A Study on Heart Rate Variability (HRV) of Women with Atrophic Vaginitis (위축성 질염을 호소하는 여성의 HRV 특성 연구)

  • Kim, Min-Young;Yoo, Eun-Sil;Hwang, Deok-Sang;Lee, Jin-Moo;Jang, Jun-Bock;Lee, Kyung-Sub;Lee, Chang-Hoon
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.28 no.3
    • /
    • pp.11-20
    • /
    • 2015
  • Objectives This study is performed to recognize the relationship between atrophic vaginitis and stress that have an affect on autonomic nervous system. Methods We studied 47 patients who visited Kangnam Kyunghee Korean Hospital Medical Examination Center from November, 2013 to June, 2014. They were devided into two groups, atrophic vaginitis group (AV, n=18) and non-atrophic vaginitis group (NAV, n=29). We compared the result of HRV between the two groups. Results The mean of The standard deviation of NN intervals (SDNN), the square root of the mean squared difference of successive NNs (RMSSD) in AV group was lower than NAV group, but there was no significant difference between the two groups. Total power (TP), low frequency (LF) and very low frequency (VLF) of AV group was significantly lower than NAV group. There was no significant difference in high frequency (HF). Conclusions Women with atrophic vaginitis is expected to have low adaptive capacity against stress.

The Effect of Sahyangsohapwon on Heart Rate Variability of Healthy Subjects (사향소합원(麝香蘇合元)이 정상인의 심박변이도에 미치는 영향)

  • Kim, Chang-Hyun;Hwang, Jae-Woong;Min, In-Kyu;Kim, Mi-Young;Byeon, Hyung-Sik;Na, Byong-Jo;Park, Sung-Wook;Park, Jung-Mi;Ko, Chang-Nam;Bae, Hyung-Sup;Jung, Woo-Sang;Moon, Sang-Kwan;Cho, Ki-Ho;Kim, Young-Suk
    • The Journal of Korean Medicine
    • /
    • v.30 no.1
    • /
    • pp.120-127
    • /
    • 2009
  • Objectives: Sahyangsohapwon (SS) is a herbal medication that has been widely used with circulatory and neural diseases. This study was conducted to assess the effect of SS on the autonomic nervous system by using heart rate variability measurement. Methods: The eligible subjects were enrolled from the healthy male group of ages 20 to 35 years. They were divided into two groups, the SS group (n=26) and the control (n=24). We monitored the ECG of subjects from the time period 14:00 to 18:00. In the SS group, subjects were administered with a dose of SS at the time 15:00, whereas the control group had none. For each hour HRV measurement was monitored every 15 minutes for 512 seconds from the time period 14:00 to 18:00. The mean value, which was calculated using the 4 values during each hour (i.e. 14:00, 14:15, 14:30, 14:45), was used as the representative value for each individual hour. For the measurement values, RR-interval and SDNN (standard deviation of the NN intervals) were used as time domain analysis, and HF (high frequency), LF (low frequency), and LF/HF ratio were used as frequency domain analysis. Results: The LF value showed an increase after one hour of SS administration and showed gradual diminution for each and every hour. The repeated measures of ANOVA for the comparison of the LF value between the SS group and the control group showed significant differences. While, RR interval, SDNN, HF, and LF/HF ratio values showed no significant differences between the two groups. Conclusions: We suggest that the SS might be useful for stabilizing autonomic nervous system by inhibiting sympathetic nerve activation in healthy people.

  • PDF

Relationships of Psychological Factors to Stress and Heart Rate Variability as Stress Responses Induced by Cognitive Stressors (스트레스에 대한 심리 반응 유형과 심박변이도의 관련성)

  • Jang, Eun Hye;Kim, Ah Young;Yu, Han Young
    • Science of Emotion and Sensibility
    • /
    • v.21 no.1
    • /
    • pp.71-82
    • /
    • 2018
  • Stress involves changes in behavior, autonomic function and the secretion of hormones. Autonomic nervous system (ANS) contributes to physiological adaptive process in short durations. In particular, heart rate variability (HRV) analysis is commonly used as a quantitative marker depicting the ANS activity related to mental stress. The aim of this study is to investigate correlations between psychological responses to stress and HRV indices induced by the cognitive stressor. Thirty-three participants rated their mental and physical symptoms occurred during the past two weeks on Stress Response Inventory (SRI), which is composed of seven stress factors that may influence the status of mental stress levels. Then, they underwent the psychophysiological procedures, which are collected electrocardiogram (ECG) signals during a cognitive stress task. HRV indices, the standard deviation of R-R interval (SDNN), root mean square of successive R-R interval difference (RMSSD) and low frequency (LF)/high frequency (HF) ratio were extracted from ECG signals. Physiological responses were calculated stress responses by subtracting mean of the baseline from the mean of recovery. Stress factors such as tension, aggression, depression, fatigue, and frustration were positively correlated to HRV indices. In particular, aggression had significant positive correlations to SDNN, RMSSD and LF/HF ratio. Increased aggressive responses to stress correlated with the increases of all HRV indices. This means the increased autonomic coactivation. Additionally, tension, depression, fatigue, and frustration were positively associated with RMSSD reflecting increases in parasympathetic activation. The autonomic coactivation may represent an integrated response to specific cognitive reactions such as the orienting response.

