• Title/Summary/Keyword: LOD and LOQ

Search Result 298, Processing Time 0.026 seconds

Cyanide detection based on natural dyes reaction from blue butterfly pea flowers (Clitoria Ternatea)

  • Chotichayapong, Chatrachatchaya;Kuchaiyaphum, Pusita;Butwong, Nutthaya;Bua-ngern, Worapong
    • Analytical Science and Technology
    • /
    • v.35 no.4
    • /
    • pp.153-160
    • /
    • 2022
  • A green spectrophotometric method for the determination of cyanide has been proposed using, a green reagent, aqueous extract of blue butterfly pea. The test tube was filled with anthocyanin rich extract (pH 6) and cyanide solution. The reaction was kept constant for 10 minutes at room temperature. The reaction mixture changed color from blue to green as the amount of CN-ions increased. The 620 nm peak intensity increased with CN concentration. Therefore, this wavelength was used for all cyanide analyses. The cyanide calibration curve had a linear range of 0.25-1.00, 1.00-4.00, and 4.00-10.00 mg/L, with a satisfactory correlation coefficient of 0.99 and a LOD of 0.57 mg/L. The recovery ranged from 8.33 to 76.94 percent, indicating that this method is inaccurate at low cyanide concentrations. The intra-day and intermediate precision relative deviations were 0.391-0.871 % and 1.112-1.583 %. An H-bond forms between the C-4 group of the B-carbonyl ring and the HCN molecule according to the B3LYP/TZVP calculation. The method is convenient for cyanide concentrations above the LOQ of 1.09 mg/L, cost-effective, and capable of reducing toxic solvents with acceptable precision. The method could also be used to detect total cyanide in biological, environmental, and industrial waste samples.

Simultaneous Analysis of Cholesterol Oxidation Products (COPs) in Powdered Milk Using HPLC/UV-Vis

  • Lee, Jin Joo;Myung, Seung-Woon
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.9
    • /
    • pp.2787-2794
    • /
    • 2013
  • Cholesterol and cholesterol oxidation products (COPs) may accumulate in foods of animal origin during processing or storage. An effective and sensitive analytical method was developed by increasing the UV absorption of compounds through derivatization by attaching a chromophore to the functional groups of cholesterols (cholesterol, 20-hydroxycholesterol, 7-ketocholesterol, cholestane-$3{\beta}$-$5{\alpha}$-$6{\beta}$-triol, 25-hydroxycholesterol, and $5,6{\alpha}$-epoxycholesterol). The influences of the reaction time, volume of reaction solvent, amounts of derivatizing reagent, and extraction solvents were investigated, as they may influence the reaction and extraction yield. The derivatized COPs were analyzed simultaneously on a C18 column (2.1 mm i.d. ${\times}$ 100 mm length, $3.5{\mu}m$ particle size) using a gradient elution with water and acetonitrile. The derivatized COPs showed increased sensitivity and selectivity in HPLC/UV-Vis. The LOD and LOQ were in the concentration ranges of 0.018-0.55 mg/kg and 0.059-1.84 mg/kg from the powdered milk. And the accuracy and precision were 78.1-116.7% and 1.1-9.9%, respectively.

Poly(dimethylsiloxane) Mini-disk Extraction

  • Cha, Eun-Ju;Lee, Dong-Sun
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.10
    • /
    • pp.3603-3609
    • /
    • 2011
  • A novel sampling method of the headspace poly(dimethylsiloxane) (PDMS) mini-disk extraction (HS-PDE) was developed, optimized, validated and applied for the GC/MS analysis of spices flavors. A prototype PDMS mini-disk (8 mm outer diameter, 0.157 mm thickness, 9.4 mg weight) has been designed and fabricated as a sorption device. The technique uses a small PDMS mini-disk and very small volume of organic solvent and less sample size than the solvent extraction. This new HS-PDE method is very simple to use, inexpensive, rapid, requires less labor. Linearities of calibration curves for ${\alpha}$-pinene, ${\beta}$-pinene, limonene and ${\gamma}$-terpinene by HS-PDE combined with GC/MS were excellent having $r^2$ values greater than 0.99 at the dynamic range of 6.06~3500 ng/mL. The limit of detection (LOD) and the limit of quantitation (LOQ) showed very low values. This method exhibited good precision and accuracy. The overall extraction efficiency of this method was evaluated by using partition coefficients ($K_p$) and concentration factors (CF) for several characteristic components from nutmeg and mace. Partition coefficients were in the range from $2.04{\times}10^4$ to $4.42{\times}10^5$, while CF values were 0.88-15.03. HS-PDE was applied successfully for the analysis of flavors compositions from nutmeg, mace and cumin. The HS-PDE method is a very promising sampling technique for the characterization of volatile flavors.

