• 제목/요약/키워드: LNG Cargo Containment

검색결과 75건 처리시간 0.028초

Comparative Study on the Thermal Insulation of Membrane LNG CCS by Heat Transfer Analysis (열전달 해석을 이용한 멤브레인형 LNG 화물창의 단열구조 성능비교)

  • Hwang, Se-Yun;Lee, Jang-Hyun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • 제29권1호
    • /
    • pp.53-60
    • /
    • 2016
  • This study discusses the thermal insulation capacity of variant of NO96 LNG (liquefied natural gas) cargo containment insulation system. Changing the insulation materials and the insulation layers of conventional GTT NO96 containment system, The thermal resistance and BOR(boil off rate) caused by the heat transfer between cryogenic and environmental temperature is discussed. Therefore, thermal analysis of LNG CCS(cargo containment system) is carried out to determine the insulation capabilities. Also, BOR is evaluated in terms of the total amount of heat invaded into CCS(cargo containment system). Variant of NO96 CCS such as NO96, NO96GW and NO96L3 membrane type during laden voyage is selected for the comparative study. Finite element model for heat transfer analysis is conducted by employing the equivalent thermal resistance model to simplify the complex insulation layers. Finally the results for each variant model are relatively compared and discussed to minimize the BOR.

A Study on the Boil-Off Rate Prediction of LNG Cargo Containment Filled with Insulation Powders (단열 파우더를 채용한 LNGCC의 BOR예측에 관한 연구)

  • Han, Ki-Chul;Hwang, Soon-Wook;Cho, Jin-Rae;Kim, Joon-Soo;Yoon, Jong-Won;Lim, O-Kaung;Lee, Shi-Bok
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • 제24권2호
    • /
    • pp.193-200
    • /
    • 2011
  • A BOR(Boil-Off Rate) prediction model for the NO96 membrane-type LNG insulation containment filled with superlite powders during laden voyage is presented in this paper. Finite element model for the unsteady-state heat transfer analysis is constructed by considering the air and water conditions and by employing the homogenization method to simplify the complex insulation material composition. BOR is evaluated in terms of the total amount of heat invaded into LNGCC and its variation to the major variables is investigated by the parametric heat transfer analysis. Based upon the parametric results, a BOR prediction model which is in function of the LNG tank size, the insulation layer thickness and the powder thermal conductivity is derived. Through the verification experiment, the accuracy of the derived prediction model is justified such that the maximum relative difference is less than 1% when compared with the direct numerical estimation using the FEM analysis.

Investigation of the Bonding Stress of the 2nd Barrier for LNG Carrier Cargo Containment System Considering Various Working Conditions (다양한 작업 조건을 고려한 LNG 운반선 화물창 2차 방벽의 극저온 접착강도 분석)

  • Jeong-Hyeon Kim;Hee-Tae Kim;Byeong-Kwan Hwang;Seul-Kee Kim;Tae-Wook Kim;Doo-Hwan Park;Jae-Myung Lee
    • Journal of the Korean Society of Industry Convergence
    • /
    • 제26권3호
    • /
    • pp.499-507
    • /
    • 2023
  • The core of the liquefied natural gas (LNG) carrier cargo containment system (CCS) is to store and transport LNG safely under temperatures below -163 degrees Celsius. The secondary barrier of the LNG CCS is adopted to prevent LNG leakage from CCS to the ship's hull structure. Recently, as the size of the LNG CCS increases, various studies have been conducted on the applied temperature and load ranges. The present study investigates the working condition-dependent bonding strength of the PU15 adhesives of the secondary barrier. In addition, the mechanical performance is analyzed at a cryogenic temperature of -170 degrees Celsius, and the failure surface and failure mode are investigated depending on the working condition of the bonded process. Even though the RSB and FSB-based fracture mode was confirmed, the results showed that all the tested scenarios satisfied the minimum requirement of the regulation.

Structural Strength Assessment of Simplified Mark III CS Plate (단순화된 Mark III 방열판의 구조 강도 평가에 관한 연구)

  • Jeong, Han-Koo;Yang, Young-Soon
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 한국전산구조공학회 2011년도 정기 학술대회
    • /
    • pp.539-543
    • /
    • 2011
  • LNG cargo containment system (CCS) has the primary function of ensuring adequate thermal insulation with keeping natural gas below its boiling point. From the viewpoint of structural design, this LNG CCS can be treated as a laminated composite structure showing complex structural responses under the sloshing load which can be defined as a violent behavior of the liquid contents in cargo tanks due to external forced motions. As LNG CCS type, Mark III containment system from TGZ is considered in this paper and then its structural strength assessment is performed based on a simple higher-order shear deformation theory and maximum stress, maximum strain, Tsai-Wu failure criteria developed for laminated composite plates. The assessment is performed to the initial failure of the Mark III CS plate by investigating failure locations and loads.

