• Title/Summary/Keyword: LLD

Search Result 47, Processing Time 0.029 seconds

The Reconstruction with Extracorporeal Irradiated Autograft for Osteosarcoma of Extremities (사지 골육종에서 체외 방사선 조사를 이용한 재건술)

  • Kim, Jae-Do;Lee, Gun-Woo;Chung, So-Hak
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.16 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • Purpose: With advances in various treatment modalities, limb salvage surgery has been commonly used in osteosarcoma of extremities. An alternative method for skeletal reconstruction is reimplantation of the tumor bearing bone following extracorporeal irradiation (ECI). We report the long-term results of ECI autograft in aspect of the oncological and functional outcomes, and complications. Materials and Methods: We retrospectively reviewed 31 osteosarcoma patients who underwent reconstruction with ECI between July 1995 and January 2006. There were 24 males and 7 females with a mean age of 24 (7-74 years) and a mean follow-up of 117 months (17-177 months). Twenty-five cases were reconstructed with ECI autograft, 6 cases with ECI autograft-prosthesis composite. The pathologic subtypes were conventional in 29 cases, periosteal in 1 case, and parosteal in 1 case. The most common location of tumor was distal femur (15 cases) followed by humerus (3), proximal fibula (3) and proximal tibia (3). Musculoskeletal Tumor Society (MSTS) score was used for functional evaluation. The overall survival rate, local recurrence, complications were analyzed. Results: The overall survival rate was 80.6% and the disease-free survival rate was 64.5%. Five patients died of distant metastasis. One patient required above-knee amputation due to local recurrence. All of them, twenty-three complications occurred, which included nonunion in 7 cases, deep infection in 5 cases, joint instability in 4 cases, metal failure in 2 cases, Limb-length discrepancy (LLD) in 2 cases, periprosthetic fracture in 1 case, epiphyseal collapse in 1, local recurrence in 1 case. The mean MSTS functional score was 62.5%. Conclusion: Extracorporeal irradiated autograft can be achieved relatively good result in aspect of oncological and functional aspect, but is needed to be additional research about occurring many complications. The reconstruction with ECI after intercalary or fragmentary resection is effective reconstruction in aspect of oncological and functional result, complications.

Fractional-N PLL Frequency Synthesizer Design (Fractional-N PLL (Phase-Locked Loop) 주파수 합성기 설계)

  • Kim Sun-Cheo;Won Hee-Seok;Kim Young-Sik
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.7 s.337
    • /
    • pp.35-40
    • /
    • 2005
  • This paper proposes a fractional-N phase-locked loop (PLL) frequency synthesizer using the 3rd order ${\Delta}{\sum}$ modulator for 900MHz medium speed wireless link. The LC voltage-controlled oscillator (VCO) is used for the good phase noise property. To reduce the lock-in time, a charge pump has been developed to control the pumping current according to the frequency steps and the reference frequency is increased up to 3MHz. A 36/37 fractional-N divider is used to increase the reference frequency of the phase frequency detector (PFD) and to reduce the minimum frequency step simultaneously. A 3rd order ${\Delta}{\sum}$ modulator has been developed to reduce the fractional spur VCO, Divider by 8 Prescaler, PFD and Charge pump have been developed with 0.25um CMOS, and the fractional-N divider and the third order ${\Delta}{\sum}$ modulator have been designed with the VHDL code, and they are implemented through the FPGA board of the Xilinx Spartan2E. The measured results show that the output power of the PLL is about -lldBm and the phase noise is -77.75dBc/Hz at 100kHz offset frequency. The minimum frequency step and the maximum lock-in time are 10kHz and around 800us for the maximum frequency change of 10MHz, respectively.