Determination of Polar Secondary Metabolomes in Arabidopsis thaliana using High Performance Liquid Chromatography Coupled with Tandem Mass Spectrometry

  • Cho, Young-Ah;Park, Se-min;Bae, Dong-Won;Seo, On-Nuri;Lee, Ji-Eun;Jeong, Sung-Woo;Kwon, Young-Sang;Cha, Jae-Yul;Bae, Han-Hong;Shin, Sung-Chul
    • Journal of agriculture & life science
    • /
    • v.46 no.6
    • /
    • pp.165-171
    • /
    • 2012
  • As a preceding study for investigating the influence of sound wave stimulus on Arabidopsis thaliana metabolomics, the polar secondary metabolomes of the plant were determined using high performance liquid chromatography coupled with tandem mass spectrometry. A total of 10 polar secondary metabolomes were characterized and quantified. Among them, 4 metabolomes, p-coumaroylagmatine isomer (7 and 8), p-coumaroylagmatine isomer (9 and 10) were identified in the plant for the first time. The validation was conducted in terms of linearity, recovery, precision, limit of detection (LOD) and limit of quantification (LOQ). The validated method was applied to the simultaneous quantification of the 10 polar secondary metabolomes.

Study on Extraction Condition and Analysis Methods of Benzopyrene in Black Ginseng (흑삼에서 벤조피렌의 추출 조건 및 분석 방법에 관한 연구)

  • Cho, Young-Ho;Song, Kyu-Yong;Baek, Myoung-Ki;Lee, Jong-Wha;Lee, Gye-Won
    • YAKHAK HOEJI
    • /
    • v.56 no.3
    • /
    • pp.145-151
    • /
    • 2012
  • To develop fundamental data of herbal materials with heat treatment, we studied analytical and extraction methods of benzopyrene in black ginseng and validated by HPLC analysis. Benzopyrene was successfully separated in mobile phase of acetonitrile:water (80 : 20) and detection of excitation 294 nm, emission 404 nm. The calibration curve of benzopyrene was linear over the concentration range of 1.17~37.50 ng/ml with correlation coefficient of above 0.999. The limit of detection (LOD) and quantitation (LOQ) of benzopyrene was 0.25 and 0.75 ng/ml, respectively. Hexane extraction method was used as a new extraction method for benzopyren and the efficient of extraction was over 95%. In conclusion, analytical method and extraction method were suitable for the determination of benzopyrene in the black ginseng and could be applied to fundamental study and guideline of herbal materials with heat treatment.

Validation of an Extraction Method for the Determination of Airborne MWFs using Alternative Solvents (대체용매를 이용한 금속가공유 측정방법 타당성 평가)

  • Jeong, Jee Yeon;Baek, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.2
    • /
    • pp.91-100
    • /
    • 2006
  • The purpose of this study was to validate alternative method by using non-carcinogenic, and less toxic solvents than NIOSH analytical method 5524 for measuring the airborne MWFs in workplaces. In laboratory tests, the ETM solvents(mixture of same volume for ethyl ether, toluene, and ethanol) were selected. The alternative method of analyzing MWFs, referred to as the ETM solvent extraction method, showed 0.04 mg/sample as LOD, and 0.15 mg/sample as LOQ. The analytical precision (pooled CV, coefficient of variation) of the ETM solvent extraction method for analyzing the straight, soluble, semisynthetic, and synthetic metalworking fluid was 1.5%, 2.0%, 2.6%, 1.6%, respectively, which was similar to the precision (2.6%) of NIOSH analytical method (NIOSH 0500) for total dust. The analytical accuracy by recovery test, spiked mass calculated as extractable mass, was almost 100%. As the result of storage stability test, metalworking fluid samples should be stored in refrigerated condition, and be analyzed in two weeks after sampling. The 95% confidence limit of the estimated total standard error for the ETM solvent extraction method for analyzing the straight, soluble, semisynthetic, and synthetic metalworking fluid was ${\pm}12.6%$, ${\pm}12.5%$, ${\pm}14.0%$, and ${\pm}13.6%$, respectively, which satisfied the OSHA sampling and analytical criteria.

A study on selenium quantification using ICP-MS with oxygen reactive gas in soil of Korea

  • Hyun-Young Kim;Young-Kyu Hong;Jin-Wook Kim;Sung-Chul Kim
    • Analytical Science and Technology
    • /
    • v.37 no.4
    • /
    • pp.230-238
    • /
    • 2024
  • This study evaluates a method for quantifying selenium (Se) concentration in soil using inductively coupled plasma mass spectrometry (ICP-MS), with oxygen as a reaction gas. This approach addresses the challenge of detecting low levels of Se in complex soil matrices and aims to effectively minimize interference problems typically associated with argon plasma in traditional ICP-MS analyses. The analytical method utilizes conditions optimized for minimizing spectral interference and were validated by linearity, accuracy, precision, limit of detection (LOD), and limit of quantification (LOQ). The method demonstrated good linearity, high accuracy (90-97 %), and remarkable sensitivity, achieving detection and quantification limits of 0.15 ㎍/kg and 0.44 ㎍/kg, respectively. Developed analysis method for Se in soil was applied to field samples in the different regions of South Korea and Se concentration ranged from 0.11 to 0.52 mg/kg. Correlation analysis between Se concentration and soil properties showed that Se concentration was significantly correlated with cation exchange capacity (CEC) and available phosphorus among other soil properties.

