). Xerostomia were assessed with a 4-question xerostomia questionnaire score (XQS) and a test for salivary flow rates (unstimulated and stimulated). The patients were also given a validated LENT SOMA scale (LSC) questionnaire. The evaluations were completed before radiation therapy (pre-RT) and at 1 and, 3 months after radiation therapy (RT). We evaluated xerostomia at pre-RT, 1 and, 3 months after RT. The association between the xerostomia parameters (XQS and LSC) and salivary flow rates (unstimulated and stimulated: USFR and SSFR) was assessed at 1 and 3 months after RT. Resrlts : All 13 patients showed no significant changes in XQS, LSC and Salivary Flow rates. As a result, we couldn't find out about xerostomia development. Based on the total mean parotid dose, 3,500 cGy, we divided these patients into two groups. The 8 patients (<3,500 cGy) showed no significant changes in XQS, LSC and Salivary Flow rates However, in 5 Patients ($\geq$3,500 cOGy), there was a significant increase in USFR and, SSFR at 3 months after RT, and for the XQS and, LSC at 1 and 3 months after RT. The correlation between XQS and, LSC, and USFR and, SSFR in ail patients (13) was significant at 3 months after RT. The correlation had a tendency to the decrease for USFR and, SSFR in proportion to the increase of XQS and, LSC. Conclusion : Based on the results of this study, IMRT seem to be an effective treatment to significantly decrease the xerostomia. XQS and, LSC seem to be a effective tool for predicting the xerostomia. A total parotid gland mean dose of <3,500 cGy should be a planning goal if substantial sparing of the gland function is desired. Furthermore, patients should be enrolled in a study to define a more accurate threshold dose for the parotid gland.

Performance Evaluation of Hydrogen Peroxide Vaporizer with $K_2MnO_4/Al_2O_3$ Catalyst ($K_2MnO_4/Al_2O_3$촉매를 이용한 과산화수소 기화기의 성능평가)

  • Rang Seong-Min;An Sung-Yong;Kwon Hyuck-Mo;Kwon Se-Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.329-334
    • /
    • 2005
  • The rocket grade hydrogen peroxide has been widely used as a monopropellant in propulsion systems. Conventional decomposition of hydrogen peroxide, however, requires preheating before feeding into the reactor. In the present paper, we described an experimental study of a catalytic reactor bed that employs multiple catalysts to enhance the low temperature response in the vicinity of the reactor inlet. $K_2MnO_4$ is experimentally chose as the inlet catalyst from the candidates of silver, platinum, $La_{0.8}Sr_{0.2}CoO_3(LSC),\;and\;K_2MnO_4$. We developed new synthesis and coating method using modified alumina sol-gel method to strengthen the adhesion of $K_2MnO_4$ catalyst. from the vaporizer experiment with hydrogen peroxide at room temperature, satisfactory vaporizing performance was measured.

  • PDF

Interpolation of GPS Receiver Clock Errors Using Least-Squares Collocation (Least-Squares Collocation을 이용한 GPS 수신기 시계오차 보간)

  • Hong, Chang-Ki;Han, Soohee
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.36 no.6
    • /
    • pp.621-628
    • /
    • 2018
  • More than four visible GPS (Global Positioning System) satellites are required to obtain absolute positioning. However, it is not easy to satisfy this condition when a rover is in such unfavorable condition as an urban area. As a consequence, clock-aided positioning has been used as an alternative method especially when the number of visible satellites is three providing that receive clock error information is available. In this study, LSC (Least-Squares Collocation) method is proposed to interpolate clock errors for clock-aided positioning after analyzing the characteristics of receiver clock errors. Numerical tests are performed by using GPS data collected at one of Korean CORS (Continuously Operating Reference Station) and a nearby GPS station. The receiver clock errors are obtained through the DGPS (Differential GPS) positioning technique and segmentation procedures are applied for efficient interpolation. Then, LSC is applied to predicted clock error at epoch which clock information is not available. The numerical test results are analyzed by examining the differences between the original and interpolated clock errors. The mean and standard deviation of the residuals are 0.24m and 0.49m, respectively. Therefore, it can be concluded that sufficient accuracy can be obtained by using the proposed method in this study.