The Comparative Study between Leg Length Analysis and X-ray on Diagnosis of Pelvic Malpositions - according to Positions and Valuation Bases - (기능성 족지장단분석과 X-ray의 골반변위 진단의 비교 연구 - X-ray 촬영 자세 및 평가 기준에 따라 -)

  • Lee, Jung-Min;Koog, Gil-Ho;Choi, Bo-Mi;Jeong, Hyun-A;Hong, Seo-Young
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.5 no.2
    • /
    • pp.169-180
    • /
    • 2010
  • Objectives: This study was carried out to investigate the relationship of leg length analysis and X-ray finding according to positions and valuation bases on diagnosis of pelvic malpositions. Methods: Twenty-two people who get $33.09{\pm}10.73$ as average were evaluated by leg length analysis and X-ray findings. After measuring innominate measurement(IM), femur head line. distance between S2 and posterior superior iliac spine(PSIS). ilium shadow measurement(ISM), major axis of obturator foramen(MaF), minor axis of obturator foramen(MiF) and distance between off centering measurement and symphysis pubis, those were analyzed. Results: 1. In assessment of posterior rotation malposition ilium(PI), it was showed the best coincidence between leg length analysis and X-ray analyzed by 1M in supine position(11 cases, 50.5%). 2. In assessment of inflare, coincidence index between leg length analysis and X-ray were not good($4.00{\pm}3.03$ cases, $18.15{\pm}13.82%$). And leg length analysis were not sensitive. 3. On the whole, coincidence index between leg length analysis and X-ray were not good(best: 1 case, 45.5%; worst: 11 cases, 50.0%). Conclusions: Results form this investigation showed the relationship of leg length analysis and X-ray according 10 positions and valuation bases on diagnosis of pelvic malpositions. This results are expected to contribute to establish method of assessment in diagnosis of pelvic malpositions.

  • PDF

A Study on Recent Trends in Building Linked Data for Overseas Libraries: Focusing on Published Datasets, Reused Vocabulary, and Interlinked External Datasets (해외 도서관 링크드 데이터 구축의 최근 동향 연구 - 발행 데이터세트, 재사용 어휘집, 인터링킹 외부 데이터세트를 중심으로 -)

  • Sung-Sook Lee
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.56 no.4
    • /
    • pp.5-28
    • /
    • 2022
  • In this study, LD construction cases of overseas libraries were analyzed with focus on published datasets, reused vocabulary, and interlinked external datasets, and based on the analysis results, basic data on LD construction plans of domestic libraries were obtained. As a result of the analysis of 21 library cases, overseas libraries have established a faithful authority LD and conducted new services using published LDs. To this end, overseas libraries collaborated with other libraries and cultural institutions within the region, within the country, and nationally under the leadership of the library, and based on this cooperation, a specialized dataset was published. Overseas libraries used Schema.org to increase the visibility of published LDs, and used BIBFRAME for subdivision of description to define various entities and build LDs based on the defined entities. Overseas libraries have utilized various defined entities to link related information, display results, browse, and download in bulk. Overseas libraries were interested in the continuous up-to-date of interlinked external datasets, and directly utilized external data to reinforce catalog information. In this study, based on the derived implications, points to be considered when issuing LDs by domestic libraries were proposed. The research results can be used as basic data when future domestic libraries plan LD services or upgrade existing services.

Effect of temperature and relative humidity in refrigerator on quality traits and storage characteristics of Pre-packed Hanwoo loin (냉장고 내 온도와 상대습도가 포장 한우 등심의 품질 및 저장 특성에 미치는 영향)