Quantitative Analysis of the Seven Marker Components in Asarum sieboldii using the LC-MS/MS and GC-MS (LC-MS/MS와 GC-MS를 이용한 세신 추출물 중 7종 성분의 함량분석)

  • Seo, Chang-Seob;Shin, Hyeun-Kyoo
    • Korean Journal of Pharmacognosy
    • /
    • v.44 no.4
    • /
    • pp.350-361
    • /
    • 2013
  • Asarum sieboldii has been used for treatment of fever, pain, common cold, and chronic sinusitis in Korea. In this study, we performed quantification analysis of seven major constituents including aristolochic acid I, aristolochic acid II, ${\alpha}$-asarone, ${\beta}$-asarone, elemicin, methyl eugenol, and safrole in the 70% ethanol extract of Asarum sieboldii and its solvent fractions, n-hexane, ethylacetate, n-butanol, and water ones using a ultra-performance liquid chromatography-electrospray ionization-mass spectrometer(UPLC-ESI-MS) and gas chromatography-mass spectrometer(GC-MS). Regression equations of seven components were acquired with $r^2$ values >0.99. The values of limit of detection(LOD) and quantification(LOQ) were 0.1-3.9 ng/mL and 0.3-11.7 mg/mL, respectively. The amount of the seven compounds in Asarum sieboldii were not detected -143.66 mg/g. The established LC-MS/MS and GC-MS methods will be helpful to improve quality control of Asarum sieboldii.

Analysis of Flavor Composition of Coriander Seeds by Headspace Mulberry Paper Bag Micro-Solid Phase Extraction

  • Cha, Eun-Ju;Won, Mi-Mi;Lee, Dong-Sun
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.11
    • /
    • pp.2675-2679
    • /
    • 2009
  • This paper reports the example of headspace mulberry paper bag micro solid phase extraction (HS-MPB-$\mu$-SPE) as a new sampling method for the determination of volatile flavor composition of coriander seeds. Adsorption efficiencies between two configurations of mulberry paper bag were compared, and several parameters affecting the HS-MPB-$\mu$-SPE were investigated and optimized. The optimized technique uses an adsorbent (Tenax TA, 0.1 mg) contained in a mulberry paper bag of front configuration where fine surface was outside, and minimal amount of organic solvent (0.6 mL). Linalool and $\gamma$-terpinene were found as abundant flavor compounds from coriander seeds. The limit of detection (LOD) and the limit of quantitation (LOQ) for linalool of major flavor in coriander seeds were 10.3 ng/mL and 34.4 ng/mL, respectively. The proposed method showed good reproducibility and good recovery. The HS-MPB-$\mu$-SPE is very simple to use, inexpensive, requires small sample amounts and solvent consumption. Because the solvent for extraction is reduced to only a very small volume, there is minimal waste or exposure to toxic organic solvent and no further concentration step.

Validation of a Real-Time RT-PCR Method to Quantify Newcastle Disease Virus (NDV) Titer and Comparison with Other Quantifiable Methods

  • Jang, Juno;Hong, Sung-Hwan;Kim, Ik-Hwan
    • Journal of Microbiology and Biotechnology
    • /
    • v.21 no.1
    • /
    • pp.100-108
    • /
    • 2011
  • A method for the rapid detection and quantification of Newcastle disease virus (NDV) produced in an animal cell culture-based production system was developed to enhance the speed of the NDV vaccine manufacturing process. A SYBR Green I-based real-time RT-PCR was designed with a conventional, inexpensive RT-PCR kit targeting the F gene of the NDV LaSota strain. The method developed in this study was validated for specificity, accuracy, precision, linearity, limit of detection (LOD), limit of quantification (LOQ), and robustness. The validation results satisfied the predetermined acceptance criteria. The validated method was used to quantify virus samples produced in an animal cell culture-based production system. The method was able to quantify the NDV samples from mid- or late-production phases, but not effective on samples from the early-production phase. For comparison with other quantifiable methods, immunoblotting, plaque assay, and tissue culture infectious dose 50 ($TCID_{50}$) assay were also performed with the NDV samples. The results demonstrated that the real-time RT-PCR method is suitable for the rapid quantification of virus particles produced in an animal cell-culture-based production system irrespective of viral infectivity.