  • PDF

A study of feasibility of using compressed wood for LNG cargo containment system (압축목재를 사용한 LNG 화물창 단열시스템의 적합성 평가에 관한 연구)

  • Kim, Jong-Hwan;Ryu, Dong-Man;Park, Seong-Bo;Noh, Byeong-Jae;Lee, Jae-Myung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제40권4호
    • /
    • pp.307-313
    • /
    • 2016
  • When liquefied natural gas (LNG) is stored in a tank, it is necessary to maintain low temperature. It is very important that insulation techniques are applied to the LNG cargo because of this extreme environment. Hence, laminated wood, especially plywood, is widely used as the structural member and insulation material in LNG cargo containment systems (CCS). However, fracture of plywood has been reported recently, owing to sloshing effect. Therefore, it is necessary to increase the strength of the structural member for solving the problem. In this study, compressed wood, which is used as a support in LNG independent type B tanks, was considered as a substitute for plywood. Compression and bending tests were performed on compressed wood under ambient and cryogenic temperatures to estimate the mechanical behaviors and fracture characteristics. In addition, the direction normal to the laminates surface was considered as an experimental variable. Finally, the feasibility of using compressed wood for an LNG CCS was evaluated from the test results.

An Effect of Surface Dashpot for KC-1 Basic Insulation System Under Sloshing Loads (슬로싱 하중을 받는 KC-1 단열시스템의 표면 완충 효과)

  • Jin, Kyo Kook;Yoon, Ihn Soo;Yang, Young Chul
    • Transactions of the KSME C: Technology and Education
    • /
    • 제3권3호
    • /
    • pp.193-199
    • /
    • 2015
  • Sloshing of LNG cargo can cause high impact loads on the supporting and containing structures. This is particularly critical for membrane-type tanks since these will have flat surfaces and corner regions which can lead to increased peak pressures for sloshing impacts. The membrane-type containment system is much more flexible compared to the steel hull structure. As a result, fluid-structure interaction plays an important role in the structural analysis of the containment system under sloshing load. This study is based on the direct calculation method of applying sloshing loads to the KC-1 basic insulation system using finite element analysis. The structural analysis of KC-1 basic insulation system considers the dashpot as fluid-structure interaction between liquid cargo and the LNG containment system. The maximum stress of the polyurethane form for KC-1 insulation system is 1.5 times lower than one without dashpot.

Local Zooming Analysis of LNGC CCS under Sloshing Impact Loading (LNG선 단열시스템의 슬로싱 충격하중에서의 국부확대해석)

  • Lee, Sang-Gab;Hong, Anh;Cho, Heon-Il;Kim, Jin-Kyung;Ahn, Ji-Woong
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 한국전산구조공학회 2011년도 정기 학술대회
    • /
    • pp.544-551
    • /
    • 2011
  • As the cargo tank size and configuration of Liquefied Natural Gas carriers(LNGC) grows in response to the global increase in demands for LNG and the necessities of its economical transportation, impact loading from sloshing may become one of the most important factors in the structural safety of LNG Cargo Containment Systems(CCS). The objective of this study is to demonstrate the procedure of the structural safety assessment of MARK III membrane type CCS under sloshing impact loading using local zooming analysis technique of LS-DYNA code.

  • PDF

Experimental Study of Sloshing Load on LNG Tanks for Unrestricted Filling Operation

  • Kim, Sang-Yeob;Kim, Yonghwan;Park, Jong-Jin;Kim, Booki
    • Journal of Advanced Research in Ocean Engineering
    • /
    • 제3권1호
    • /
    • pp.41-52
    • /
    • 2017
  • This paper presents a numerical and experimental study of sloshing loads on liquefied natural gas (LNG) vessels. Conventional LNG carriers with membrane-type cargo systems have filling restrictions from 10% to 70% of tank height. The main reason for such restrictions is high sloshing loads around these filling depths. However, intermediate filling depths cannot be avoided for most LNG vessels except the LNG carrier. This study attempted to design a membrane-type LNG tank with a modified lower-chamfer shape that allows all filling operations. First, numerical sloshing analysis was carried out to find an efficient height of the lower-chamfer that can reduce sloshing pressure at partially filled conditions. The numerical sloshing analysis program SHI-SLOSH was used for numerical simulation; this program is based on SOLA-VOF. The effectiveness of the newly designed tanks was validated by 1:50-scale three-dimensional tank tests. A total of three different tanks were tested: a conventional tank and two modified tanks. As test conditions, various filling depths and wave periods were considered, and the same test conditions were applied to the three tanks. During the test, slosh-induced dynamic pressures were measured around the corners of the tank wall. The measured pressure data were post-processed and the pressures of the three different tanks were statistically compared in several ways. Experimental results show that the modified tanks were quite effective in reducing sloshing loads at low filling conditions. This study demonstrated the possibility of all filling operations for LNG cargo containment systems.

Thermal analysis of two main CCS(cargo containment system) insultaion box by using experimental thermal properties (실험적 열적 물성치를 반영한 CCS 방열박스의 열전달 해석)

  • Choi, Sung-Woong;Roh, Jeong-U;Kim, Moo-Sun;Lee, Woo-Il
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • 제24권4호
    • /
    • pp.429-438
    • /
    • 2011
  • In this paper, experiment of thermal conductivity among thermal properties for CCS insulation material was carried out under the condition ranged from room temperature to cryogenic temperature. CCS insulation system should be sustained under cryogenic temperature($-163^{\circ}C$), and lots of investigations will be conducted how to block the heat to insulation material. CCS components which consist of various materials are especially the main interests, and how the temperature of the entire CCS along the location is should be investigated through these studies. With the experimental thermal properties, the steady state thermal analysis of the entire cargo system was conducted. When the LNG leaked through the insulation system with external impact, temperature distribution and thermal safety of secondary barrier, especially plywood and hull structure, was observed.