• 제목/요약/키워드: LLCL filters

검색결과 6건 처리시간 0.021초

Design of LLCL Filter for Single Phase Inverters with Confined Band Variable Switching Frequency (CB-VSF) PWM

  • Attia, Hussain A.;Freddy, Tan Kheng Suan;Che, Hang Seng;El Khateb, Ahmad H.
    • Journal of Power Electronics
    • /
    • 제19권1호
    • /
    • pp.44-57
    • /
    • 2019
  • Recently, the use of LLCL filters for grid inverters has been suggested to give better harmonic attenuation than the commonly used L and LCL filters, particularly around the switching frequency. Nevertheless, this filter is mainly designed for constant switching frequency pulse width modulation (CSF PWM) methods. In variable switching frequency PWM (VSF PWM), the harmonic components are distributed across a wide frequency band which complicates the use of a high order filter, including LCL and LLCL filters. Recently, a confined band variable switching frequency (CB-VSF) PWM method has been proposed and demonstrated to be superior to the conventional constant switching frequency (CSF) PWM in terms of switching losses. However, the applicability of LLCL filters for this type of CB-VSF PWM has not been discussed. In this paper, the authors study the suitability of an LLCL filter for CB-VSF PWM and propose design guidelines for the filter parameters. Using simulation and experimental results, it is demonstrated that the effectiveness of an LLCL filter with CB-VSF PWM depends on the parameters of the filters as well as the designed variable frequency band of the PWM. Simulation results confirm the performance of the suggested LLCL design, which is further validated using a lab scale prototype.

LLCL 입력필터를 갖는 단상 그리드 컨버터의 가상 저항에 따른 전류제어 안정도 해석 (Stability Analysis of Current Control based on Virtual Resistor for Single-Phase Grid Converters with LLCL Input Filters)

  • 배철주;이동춘
    • 전력전자학회논문지
    • /
    • 제21권5호
    • /
    • pp.404-410
    • /
    • 2016
  • To avoid the stability issues of LLCL filters, passive or active damping methods to eliminate the resonance phenomena are required. In this paper, system stability of a current control is analyzed when the active damping scheme based on the virtual resister is utilized in single-phase grid converter systems with LLCL input filters. The control performance according to the parameters of the virtual resistance is investigated. The validity of stability analysis was verified by simulation and experimental results.

LLCL 입력필터를 갖는 단상 그리드 컨버터의 전류제어 안정도 해석 (Stability Analysis of Current Control for Single-Phase Grid Converters with LLCL Input Filters)

  • 배철주;이동춘
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.514-515
    • /
    • 2015
  • 본 논문은 LLCL 입력필터를 적용한 단상 그리드 컨버터에서 필터의 공진 감쇠를 위한 가상저항 기반의 능동 감쇠 기법을 이용한 전류제어 시스템의 안정도를 분석한다. LLCL 필터의 가상저항 값에 따른 안정도를 조사하고 PSIM 시뮬레이션을 통해 비교 분석한다.

  • PDF

Active Damping of LLCL Filters Using PR Control for Grid-Connected Three-Level T-Type Converters

  • Alemi, Payam;Jeong, Seon-Yeong;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • 제15권3호
    • /
    • pp.786-795
    • /
    • 2015
  • In this paper, an active damping control scheme for LLCL filters based on the PR (proportional-resonant) regulator is proposed for grid-connected three-level T-type PWM converter systems. The PR controller gives an infinite gain at the resonance frequency. As a result, the oscillation can be suppressed at that frequency. In order to improve the stability of the system in the case of grid impedance variations, online grid impedance estimation is applied. Simulation and experimental results have verified the effectiveness of the proposed scheme for three-phase T-type AC/DC PWM converters.

Comparative Analysis of LCL and LLCL Filters for Three-level PWM Converters

  • Alemi, Payam;Le, Quoc Anh;Lee, Dong-Choon
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.283-284
    • /
    • 2014
  • In this paper, a comparative analysis of LCL and LLCL filters connected to three-level T-type PWM converters is presented, in which the filter inductor sizes are investigated in view of total harmonic distortion (THD) in grid phase currents. The analysis results are verified by simulation and experiments.

  • PDF

엘리베이터 회생용 인버터의 고조파 전류저감을 위한 LLCL 필터와 LCL 필터의 성능 비교 (A Performance Comparison between LLCL and LCL filters to Reduce Harmonic Current of Regeneration Power Inverter for Elevator)

  • 안병웅;진용신;김학원;조관열;임병국;신희근;이용규
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.264-266
    • /
    • 2012
  • 엘리베이터 제동 시 발생하는 인버터 회생 전류는 많은 고조파를 포함하고 있다. 기존의 회생용 인버터는 계통 측 필터로 L필터가 많이 사용되어 왔으나, 고조파를 저감하기 위해서 매우 큰 L값을 요구한다. 하지만 엘리베이터 회생용 인버터는 기설치된 DC Link 과전압 방지 방전회로가 동작되기 전에 회생을 실시하여야 하므로, 상대적으로 낮은 전압에서 회생되어야 하므로 큰 임피던스를 갖는 L필터를 사용하기 어렵다. 본 논문에서는 엘리베이터 회생용 인버터의 리플저감용 LCL 필터와 최근 제안된 LLCL 필터의 성능을 비교 분석하고 모의해석과 실험을 통해 그 타당성을 입증 하였다.

  • PDF