Autonomic Nervous Properties of Atropine and Glycopyrrolate on Heart Rate Variability during Anesthesia with Ketamine-Xylazine in Dogs (개에서 케타민-자일라진 마취동안 심박변이도에 대한 아트로핀과 글리코피롤레이트의 자율신경적 특성)

  • Park, Woo-Young;Bae, Chun-Sik;Lee, Soo-Han;Park, Woo-Dae
    • Journal of Veterinary Clinics
    • /
    • v.26 no.3
    • /
    • pp.212-219
    • /
    • 2009
  • Anticholinergics, which are commonly given as a pre-anesthetic medication to prevent adverse effects in canine anesthesia, can cause cardiac adverse effects. To determine the effects of atropine and glycopyrrolate on the balance of sympathetic nervous tone and parasympathetic nervous tone of the heart during ketamine anesthesia in beagle dogs, heart rate variability(HRV), duration of anesthesia and behavioral changes were evaluated. There were no significant temporal domain differences between atropine and glycopyrrolate. Concerning the frequency domain component, atropine and glycopyrrolate effects were significantly lower(P<0.05) than the control saline-treated group. However, the root mean square of the interval differences between consecutive R peaks(RMSSD) and the standard deviation of Poincare plot perpendicular to the line-of-identity(SD1) in atropine were significantly decreased(P<0.05) from the baseline value, and the low frequency/high frequency ratio(LF:HF ratio) in glycopyrrolate was significantly increased from baseline value(P<0.05). The change of SD1 agreed with that of the high frequency(HF) in the frequency domain component and also with those of respiratory rate and $SpO_2-R$. Our results prove that glycopyrrolate is more suitable as a pre-anesthetic anticholinergic in ketamine anesthesia of dogs with respect to safety and duration of action.

Autonomic Conditions in Allergic Rhinitis Depending on Various Pattern Identifications (알레르기 비염 환자의 변증별 자율신경계 특성 분석 연구)

  • Choi, Eun-Ji;Jang, Soobin;Lee, Kyu-Jin;Yun, Young-Hee;Choi, In-Hwa;Ko, Seong-Gyu
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.27 no.4
    • /
    • pp.110-120
    • /
    • 2014
  • Objectives : We performed a clinical study to investigate autonomic conditions in persistent allergic rhinitis depending on various pattern identifications and the availability of heart rate variability (HRV) as a pattern identification diagnostic tool. Methods : 32 patients with persistent allergic rhinitis were asked to interview with doctor of Korean Medicine and perform the four pattern questionnaires (Cold-Heat Pattern, Phlegm Pattern, Yin Deficiency pattern, bloodstasis pattern). Then, they were examined their autonomic conditions with heart rate variability test. Results : Patients were classified as three pattern groups (Lung-stomach heat, Lung qi deficiency cold, Lung-spleen qi deficiency) by doctor. In the Lung qi deficiency cold group, Total power of the HRV (TP) and the power of the low frequency component (LF) significantly higher than in the Lung-stomach heat or Lung-spleen qi deficiency group (P < 0.05). Also, Patients were classified as 8 pattern groups (Cold/Heat, Phlegm/Non-phlegm, Yin deficiency/Non-yin deficiency, Bloodstasis/Non-bloodstasis) by four pattern questionnaires. Only in the Yin deficiency group, the power of the low frequency component (LF) significantly lower than in the Non-yin deficiency group (P < 0.05). There were not any significant differences in the rest groups. Conclusions : The result may provide that HRV doesn't reflect well the differences in the various pattern groups, and the HRV's availability is low. Continuous studies are needed to develop the objective and standardized pattern identification diagnostic tool for allergic rhinitis.

