• Title/Summary/Keyword: LF(Low Frequency)

Search Result 165, Processing Time 0.023 seconds

Analysis of Dynamic Positioning System Based on Self-Tuning Control (자기동조 제어기를 이용한 위치확보 시스템에 관한 연구)

  • Sang-M.,Lee;Pan-M.,Lee;Sa-Y.,Hong
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.26 no.2
    • /
    • pp.32-40
    • /
    • 1989
  • Dynamic ship positioning(DP) system is used to keep the position and heading of a ship, or a floating platform, above a pre-selected site on the seabed by using thrusters. This paper presents a control system based on filtering technique and optimal control theory. The planar motions of a vessel are assumed to consist of low frequency(LF) component and high frequency(HF) one. The former is mainly due to thrusters, current, wind and second order wave forces, while the latter is mainly due to first order oscillatory component of the wave force. Furthermore position measurement signals include the noise. By means of self-tuning filter and Kalman filter techniques, LF motion estimates and HF ones are seperately achieved from the position measurements of the vessel. The estimated LF motions are used as input to the feedback loops. The total thruster power is minimized using the Linear Quadratic Gaussian control theory. The performance of the vessel with the DP system is investigated by computer simulation.

  • PDF

Characteristics of Digital Infrared Thermal Imaging and Quantitative Evaluations for Patients with Burning Mouth Syndrome: a Cross Sectional Study (구강작열감증후군 환자의 적외선체열검사와 정량적 평가 특성 : 단면조사연구)

  • Ko, Whee-hyoung;Nam, Seong-uk;Ha, Na-yeon;Hwang, Mi-ni;Baek, So-young;Kim, Dong-yoon;Kim, Jin-sung
    • The Journal of Internal Korean Medicine
    • /
    • v.39 no.4
    • /
    • pp.699-707
    • /
    • 2018
  • Objectives: This study was designed to investigate characteristics of digital infrared thermal imaging (DITI) and quantitative evaluations in patients with burning mouth syndrome (BMS). Methods: We reviewed the clinical records of 38 patients with BMS who visited the Oral Diseases Clinic of Kyung Hee University Korean Medicine Hospital from March 1st, 2018 to June 30th, 2018. The subjects were evaluated with digital infrared thermal imaging (DITI) and for heart rate variability (HRV), unstimulated salivary flow rate (USFR), and the proportion of coated tongue. Results: Most patients showed higher temperatures on the central part of the tongue (T2) than on the middle of the forehead (T1). The patients tended to have a high Low frequency/High frequency (LF/HF) ratio. Statistically significant negative correlations were noted between the age of patients and the temperature of T1 and T2. Statistically significant negative correlations were also observed between the LF/HF ratio and 'T1-T2' values. Conclusions: This study suggests that DITI and HRV are useful for the validation of patients with BMS. Correlations between the result values suggest that sympathetic function acceleration is related to temperature distribution and, ultimately, to symptoms.

Effects of Combined Stimulus on Stress Relief (지압과 온열의 조합마사지가 인체의 스트레스 완화에 미치는 영향 평가)

  • Lee, Dae Won;Park, Ji Hyung;Eom, Si Nae;Kim, Do Won;Cho, Syung Hyun;Ko, Chang-Yong;Kim, Han Sung
    • Journal of Biomedical Engineering Research
    • /
    • v.33 no.4
    • /
    • pp.194-201
    • /
    • 2012
  • This study was designed to investigate the effect of a combined stimulus which was composed of chiropractic massage and thermotherapy on the relief of mental and physical stress. Fifteen healthy male subjects were treated with three type of stimuli; control (without any stimulus), a single stimulus (only chiropractic) and a combined stimulus. To evaluate the effects of stimuli, visual analogue scale (VAS), trunk extension, electromyogram (EMG) on erector spinae muscle and electrocardiogram (ECG) were measured and analyzed before and after stimuli. In the control group, there were no significant changes in EMG root mean square (RMS) value and low Frequency/high Frequency (LF/HF) ratio (p > 0.05, p > 0.05). However, both stimulus groups showed significant increases in trunk extension and EMG RMS values (p < 0.05, p < 0.05), but significant decreases in LF/HF ratios (p < 0.05). Particularly the decrement rate in LF/HF ratio was significantly higher in the combined stimulus group than that in the single stimulus group (p < 0.05). Also, a significantly lower VAS was recorded after combined stimulus. Our findings indicate that the combined stimulus might not only improve flexibility and strength of muscle, but also active parasympathetic nerve activity. The combined stimulus may thus contribute to relieve the stress and to enhance the muscle function.