Low level tritium analysis using liquid scintillation counter (액체섬광계수기를 이용한 저준위 트리튬 분석법연구)

  • Yoon, Yoon Yeol;Cho, Soo Young;Lee, Kil Yong;Kim, Yongje
    • Analytical Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.419-423
    • /
    • 2007
  • Environmental low level tritium analysis was studied using liquid scintillation counter(LSC) and electrolytic enrichment method. To obtain low level blank count, various counting vials were investigated. Among them, teflon coated PE vial had a lower blank count rate (1.86 cpm) and we obtained 2.01 Bq/L detection and tritium separation factor was above 20. LSC counting efficiency obtained $28.70{\pm}0.27%$ using the NIST tritium standard water sample.

Studies on the Shade Tolerance, Light Requirement, and Water Relations of Economic Tree Species(I) - Changes of Hydraulic Conductance of Six Deciduous Hardwood Species Subjected to Artificial Shade Treatments - (주요경제수종(主要經濟樹種)의 내음성(耐陰性) 및 광선요구도(光線要求度)와 수분특성(水分特性)에 관한 연구(硏究)(I) - 인공피음처리(人工被陰處理)를 실시(實施)한 낙엽활엽수(落葉闊葉樹) 6종(種)의 수분통도성(水分通道性) 변화(變化) -)

  • Kwon, Ki Won;Choi, Jeong Ho;Chung, Jin Chul
    • Journal of Korean Society of Forest Science
    • /
    • v.88 no.3
    • /
    • pp.292-298
    • /
    • 1999
  • Huber value and leaf specific conductivity were investigated for determining the hydraulic conductance of six deciduous hardwood species subjected to five levels of artificial shade treatments. Huber values measured in full sun were in the ranges of $1.5{\sim}9.1mm^2/dm^2$, $1.3{\sim}2.6mm^2/dm^2$, $1.5{\sim}5.3mm^2/dm^2$ in June, July, and September, respectively in the first year. The values generally decreased with increasing the shading in most of the species studied. Because of early defoliation in September, most of the values measured were also higher in September than in July. Huber values were quite different between those of the first year and those of the second year in most of the species studied, but the seasonal variation of Huber values and shading effects to the values seemed to be similar between the first and the second years. The values of leaf specific conductivity(LSC) measured in Betula platyphylla var. japonica. B. schmidtii, Zelkova serrata, Acer mono for 2 years were in the range of $4.0{\sim}80.0{\mu}{\ell}/dm^2$ by season and by shading treatment. But in Ligustrum obtusifolium and Prunus sargentii, the values were in the ranges of $4.0{\sim}280.0{\mu}{\ell}/dm^2$ and $8.0{\sim}120{\mu}{\ell}/dm^2$, respectively with having quite different values compared with those of the above species. Seasonal variation of LSC values was more or less irregular by species and by treatment year, but the LSC values of B. platyphylla vac. japonica, B. schmidtii, and P. sargentii in the first year and also those of Z. serrata and P. sargentii in the second year were mostly higher in September than in July. The LSC values seemed to be generally decreased with increasing the artificial shading in all of the species studied.

  • PDF

Cloning and Sequence Analysis of a Levansucrase Gene from Rahnella aquatilis ATCC15552

  • Kim, Hyun-Jin;Yang, Ji-Young;Lee, Hyeon-Gye;Cha, Jae-Ho
    • Journal of Microbiology and Biotechnology
    • /
    • v.11 no.4
    • /
    • pp.693-699
    • /
    • 2001
  • An intracellular levansucrase gene, lscR from Rahnella aquatilis ATCC 15552, was cloned and its nucleotide sequence was determined. Nucleotide sequence analysis of this gene revealed a 1,238 bp open reading frame coding for a protein of 415 amino acids. The levansucrase was expressed by using a T7 promoter in Escherichia coli BL21 (DE3) and the enzyme activity was detected in the cytoplasmic fraction. The optimum pH and temperature of this enzyme for levan formation was pH 6 and $30^{\circ}C$, respectively. The deduced amino acid sequence of the lscR gene showed a high sequence similarity (59-89%) with Gram-negative levansucrses, while the level of similarity with Gram-positive enzymes was less than 42%. Multiple alignments of levansucrase sequences reported from Gram-negative and Gram-positive bacteria revealed seven conserved regions. A comparison of the catalytic properties and deduced amino acid sequence of lscR with those of other bacterial levansucrases strongly suggest that Gram-negative and Gram-positive levansucrases have an overall different structure, but they have a similar structure at the active site.

