• Title/Summary/Keyword: LR

Search Result 923, Processing Time 0.043 seconds

The Purification and Immunogenicity of TB-14 Recombinant Protein of Mycobacterium tuberculosis (결핵균 특이 TB-14 재조합 단백질의 분리 및 세포성 면역반응에 미치는 영향)

  • Song, Ho-Yeon;Kim, Young-Hee;Kim, Chang-Hwan;Min, Young-Ki;Kim, Dae-Joong;Ko, Kwang-Kjune
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.3
    • /
    • pp.239-247
    • /
    • 2006
  • Background: Culture filtrate proteins secreted by mycobacteria are thought to play an important role in inducing protective immunity and to develop new methods for diagnosing tuberculosis. Methods: A culture filtrate protein of M. avium that was strongly reactive with goat antiserum against M. intracellulare was constructed. Its homologous protein (TB-14) in M. tuberculosis was cloned, expressed and purified. The inductions of IFN-${\gamma}$ stimulated with $10{\mu}g$ of TB-14 recombinant protein and $10{\mu}g$ PPD were estimated by using whole bloods from seven PPD (-) subjects, seven PPD (+) healthy volunteers and nine tuberculosis patients. Results: M. avium culture filtrate protein was confirmed as a hypothetical protein that was termed contig 116. A novel 14-kDa recombinant protein (TB-14) of M. tuberculosis was composed of 148 amino acids, including 30 amino acids of the signal peptide, and it showed 78% homology with M. avium. In the PPD (+) healthy volunteers, recombinant TB-14 protein strongly induced the secretion of IFN-${\gamma}$ in whole blood cultures. Conclusion: These results suggest that TB-14 recombinant protein might play an important role in inducing cell-mediated immunity against tuberculosis. Furthermore, TB-14 protein antigen and its antiserum will be available for the development of new diagnostic tools for tuberculosis.

Development of Abdominal Compression Belt and Evaluation of the Efficiency for the Reduction of Respiratory Motion in SBRT (체부 정위방사선치료 시 호흡운동 감소를 위한 복부 압박기구 개발 및 유용성 평가)

  • Hwang, Seon-Bung;Kim, Il-Hwan;Kim, Woong;Im, Hyeong-Seo;Gang, Jin-Mook;Jeong, Seong-Min;Kim, Gi-Hwan;Lee, Ah-Ram;Cho, Yu-Ra
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.13-19
    • /
    • 2011
  • Purpose: It's essential to minimize the tumor motion and identify the exact location of the lesions to achieve the improvement in radiation therapy efficiency during SBRT. In this study, we made the established compression belt to reduce respiratory motion and evaluated the usefulness of clinical application in SBRT. Materials and Methods: We analyzed the merits and demerits of the established compression belt to reduce the respiratory motion and improved the reproducibility and precision in use. To evaluate the usefulness of improved compression belt for respiratory motion reduction in SBRT, firstly, we reviewed the spiral CT images acquired in inspiration and expiration states of 8 lung cancer cases, respectively, and analyzed the three dimensional tumor motion related to respiration. To evaluate isodose distribution, secondly, we also made the special phantom using EBT2 film (Gafchronic, ISP, USA) and we prepared the robot (Cartesian Robot-2 Axis, FARARCM4H, Samsung Mechatronics, Korea) to reproduce three dimensional tumor motion. And analysis was made for isodose curves and two dimensional isodose profiles with reproducibility of respiratory motion on the basis of CT images. Results: A respiratory motion reduction compression belt (Velcro type) that has convenient use and good reproducibility was developed. The moving differences of three dimensional tumor motion of lung cancer cases analyzed by CT images were mean 3.2 mm, 4.3 mm and 13 mm each in LR, AP and CC directions. The result of characteristic change in dose distribution using the phantom and rectangular coordinates robot showed that the distortion of isodose has great differences, mean length was 4.2 mm; the differences were 8.0% and 16.8% each for cranio-caudal and 8.1% and 10.9% each for left-right directions in underdose below the prescribed dose. Conclusion: In this study, we could develop the convenient and efficient compression belt that can make the organs' motion minimize. With this compression belt, we confirmed that underdose due to respiration can be coped with when CTV-PTV margins of mean 6 mm would be used. And we conclude that the respiratory motion reduction compression belt we developed can be used for clinical effective aids along with the gating system.