A Study on the Effects of Chinese Qigong and Kundalini Yoga Meditations on the Heart Rate Variability of Skilled Students (중국 기공 및 쿤달리니 요가 명상이 숙련자의 심박변이율(HRV) 변화에 미치는 영향에 관한 연구)

  • Jang, Dae-Geun;Jang, Jae-Keun;Park, Seung-Hun;Hahn, Minsoo
    • Journal of Biomedical Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.141-147
    • /
    • 2012
  • In this paper, we have investigated effects of two specific meditations (Chinese qigong meditation and Kundalini yoga meditation) on the heart rate variability (HRV), which is a well-known quantitative measure of autonomic balance, of skilled students. To analyze the effects, the MIT/BIH physionet database was utilized. The database includes RR intervals of eight skilled Chinese qigong meditators (5 women and 3 men; age range 26-35) and four skilled Kundalini yoga meditators (2 women and 2 men; age range 20-52). RR intervals of each subject were measured before and during the meditations. For HRV analysis, we have used typical four HRV parameters - the low frequency to high frequency power ratio (LF/HF ratio), SD2/SD1 ratio, sample entropy, and fractal dimension. The LF/HF ratio was calculated by the autoregressive spectrum and the SD2/SD1 ratio was derived from the Poincar$\grave{e}$ plot. The sample entropy was computed from the phase space plot and the fractal dimension was estimated by the Higuchi's algorithm. In the experiments, the Wilcoxon signed rank test was employed because we used small datasets and compared HRV parameters before and during the meditations. As a result, we have found increment of the LF/HF and SD2/SD1 ratios in both meditations; whereas the sample entropy is decreased during the meditations. In addition, the fractal dimension is increased during the Chinese qigong meditation; whereas it is decreased during the Kundalini yoga meditation. The results show that the sympathetic nervous system is generally more activated in skilled Chinese qigong and Kundalini yoga meditators, but the activation of the parasympathetic nervous tone is suppressed.

The Changes of Blood Pressure, Heart Rate and Heart Rate Variability after Stellate Ganglion Block (성상신경절 차단 시 혈압, 맥박수 및 심박수 변이도의 변화)

  • Kweon, Tae Dong;Han, Chung Mi;Kim, So Yeun;Lee, Youn-Woo
    • The Korean Journal of Pain
    • /
    • v.19 no.2
    • /
    • pp.202-206
    • /
    • 2006
  • Background: Stellate ganglion block (SGB) might be associated with changes in the blood pressure (BP) and heart rate (HR). The heart rate variability (HRV) shows the balance state between sympathetic and parasympathetic activities of the heart. The changes in these parameters of the HRV were studied to evaluate the possible mechanism of SGB in changing the BP. Methods: SGB was performed on 26 patients, using a paratracheal technique at the C6 level, and 8 ml of 1% mepivacaine injected. The success was confirmed by check the Horner's syndrome. The BP, HR and HRV were measured before and 5, 15, 30, 45 and 60 minutes after the SGB. Results: The increases in the BP from the baseline throughout the study period were statistically, but not clinically significant. The HR and LF/HF (low frequency/high frequency) ratio were increased at 5 and 45 min, respectively, after the administration of the SGB. In a comparison of left and right SGB, no significant differences were found in the BP, HR and HRV. A correlation analysis showed that an increased BP was significantly related with the changes in the LF/HF ratio and LF at 15 and 30 minutes, respectively, after the SGB. Dividing the patients into two groups; an increased BP greater and less than 20% of that at the baseline INC and NOT groups, respectively, hoarseness occurred more often in the INC group (P = 0.02). Conclusions: It was concluded that SGB itself does not clinically increase the BP and HR in normal hemodynamic patients. However, the loss of balance between the sympathetic and parasympathetic nerve system, attenuation of the baroreceptor reflex and hoarseness are minor causes of the increase in the BP following SGB; therefore, further studies will be required.