  • PDF

Design Consideration of Bulk FinFETs with Locally-Separated-Channel Structures for Sub-50 nm DRAM Cell Transistors

  • Jung, Han-A-Reum;Park, Ki-Heung;Lee, Jong-Ho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.8 no.2
    • /
    • pp.156-163
    • /
    • 2008
  • We proposed a new $p^+/n^+$ gate locally-separated-channel (LSC) bulk FinFET which has vertically formed oxide region in the center of fin body, and device characteristics were optimized and compared with that of normal channel (NC) FinFET. Key device characteristics were investigated by changing length of $n^+$ poly-Si gate ($L_s$), the material filling the trench, and the width and length of the trench at a given gate length ($L_g$). Using 3-dimensional simulations, we confirmed that short-channel effects were properly suppressed although the fin width was the same as that of NC device. The LSC device having the trench non-overlapped with the source/drain diffusion region showed excellent $I_{off}$ suitable for sub-50 nm DRAM cell transistors. Design of the LSC devices were performed to get reasonable $L_s/L_g$ and channel fin width ($W_{cfin}$) at given $L_gs$ of 30 nm, 40 nm, and 50 nm.

A Study on the Heat Release Characteristic of Household Items using LSC(Large Scale Cone Calorimeter) (LSC를 이용한 생활용품의 발열량 특성에 관한 연구)

  • Park, Ju Young;Baek, Chang Sun;Lee, Hae Pyeong;Hong, Yi Pyo
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.3
    • /
    • pp.38-44
    • /
    • 2015
  • For this study, fire tests were performed targeting household items (Sofa, Drawer, Refrigerator, Washing machine) using a large cone calorimeter (Large Scale Cone Calorimeter, LSC). The data were obtained focusing on the fire characteristic of the data when the actual fire occurs. The study results showed the following mean HRR of the household items; drawer 2843 KW, sofa 2939 KW, washing machine 719 KW, refrigerator 2907 KW, and THR is found in sofa 2202 MJ, drawer 1559 MJ, refrigerator 1193 MJ, washing machine 627 MJ. From the result, it could be found that the sofa can cause significant heat generation when the fire occurs, and the flashover tendency was found relatively high in compartment fire. In addition, a weight of the four our household items was reduced sharply in a similar time (20min before and after) degree after ignition. The drawer and sofa which has a high heat release can be considered to speed up the fire spread as their weight decrease rapidly and showed relatively weak to the fire compared to the refrigerator and washing machine.

Differences in electric potential of meridian system -Comparing electrical potentials of patients with Lumbago due to strain and contusion- (좌섬요통 환자의 12경맥 전위측정 연구)

  • Choi, Hwan-soo;Nam, Bong-hyun
    • Journal of Acupuncture Research
    • /
    • v.21 no.5
    • /
    • pp.101-111
    • /
    • 2004
  • Objective : Assuming that the characteristic of meridian system has been similar to this of electric potentials in human body and that measurements of electric potential at well(井穴) and sea (合穴) points in branches of the twelve meridians(WSBTM) will be representative of measurements of the twelve meridians, to measure the electric potentials of 13 patients with Lumbago due to strain and contusion(좌섬요통<挫閃腰痛>, LSC), to find out the characteristic of meridian system in patients with LSC. Methods : Electric potentials of well and sea points in the meridians in twenty one patients with the pain in the lion diagnosed as LSC were repeatedly measured by physiograph(PowerLab). Measurements of those electrical potentials were analyzed by factor analysis. Results : The electric potentials of WSBTM at the left side were divided into four factors. On the other hand those at the right side Were divided into four factors. Conclusion : In conclusion, their electrical potentials at the left and right side were factors which are different from each side. Thus electrical potentials of well and sea points might be the representative meridian to show their characteristics.

  • PDF