  • Seol, Kuk-Hwan;Kim, Ki Hyun;Kim, Young Hwa;Youm, Kyung Eun;Lee, Mooha
    • Korean Journal of Agricultural Science
    • /
    • v.41 no.4
    • /
    • pp.415-424
    • /
    • 2014
  • This study was carried out to determine the effect of storage condition, such as temperature or relative humidity (RH) in home-style refrigerator, on the change of quality traits and storage characteristics of Hanwoo M. longissimus to find out the condition for prolongation of shelf-life with maintaining the meat quality for consumers. Samples were sliced in $1{\pm}0.2cm$ thickness, and packed in foamed polystyrene tray with linear low-density polyethylene (LLD-PE) film to simulate the pre-packed Hanwoo loin sold in retail market, then stored in home-style refrigerator ($5^{\circ}C$/17% RH, Control), and chambers of $5^{\circ}C$/55% RH (T1), $5^{\circ}C$/85% RH (T2), and $-1^{\circ}C$/99% RH (T3), respectively. Quality traits (color, pH, water holding capacity, shear force and grilling loss) and storage characteristics (thiobarbituric acid reactive substances, volatile basic nitrogen and total microbes) were measured at 1, 4, 7, 14 and 21 days after storage. Lightness of Hanwoo loin stored in T1, T2 and T3 were higher than that of control until 14 days of storage, however at the end of storage (21 days) control showed significantly higher than other treatments (p<0.05). Redness and Yellowness of Hanwoo loin samples stored in T1 and T3 were significantly higher than others during all storage period (p<0.05). The water holding capacity (WHC) of control was significantly higher than others until 14 days of storage (p<0.05), however, Hanwoo loin stored in T2 was the highest ($63.64{\pm}7.62kg/cm^2$) at 21 days of storage. Hanwoo loin stored in T1 showed significantly lower shear force than others during all storage period (p<0.05). There was no consistent tendency in pH and grilling loss during storage in all treatments. Hanwoo loin stored in T1 showed lower TBARS value than others during storage period, however there was a rapid increase to $0.34{\pm}0.27mg$ malonaldehyde/kg meat at 21 days of storage. And, all the treated samples (from T1 to T3) showed significantly lower VBN values at 21 days of storage (p<0.05). The population of total aerobic microbes were significantly increased in all treatments as storage period increasing, and the population of T3 ($2.28{\pm}0.57logCFU/g$) was the lowest at 21 days of storage (p<0.05). From those results, it could be predicted the better storage condition to maintain the meat quality and prolong the shelf-life of Hanwoo loin by lowering the temperature and adjusting the humidity about 55%.

Effect of storage condition on sensory properties and fatty acid composition of pre-packed Hanwoo loin (저장조건이 포장 한우 등심의 관능적 특성 및 지방산 조성에 미치는 영향)

  • Seol, Kuk-Hwan;Kim, Ki Hyun;Kim, Young Hwa;Youm, Kyung Eun;Lee, Mooha
    • Korean Journal of Agricultural Science
    • /
    • v.42 no.1
    • /
    • pp.37-46
    • /
    • 2015
  • This study was carried out to determine the effect of storage condition, such as temperature and relative humidity (RH), on the change of sensory properties and free fatty acid composition of pre-packed Hanwoo loin (Musculus longissimus) until $21^{st}$ day of storage. The Hanwoo loin was sliced in $1.0{\pm}0.2cm$ thickness and each of the sliced pieces was packed in a foamed polystyrene tray with linear low-density polyethylene (LLD-PE) film to simulate the pre-packed Hanwoo loin sold in retail market, then stored in home-style refrigerator (Con; $5^{\circ}C$, 17%RH), and temperature and RH controled chambers (T1; $5^{\circ}C$, 55%RH, T2; $5^{\circ}C$, 85%RH, and T3; $-1^{\circ}C$, 99%RH), respectively. The sensory characteristics of pre-packed Hanwoo loin during storage in different conditions were measured on raw or after cooking. After 21 days of storage, the loin stored in T3 showed significantly high color and acceptability scores ($7.46{\pm}1.07$, $7.06{\pm}1.36$, respectively) on raw loin, and flavor and acceptability scores ($7.16{\pm}0.90$, $6.90{\pm}0.92$, respectively) on cooked loin than those of others (p<0.05). The concentration of 12 fatty acids of pre-packed Hanwoo loin during storage in different conditions were analysed. The concentration of oleic acid (C18:1, $39.92{\pm}3.22%$), palmitic acid (C16:0, $28.20{\pm}2.42%$), and stearic acid (C18:0, $12.59{\pm}2.79%$) was high in Hanwoo loin on $1^{st}$ day of storage. The concentration of palmitic acid of Hanwoo loin stored in T2 was increased significantly after $4^{th}$ day of storage (p<0.05), and the concentration of myristic acid(C14:0) of Hanwoo loin stored in treated chamber (T1 to T3) was significantly higher than Con after $14^{th}$ day of storage (p<0.05). The concentration of linolenic acid (C18:3) of Hanwoo loin was decreased significantly after $4^{th}$ day of storage in all tested storage conditions (p<0.05). However, there was no significant or consistent change in the concentration of oleic acid (C18:1) during storage period in every Hanwoo loin stored in tested conditions. Although, the concentration of total monounsaturated fatty acids (MUFA) was decreased in Con and T2 (p<0.05), there was no consistent change in the monounsaturated fatty acids to saturated fatty acids ratio (MUFA/SFA) during storage period (p>0.05). From those results, it was considered that storage condition affects on the sensory acceptability and fatty acid composition of pre-packed Hanwoo loin as storage period was increased.