A Study on Heart Rate Variability(HRV) of Women with Fibroadenoma (유방 섬유선종이 있는 2, 30대 여성의 HRV 특성 연구)

  • Ahn, Ji-Yoon;Choi, Seok-Young;Lee, Mi-Joo;Lee, Jin-Moo;Jang, Jun-Bock;Lee, Kyung-Sub;Lee, Chang-Hoon
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.25 no.4
    • /
    • pp.56-65
    • /
    • 2012
  • Purpose: This study aims to analyze Heart Rate Variability(HRV) in women with fibroadenoma compared with non-fibroadenoma women. Methods: We studied 82 patients visiting Kang-Nam Kyung-Hee Korean Hospital Medical Examination Center from January, 2010 to November, 2011. The subjects were categorized in two groups, fibroadenoma group(n=16) and non-fibroadenoma group (n=66). We investigated the difference of HRV between two groups. Results: The square root of the mean squared difference of successive NNs (RMSSD) in fibroadenoma group is significantly lower than non-fibroadenoma group. LF/HF ratio in fibroadenoma group is significantly higher than non-fibroadenoma group. There was no significant difference in low frequency(LF) and high frequency (HF). However, normalized LF in fibroadenoma group is significantly higher than non-fibroadenoma group. In addition, normalized HF in fibroadenoma group is significantly lower than non-fibroadenoma group. Conclusions: Fibroadenoma group is related to autonomic nerve imbalances that is assumed by psychological problems.

Autonomic Responses Related to the Floor Plan Configurations of One-room Units: Focus on 10 Types of Floor Plan Configurations (원룸 평면 구성에 따른 자율신경계 반응: 사례조사 기반의 10개 평면 유형을 중심으로)

  • Myung, Jee-Yeon;Kim, Kyu-Beom;Jun, Han-Jong
    • Science of Emotion and Sensibility
    • /
    • v.22 no.2
    • /
    • pp.101-108
    • /
    • 2019
  • The aim of this study was to verify differences in autonomic responses that are affected by the configurations of one-room type units using an electrocardiogram (ECG). Accordingly, 43 one-room units that were collected randomly were classified into ten different types of floor plan configurations mainly according to the location of the bathroom and kitchen. An ECG was subsequently measured for each plan type and the average ratio of the LF/HF (Power in low frequency range/Power in high frequency range) was calculated to measure the comfort level of each space. The results revealed a significant statistical difference between the average LF/HF ratio between the plan types (p < 0.05) and provided compelling evidence suggesting that the configuration of the plan may affect the quality of one-room space. This approach appears to be effective in counteracting stress that may exacerbate psychological disorders in single person households.

The Characteristics of Diamond-like Carbon Films Deposited by Low Frequency(60Hz) Plasma CVD at Room Temperature for Optical lens (광학렌즈를 위한 저주파(60Hz) 플라즈마 CVD로 실온에서 제작한 다이아몬드성 탄소 박막의 특성)

  • Kang, Sung Soo;Lee, Won Jin;Sung, Duk Yong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.1 no.1
    • /
    • pp.23-28
    • /
    • 1996
  • Hydrogenated amorphous carbon films were fabricated by low frequency(60Hz) Plasma enhanced Chemical vapor deposition(LF-PECVD) at room temperature. The LF_PECVD has a couple of advantages as follows: cheap, and the employment of low power density makes the damage of samples small. The a-C:H films deposited in this work were highly transparent(99%), highly resistance(109-1011${\Omega}$-cm), and very uniform. The samples were deposited by the decomposition of CH4 and H2 mixing gas in the pressure rate range of 1% to 30%. The deposition rates, optical gap, and hydrogen contents are increased with CH4 contents.