  • PDF

Cyanobacteria and Secondary Metabolites (시아노박테리아의 이차대사물질에 대한 연구)

  • Kim, Gi-Eun;Kwon, Jong-Hee
    • KSBB Journal
    • /
    • v.22 no.5
    • /
    • pp.356-361
    • /
    • 2007
  • Cyanobacteria are a very old group of prokaryotic organisms that produce very diverse secondary metabolites, especially non-ribosomal peptide and polyketide structures. Although some cyanobacteria produce lethal toxins such as microcystins and anatoxins, some may be useful either for development into commercial drugs or as biochemical tools. Detection of unknown secondary metabolites was carried in the present study by a screening of 98 cyanobacterial strains from Cyanobiotech GmbH in order to establish a screening process, isolate pure substances and determine their bioactivities. A degenerated polymerase chain reaction technique as molecular approaches has been used for general screening of NRPS gene and PKS gene in cyanobacteria. A putative PKS gene was detected by DKF/DKR primer in 38 strains (38.8%) and PCR amplicons resulted from a presence of NRPS gene were showed by MTF2/MTR2 primer in 30 strains (30.6%), respectively. A screening of interesting strains was performed by comparing PCR screening results with HPLC analyses of extracts. HPLC analysis for a detection of natural products was performed in extracts from biomass. 5 strains were screened for further scale-up processing. 7 pure substances were isolated from the scale-up cultures and tested for bioactivities under consideration to purity, amount and molecular weight of substances. One substance isolated from CBT 635 showed cytotoxic activity. This substance may be regarded as Microcystin LR.

유전공학기법으로 변형시킨 내성유전자네 대한 수질환경에서의 전이동태

  • 이성기;김치경
    • Korean Journal of Microbiology
    • /
    • v.30 no.4
    • /
    • pp.322-331
    • /
    • 1992
  • In order to understand the transfer and behavior of R gene in water environments. the Kmr gene in the genetically modified microorganisms(GMMs) w,is studied by conjugation. The plasmid variously rearranged in the conjugants were comparatively analyzied by agarosc gel electrophoresis and the specific Km' genes in the gel were tletected with DNA probe. The Kmr genes of the GMM strains(DKC600 and DKC601) were transferred at higher rate than those of natural isola~e(DKI)b, ut the ratc was a little diflurent depending upon the recipient strains. Rearrangement of the plasmids appeared morc drastic in GMM strains than in IIKI as donor. The transfer frequencies of the Km' genes in LR broth were remarkably higher than in the water of AW and FW without regards to the strains. In LA breth. the frequencies of Kmr genes were higher at 25'C-30$^{\circ}$C than at 10$^{\circ}$C and at pH - 7 than pH 9, but temperature and pH of the FW did n,,t affect to the frequency. And the conjugants from GMM strains in FW did not showed any plasmids. except tor 43 kb plasmiil. As results of Southern analysis of the plasmid, variously rearranged in eonjugant cells obtained in LB broth, the Kmr genes were detected at the same position of Km' plasrnids of the donor cell(DK1 and GMM strains). But Km' plasmid disappeared in the conjugants obtained in F'W and their chronlosomes showed strong signal of hybridization. The Kmr plasmid of DKl in the conjugants obtained in FW water was transferred and maintained its size, but the Kmr plasinids of the GMM strains were all integrated into chromosome. Therefore, the Kmr plasmids of DKI anit GMM strains in LH were intactly transferred and other plasmitls were variously rearranged. but Km' gene of DKC600 in FW water was integrated into the chromosorn: without regards to the temperature and pH of the water.

