• Title/Summary/Keyword: LNG 저장탱크

Search Result 217, Processing Time 0.022 seconds

Study on the Brittle Crack Arrest Property for 9% Ni Steel by Duplex ESSO test (Duplex ESSO 시험법에 의한 9% Ni강 취성 균열정지 특성 연구)

  • Kim, Young Kyun;Oh, Byung Taek;Yang, Young Chul;Yoon, Ihn soo;Kim, Jae Hoon
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.6
    • /
    • pp.47-54
    • /
    • 2020
  • A brittle fracture is one of the source of structural damage and can bring a fatal accident. The inner shell of LNG storage tank should be designed and applied to construction by ensure that no brittle crack will occur under -162℃ condition. In point of view of fracture mechanics brittle fracture in the structure could be referred as crack initiation and crack arrest. It should be designed no crack initiation. However, in the unlikely event of a brittle fracture occurring, a back-up function of arresting the brittle crack should be included for the design. In this paper investigated the characteristics of 9% Ni steel thick plates of having a capability of arresting brittle cracks under the thickness of 33 mm, 37mm, 40 mm. First, charpy test has performed to evaluate the fundamental brittle impact fracture property of 9% Ni steel under the temperature of 24℃, -162℃ and -196℃. In addition, Duplex ESSO tests were also performed under -196℃ to evaluate the capability of crack arrest for 9% Ni steel. From the experiments results, it was confirmed that all the thickness of 9% Ni steel plates exhibits sufficient brittle crack arrest fracture toughness for the application of LNG storage tank as a inner shell.

The Measurement of Membrane Deformation Behavior in Kogas Pilot LNG Storage Tank by the use of Mechanical/Electrical Sensor (II) (기계적/전기적 측정 센서를 이용한 Kogas Pilot LNG 저장탱크 멤브레인 변형 거동 측정(II))

  • Kim Y.K.;Hong S.H.;Oh B.T.;Yoon I.S.;Kim J.H.;Kim S.S.
    • 한국가스학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.85-90
    • /
    • 2003
  • Korea Gas Corp. has developed the design technology of the LNG storage tank. The membrane to be applied inside of LNG storage tank is provided with corrugations to absorb thermal contraction and expansion caused by LNG temperature. We constructed strain measurement system by using strain gage. In this paper, some problems which should be considered when measuring strain at $-162^{\circ}C$, are discussed by presenting test results on the characteristics of strain gages, Temperature sensor, adhesive and lead wire. And presenting the procedure of the constructing strain measurement system.

  • PDF

Design Safety Analysis of $9\%$ Nickel Steel Structure in Inner Tank Storage System (내부탱크 저장 시스템에서 $9\%$ 니켈강재 구조물의 설계 안전성에 관한 연구)

  • Kim Chung Kyun;Choi Dong Yul
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.4 s.16
    • /
    • pp.49-55
    • /
    • 2001
  • This paper presents the design safety analysis of the inner tank structure, which is manufactured by 9 percent nickel steel sheets in the full containment type LNG storage tank. The FEM computed results indicate that top girder and several stiffener rings of the inner tank play an important role for controlling the deformation and stress intensity of the inner tank structure. The hydrostatic pressure due to cryogenic fluids gave more influential to the deformation of the inner tank wall compared with that of a cryogenic temperature of $-162^{\circ}C$. But, the deformation and stress of the inner tank. which is produced by the buckling loads, are very small because the external load is not applied to the top of the inner tank. This indicates the role of top girder and stiffener rings of the inner tank model is not important in full containment LNG storage tank.

  • PDF

인터뷰-한국LP가스공업협회 권순영 전무

  • Korea LPGas Industry Association
    • LP가스
    • /
    • s.103
    • /
    • pp.4-5
    • /
    • 2006
  • 정부는 영세서민들의 연료인 프로판에 부과되는 특소세를 폐지하고, 소형저장탱크의 원활한 보급을 위한 법적 기준 완화, LPG와 LNG간 균형적인 정책 추진 등을 통해 사업을 뒷받침해야 할 것이다.

  • PDF

Study on the Fire Safety Estimation for a Pilot LNG Storage Tank (PILOT LNG저장탱크의 화재안전성 평가에 관한 연구)

  • 고재선;김효
    • Fire Science and Engineering
    • /
    • v.18 no.3
    • /
    • pp.57-73
    • /
    • 2004
  • Quantitative safety analysis through a fault tree method has been conducted for a fire broken out over the spilling LNG from a pilot LNG tank, which may have 4 types of scenarios causing potentially risky results. When we consider LNG release from venting pipelines as a first event, any specific radius of Low Flammable Limit(LFL) has not been built up. The second case of LNG outflow from the rupture of storage tank which will be the severest has been analyzed and the results revealed various diffusion areas to the leaking times even with the same amount of LNG release. As a third case LNG leakage from the inlet/outlet pipelines was taken into consider. The results showed no significant differences of LFL radii between the two spilling times of 10 and 60 minutes. Hence, we have known the most affecting factor on the third scenario is an initial amount of LNG release. Finally, the extent of LFL was calculated when LNG pipelines around the dike area were damaged. In addition, consequence analysis has been also performed to acquire the heat radiation and flame magnitude for each case.

An Advanced Design Procedure for Dome and Ring Beam of Concrete Containment Structures (콘크리트 격납구조물 돔과 링빔의 개선된 설계기법)

  • Jeon, Se-Jin;Kim, Young-Jin
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.6
    • /
    • pp.817-824
    • /
    • 2010
  • The concrete containment structures have been widely used in nuclear power plants, LNG storage tanks, etc., due to their high safety and economic efficiency. The containment structure consists of a bottom slab, wall, ring beam and dome. The shape of the roof dome has a very significant effect on structural safety, the quantity of materials, and constructability; the thickness and curvature of the dome should therefore be determined to give the optimum design. The ring beam plays the role as supports for the dome, resulting in a minimized deformation of the wall. The main issues in designing the ring beam are the correct dimensions of the section and the prestress level. In this study, an efficient design procedure is proposed that can be used to determine an optimal shape and prestress level of the dome and ring beam. In the preliminary design stage of the procedure, the membrane theory of shells of revolution is adopted to determine several plausible alternatives which can be obtained even by hand calculation. Based on the proposed procedures, domes and ring beams of the existing domestic containment structures are analyzed and some improvements are discussed.

A Study on the Characteristics of the Work Safety Environment Sensing Module for LNG Storage Tanks (LNG 저장탱크용 작업안전 환경 센싱 모듈의 특성연구)

  • Park, Byong Jin;Kim, Min Sung
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.2
    • /
    • pp.189-196
    • /
    • 2022
  • We have developed an embedded based environment sensing module with high-resolution temperature, humidity and gas sensors to detect gas leakage under the condition of LNG injection. The developed sensing module have linearity with gas concentration. We have confirmed the developed sensing module could detect LNG gas concentration of 5 cmol/mol and 15 cmol/mol, which are gas concentration at risk of explosion. The response time of the developed module was fast within 8 seconds. Therefore it can be used to detect LNG gas leakage.