EVALUATION OF CONDYLAR POSITION USING COMPUTED TOMOGRAPH FOLLOWING BILATERAL SAGITTAL SPLIT RAMUS OSTEOTOMY (전산화단층촬영법을 이용한 하악 전돌증 환자의 하악지 시상 골절단술후 하악과두 위치변화 분석)

  • Chol, Kang-Young;Lee, Sang-Han
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.18 no.4
    • /
    • pp.570-593
    • /
    • 1996
  • This study was intended to perform the influence of condyle positional change after surgical correction of skeletal Class III malocclusion after BSSRO in 20 patients(males 9, females 11) using computed tomogram that were taken in centric occlusion before, immediate, and long term after surgery and lateral cephalogram that were taken in centric occlusion before, 7 days within the period intermaxillary fixation, 24hour after removing intermaxillary fixation and long term after surgery. 1. Mean intercondylar distance was $84.45{\pm}4.01mm$ and horizontal long axis of condylar angle was $11.89{\pm}5.19^{\circ}$on right, $11.65{\pm}2.09^{\circ}$on left side and condylar lateral poles were located about 12mm and medial poles about 7mm from reference line(AA') on the axial tomograph. Mean intercondylar distance was $84.43{\pm}3.96mm$ and vertical axis angle of condylar angle was $78.72{\pm}3.43^{\circ}$on right, $78.09{\pm}6.12^{\circ}$on left. 2. No statistical significance was found on the condylar change(T2C-T1C) but it had definitive increasing tendency. There was significant decreasing of the distance between both condylar pole and the AA'(p<0.05) during the long term(TLC-T2C). 3. On the lateral cephalogram, no statistical significance was found between immediate after surgery and 24 hours after the removing of intermaxillary fixation but only the lower incisor tip moved forward about 0.33mm(p<0.05). Considering individual relapse rate, mean relapse rate was 1.2% on L1, 5.0% on B, 2.0% on Pog, 9.1% on Gn, 10.3% on Me(p<0.05). 4. There was statistical significance on the influence of the mandibular set-back to the total mandibular relapse(p<0.05). 5. There was no statistical significance on the influence of the mandibular set-back(T2-T1) to the condylar change(T2C-T1C), the condylar change(T2C-T1C, TLC-T2C) to the mandibular total relapse, the pre-operative condylar position to the condylar change(T2C-T1C, TLC-T2C), the pre-operative mandibular posture to the condylar change(T2C-T1C, TLC-T2C)(p>0.05). 6. The result of multiple regression analysis on the influence of the pre-operative condylar position to the total mandibular relapse revealed that the more increasing of intercondylar distance and condylar vertical axis angle and decreasing of condyalr head long axis angle, the more increasing of mandibular horizontal relapse(L1,B,Pog,Gn,Me) on the right side condyle. The same result was founded in the case of horizontal relapse(L1,Me) on the left side condyle.(p<0.05). 7. The result of multiple regression analysis on the influence of the pre-operative condylar position to the pre-operative mandibular posture revealed that the more increasing of intercondylar distance and condylar vertical axis angle and decreasing of condylar head long axis angle, the more increasing of mandibular vertical length on the right side condyle. and increasing of vertical lengh & prognathism on the left side condyle(p<0.05). 8. The result of simple regression analysis on the influence of the pre-operative mandibular posture to the mandibular total relapse revealed that the more increasing of prognathism, the more increasing of mandibular total relapse in B and the more increasing of over-jet the more increasing of mandibular total relapse(p<0.05). Consequently, surgical mandibular repositioning was not significantly influenced to the change of condylar position with condylar reposition method.

  • PDF