  • PDF

Application of Modified Mupit for the Recurrent Vulva Cancer in Brachytherapy (재발한 Vulvar 종양의 근접치료 시 Modified Mupit Applicator의 적용)

  • Kim, Jong-Sik;Jung, Chun-Young;Oh, Dong-Gyoon;Song, Ki-Won;Park, Young-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.1
    • /
    • pp.13-19
    • /
    • 2006
  • Purpose: To evaluate whether modified MUPIT applicator can effectively eradicate recurrent tumor in uterine cervix cancer and reduce rectal complication after complete radiation treatment. Materials and Methods: Modified MUPIT applicator basically consists of an acrylic cylinder with flexible brain applicator, an acrylic template with a predrilled array of holes that serve as guides for interstitial needles and interstitial needles. CT scan was peformed to determine tumor volume and the position of interstitial needles. Modified MUPIT applicator was applied to patient in operation room and the accuracy for position of interstitial needles in tumor volume was confirmed by CTscan. Brachytherapy was delivered using modified MUPIT applicator and RALS(192-lr HDR) after calculated computer planning by orthogonal film. The daily dose was 600cGy and the total dose was delivered 3,000 cGy in tumor volume by BID. Rectal dose was measured by TLD at 5 points so that evaluated the risk of rectal complication. Results: The application of modified MUPIT applicator improved dramatically dose distributions in tumor volume and follow-up of 3 month for this patient was clinically partial response without normal tissue complication, Rectal dose was measured 34.1 cGy, 57.1 cGy, 103.8 cGy, 162.7 cGy, 165.7 cGy at each points, especially the rectal dose including previous EBRT and ICR was 34.1 cGy, 57.1 cGy. Conclusion: Patients with locally recurrent tumor in uterine cervix cancel treated with modified MUPIT applicator can expect reasonable rates of local control. The advantages of the system are the fixed geometry provided by the template and cylinders. and improved dose distributions in irregular tumor volume without rectal complication.

  • PDF

Wildfire Severity Mapping Using Sentinel Satellite Data Based on Machine Learning Approaches (Sentinel 위성영상과 기계학습을 이용한 국내산불 피해강도 탐지)

  • Sim, Seongmun;Kim, Woohyeok;Lee, Jaese;Kang, Yoojin;Im, Jungho;Kwon, Chunguen;Kim, Sungyong
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.5_3
    • /
    • pp.1109-1123
    • /
    • 2020
  • In South Korea with forest as a major land cover class (over 60% of the country), many wildfires occur every year. Wildfires weaken the shear strength of the soil, forming a layer of soil that is vulnerable to landslides. It is important to identify the severity of a wildfire as well as the burned area to sustainably manage the forest. Although satellite remote sensing has been widely used to map wildfire severity, it is often difficult to determine the severity using only the temporal change of satellite-derived indices such as Normalized Difference Vegetation Index (NDVI) and Normalized Burn Ratio (NBR). In this study, we proposed an approach for determining wildfire severity based on machine learning through the synergistic use of Sentinel-1A Synthetic Aperture Radar-C data and Sentinel-2A Multi Spectral Instrument data. Three wildfire cases-Samcheok in May 2017, Gangreung·Donghae in April 2019, and Gosung·Sokcho in April 2019-were used for developing wildfire severity mapping models with three machine learning algorithms (i.e., Random Forest, Logistic Regression, and Support Vector Machine). The results showed that the random forest model yielded the best performance, resulting in an overall accuracy of 82.3%. The cross-site validation to examine the spatiotemporal transferability of the machine learning models showed that the models were highly sensitive to temporal differences between the training and validation sites, especially in the early growing season. This implies that a more robust model with high spatiotemporal transferability can be developed when more wildfire cases with different seasons and areas are added in the future.