One Case of Female Patient with Suspected Kleine-Levin Syndrome (여성 Kleine-Levin syndrome 의증 환자 1례)

  • Kim, Sang-Ho
    • The Journal of Korean Medicine
    • /
    • v.34 no.1
    • /
    • pp.179-191
    • /
    • 2013
  • Kleine-Levin syndrome is a rare disorder characterized by recurrent episodes of hypersomnia, hyperphagia, hypersexuality and delusion and hallucination with spontaneous recovery. A 17-year-old female suddenly showed hypersomnia, severe fatigue, and compulsive hyperphagia. She was diagnosed with suspected Kleine-Levin Syndrome. The precipitating factor was an upper respiratory tract infection that the patient had undergone 2 weeks prior. Past psychiatric history included somnambulism and ADHD; her symptoms of ADHD included attention deficit, impulsiveness, hyperactivity, and irritability. This was her third episode. Her hypersomnia was longer in duration but lower in frequency compared with usual KLS. Her low LF/HF ratio in heart rate variability measurement showed high parasympathetic nerve activity. A MMPI report showed some psychological problem. The patient was diagnosed of gastric fever by pattern identification. Her hypersomnia episode improved 6 weeks after onset. This is the first reported case of suspected Kleine-Levin Syndrome in the field of Oriental Medicine in Korea.

Comparison of Heart Rate Variability Indices between Obstructive Sleep Apnea Syndrome and Primary Insomnia (폐쇄성 수면무호흡 증후군과 일차성 불면증에서 심박동률 변이도 지수의 비교)

  • Nam, Ji-Won;Park, Doo-Heum;Yu, Jaehak;Ryu, Seung-Ho;Ha, Ji-Hyeon
    • Sleep Medicine and Psychophysiology
    • /
    • v.19 no.2
    • /
    • pp.68-76
    • /
    • 2012
  • Objectives: Sleep disorders cause changes of autonomic nervous system (ANS) which affect cardiovascular system. Primary insomnia (PI) makes acceleration of sympathetic nervous system (SNS) tone by sleep deficiency and arousal. Obstructive sleep apnea syndrome (OSAS) sets off SNS by frequent arousals and hypoxemias during sleep. We aimed to compare the changes of heart rate variability (HRV) indices induced by insomnia or sleep apnea to analyze for ANS how much to be affected by PI or OSAS. Methods: Total 315 subjects carried out nocturnal polysomnography (NPSG) were categorized into 4 groups - PI, mild, moderate and severe OSAS. Severity of OSAS was determined by apnea-hypopnea index (AHI). Then we selected 110 subjects considering age, sex and valance of each group's size [Group 1 : PI (mean age=$41.50{\pm}13.16$ yrs, AHI <5, n=20), Group 2 : mild OSAS (mean age=$43.67{\pm}12.11$ yrs, AHI 5-15, n=30), Group 3 : moderate OSAS (mean age $44.93{\pm}12.38$ yrs, AHI 16-30, n=30), Group 4 : severe OSAS (mean age=$45.87{\pm}12.44$ yrs, AHI >30, n=30)]. Comparison of HRV indices among the four groups was performed with ANCOVA (adjusted for age and body mass index) and Sidak post-hoc test. Results: We found statistically significant differences in HRV indices between severe OSAS group and the other groups (PI, mild OSAS and moderate OSAS). And there were no significant differences in HRV indices among PI, mild and moderate OSAS group. In HRV indices of PI and severe OSAS group showing the most prominent difference in the group comparisons, average RR interval were $991.1{\pm}27.1$ and $875.8{\pm}22.0$ ms (p=0.016), standard deviation of NN interval (SDNN) was $85.4{\pm}6.6$ and $112.8{\pm}5.4$ ms (p=0.022), SDNN index was $57.5{\pm}5.2$ and $87.6{\pm}4.2$ (p<0.001), total power was $11,893.5{\pm}1,359.9$ and $18,097.0{\pm}1,107.2ms^2$(p=0.008), very low frequency (VLF) was $7,534.8{\pm}1,120.1$ and $11,883.8{\pm}912.0ms^2$ (p=0.035), low frequency (LF) was $2,724.2{\pm}327.8$ and $4,351.6{\pm}266.9ms^2$(p=0.003). Conclusions: VLF and LF which were correlated with SNS tone showed more increased differences between severe OSAS group and PI group than other group comparisons. We could suggest that severe OSAS group was more influential to increased SNS activity than PI group.