  • PDF

Relation between heart rate variability and spectral analysis of electroencephalogram in chronic neuropathic pain patients

  • John Rajan;Girwar Singh Gaur;Karthik Shanmugavel;Adinarayanan S
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.28 no.3
    • /
    • pp.253-264
    • /
    • 2024
  • Chronic neuropathic pain (CNP) is a complex condition often arising from neural maladaptation after nerve injury. Understanding CNP complications involves the intricate interplay between brain-heart dynamics, assessed through quantitative electroencephalogram (qEEG) and heart rate variability (HRV). However, insights into their interaction in chronic pain are limited. Resting EEG and simultaneous electrocardiogram (lead II) of the participants were recorded for qEEG and HRV analysis. Correlations between HRV and qEEG parameters were calculated and compared with age, sex, and body mass index (BMI)-matched controls. CNP patients showed reduced HRV and significant increases in qEEG power spectral densities within delta, theta, and beta frequency ranges. A positive correlation was found between low frequency/high frequency (LF/HF) ratio in HRV analysis and theta, alpha, and beta frequency bands in qEEG among CNP patients. However, no significant correlation was observed between parasympathetic indices and theta, beta bands in qEEG within CNP group, unlike age, sex, and BMI-matched healthy controls. CNP patients display significant HRV reductions and distinctive qEEG patterns. While healthy controls exhibit significant correlations between parasympathetic HRV parameters and qEEG spectral densities, these relationships are diminished or absent in CNP individuals. LF/HF ratio, reflecting sympathovagal balance, correlates significantly with qEEG frequency bands (theta, alpha, beta), illuminating autonomic dysregulation in CNP. These findings emphasize the intricate brain-heart interplay in chronic pain, warranting further exploration.

Canonical Correlation of 3D Visual Fatigue between Subjective and Physiological Measures

  • Won, Myeung Ju;Park, Sang In;Whang, Mincheol
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.6
    • /
    • pp.785-791
    • /
    • 2012
  • Objective: The aim of this study was to investigate the correlation between 3D visual fatigue and physiological measures by canonical correlation analysis enabling to categorical correlation. Background: Few studies have been conducted to investigate the physiological mechanism underlying the visual fatigue caused by processing 3D information which may make the cognitive mechanism overloaded. However, even the previous studies lack validation in terms of the correlation between physiological variables and the visual fatigue. Method: 9 Female and 6 male subjects with a mean age of $22.53{\pm}2.55$ voluntarily participated in this experiment. All participants were asked to report how they felt about their health sate at after viewing 3D. In addition, Low & Hybrid measurement test(Event Related Potential, Steady-state Visual Evoked Potential) and for evaluating cognitive fatigue before and after viewing 3D were performed. The physiological signal were measured with subjective fatigue evaluation before and after in watching the 3D content. For this study suggesting categorical correlation, all measures were categorized into three sets such as included Visual Fatigue set(response time, subjective evaluation), Autonomic Nervous System set(PPG frequency, PPG amplitude, HF/LF ratio), Central Nervous System set(ERP amplitude P4, O1, O2, ERP latency P4, O1, O2, SSVEP S/N ratio P4, O1, O2). Then the correlation of three variables sets, canonical correlation analysis was conducted. Results: The results showed a significant correlation between visual fatigue and physiological measures. However, different variables of visual fatigue were highly correlated to respective HF/LF ratio and to ERP latency(O2). Conclusion: Response time was highly correlated to ERP latency(O2) while the subjective evaluation was to HF/LF ratio. Application: This study may provide the most significant variables for the quantitative evaluation of visual fatigue using HF/LF ratio and ERP latency based human performance and subjective fatigue.