Development of Immobilization Devices for Patients with Pelvic Malignancies and a Feasibility Evaluation during Radiotherapy (골반부 암 환자를 위한 고정기구 개발 및 방사선치료 시 효용성 평가)

  • Park, Jong-Min;Park, Yang-Kyun;Cho, Woong;Park, Charn-Il;Ha, Sung-Whan
    • Radiation Oncology Journal
    • /
    • v.25 no.2
    • /
    • pp.134-144
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: Immobilization devices that improve the setup reproducibility of pelvic cancer patients and that provide comfort to patients during radiotherapy were designed and the feasibility of the devices was evaluated. $\underline{Materials\;and\;Methods}$: A customized device was designed to immobilize a knee, thigh, and foot of a patient. Sixty-one patients with prostate cancer were selected and were divided into two groups-with or without devices. The setup errors were measured with respect to bony landmarks. The difference between digitally reconstructed radiographs (DRR) and simulation films, and the differences between DRR and portal films were measured. $\underline{Results}$: The left-right (LR), anterior-posterior (AP) and craniocaudal (CC) errors between the DRR and simulation films were $1.5{\pm}0.9\;mm$, $3.0{\pm}3.6\;mm$, and $1.6{\pm}0.9\;mm$, respectively without devices. The errors were reduced to $1.3{\pm}1.9\;mm$, $1.8{\pm}1.5\;mm$ and $1.1{\pm}1.1\;mm$, respectively with the devices. The errors between DRR and portal films were $1.6{\pm}1.2\;mm$, $4.0{\pm}4.1\;mm$, and $4.2{\pm}5.5\;mm$, respectively without the devices and were reduced to $1.0{\pm}1.8\;mm$, $1.2{\pm}0.9\;mm$, and $1.2{\pm}0.8\;mm$, respectively, with the devices. The standard deviations among the portal films were 1.1 mm, 2.1 mm, and 1.0 mm at each axis without the devices and 0.9 mm, 1.6 mm and 0.8 mm with the devices. The percentage of setup errors larger than 3 mm and 5 mm were significantly reduced by use of the immobilization devices. $\underline{Conclusion}$: The designed devices improved the setup reproducibility for all three directions and significantly reduced critical setup errors.

Evaluation of Real-time Measurement Liver Tumor's Movement and $Synchrony^{TM}$ System's Accuracy of Radiosurgery using a Robot CyberKnife (로봇사이버나이프를 이용한 간 종양의 실시간 움직임 측정과 방사선수술 시 호흡추적장치의 정확성 평가)

  • Kim, Gha-Jung;Shim, Su-Jung;Kim, Jeong-Ho;Min, Chul-Kee;Chung, Weon-Kuu
    • Radiation Oncology Journal
    • /
    • v.26 no.4
    • /
    • pp.263-270
    • /
    • 2008
  • Purpose: This study aimed to quantitatively measure the movement of tumors in real-time and evaluate the treatment accuracy, during the treatment of a liver tumor patient, who underwent radiosurgery with a Synchrony Respiratory motion tracking system of a robot CyberKnife. Materials and Methods: The study subjects included 24 liver tumor patients who underwent CyberKnife treatment, which included 64 times of treatment with the Synchrony Respiratory motion tracking system ($Synchrony^{TM}$). The treatment involved inserting 4 to 6 acupuncture needles into the vicinity of the liver tumor in all the patients using ultrasonography as a guide. A treatment plan was set up using the CT images for treatment planning uses. The position of the acupuncture needle was identified for every treatment time by Digitally Reconstructed Radiography (DRR) prepared at the time of treatment planning and X-ray images photographed in real-time. Subsequent results were stored through a Motion Tracking System (MTS) using the Mtsmain.log treatment file. In this way, movement of the tumor was measured. Besides, the accuracy of radiosurgery using CyberKnife was evaluated by the correlation errors between the real-time positions of the acupuncture needles and the predicted coordinates. Results: The maximum and the average translational movement of the liver tumor were measured 23.5 mm and $13.9{\pm}5.5\;mm$, respectively from the superior to the inferior direction, 3.9 mm and $1.9{\pm}0.9mm$, respectively from left to right, and 8.3 mm and $4.9{\pm}1.9\;mm$, respectively from the anterior to the posterior direction. The maximum and the average rotational movement of the liver tumor were measured to be $3.3^{\circ}$ and $2.6{\pm}1.3^{\circ}$, respectively for X (Left-Right) axis rotation, $4.8^{\circ}$ and $2.3{\pm}1.0^{\circ}$, respectively for Y (Crania-Caudal) axis rotation, $3.9^{\circ}$ and $2.8{\pm}1.1^{\circ}$, respectively for Z (Anterior-Posterior) axis rotation. In addition, the average correlation error, which represents the treatment's accuracy was $1.1{\pm}0.7\;mm$. Conclusion: In this study real-time movement of a liver tumor during the radiosurgery could be verified quantitatively and the accuracy of the radiosurgery with the Synchrony Respiratory motion tracking system of robot could be evaluated. On this basis, the decision of treatment volume in radiosurgery or conventional radiotherapy and useful information on the movement of liver tumor are supposed to be provided.