Effects of 20-day litter weight on weaned piglets' fighting behavior after group mixing and on heart rate variability in an isolation test

  • Sun, YaNan;Lian, XinMing;Bo, YuKun;Guo, YuGuang;Yan, PeiShi
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.30 no.2
    • /
    • pp.267-274
    • /
    • 2017
  • Objective: The objective of this study was to investigate the effect of 20-day litter weight on behavior and heart rate variability (HRV) of piglets under stress. Methods: Forty four original litters were categorized as high litter weight (HW) litters (n = 22) and low litter weight (LW) litters (n = 22) by 20-day litter weight. From each original HW litter, three males and three females were randomly selected after weaning and the 12 piglets from two original litters with similar age of days were regrouped into one new high litter weight (NHW) litter (11 NHW litters in total). The original LW litters were treated with a same program, so that there were 11 new low litter weight (NLW) litters as well. The latencies to first fighting, fighting frequencies and duration within three hours were recorded after regrouping and the lesions on body surface within 48 hours were scored. Besides, HR (heart rate, bpm, beats per minute) and activity count (ACT), time domain indexes and frequency domain indexes of the piglets were measured in an isolation trial to analyze the discrepancy in coping with stress between the original HW and LW litters. Results: The results exhibited that piglets from the HW litters launched fighting sooner and got statistically higher skin lesion score than those from the LW litters (p = 0.03 and 0.02, respectively). Regarding the HRV detection, compared with the HW litters, the LW litters exhibited a lower mean HR (p<0.05). In the isolation test, a highly significant higher ACT value was observed between the HW litters, compared to the LW litters (p<0.01). Significant differences were observed in standard deviation of R-R intervals, standard deviation of all normal to normal intervals, and most frequency-domain indicators: very low-frequency, low-frequency, and high frequency between the HW and LW litters as well. The difference in LF:HF was not significant (p = 0.779). Conclusion: This study suggests that compared with litters of low 20-day litter weights, litters with higher 20-day litter weight take more positive strategies to cope with stress and have stronger HRV regulation capacity; HW litters demonstrate better anti-stress and adaptation capacity in the case of regrouping and isolation.

INTRODUCTION OF NUC ALGORITHM IN ON-BOARD RELATIVE RADIOMERIC CALIBRATION OF KOMPSAT-2

  • Song, J.H.;Choi, M.J.;Seo, D.C.;Lee, D.H.;Lim, H.S.
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.504-507
    • /
    • 2007
  • The KOMPSAT-2 satellite is a push-broom system with MSC (Multi Spectral Camera) which contains a panchromatic band and four multi-spectral bands covering the spectral range from 450nm to 900nm. The PAN band is composed of six CCD array with 2528 pixels. And the MS band has one CCD array with 3792 pixels. Raw imagery generated from a push-broom sensor contains vertical streaks caused by variability in detector response, variability in lens falloff, pixel area, output amplifiers and especially electrical gain and offset. Relative radiometric calibration is necessary to account for the detector-to-detector non-uniformity in this raw imagery. Non-uniformity correction (NUC) is that the process of performing on-board relative correction of gain and offset for each pixel to improve data compressibility and to reduce banding and streaking from aggregation or re-sampling in the imagery. A relative gain and offset are calculated for each detector using scenes from uniform target area such as a large desert, forest, sea. In the NUC of KOMPSAT-2, The NUC table for each pixel are divided as HF NUC (high frequency NUC) and LF NUC (low frequency NUC) to apply to few restricted facts in the operating system ofKOMPSAT-2. This work presents the algorithm and process of NUC table generation and shows the imagery to compare with and without calibration.

  • PDF

A Novel Three Phase Series-Parallel Resonant Converter Fed DC-Drive System

  • Daigavane, Manoj;Suryawanshi, Hiralal;Khan, Jawed
    • Journal of Power Electronics
    • /
    • v.7 no.3
    • /
    • pp.222-232
    • /
    • 2007
  • This paper presents the application of a single phase AC-to-DC converter using a three-phase series parallel (SPRC) resonant converter to variable speed dc-drive. The improved power quality converter gives the input power factor unity over a wide speed range, reduces the total harmonic distortion (THD) of ac input supply current, and makes very low ripples in the armature current and voltage waveform. This soft-switching converter not only possesses the advantages of achieving high switching frequencies with practically zero switching losses but also provides full ranges of voltage conversion and load variation. The proposed drive system is the most appropriate solution to preserve the present separately excited de motors in industry compared with the use of variable frequency ac drive technology. The simulation and experimental results are presented for variable load torque conditions. The variable frequency control scheme is implemented using a DSP- TMS320LF2402. This control reduces the switching losses and current ripples, eliminates the EMI and improves the efficiency of the drive system. Experimental results confirm the consistency of the proposed approach.