The Effect of Acupuncture Treatment on the Heart Rate Variability of Chronic Headache Patients (만성두통환자에 대한 침치료가 심박변이도에 미치는 영향)

  • Jung, In-tae;Lee, Sang-hoon;Kim, Su-young;Cha, Nam-hyun;Kim, Keon-sik;Lee, Doo-ik;Lee, Jae-Dong;Lim, Sabina;Lee, Yun-ho;Choi, Do-young
    • Journal of Acupuncture Research
    • /
    • v.22 no.3
    • /
    • pp.105-112
    • /
    • 2005
  • Obiective : The purpose of this study was to assess the effect of acupuncture treatment for chronic headache patients using power spectrum analysis of the heart rate variability(HRV). Methods : 15 clinical experiment participants were gathered and through a questionnaire patients who experienced headache for more than 4 hours a day and more than IS days per month were qualified as Chronic Headache patients. Treatment was afplied 2 times a weeks for 8 weeks. The acupoints, GV2O, HN23, ST8, HN46, TEl7, GB2O, LI2O, LI11, LI14, ST36, and LR3 were stimulated for 20 minutes. The effects of acupuncture treatment were analyzed using power spectrum analysis of the HRV. HRV was recorded before and after acupuncture treatment. Results : HRV before and after treatment was compared after 8 weeks of acupuncture treatment. Increase in mean values of SDNN and RMSSD were observed but the increases were not statistically significant. Increase in mean values of TP, LF and HF were observed but, the increase was significant(p<0.05) only in TP. Conclusions : The results suggest that acupuncture treatment on chronic headache patients can increase the activity of autonomic nervous system. Further use of HRV for quantitative analysis of acupuncture treatment on autonomic nervous system related symptoms is suggested.

  • PDF

A clinical study of East-West Pain Treatment on Chronic Headach Patients (만성두통환자에 대한 동서협진의 임상적 연구)

  • Jung, In-tae;Lee, Sang-hoon;Kim, Su-young;Cha, Nam-hyun;Kim, Keon-sik;Lee, Doo-ik;Lee, Jae-Dong;Lim, Sabina;Lee, Yun-ho;Choi, Do-young
    • Journal of Acupuncture Research
    • /
    • v.22 no.3
    • /
    • pp.93-104
    • /
    • 2005
  • Objective : Because the cause and etiology of chronic headache are not yet fully explained, the treatment of this symptom is not simple. In order to study the effectiveness of East-West pain treatment on chronic headache, we evaluated its effect of pain alleviation and quality of life improvement on chronic headache patients who were treated with nerve block and acupuncture, and only acupuncture for eight weeks. Methods : 92 clinical experiment participants were gathered and through a questionnaire patients who experienced headache for more than 4 hours a day and more than 15 days per month were qualified as chronic headache patients. The qualified patients were classified into two groups, nerve block and acupuncture group(EW group, n=49) and acupuncture group(E group, n=43). Treatment was applied 2 times a weeks for 8 weeks. The acupoints, GV20, HN23, ST8, HN46, TE17, GB20, LI20O, LI11, LI14, ST36, and LR3 were stimulated for 20 minutes. The effects of two groups were analyzed using VAS scores and BPI(Brief Pain Inventory).

  • PDF